990 resultados para tracer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the results of airborne measurements of carbon monoxide (CO) and aerosol particle number concentration (CN) made during the Balan double dagger o Atmosf,rico Regional de Carbono na Amazonia (BARCA) program. The primary goal of BARCA is to address the question of basin-scale sources and sinks of CO2 and other atmospheric carbon species, a central issue of the Large-scale Biosphere-Atmosphere (LBA) program. The experiment consisted of two aircraft campaigns during November-December 2008 (BARCA-A) and May-June 2009 (BARCA-B), which covered the altitude range from the surface up to about 4500 m, and spanned most of the Amazon Basin. Based on meteorological analysis and measurements of the tracer, SF6, we found that airmasses over the Amazon Basin during the late dry season (BARCA-A, November 2008) originated predominantly from the Southern Hemisphere, while during the late wet season (BARCA-B, May 2009) low-level airmasses were dominated by northern-hemispheric inflow and mid-tropospheric airmasses were of mixed origin. In BARCA-A we found strong influence of biomass burning emissions on the composition of the atmosphere over much of the Amazon Basin, with CO enhancements up to 300 ppb and CN concentrations approaching 10 000 cm(-3); the highest values were in the southern part of the Basin at altitudes of 1-3 km. The Delta CN/Delta CO ratios were diagnostic for biomass burning emissions, and were lower in aged than in fresh smoke. Fresh emissions indicated CO/CO2 and CN/CO emission ratios in good agreement with previous work, but our results also highlight the need to consider the residual smoldering combustion that takes place after the active flaming phase of deforestation fires. During the late wet season, in contrast, there was little evidence for a significant presence of biomass smoke. Low CN concentrations (300-500 cm(-3)) prevailed basinwide, and CO mixing ratios were enhanced by only similar to 10 ppb above the mixing line between Northern and Southern Hemisphere air. There was no detectable trend in CO with distance from the coast, but there was a small enhancement of CO in the boundary layer suggesting diffuse biogenic sources from photochemical degradation of biogenic volatile organic compounds or direct biological emission. Simulations of CO distributions during BARCA-A using a range of models yielded general agreement in spatial distribution and confirm the important contribution from biomass burning emissions, but the models evidence some systematic quantitative differences compared to observed CO concentrations. These mismatches appear to be related to problems with the accuracy of the global background fields, the role of vertical transport and biomass smoke injection height, the choice of model resolution, and reliability and temporal resolution of the emissions data base.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents further results from our spectroscopic study of the globular cluster (GC) system of the group elliptical NGC 3923. From observations made with the GMOS instrument on the Gemini South Telescope, an additional 50 GC and ultra-compact dwarf (UCD) candidates have been spectroscopically confirmed as members of the NGC 3923 system. When the recessional velocities of these GCs are combined with the 29 GC velocities reported previously, a total sample of 79 GC/UCD velocities is produced. This sample extends to over 6 arcmin (>6 R-e similar to 30 kpc) from the centre of NGC 3923 and is used to study the dynamics of the GC system and the dark matter content of NGC 3923. It is found that the GC system of NGC 3923 displays no appreciable rotation, and that the projected velocity dispersion is constant with radius within the uncertainties. The velocity dispersion profiles of the integrated light and GC system of NGC 3923 are indistinguishable over the region in which they overlap. We find some evidence that the diffuse light and GCs of NGC 3923 have radially biased orbits within similar to 130 arcsec. The application of axisymmetric orbit-based models to the GC and integrated light velocity dispersion profiles demonstrates that a significant increase in the mass-to-light ratio (from M/L-V = 8 to 26) at large galactocentric radii is required to explain this observation. We therefore confirm the presence of a dark matter halo in NGC 3923. We find that dark matter comprises 