987 resultados para vadose zone thickness
Resumo:
Gradient colloidal crystals with a thickness gradient were prepared by the vertical deposition technique with vertically graded concentration suspensions. The thickness of the gradient colloidal crystal gradually changes at different positions along the specific gradient direction of the crystal. The thickness gradient was determined by the concentration gradient, depending on the initial colloidal concentration and the settling time. The optical transmission intensity at the dip wavelength can be tuned by changing the thickness of the colloidal crystals. The gradient colloidal crystals lead to a gradient of optical intensity at the dip in transmission light. The gradient of optical intensity at the dip increases as the thickness gradient of the colloidal crystal increases.
Resumo:
Double-ceramic-layer (DCL) coatings with various thickness ratios composed of YSZ (6-8 wt.% Y2O3 + ZrO2) and lanthanum zirconate (LZ, La2Zr2O7) were produced by the atmospheric plasma spraying. Chemical stability of LZ in contact with YSZ in DCL coatings was investigated by calcining powder blends at different temperatures. No obvious reaction was observed when the calcination temperature was lower than 1250 degrees C, implying that LZ and YSZ had good chemical applicability for producing DCL coating. The thermal cycling test indicate that the cycling lives of the DCL coatings are strongly dependent on the thickness ratio of LZ and YSZ, and the coatings with YSZ thickness between 150 and 200 mu m have even longer lives than the single-layer YSZ coating. When the YSZ layer is thinner than 100 mu m, the DCL coatings failed in the LZ layer close to the interface of YSZ layer and LZ layer. For the coatings with the YSZ thickness above 150 mu m, the failure mainly occurs at the interface of the YSZ layer and the bond coat.
Resumo:
The p-toluene sulfonic acid (MA) in phenol matrix was separated and determined by capillary electrophoresis with ultraviolet detector. the effect of the concentration and pH of the buffer on separation was investigated. Cinnamic acid has been chosen as the internal standard from four compounds, the calibration curves of PTSA in 50 mg/L phenol matrix were obtained with and without the internal standard. The linear range was from 1.25 to 12.5 mg/L and the correlation coefficient was 0.9999 for both curves. The limit of detection of PISA was 0.75 mg/L at 3 times of SIN. Finally, the concentration of PTSA in four synthesized samples was determined with method of standard additions, and the effect of matrix was discussed. The values of MA in these samples were 1.01, 0.94, 1.56 and 0.00 mg/L respectively.
Resumo:
End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.
Resumo:
Aimed at saving the radiation dose required to crosslinking the polyamid-1010, BMI/PA1010 systems containing different amounts of difunctional crosslinking agent N,N'-bis-maleimide-4,4'-biphenyl methane (BMI) were prepared and the structure changes at the crystallographic and supermolecular levels before and after irradiation were studied by using WAXD, SAXS, and DSC techniques. It was found that by incorporation of BMI the microcrystal size L-100 is lowered due to the formation of hydrogen bond between the carbonyl oxygen of BMI and the amide hydrogen of PA1010 in the hydrogen bonded plane, and the overall crystallinity W-c is also decreased. The presence of BMI causes the crystal lamella thickness d(c) to decrease and greatly thickens the transition zone d(tr) between the crystalline and amorphous regions. As for the irradiated specimen, the maximum increments in the L-100 and W-c against dose curves decrease with BMI content, and the interception point D-i, at which the L-100 and W-c curves intercept their respective horizontal line of L-100/L-100(0) and W-c/W-c(0)=1, shift to lower dose with an increase in BMI concentration. In addition. the mechanism of the radiation chemical reactions in the three different phases under the action of BMI are discussed with special focus on the interface region. (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
A rapid and sensitive detection method for the determination of 5-fluorouracil(5-FU) in real samples such as human urine and bovine serum albumin (BSA) was described. A carbon fiber microdisk electrode was used to perform end-column amperometric detection in capillary zone electrophoresis. The detection limit was as low as 2.5x10(-7) M and the wider linear range for the concentration was between 5x10(-6) and 1x10(-4) M with a correlation coefficient of 0.995.
