966 resultados para valve actuator
Resumo:
Short-bowel syndrome is responsible for significant metabolic alterations that compromise nutritional status. Glutamine is considered an essential nutrient for enterocytes, so beneficial effects from supplementation of the diet with glutamine are hypothesized. PURPOSE: In this study, the effect of a diet enriched with glutamine was evaluated in rats undergoing extensive small bowel resection, with analysis of postoperative weight loss and intestinal morphometrics of villi height, crypt depth, and thickness of the duodenal and remnant jejunal mucosa. METHODS: Three groups of male Wistar rats were established receiving the following diets: with glutamine, without glutamine, and the standard diet of laboratory ration. All animals underwent an extensive small bowel resection, including the ileocecal valve, leaving a remnant jejunum of only 25 cm from the pylorus that was anastomosed lateral-laterally to the ascendant colon. The animals were weighed at the beginning and end of the experiment (20th postoperative day). Then they were killed and the remnant intestine was removed. Fragments of duodenal and jejunal mucosa were collected from the remnant intestine and submitted to histopathologic exam. The morphometric study of the intestinal mucosa was accomplished using a digital system (KS 300) connected to an optic microscope. Morphometrics included villi height, crypt depth, and the total thickness of intestinal mucosa. RESULTS: The weight loss comparison among the 3 groups showed no significant loss difference. The morphometric studies showed significantly taller duodenal villi in the glutamine group in comparison to the without glutamine group, but not different from the standard diet group. The measurements obtained comparing the 3 groups for villi height, crypt depth, and thickness of the remnant jejunum mucosa were greater in the glutamine-enriched diet group than for the without-glutamine diet group, though not significantly different from with standard-diet group. CONCLUSIONS: In rats with experimentally produced short-bowel syndrome, glutamine-enrichment of an isonitrogenous test diet was associated with an improved adaptation response by the intestinal mucosa but not reduced weight loss. However, the adaptation response in the group receiving the glutamine-enriched diet was not improved over that for the group fed regular chow.
Resumo:
This research was carried out in three of the most important basins of the Colombian Amazon (Upper Solimões, Iça and Japurá Rivers). The creeks and lakes that were studied contain abundant diatom species, particularly those of the genus Eunotia. Ten species are described; five of them are registered for the first time in the Amazon basin, and six in all of Colombia. All taxa were photographed with scanning electron microscopy. Fine valve morphology of E. anamargariate, E. pseudoindica, E. triodon, and E. zydodon var. compacta is described for the first time.
Resumo:
Seismic investigations of typical south European masonry infilled frames were performed by testing two reduced scale specimens: one in the in-plane direction and another in the out-ofplane direction. Information about geometry and reinforcement scheme of those structures constructed in 1980s were obtained by [1]. The specimen to be tested in the in-plane direction was constructed as double leaf masonry while the specimen for testing in the out-of-plane direction is constructed with only its exterior leaf since the recent earthquakes have highlighted the vulnerability of the external leaf of the infills in out-of-plane direction [2]. The tests were performed by applying the pre-defined values of displacements in the in-plane and out-of-plane directions in the control points. For in-plane testing it was done by hydraulic actuator and for out-of-plane testing through the application of an airbag. Input and output air in the airbag was controlled by using a software to apply a specific displacement in the control point of the infill wall. Mid-point of the infill was assumed as a control point for outof- plane testing. Deformation and crack patterns of the infill confirm the formation of two-way arching mechanism of the masonry infill until collapse of the upper horizontal interface between infill and frame which is known as weakest interface due to difficulties in filling the mortar between bricks of last row and upper beam. This results in the crack opening through a welldefined path and the consequent collapse of the infill.
Resumo:
Previous study on the resistance of larvae of Sesarma curacaoense submitted to starvation has revealed a facultative lecithotrophy during zoeal stages, but megalopa and first juvenile stages are exclusively feeding stages. In the present study, the gross morphology and fine structure of the foregut of S. curacaoense were investigated during larval, megalopa and first juvenile stages. The foregut of the zoea I show specific setae and a filter press apparently functional. The foregut undergoes changes in the zoea II (last larval stage) with increment of setae number, mainly on the cardiopyloric valve and complexity of the filter press. After metamorphosis to megalopa stage the foregut become rather complex, with a gastric mill supporting a medial and two lateral teeth well-developed. The foregut of the first juvenile is more specialized compared to the previous stage, showing similar characteristics of the decapod adults. These results provide further evidence of facultative lecithotrophic development in the larvae of S. curacaoense.