17.5(-4.5)(+7.3) per cent of the mass within 1 R-e, 41.2(-10.6)(+18.2) per cent within 2 R-e and 75.6(-16.8)(+15.4) per cent within the radius of our last kinematic tracer at 6.9 R-e. The total dynamical mass within this radius is found to be 1.5(-0.25)(+0.4) x 10(12) M-circle dot. In common with other studies of large ellipticals, we find that our derived dynamical mass profile is consistently higher than that derived by X-ray observations, by a factor of around 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. Rest myocardial perfusion imaging (MPI) is effective in managing patients with acute chest pain in developed countries. We aimed to define the role and feasibility of rest MPI in low-to-middle income countries. Methods and Results. Low-to-intermediate risk patients (n = 356) presenting with chest pain to ten centers in eight developing countries were injected with a Tc-99m-based tracer, and standard imaging was performed. The primary outcome was a composite of death, non-fatal myocardial infarction (MI), recurrent angina, and coronary revascularization at 30 days. Sixty-nine patients had a positive MPI (19.4%), and 52 patients (14.6%) had a primary outcome event. An abnormal rest-MPI result was the only variable which independently predicted the primary outcome [adjusted odds ratio (OR) 8.19, 95% confidence interval 4.10-16.40, P = .0001]. The association of MPI result and the primary outcome was stronger (adjusted OR 17.35) when only the patients injected during pain were considered. Rest-MPI had a negative predictive value of 92.7% for the primary outcome, improving to 99.3% for the hard event composite of death or MI. Conclusions. Our study demonstrates that rest-MPI is a reliable test for ruling out MI when applied to patients in developing countries. (J Nucl Cardiol 2012;19:1146-53.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mesopontine rostromedial tegmental nucleus (RMTg) is a mostly ?-aminobutyric acid (GABA)ergic structure believed to be a node for signaling aversive events to dopamine (DA) neurons in the ventral tegmental area (VTA). The RMTg receives glutamatergic inputs from the lateral habenula (LHb) and sends substantial GABAergic projections to the VTA, which also receives direct projections from the LHb. To further specify the topography of LHb projections to the RMTg and VTA, small focal injections of the anterograde tracer Phaseolus vulgaris leucoagglutinin were aimed at different subdivisions of the LHb. The subnuclear origin of LHb inputs to the VTA and RMTg was then confirmed by injections of the retrograde tracer cholera toxin subunit b into the VTA or RMTg. Furthermore, we compared the topographic position of retrogradely labeled neurons in the RMTg resulting from VTA injections with that of anterogradely labeled axons emerging from the LHb. As revealed by anterograde and retrograde tracing, LHb projections were organized in a strikingly topographic manner, with inputs to the RMTg mostly arising from the lateral division of the LHb (LHbL), whereas inputs to the VTA mainly emerged from the medial division of the LHb (LHbM). In the RMTg, profusely branched LHb axons were found in close register with VTA projecting neurons and were frequently apposed to the latter. Overall, our findings demonstrate that LHb inputs to the RMTg and VTA arise from different divisions of the LHb and provide direct evidence for a disynaptic pathway that links the LHbL to the VTA via the RMTg. J. Comp. Neurol. 520:12781300, 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandstrom M, Park M, Costa EL, Hedenstierna G, Amato M. Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol 112: 225-236, 2012. First published September 29, 2011; doi: 10.1152/japplphysiol.01090.2010.-The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background Measurements of hormonal concentrations by immunoassays using fluorescent tracer substance (Eu3+) are susceptible to the action of chemical agents that may cause alterations in its original structure. Our goal was to verify the effect of two types of anticoagulants in the hormone assays performed by fluorometric (FIA) or immunofluorometric (IFMA) methods. Methods Blood samples were obtained from 30 outpatients and were drawn in EDTA, sodium citrate, and serum separation Vacutainer®Blood Collection Tubes. Samples were analyzed in automatized equipment AutoDelfia™ (Perkin Elmer Brazil, Wallac, Finland) for the following hormones: Luteinizing