992 resultados para variable sampling interval
Resumo:
The objective of this work was to combine the advantages of the dried blood spot (DBS) sampling process with the highly sensitive and selective negative-ion chemical ionization tandem mass spectrometry (NICI-MS-MS) to analyze for recent antidepressants including fluoxetine, norfluoxetine, reboxetine, and paroxetine from micro whole blood samples (i.e., 10 microL). Before analysis, DBS samples were punched out, and antidepressants were simultaneously extracted and derivatized in a single step by use of pentafluoropropionic acid anhydride and 0.02% triethylamine in butyl chloride for 30 min at 60 degrees C under ultrasonication. Derivatives were then separated on a gas chromatograph coupled with a triple-quadrupole mass spectrometer operating in negative selected reaction monitoring mode for a total run time of 5 min. To establish the validity of the method, trueness, precision, and selectivity were determined on the basis of the guidelines of the "Société Française des Sciences et des Techniques Pharmaceutiques" (SFSTP). The assay was found to be linear in the concentration ranges 1 to 500 ng mL(-1) for fluoxetine and norfluoxetine and 20 to 500 ng mL(-1) for reboxetine and paroxetine. Despite the small sampling volume, the limit of detection was estimated at 20 pg mL(-1) for all the analytes. The stability of DBS was also evaluated at -20 degrees C, 4 degrees C, 25 degrees C, and 40 degrees C for up to 30 days. Furthermore, the method was successfully applied to a pharmacokinetic investigation performed on a healthy volunteer after oral administration of a single 40-mg dose of fluoxetine. Thus, this validated DBS method combines an extractive-derivative single step with a fast and sensitive GC-NICI-MS-MS technique. Using microliter blood samples, this procedure offers a patient-friendly tool in many biomedical fields such as checking treatment adherence, therapeutic drug monitoring, toxicological analyses, or pharmacokinetic studies.
Resumo:
BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.
Resumo:
Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers) used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI) estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI) procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.
Resumo:
La spectroscopie infrarouge (FTIR) est une technique de choix dans l'analyse des peintures en spray (traces ou bonbonnes de référence), grâce à son fort pouvoir discriminant, sa sensibilité, et ses nombreuses possibilités d'échantillonnage. La comparaison des spectres obtenus est aujourd'hui principalement faite visuellement, mais cette procédure présente des limitations telles que la subjectivité de la prise de décision car celle-ci dépend de l'expérience et de la formation suivie par l'expert. De ce fait, de faibles différences d'intensités relatives entre deux pics peuvent être perçues différemment par des experts, même au sein d'un même laboratoire. Lorsqu'il s'agit de justifier ces différences, certains les expliqueront par la méthode analytique utilisée, alors que d'autres estimeront plutôt qu'il s'agit d'une variabilité intrinsèque à la peinture et/ou à son vécu (par exemple homogénéité, sprayage, ou dégradation). Ce travail propose d'étudier statistiquement les différentes sources de variabilité observables dans les spectres infrarouges, de les identifier, de les comprendre et tenter de les minimiser. Le deuxième objectif principal est de proposer une procédure de comparaison des spectres qui soit davantage transparente et permette d'obtenir des réponses reproductibles indépendamment des experts interrogés. La première partie du travail traite de l'optimisation de la mesure infrarouge et des principaux paramètres analytiques. Les conditions nécessaires afin d'obtenir des spectres reproductibles et minimisant la variation au sein d'un même échantillon (intra-variabilité) sont présentées. Par la suite une procédure de correction des spectres est proposée au moyen de prétraitements et de sélections de variables, afin de minimiser les erreurs systématiques et aléatoires restantes, et de maximiser l'information chimique pertinente. La seconde partie présente une étude de marché effectuée sur 74 bonbonnes de peintures en spray représentatives du marché suisse. Les capacités de discrimination de la méthode FTIR au niveau de la marque et du modèle sont évaluées au moyen d'une procédure visuelle, et comparées à diverses procédures statistiques. Les limites inférieures de discrimination sont testées sur des peintures de marques et modèles identiques mais provenant de différents lots de production. Les résultats ont montré que la composition en pigments était particulièrement discriminante, à cause des étapes de corrections et d'ajustement de la couleur subies lors de la production. Les particularités associées aux peintures en spray présentes sous forme de traces (graffitis, gouttelettes) ont également été testées. Trois éléments sont mis en évidence et leur influence sur le spectre infrarouge résultant testée : 1) le temps minimum de secouage nécessaire afin d'obtenir une homogénéité suffisante de la peinture et, en conséquence, de la surface peinte, 2) la dégradation initiée par le rayonnement ultra- violet en extérieur, et 3) la contamination provenant du support lors du prélèvement. Finalement une