885 resultados para systematic product design
Resumo:
PURPOSE The objectives of this systematic review are (1) to quantitatively estimate the esthetic outcomes of implants placed in postextraction sites, and (2) to evaluate the influence of simultaneous bone augmentation procedures on these outcomes. MATERIALS AND METHODS Electronic and manual searches of the dental literature were performed to collect information on esthetic outcomes based on objective criteria with implants placed after extraction of maxillary anterior and premolar teeth. All levels of evidence were accepted (case series studies required a minimum of 5 cases). RESULTS From 1,686 titles, 114 full-text articles were evaluated and 50 records included for data extraction. The included studies reported on single-tooth implants adjacent to natural teeth, with no studies on multiple missing teeth identified (6 randomized controlled trials, 6 cohort studies, 5 cross-sectional studies, and 33 case series studies). Considerable heterogeneity in study design was found. A meta-analysis of controlled studies was not possible. The available evidence suggests that esthetic outcomes, determined by esthetic indices (predominantly the pink esthetic score) and positional changes of the peri-implant mucosa, may be achieved for single-tooth implants placed after tooth extraction. Immediate (type 1) implant placement, however, is associated with a greater variability in outcomes and a higher frequency of recession of > 1 mm of the midfacial mucosa (eight studies; range 9% to 41% and median 26% of sites, 1 to 3 years after placement) compared to early (type 2 and type 3) implant placement (2 studies; no sites with recession > 1 mm). In two retrospective studies of immediate (type 1) implant placement with bone graft, the facial bone wall was not detectable on cone beam CT in 36% and 57% of sites. These sites had more recession of the midfacial mucosa compared to sites with detectable facial bone. Two studies of early implant placement (types 2 and 3) combined with simultaneous bone augmentation with GBR (contour augmentation) demonstrated a high frequency (above 90%) of facial bone wall visible on CBCT. Recent studies of immediate (type 1) placement imposed specific selection criteria, including thick tissue biotype and an intact facial socket wall, to reduce esthetic risk. There were no specific selection criteria for early (type 2 and type 3) implant placement. CONCLUSIONS Acceptable esthetic outcomes may be achieved with implants placed after extraction of teeth in the maxillary anterior and premolar areas of the dentition. Recession of the midfacial mucosa is a risk with immediate (type 1) placement. Further research is needed to investigate the most suitable biomaterials to reconstruct the facial bone and the relationship between long-term mucosal stability and presence/absence of the facial bone, the thickness of the facial bone, and the position of the facial bone crest.
Resumo:
BACKGROUND Anthelmintic drugs have been widely used in sheep as a cost-effective means for gastro-intestinal nematode (GIN) control. However, growing anthelmintic resistance (AHR) has created a compelling need to identify evidence-based management recommendations that reduce the risk of further development and impact of AHR. OBJECTIVE To identify, critically assess, and synthesize available data from primary research on factors associated with AHR in sheep. METHODS Publications reporting original observational or experimental research on selected factors associated with AHR in sheep GINs and published after 1974, were identified through two processes. Three electronic databases (PubMed, Agricola, CAB) and Web of Science (a collection of databases) were searched for potentially relevant publications. Additional publications were identified through consultation with experts, manual search of references of included publications and conference proceedings, and information solicited from small ruminant practitioner list-serves. Two independent investigators screened abstracts for relevance. Relevant publications were assessed for risk of systematic bias. Where sufficient data were available, random-effects Meta-Analyses (MAs) were performed to estimate the pooled Odds Ratio (OR) and 95% Confidence Intervals (CIs) of AHR for factors reported in ≥2 publications. RESULTS Of the 1712 abstracts screened for eligibility, 131 were deemed relevant for full publication review. Thirty publications describing 25 individual studies (15 observational studies, 7 challenge trials, and 3 controlled trials) were included in the qualitative synthesis and assessed for systematic bias. Unclear (i.e. not reported, or unable to assess) or high risk of selection bias and confounding bias was found in 93% (14/15) and 60% (9/15) of the observational studies, respectively, while unclear risk of selection bias was identified in all of the trials. Ten independent studies were included in the quantitative synthesis, and MAs were performed for five factors. Only high frequency of treatment was a significant risk factor (OR=4.39; 95% CI=1.59, 12.14), while the remaining 4 variables were marginally significant: mixed-species grazing (OR=1.63; 95% CI=0.66, 4.07); flock size (OR=1.02; 95% CI=0.97, 1.07); use of long-acting drug formulations (OR=2.85; 95% CI=0.79, 10.24); and drench-and-shift pasture management (OR=4.08; 95% CI=0.75, 22.16). CONCLUSIONS While there is abundant literature on the topic of AHR in sheep GINs, few studies have explicitly investigated the association between putative risk or protective factors and AHR. Consequently, several of the current recommendations on parasite management are not evidence-based. Moreover, many of the studies included in this review had a high or unclear risk of systematic bias, highlighting the need to improve study design and/or reporting of future research carried out in this field.