hormone (LH), Follicle stimulating homone (FSH), prolactin (PRL), growth hormone (GH), Sex hormone binding globulin (SHBG), thyroid stimulating hormone (TSH), insulin, C peptide, total T3, total T4, free T4, estradiol, progesterone, testosterone, and cortisol. Statistical analysis was carried out by Kruskal-Wallis method and Dunn's test. Results No significant differences were seen between samples for LH, FSH, PRL and free T4. Results from GH, TSH, insulin, C peptide, SHBG, total T3, total T4, estradiol, testosterone, cortisol, and progesterone were significant different between serum and EDTA-treated samples groups. Differences were also identified between serum and sodium citrate-treated samples in the analysis for TSH, insulin, total T3, estradiol, testosterone and progesterone. Conclusions We conclude that the hormonal analysis carried through by FIA or IFMA are susceptible to the effects of anticoagulants in the biological material collected that vary depending on the type of assay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN] As a consequence to hypobaric hypoxic exposure skeletal muscle atrophy is often reported. The underlying mechanism has been suggested to involve a decrease in protein synthesis in order to conserve O(2). With the aim to challenge this hypothesis, we applied a primed, constant infusion of 1-(13)C-leucine in nine healthy male subjects at sea level and subsequently at high-altitude (4559 m) after 7-9 days of acclimatization. Physical activity levels and food and energy intake were controlled prior to the two experimental conditions with the aim to standardize these confounding factors. Blood samples and expired breath samples were collected hourly during the 4 hour trial and vastus lateralis muscle biopsies obtained at 1 and 4 hours after tracer priming in the overnight fasted state. Myofibrillar protein synthesis rate was doubled; 0.041+/-0.018 at sea-level to 0.080+/-0.018%hr(-1) (p<0.05) when acclimatized to high altitude. The sarcoplasmic protein synthesis rate was in contrast unaffected by altitude exposure; 0.052+/-0.019 at sea-level to 0.059+/-0.010%hr(-1) (p>0.05). Trends to increments in whole body protein kinetics were seen: Degradation rate elevated from 2.51+/-0.21 at sea level to 2.73+/-0.13 micromolkg(-1)min(-1) (p = 0.05) at high altitude and synthesis rate similar; 2.24+/-0.20 at sea level and 2.43+/-0.13 micromolkg(-1)min(-1) (p>0.05) at altitude. We conclude that whole body amino acid flux is increased due to an elevated protein turnover rate. Resting skeletal muscle myocontractile protein synthesis rate was concomitantly elevated by high-altitude induced hypoxia, whereas the sarcoplasmic protein synthesis rate was unaffected by hypoxia. These changed responses may lead to divergent adaptation over the course of prolonged exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN] We hypothesized that reliance on lactate as a means of energy distribution is higher after a prolonged period of acclimatization (9 wk) than it is at sea level due to a higher lactate Ra and disposal from active skeletal muscle. To evaluate this hypothesis, six Danish lowlanders (25 +/- 2 yr) were studied at rest and during 20 min of bicycle exercise at 146 W at sea level (SL) and after 9 wk of acclimatization to 5,260 m (Alt). Whole body glucose Ra was similar at SL and Alt at rest and during exercise. Lactate Ra was also similar for the two conditions at rest; however, during exercise, lactate Ra was substantially lower at SL (65 micro mol. min(-1). kg body wt(-1)) than it was at Alt (150 micro mol. min(-1). kg body wt(-1)) at the same exercise intensity. During exercise, net lactate release was approximately 6-fold at Alt compared with SL, and related to this, tracer-calculated leg lactate uptake and release were both 3- or 4-fold higher at Alt compared with SL. The contribution of the two legs to glucose disposal was similar at SL and Alt; however, the contribution of the two legs to lactate Ra was significantly lower at rest and during exercise at SL (27 and 81%) than it was at Alt (45 and 123%). In conclusion, at rest and during exercise at the same absolute workload, CHO and blood glucose utilization were similar at SL and at Alt. Leg net lactate release was severalfold higher, and the contribution of leg lactate release to whole body lactate Ra was higher at Alt compared with SL. During exercise, the relative contribution of lactate oxidation to whole