étude de population a été réalisée sur 35 graffitis de la région lausannoise et les résultats comparés à l'étude de marché des bonbonnes en spray. La dernière partie de ce travail s'est concentrée sur l'étape de prise de décision lors de la comparaison de spectres deux-à-deux, en essayant premièrement de comprendre la pratique actuelle au sein des laboratoires au moyen d'un questionnaire, puis de proposer une méthode statistique de comparaison permettant d'améliorer l'objectivité et la transparence lors de la prise de décision. Une méthode de comparaison basée sur la corrélation entre les spectres est proposée, et ensuite combinée à une évaluation Bayesienne de l'élément de preuve au niveau de la source et au niveau de l'activité. Finalement des exemples pratiques sont présentés et la méthodologie est discutée afin de définir le rôle précis de l'expert et des statistiques dans la procédure globale d'analyse des peintures. -- Infrared spectroscopy (FTIR) is a technique of choice for analyzing spray paint speciments (i.e. traces) and reference samples (i.e. cans seized from suspects) due to its high discriminating power, sensitivity and sampling possibilities. The comparison of the spectra is currently carried out visually, but this procedure has limitations such as the subjectivity in the decision due to its dependency on the experience and training of the expert. This implies that small differences in the relative intensity of two peaks can be perceived differently by experts, even between analysts working in the same laboratory. When it comes to justifying these differences, some will explain them by the analytical technique, while others will estimate that the observed differences are mostly due to an intrinsic variability from the paint sample and/or its acquired characteristics (for example homogeneity, spraying, or degradation). This work proposes to statistically study the different sources of variability observed in infrared spectra, to identify them, understand them and try to minimize them. The second goal is to propose a procedure for spectra comparison that is more transparent, and allows obtaining reproducible answers being independent from the expert. The first part of the manuscript focuses on the optimization of infrared measurement and on the main analytical parameters. The necessary conditions to obtain reproducible spectra with a minimized variation within a sample (intra-variability) are presented. Following that a procedure of spectral correction is then proposed using pretreatments and variable selection methods, in order to minimize systematic and random errors, and increase simultaneously relevant chemical information. The second part presents a market study of 74 spray paints representative of the Swiss market. The discrimination capabilities of FTIR at the brand and model level are evaluated by means of visual and statistical procedures. The inferior limits of discrimination are tested on paints coming from the same brand and model, but from different production batches. The results showed that the pigment composition was particularly discriminatory, because of the corrections and adjustments made to the paint color during its manufacturing process. The features associated with spray paint traces (graffitis, droplets) were also tested. Three elements were identified and their influence on the resulting infrared spectra were tested: 1) the minimum shaking time necessary to obtain a sufficient homogeneity of the paint and subsequently of the painted surface, 2) the degradation initiated by ultraviolet radiation in an exterior environment, and 3) the contamination from the support when paint is recovered. Finally a population study was performed on 35 graffitis coming from the city of Lausanne and surroundings areas, and the results were compared to the previous market study of spray cans. The last part concentrated on the decision process during the pairwise comparison of spectra. First, an understanding of the actual practice among laboratories was initiated by submitting a questionnaire. Then, a proposition for a statistical method of comparison was advanced to improve the objectivity and transparency during the decision process. A method of comparison based on the correlation between spectra is proposed, followed by the integration into a Bayesian framework at both source and activity levels. Finally, some case examples are presented and the recommended methodology is discussed in order to define the role of the expert as well as the contribution of the tested statistical approach within a global analytical sequence for paint examinations.
Resumo:
La publicación en 1992 de Nubosidad variable supuso la reanudación de la actividad novelesca de Carmen Martín Gaite, después de catorce arios dedicados al ensayo y a la historia. En esta obra, el «credo» literario de la novelista no ha variado sustancialmente en relación a otras como Ritmo lento, Retahilas o El cuarto de atrás, pero se ha visto enriquecido con una técnica que acota y fija de forma maestra todo el mundo de significaciones que se proyecta, y que podemos conceptualizar como el flirteo de la autora con la introspección, el recuerdo, y los antojos frente al tiempo pasado de una memoria vulnerable y resbaladiza. La perspectiva narrativa se revela, en este sentido, como el apoyo básico del andamiaje material de la obra.