Resumo:
The last decade has witnessed an increased research effort on multi-phase magnetoelectric (ME) composites. In this scope, this paper presents the application of novel materials for the development of anisotropic magnetoelectric (ME) sensors based on δ-FeO(OH)/P(VDF-TrFE) composites. The composite is able to precisely determine the amplitude and direction of the magnetic field. A new ME effect is reported in this study, as it emerges from the magnetic rotation of the δ-FeO(OH) nanosheets inside the piezoelectric P(VDF-TrFE) polymer matrix. δ-FeO(OH)/P(VDF-TrFE) composites with 1, 5, 10 and 20 δ-FeO(OH) filler weigh percentage in three δ-FeO(OH) alignment states (random, transversal and longitudinal) have been developed. Results shown that the modulus of the piezoelectric response (10-24 pC.N-1) is stable at least up to three months, the shape and magnetization maximum value (3 emu.g-1) is dependent on δ-FeO(OH) content and the obtained ME voltage coefficient, with a maximum of ≈0.4 mV.cm-1.Oe-1, is dependent on the incident magnetic field direction and intensity. In this way, the produced materials are suitable for innovative anisotropic sensor and actuator applications.
Resumo:
Electroactive polymers are one of the most interesting class of polymers used as smart materials in various applications, such as the development of sensors and actuators for biomedical applications in areas such as smart prosthesis, implantable biosensors and biomechanical signal monitoring, among others. For acquiring or applying the electrical signal from/to the piezoelectric material, suitable electrodes can be produced from Ti based coatings with tailored multifunctional properties, conductivity and antibacterial characteristics, through Ag inclusions. This work reports on Ag-TiNx electrodes, deposited by d. c. and pulsed magnetron sputtering at room temperature on poly(vinylidene fluoride), PVDF, the all-round best piezoelectric polymer.. Composition of the electrodes was assessed by microanalysis X-ray system (EDS - energy dispersive spectrometer). The XRD results revealed that the deposition conditions preserve the polymer structure and suggested the presence of crystalline fcc-TiN phase and fcc-Ag phase in samples with N2 flow above 3 sccm. According to the results obtained from SEM analysis, the coatings are homogeneous and Ag clusters were found for samples with nitrogen flow above 3 sccm. With increasing nitrogen flow, the sheet resistivity tend to be lower than the samples without nitrogen, leading also to a decrease of the piezoelectric response. It is concluded that the deposition conditions do significantly affect the piezoelectric polymer, which maintain its characteristics for sensor/actuator applications.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Dissertação de mestrado em Direito dos Contratos e da Empresa
Resumo:
"Series title: Springerbriefs in applied sciences and technology, ISSN 2191-530X"
Resumo:
OBJECTIVE: To verify if adaptive left ventricle (LV) characteristics are also present in individuals under 70 years of age with severe aortic stenosis (AS). METHODS: The study comprised 40 consecutive patients under 70 years of age with AS and no associated coronary artery disease, referred for valve surgery. Out of the 40 patients, 22 were men and 18 women, and the mean age was 49.8±14.3 years. Cardiac symptoms, presence of systemic hypertension (SH), functional class according to the New York Heart Association (NYHA), and valve lesion etiology were considered. LV cavity dimensions, ejection fraction (EF), fractional shortening (FS), mass (MS), and relative diastolic thickness (RDT) were examined by Doppler echocardiography. RESULTS: Fourteen (63.6%) men and 11 (61.6%) women were classified as NYHA class III/IV (p=0.70). There was no difference in the frequency of angina, syncope or dyspnea between genders. The incidence of SH was greater in women than in men (10 versus 2, p=0.0044). Women had a smaller LV end-diastolic diameter index (32.1±6.5 x 36.5±5.3mm/m², p=0.027), LV end-systolic diameter index (19.9±5.9 x 26.5±6.4mm/m², p=0.0022) and LV mass index (MS) (211.4±71.1 x 270.9±74.9g/m², p=0.017) when compared with men. EF (66.2±13.4 x 52.0±14.6%, p=0.0032), FS (37.6±10.7 x 27.9±9.6%, p=0.0046) and RDT (0.58±0.22 x 0.44±0.09, p=0.0095) were significantly greater in women than in men. CONCLUSION: It is the patient gender rather than age that influences left ventricular adaptive response to AS.