body CHO oxidation was substantially higher at Alt compared with SL as a result of increased uptake and subsequent oxidation of lactate by the active skeletal muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN] We used 5-yr concomitant data of tracer distribution from the BATS (Bermuda Time-series Study) and ESTOC (European Station for Time-Series in the Ocean, Canary Islands) sites to build a 1-D tracer model conservation including horizontal advection, and then compute net production and shallow remineralization rates for both sites. Our main goal was to verify if differences in these rates are consistent with the lower export rates of particulate organic carbon observed at ESTOC. Net production rates computed below the mixed layer to 110m from April to December for oxygen, dissolved inorganic carbon and nitrate at BATS (1.34±0.79 molO2 m?2, ?1.73±0.52 molCm?2 and ?125±36 mmolNm?2) were slightly higher for oxygen and carbon compared to ESTOC (1.03±0.62 molO2 m?2, ?1.42±0.30 molCm?2 and ?213±56 mmolNm?2), although the differences were not statistically significant. Shallow remineralization rates between 110 and 250m computed at ESTOC (?3.9±1.0 molO2 m?2, 1.53±0.43 molCm?2 and 38±155 mmolNm?2) were statistically higher for oxygen compared to BATS (?1.81±0.37 molO2 m?2, 1.52± 0.30 molCm?2 and 147±43 mmolNm?2). The lateral advective flux divergence of tracers, which was more significant at ESTOC, was responsible for the differences in estimated oxygen remineralization rates between both stations. According to these results, the differences in net production and shallow remineralization cannot fully explain the differences in the flux of sinking organic matter observed between both stations, suggesting an additional consumption of nonsinking organic matter at ESTOC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poröse Medien spielen in der Hydrosphäre eine wesentliche Rolle bei der Strömung und beim Transport von Stoffen. In diesem Raum finden komplexe Prozesse statt: Advektion, Kon-vektion, Diffusion, hydromechanische Dispersion, Sorption, Komplexierung, Ionenaustausch und Abbau. Die strömungsmechanischen- und die Transportverhältnisse in porösen Medien werden direkt durch die Geometrie des Porenraumes selbst und durch die Eigenschaften der transportierten (oder strömenden) Medien bestimmt. In der Praxis wird eine Vielzahl von empirischen Modellen verwendet, die die Eigenschaften des porösen Mediums in repräsentativen Elementarvolumen wiedergeben. Die Ermittlung der in empirischen Modellen verwendeten Materialparameter erfolgt über Labor- oder Feldbestimmungsmethoden. Im Rahmen dieser Arbeit wurde das Computer-modell PoreFlow entwickelt, welches die hydraulischen Eigenschaften eines korngestützten porösen Mediums aus der mikroskopischen Modellierung des Fluidflusses und Transportes ableitet. Das poröse Modellmedium wird durch ein dreidimensionales Kugelpackungsmodell, zusam-mengesetzt aus einer beliebigen Kornverteilung, dargestellt. Im Modellporenraum wird die Strömung eines Fluids basierend auf einer stationären Lösung der Navier-Stokes-Gleichung simuliert. Die Ergebnisse der Modellsimulationen an verschiedenen Modellmedien werden mit den Ergebnissen von Säulenversuchen verglichen. Es zeigt sich eine deutliche Abhängigkeit der Strömungs- und Transportparameter von der Porenraumgeometrie sowohl in den Modell-simulationen als auch in den Säulenexperimenten.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of the thesis was to compare Galactic and extragalactic star-forming environments, to understand whether we can derive scaling relations for the extragalactic star formation from our understanding of the Galactic star formation; and to analyze the effect of the angular resolution of the observations and the molecular tracer used in extragalactic studies. It is therefore necessary to perform observations at the same linear resolution in both cases. With this in mind we have started a program aimed at comparing properties of mini-starburst regions in our Galaxy and starbursts in nearby galaxies at similar linear resolutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Der Filmbildungsprozess wässriger Polymerdispersionen wurde mit forcierter Rayleighstreuung untersucht.Diffusionskoeffizienten D von Farbstoffsonden sind damit zwischen 10^-21 und 10^-9 m^2s^-1 zugänglich. Das Diffusionsverhalten der hydrophoben FarbstoffsondeAberchrome in feuchten und trockenen Filmen aus