Resumo:
OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.
Resumo:
BACKGROUND Metamizole is used to treat pain in many parts of the world. Information on the safety profile of metamizole is scarce; no conclusive summary of the literature exists. OBJECTIVE To determine whether metamizole is clinically safe compared to placebo and other analgesics. METHODS We searched CENTRAL, MEDLINE, EMBASE, CINAHL, and several clinical trial registries. We screened the reference lists of included trials and previous systematic reviews. We included randomized controlled trials that compared the effects of metamizole, administered to adults in any form and for any indication, to other analgesics or to placebo. Two authors extracted data regarding trial design and size, indications for pain medication, patient characteristics, treatment regimens, and methodological characteristics. Adverse events (AEs), serious adverse events (SAEs), and dropouts were assessed. We conducted separate meta-analyses for each metamizole comparator, using standard inverse-variance random effects meta-analysis to pool the estimates across trials, reported as risk ratios (RRs). We calculated the DerSimonian and Laird variance estimate T2 to measure heterogeneity between trials. The pre-specified primary end point was any AE during the trial period. RESULTS Of the 696 potentially eligible trials, 79 trials including almost 4000 patients with short-term metamizole use of less than two weeks met our inclusion criteria. Fewer AEs were reported for metamizole compared to opioids, RR = 0.79 (confidence interval 0.79 to 0.96). We found no differences between metamizole and placebo, paracetamol and NSAIDs. Only a few SAEs were reported, with no difference between metamizole and other analgesics. No agranulocytosis or deaths were reported. Our results were limited by the mediocre overall quality of the reports. CONCLUSION For short-term use in the hospital setting, metamizole seems to be a safe choice when compared to other widely used analgesics. High-quality, adequately sized trials assessing the intermediate- and long-term safety of metamizole are needed.
Resumo:
INTRODUCTION Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. MATERIALS AND METHODS A task force consisting of representatives of the German Arthroplasty Registry, industry, and computer specialists agreed on a solution that allows barcode scanning of implant components and that also uses a detailed standardized classification describing arthroplasty components. The manufacturers classified all their components that are sold in Germany according to this classification. The implant database was analyzed regarding the completeness of components by algorithms and real-time data. RESULTS The implant library could be set up successfully. At this point, the implant database includes more than 38,000 items, of which all were classified by the manufacturers according to the predefined scheme. Using patient data from the German Arthroplasty Registry, several errors in the database were detected, all of which were corrected by the respective implant manufacturers. CONCLUSIONS The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.