Resumo:
BACKGROUND: Low vitamin D status has been associated with an increased risk of developing type 2 diabetes and insulin resistance (IR), although this has been recently questioned. OBJECTIVE: We examined the association between serum vitamin D metabolites and incident IR. METHODS: This was a prospective, population-based study derived from the CoLaus (Cohorte Lausannoise) study including 3856 participants (aged 51.2 ± 10.4 y; 2217 women) free from diabetes or IR at baseline. IR was defined as a homeostasis model assessment (HOMA) index >2.6. Fasting plasma insulin and glucose were measured at baseline and at follow-up to calculate the HOMA index. The association of vitamin D metabolites with incident IR was analyzed by logistic regression, and the results were expressed for each independent variable as ORs and 95% CIs. RESULTS: During the 5.5-y follow-up, 649 (16.9%) incident cases of IR were identified. Participants who developed IR had lower baseline serum concentrations of 25-hydroxyvitamin D3 [25(OH)D3 (25-hydroxycholecalciferol); 45.9 ± 22.8 vs. 49.9 ± 22.6 nmol/L; P < 0.001], total 25(OH)D3 (25(OH)D3 + epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3]; 49.1 ± 24.3 vs. 53.3 ± 24.1 nmol/L; P < 0.001), and 3-epi-25(OH)D3 (4.2 ± 2.9 vs. 4.3 ± 2.5 nmol/L; P = 0.01) but a higher 3-epi- to total 25(OH)D3 ratio (0.09 ± 0.05 vs. 0.08 ± 0.04; P = 0.007). Multivariable analysis adjusting for month of sampling, age, and sex showed an inverse association between 25(OH)D3 and the likelihood of developing IR [ORs (95% CIs): 0.86 (0.68, 1.09), 0.60 (0.46, 0.78), and 0.57 (0.43, 0.75) for the second, third, and fourth quartiles compared with the first 25(OH)D3 quartile; P-trend < 0.001]. Similar associations were found between total 25(OH)D3 and incident IR. There was no significant association between 3-epi-25(OH)D3 and IR, yet a positive association was observed between the 3-epi- to total 25(OH)D3 ratio and incident IR. Further adjustment for body mass index, sedentary status, and smoking attenuated the association between 25(OH)D3, total 25(OH)D3, and the 3-epi- to total 25(OH)D3 ratio and the likelihood of developing IR. CONCLUSION: In the CoLaus study in healthy adults, the risk of incident IR is not associated with serum concentrations of 25(OH)D3 and total 25(OH)D3.
Resumo:
In 2008 the regional government of Catalonia (Spain) reduced the maximum speed limit on several stretches of congested urban motorway in the Barcelona metropolitan area to 80 km/h, while in 2009 it introduced a variable speed system on other stretches of its metropolitan motorways. We use the differences-in-differences method, which enables a policy impact to be measured under specific conditions, to assess the impact of these policies on emissions of NOx and PM10. Empirical estimation indicate that reducing the speed limit to 80 km h-1 causes a 1.7 to 3.2% increase in NOx and 5.3 to 5.9% in PM10. By contrast, the variable speed policy reduced NOx and PM10 pollution by 7.7 to 17.1% and 14.5 to 17.3%. As such, a variable speed policy appears to be a more effective environmental policy than reducing the speed limit to a maximum of 80 km/h.
Resumo:
BACKGROUND AND OBJECTIVE: Gastroschisis is a congenital anomaly with increasing incidence, easy prenatal diagnosis and extremely variable postnatal outcomes. Our objective was to systematically review the evidence regarding the association between prenatal ultrasound signs (intraabdominal bowel dilatation [IABD], extraabdominal bowel dilatation, gastric dilatation [GD], bowel wall thickness, polyhydramnios, and small for gestational age) and perinatal outcomes in gastroschisis (bowel atresia, intra uterine death, neonatal death, time to full enteral feeding, length of total parenteral nutrition and length of in hospital stay). METHODS: Medline, Embase, and Cochrane databases were searched electronically. Studies exploring the association between antenatal ultrasound signs and outcomes in gastroschisis were considered suitable for inclusion. Two reviewers independently extracted relevant data regarding study characteristics and pregnancy outcome. All meta-analyses were computed using individual data random-effect logistic regression, with single study as the cluster unit. RESULTS: Twenty-six studies, including 2023 fetuses, were included. We found significant positive associations between IABD and bowel atresia (odds ratio [OR]: 5.48, 95% confidence interval [CI] 3.1-9.8), polyhydramnios and bowel atresia (OR: 3.76, 95% CI 1.7-8.3), and GD and neonatal death (OR: 5.58, 95% CI 1.3-24.1). No other ultrasound sign was significantly related to any other outcome. CONCLUSIONS: IABD, polyhydramnios, and GD can be used to an extent to identify a subgroup of neonates with a prenatal diagnosis of gastroschisis at higher risk to develop postnatal complications. Data are still inconclusive on the predictive ability of several signs combined, and large prospective studies are needed to improve the quality of prenatal counseling and the neonatal care for this condition.
Resumo:
As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.
Resumo:
Previous studies have identified the rivalry among technological platforms as one of the main driving forces of broadband services penetration. This paper draws on data from the Spanish market between 2005 and 2011 to estimate the main determinants of broadband prices. Controlling for broadband tariffs features and network variables, we examine the impact of the different modes of competition on prices. We find that inter-platform competition has no significant effects over prices, while intra-platform competition is a key driver of the prices charged in the broadband market. Our analysis suggests that the impact of different types of competition on prices is critically affected by the levels of development of the broadband market achieved by the considered country