Resumo:
A forty eight year old woman, who had undergone mitral comissurotomy and subsequently developed early restenosis, presented with major comissural fusion and verrucous lesions on the cuspid edges of the mitral valve, with normal subvalvar apparatus. Patient did well for the first six months after surgery when she began to present dyspnea on light exertion. A clinical diagnosis of restenosis was made, which was confirmed by an echocardiogram and cardiac catheterization. She underwent surgery, and a stenotic mitral valve with verrucous lesions suggesting Libman-Sacks' endocarditis was found. Because the diagnosis of systemic lupus erythematosus (SLE) had not been confirmed at that time, a bovine pericardium bioprosthesis (FISICS-INCOR) was implanted. The patient did well in the late follow-up and is now in NYHA Class I .
Resumo:
OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.
Resumo:
PURPOSE: To report the result of patients treated with IV methylprednisolone divided into three groups and compare their follow-up during the last 12 years. METHODS: Seventy children with active rheumatic carditis (76 episodes) in heart failure Class III and IV (NYHA) were studied. The diagnosis was based on modified Jones' criteria. After ruling out infections and strongyloidiasis, treatment with IV methylprednisolone bolus was started three times a week until the laboratory tests became negative. Patients were divided into 3 groups, according to the time of hospital admittance: Groups 1, 2 and 3, comprising of 40, 18 and 12 children, respectively. RESULTS: Eighteen children in Group 1 (45%) were in their 1st attack: 2 series of pulsetherapy were used in 10 (25%), 3 in 9 (23%) and 4 in 21 (52%). In Group 2, 14 cases (77%) were in their 1st attack: 2 series were used in 7 (39%), 4 in 9 (50%) and 5 in 2 (11%). The echocardiogram showed a flail mitral valve in 12 (66%) of these patients (1 death occurred after mitral valvoplasty). In Group 3, 6 patients needed 5 or more series of pulsetherapy and a flail mitral valve was present in 5 (41%). One child underwent mitral valve replacement while still in the active phase, after 8 series of pulsetherapy, and another died. The number of patients who needed 5 or more series was significantly higher in Group 3. CONCLUSION: There were variations in the presentation and evolution of the cases during these 12 year. The established pulsetherapy protocol continues to be useful to treat severe cases.
Resumo:
OBJETIVE: To evaluate by Doppler echocardiography (DE) early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A) and 25 with CD4 cell count <500/mm³ (Group B), were analyzed. CD4 cells were counted and matched with structural data and systolic and diastolic function of the left ventricle (LV), as analyzed by DE. The results were compared with those obtained in 47 healthy individuals (Group C). RESULTS: 8% of patients in Group B had mild pericardial effusion; 31.5% showed decreased systolic function of the LV, and 12% had moderate mitral regurgitation. A wave velocity from the mitral inflow was different among the 3 groups, being higher in Group B, where the deceleration time of the E wave of the mitral inflow and the E/A ratio were significantly lower with a normal value of the isovolumic relaxation time (IVRT). CONCLUSION: HIV-positive patients with a CD4 cell count >500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³), had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.
Resumo:
Ebstein's anomaly with coarctation of the aorta is an extremely unusual condition. In this report, the clinical and surgical features of 3 male patients, aged 7 months, 4 years and 14 years, are discussed. All patients were in situs solitus. The first 2 patients had atrioventricular and ventriculoarterial discordance and progressed to heart failure in the neonatal period. The third had atrioventricular and ventriculoarterial concordance, as well as Wolf-Parkinson-White syndrome, with frequent episodes of paroxysmal tachycardia. The 3 patients underwent surgery for correction of the coarctation of the aorta. The patient with atrioventricular and ventriculoarterial concordance underwent tricuspid valvuloplasty using a DeVega-like technique. In addition, ablation of 2 anomalous pathways (Kent bundle), which were detected by the electrophysiologic study, was also subsequently performed. The 3 patients showed a good postoperative outcome for 2 years, although, in those with discordance, the surgical procedure did not influence the dysplasia of the tricuspid valve, because this valve showed light to moderate dysfunction.