Poly(n-butylmethacrylat-co-acrylsäure)-Dispersionen sowie bei der Wiederbefeuchtung trockener Filme wurde untersucht.Die Dynamik von Aberchrome weicht in feuchten Filmen von Fickscher Diffusion ab. Dies äußert sich in Abweichungen vomcharakteristischen q^2-Verhalten der Relaxationsrate tau^-1 (tau^-1 = Dq^2; q:Streuvektor) und im Auftreten gestrecktexponentieller Intensitätsrelaxationskurven. Diese Anomalie wurde mit einem apparenten, längenskalenabhängigen Diffusionskoeffizienten Dapp(Lambda) (Lambda= 2Pi/q) beschrieben, der für Lambda -> 0 Werte annimmt, die einem homogen hydroplastifizierten Polymermaterial entsprechen, während Dapp(Lambda) für Lambda -> Unendlich stark anwächst. Diese Anomalien verschwinden bei Wassergehalten entsprechend der Polymerwasserlöslichkeit. Weiteres Trocknen führt zum Absinken des Fickschen-Diffusionskoeffizienten auf einen Grenzwert für trockene Filme. Die Ergebnisse konnten mit einem Zwei-Zustands-Modell beschrieben werden: Die Sonde diffundiert Ficksch in einer hydrophilen Grenzflächenphase und einer langsamen Polymerphase. Austausch zwischendiesen Phasen ist ohne Einschränkung möglich. Das Modell erlaubt die Quantifizierung des Einflusses des Trocknungsprozesses auf Polymer- und Grenzflächenphaseneigenschaften.Dies wurde durch systematische Veränderungen der Grenzflächeneigenschaften demonstriert. Dies geschah durch Acrylsäuregehaltvariationen in den Poly(n-butylmethacrylat-co-acrylsäure)-Dispersionen und Emulgatorbedeckungsgradvariationen. In beiden Fällen reflektieren sich Dispersionsveränderungen in einer Veränderung der Modellparameter in der Grenzflächenphase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZusammenfassungIn der vorliegenden Arbeit ist eine Enzymimmunoelektrode zur Bestimmung von Atrazin in Wasser entwickelt worden. Die Motivation war, einen Immunoassay zu entwickeln, der ohne die speziellen Geräte, wie einen EIA-Reader, durchgeführt werden konnte. Dafür müssen drei Änderungen vorgenommen werden. Es muß das Detektorsystem EIA-Reader zur Meßwerterfassung ersetzt werden, und damit muß die nur im EIA-Reader verwendbare Mikrotiterplatte ausgetauscht werden. Als drittes muß der Immunoassay dem neuen Detektorsystem angepaßt werden. Eine pH-Elektrode wurde anstelle des EIA-Readers benutzt. Als Enzym, das eine pH-Änderung induziert, wurde Lactamase ausgewählt. Als Festphase wurden anstelle der Mikrotiterplatte Polystyrolmikropartikel (PSMP) verwendet. Die Entwicklung der Enzymimmunoelektrode erfolgte in drei Schritten: Entwicklung des Immunoassays für Atrazin unter Verwendung von Lactamase, Übertragung auf die Festphase PSMP und Einsatz der pH-Elektrode als Detektorsystem. Zuerst wurden Tracer mit dem Enzym Lactamase hergestellt. Als Haptene wurden 2-Chlor-4-(isopropylamino)-6-[(1-carboxypent-5-yl)amino]-s-Triazin (iPr/Cl/C6), Di-Chloratrazin und Di-Chlorsimazin verwendet. Es wurden unterschiedliche Testmittelpunkte im Immunoassay erreicht, (iPr/Cl/C6 I50 = 1.22µg/L; Dichloratrazin I50 = 0.27µg/L; Di-Chlorsimazin I50 = 0.12µg/L). Aufgrund der nur mäßigen Stabilität der Tracer unter Verwendung der Di-Chlorderivate wurde auf deren Verwendung bei der Entwicklung der Immunoelektrode verzichtet.Im zweiten Schritt erfolgte die Übertragung auf PSMP. Die Verwendung der PSMP hatte außer einer Verbesserung des Testmittelpunktes auf 1.00µg/L noch den Vorteil, daß die benötigten Mengen an Antikörper verringert werden konnten.Danach wurde die pH-Elektrode als Signalwandler zur Bestimmung des Atrazins eingesetzt. Unter Verwendung der pH-Elektrode konnte der bisher niedrigste Testmittelpunkt (I50 = 0.005µg/L) zur Bestimmung von Atrazin erreicht werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The research is aimed at contributing to the identification of reliable fully predictive Computational Fluid Dynamics (CFD) methods for the numerical simulation of equipment typically adopted in the chemical and process industries. The apparatuses selected for the investigation, specifically membrane modules, stirred vessels and fluidized beds, were characterized by a different and often complex fluid dynamic behaviour and in some cases the momentum transfer phenomena were coupled with mass transfer or multiphase interactions. Firs of all, a novel modelling approach based on CFD for the prediction of the gas separation process in membrane modules for hydrogen purification is developed. The reliability of the gas velocity field calculated numerically