Resumo:
OBJECTIVE The aim of the present systematic review and meta-analysis was to assess the clinical efficacy of regenerative periodontal surgery of intrabony defects using a combination of enamel matrix derivative (EMD) and bone graft compared with that of EMD alone. MATERIALS AND METHODS The Cochrane Oral Health Group specialist trials, MEDLINE, and EMBASE databases were searched for entries up to February 2014. The primary outcome was gain of clinical attachment (CAL). Weighted means and forest plots were calculated for CAL gain, probing depth (PD), and gingival recession (REC). RESULTS Twelve studies reporting on 434 patients and 548 intrabony defects were selected for the analysis. Mean CAL gain amounted to 3.76 ± 1.07 mm (median 3.63 95 % CI 3.51-3.75) following treatment with a combination of EMD and bone graft and to 3.32 ± 1.04 mm (median 3.40; 95 % CI 3.28-3.52) following treatment with EMD alone. Mean PD reduction measured 4.22 ± 1.20 mm (median 4.10; 95 % CI 3.96-4.24) at sites treated with EMD and bone graft and yielded 4.12 ± 1.07 mm (median 4.00; 95 % CI 3.88-4.12) at sites treated with EMD alone. Mean REC increase amounted to 0.76 ± 0.42 mm (median 0.63; 95 % CI 0.58-0.68) at sites treated with EMD and bone graft and to 0.91 ± 0.26 mm (median 0.90; 95 % CI 0.87-0.93) at sites treated with EMD alone. CONCLUSIONS Within their limits, the present results indicate that the combination of EMD and bone grafts may result in additional clinical improvements in terms of CAL gain and PD reduction compared with those obtained with EMD alone. The potential influence of the chosen graft material or of the surgical procedure (i.e., flap design) on the clinical outcomes is unclear. CLINICAL RELEVANCE The present findings support the use of EMD and bone grafts for the treatment of intrabony periodontal defects.
Resumo:
The aim of this study was to evaluate the stability of Le Fort I maxillary inferior repositioning surgery in patients with a vertical maxillary deficiency at least 6 months after surgery. The electronic databases were searched to identify all articles reporting the long-term effects of one-piece maxillary inferior repositioning with rigid fixation. Methodological quality was evaluated according to 15 criteria related to study design, measurements, and statistical analysis. Two articles were identified, with a total of 22 patients. The maxilla was repositioned inferiorly from a mean 3.2 to 4.5mm in the anterior part and from a mean 0.1 to 1.8mm in the posterior part. At 6 months post-treatment, absolute relapse of a mean 1.6mm was measured for the anterior part of the maxilla and 0.3mm for the posterior part of the maxilla. The stability of maxillary inferior repositioning surgery could not be confirmed due to the small sample size, unclear diagnosis, and potential confounding factors.
Resumo:
OBJECTIVE To evaluate the risk of failure of fixed orthodontic retention protocols. DATA Screening for inclusion eligibility, quality assessment of studies and data extraction was performed independently by two authors. SOURCES The electronic databases MEDLINE, EMBASE and CENTRAL were searched with no restrictions on publication date or language using detailed strategies. The main outcome assessed was bond failure. STUDY SELECTION Twenty-seven studies satisfied the inclusion criteria. Randomised controlled trials and prospective studies were evaluated according to the Cochrane risk of bias tool. Retrospective studies were graded employing the predetermined criteria of Bondemark. RESULTS Nine randomised controlled trials, four of which were of low quality, were identified. Six studies had a prospective design and all were of low quality. Twelve studies were retrospective. The quality of trial reporting was poor in general. Four studies assessing glass-fibre retainers, three RCTs and one prospective, reported bond failures from 11 to 71%, whereas twenty studies evaluating multistranded retainers – nine RCTs, two prospective and nine retrospective – reported failures ranging from 12 to 50%. One comparison was performed, multistranded wires vs. polyehtylene woven ribbon (RR: 1.74; 95% CI: 0.45, 6.73; p=0.42). CONCLUSION The quality of the available evidence is low. No conclusive evidence was found in order to guide orthodontists in the selection of the best protocol. CLINICAL SIGNIFICANCE Although fixed orthodontic retainers have been used for years in clinical practice, the selection of the best treatment protocol still remains a subjective issue. The available studies, and their synthesis, cannot provide reliable evidence in this field.