Resumo:
Structural studies of poly(aryl ether ether ketone ketone) (PEEKK) using small-angle X-ray scattering and one-dimensional electron density correlation function methods revealed that its aggregated state structure was significantly influenced by the annealing temperature. The long period L, the average thickness of the lamellae d, the electron density difference between the crystalline and amorphous regions eta(c) - eta(a), and the invariant Q increased with increasing annealing temperature, but it was opposite to the case of the specific inner surfaces O-s. A transition zone existed between the traditional "two phases" with a dimension about 0.5 nm for semicrystalline PEEKK. (C) 1998 John Wiley & Sons, Inc. J Appl Polym Sci 69: 1829-1835, 1998.
Resumo:
The effects of lamellar thickness on the epitaxial crystallization of polyethylene on the oriented isotatic polypropylene have been studied by means of transmission electron microscopy. The results obtained from the bright field electron microscopy and electron diffraction show that the epitaxial orientation of the PE crystals on the iPP substrate depends not only on the thickness of the oriented iPP lamellae, but also on the lamellar thickness of PE crystals. No epitaxial orientation relationship between PE crystal and iPP substrate can be found, when the PE crystals are thicker than the lamellar thickness of iPP along the matching direction. This suggests, that the epitaxial nucleation of PE in the PE/iPP epitaxial system is controlled not only by the chain-row matching, but also by a secondary nucleation process.
Resumo:
The plastic zone size and crack opening displacement of phenolphthalein polyether ketone (PEK-C) at various conditions were investigated. Both of them increase with increasing temperature (decreasing strain rate), i.e. yield stress steadily falls. Thus, the mechanism increasing the yield stress leads to increased constraint in the crack tip and a corresponding reduction in the crack opening displacement and the plastic deformation zone. The effect of the plastic deformation on the fracture toughness is also discussed.
Resumo:
Fracture toughness values of phenolphthalein poly(ether ketone) (PEK-C) at 190 degrees C were determined by two different methods, i. e. the conventional crack growth method and the crack stress whitening zone method, which show consistent results. This indicates that the crack stress whitening zone method can be used to determine the crack initiation of some polymers for which the blunting line concept is unsuitable.
Resumo:
A novel modified electrode dispersed with ultrafine platinum particles on the surface of a 30-mu m carbon fibre microelectrode was investigated as an amperometric detector in capillary zone electrophoresis (CEEC) for determining hydrazines. The unique cha
Resumo:
The effect of crystallization rate on the epitaxial interface layer thickness of high-density polyethylene (HDPE) in the epitaxial system with oriented isotactic polypropylene (iPP) has been investigated by electron microscopy. The results of bright-field
Resumo:
WAXD, SAXS, FTIR, DSC and density techniques have been used to investigate the crystal structure, crystal density rho(c), amorphous density rho(a), equilibrium heat of fusion DELTAH(m)degrees and equilibrium melting temperature T(m)degrees. By extrapolating the straight lines in the FTIR absorbance against density plot to zero intensity, rho(c) and rho(a) were estimated to be 1.098 and 1.003 g/cm3 respectively. The rho(c) obtained was too low in value. From X-ray diffraction patterns of uniaxially oriented fibres, the crystal structure of Nylon-1010 was determined. The Nylon-1010 crystallized in the triclinic system, with lattice dimensions: a = 4.9 angstrom, b = 5.4 angstrom, c = 27.8 angstrom, alpha = 49-degrees, beta = 77-degrees, gamma = 63.5-degrees. The unit cell contained one monomeric unit, the space group was P1BAR, and the correct value of rho(c) was 1.135 g/cm3. The degree of crystallinity of the polymer was determined as about 60% (at RT) using Ruland's method. SAXS has been used to investigate the crystalline lamellar thickness, long period, transition zone, the specific inner surface and the electron density difference between the crystalline and amorphous regions for Nylon-1010. The analysis of data was based upon a one-dimensional electron-density correlation function. DELTAH(m)degrees was estimated to be 244.0 J/g by extrapolation of DELTAH(m)degrees in the plot of heat of fusion against specific volume of semicrystalline specimens to the completely crystalline condition (V(sp)c = 1/rho(c)). Owing to the ease of recrystallization of melt-crystallized Nylon-1010 specimens, the well-known Hoffman's T(m)-T(c) method failed in determining T(m)degrees and a Kamide double extrapolation method was adopted. The T(m)degrees value so obtained was 487 K.