is assessed by comparison of the predictions with experimental velocity data collected by Particle Image Velocimetry, while the applicability of the model to properly predict the separation process under a wide range of operating conditions is assessed through a strict comparison with permeation experimental data. Then, the effect of numerical issues on the RANS-based predictions of single phase stirred tanks is analysed. The homogenisation process of a scalar tracer is also investigated and simulation results are compared to original passive tracer homogenisation curves determined with Planar Laser Induced Fluorescence. The capability of a CFD approach based on the solution of RANS equations is also investigated for describing the fluid dynamic characteristics of the dispersion of organics in water. Finally, an Eulerian-Eulerian fluid-dynamic model is used to simulate mono-disperse suspensions of Geldart A Group particles fluidized by a Newtonian incompressible fluid as well as binary segregating fluidized beds of particles differing in size and density. The results obtained under a number of different operating conditions are compared with literature experimental data and the effect of numerical uncertainties on axial segregation is also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diabetes mellitus umfasst eine heterogene Gruppe von Stoffwechselfunktionsstörungen, die durch hohe Blut-Glukose-Werte gekennzeichnet sind. Zwei Haupttypen von Diabetes mellitus wurden definiert: Typ 1- und Typ 2-Diabetes. Repaglinid ist ein neuer, schnell wirksamer, bei Typ 2-Diabetikern eingesetzter prandialer Glukose-Regulator mit einer kurzen Plasmahalbwertszeit (<1 Stunde) und der erste Vertreter der Carbamoylmethylbenzoesäure Familie, der in klinischen Studien getestet wurde. Die 18F- und 11C-markierten Repaglinid-Derivate (S)-2-(2-[18F]Fluorethoxy)-4-((3-methyl-1-(2-piperidin-1-yl-phenyl)-butylcarbamoyl)-methyl)-benzoesäure ([18F]Fluorethoxy-desethoxy-Repaglinid) und (S)-2-([11C]Methoxy)-4-([3-methyl-1-(2-piperidin-1-yl-phenyl)-butyl-carba-moyl]-benzoesäure ([11C]Methoxy-desethoxy-Repaglinid) wurden als potentielle Tracer für die nicht-invasive Quantifizierung des Sulfonylharnstoffrezeptor-Typ1-Status (SUR-1) der Insulin-sezernierenden -Zellen mittels Positronen-Emissions-Tomographie (PET) synthetisiert. [18F]Fluorethoxy-desethoxy-Repaglinide konnte in einer radiochemischen Ausbeute (RCA) von 20% nach 135 Minuten mit einer radiochemischen Reinheit >98% unter Verwendung des sekundären Markierungsvorläufers 2-[18F]Fluorethyltosylat erhalten werden. Die spezifische Aktivität lag im Bereich von 50-60 GBq/µmol. Für die radioaktive Synthese des [11C]Methoxy-desethoxy-Repaglinids wurde der sekundäre Markierungsvorläufer [11C]Methyliodid verwendet. Der 11C-Radiotracer wurde in einer RCA von 35% (bezogen auf [11C]CO2) mit einer spezifischen Aktivität von 40-70 GBq/µmol erhalten. Um die Eigenschaften des fluorierten sowie des methoxylierten Repaglinids zu charakterisieren, wurde die Affinität beider Verbindungen zum humanen SUR-1 evaluiert. [19F]Fluorethoxy-desethoxy-Repaglinid und Methoxy-desethoxy-Repaglinid induzierten Verdrängungskurven mit Hill-Koeffizienten nahe 1 und ergaben Dissotiationskonstanten (KD) von 142 nM beziehungsweise 83 nM - vergleichsweise geringe Verluste relativ zu Original-Repaglinid. Die biologische Aktivität wurde mittels Insulin-Sekretionstests an isolierten Ratten-Inselzellen gezeigt und war ebenfalls mit der des Repaglinids vergleichbar. Schließlich wurde die Biodistribution des [18F]Fluorethoxy-desethoxy-Repaglinids in gesunden Sprague-Dawley-Ratten durch Messung der Konzentration der Verbindung in verschiedenen Organen nach intravenöser Injektion untersucht. Das pankreatische Gewebe zeigte im Zeitintervall zwischen 10 und 30 Minuten nach Injektion eine stabile Akkumulation von etwa 0.12% der injizierten Dosis. 50% dieser Tracer-Akkulmulation konnten durch zusätzliche Injektion von nicht-radioaktiv-markiertem Repaglinid verdrängt werden, was auf eine mögliche Eignung des [18F]Fluorethoxy-desethoxy-Repaglinids für in vivo-Untersuchungen mittels PET schließen lässt. Eine erste humane PET-Studie zeigte zwar ebenfalls eine stabile, allerdings nur geringere Akkumulation von [18F]Fluorethoxy-desethoxy-Repaglinid im Pankreas und eine überproportional hohe Aktivitätsanreicherung in der Leber. Die Radioaktivitäts-akkumulation im Blut fiel nach wenigen Minuten unter die des Pankreas.