Resumo:
AIM To systematically search the literature and assess the available evidence for the influence of chin-cup therapy on the temporomandibular joint regarding morphological adaptations and appearance of temporomandibular disorders (TMD). MATERIALS AND METHODS Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and PubMed), EMBASE (via Ovid), the Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. The reference lists of all eligible studies were checked for additional studies. Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion or the involvement of an arbiter. RESULTS From the 209 articles identified, 55 papers were considered eligible for inclusion in the review. Following the full text reading stage, 12 studies qualified for the final review analysis. No randomized clinical trial was identified. Eight of the included studies were of prospective and four of retrospective design. All studies were assessed for their quality and graded eventually from low to medium level of evidence. Based on the reported evidence, chin-cup therapy affects the condylar growth pattern, even though two studies reported no significance changes in disc position and arthrosis configuration. Concerning the incidence of TMD, it can be concluded from the available evidence that chin-cup therapy constitutes no risk factor for TMD. CONCLUSION Based on the available evidence, chin-cup therapy for Class III orthodontic anomaly seems to induce craniofacial adaptations. Nevertheless, there are insufficient or low-quality data in the orthodontic literature to allow the formulation of clear statements regarding the influence of chin-cup treatment on the temporomandibular joint.
Resumo:
OBJECTIVE To systematically review the reporting of MII (MII) oocyte development after xenotransplantation of human ovarian tissue. DESIGN Systematic review in accordance with the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA). SETTING Not applicable. PATIENT(S) Not applicable. INTERVENTION(S) Formation of MII oocytes after xenotransplantation of human ovarian tissue. MAIN OUTCOME MEASURE(S) Any outcome reported in Pubmed. RESULT(S) Six publications were identified that report on formation of MII oocytes after xenotransplantation of human ovarian tissue. CONCLUSION(S) Xenografting of human ovarian tissue has proved to be a useful model for examining ovarian function and follicle development in vivo. With human follicles that have matured through xenografting, the possibility of cancer transmission and relapse can also be eliminated, because cancer cells are not able to penetrate the zona pellucida. The reported studies have demonstrated that xenografted ovarian tissue from a range of species, including humans, can produce antral follicles that contain mature (MII) oocytes, and it has been shown that mice oocytes have the potential to give rise to live young. Although some ethical questions remain unresolved, xenotransplantation may be a promising method for restoring fertility. This review furthermore describes the value of xenotransplantation as a tool in reproductive biology and discusses the ethical and potential safety issues regarding ovarian tissue xenotransplantation as a means of recovering fertility.
Resumo:
STUDY QUESTION How comprehensive is the recently published European Society of Human Reproduction and Embryology (ESHRE)/European Society for Gynaecological Endoscopy (ESGE) classification system of female genital anomalies? SUMMARY ANSWER The ESHRE/ESGE classification provides a comprehensive description and categorization of almost all of the currently known anomalies that could not be classified properly with the American Fertility Society (AFS) system. WHAT IS KNOWN ALREADY Until now, the more accepted classification system, namely that of the AFS, is associated with serious limitations in effective categorization of female genital anomalies. Many cases published in the literature could not be properly classified using the AFS system, yet a clear and accurate classification is a prerequisite for treatment. STUDY DESIGN, SIZE AND DURATION The CONUTA (CONgenital UTerine Anomalies) ESHRE/ESGE group conducted a systematic review of the literature to examine if those types of anomalies that could not be properly classified with the AFS system could be effectively classified with the use of the new ESHRE/ESGE system. An electronic literature search through Medline, Embase and Cochrane library was carried out from January 1988 to January 2014. Three participants independently screened, selected articles of potential interest and finally extracted data from all the included studies. Any disagreement was discussed and resolved after consultation with a fourth reviewer and the results were assessed independently and approved by all members of the CONUTA group. PARTICIPANTS/MATERIALS, SETTING, METHODS Among the 143 articles assessed in detail, 120 were finally selected reporting 140 cases that could not properly fit into a specific class of the AFS system. Those 140 cases were clustered in 39 different types of anomalies. MAIN RESULTS AND THE ROLE OF CHANCE The congenital anomaly involved a single organ in 12 (30.8%) out of the 39 types of anomalies, while multiple organs and/or segments of Müllerian ducts (complex anomaly) were involved in 27 (69.2%) types. Uterus was the organ most frequently involved (30/39: 76.9%), followed by cervix (26/39: 66.7%) and vagina (23/39: 59%). In all 39 types, the ESHRE/ESGE classification system provided a comprehensive description of each single or complex anomaly. A precise categorization was reached in 38 out of 39 types studied. Only one case of a bizarre uterine anomaly, with no clear embryological defect, could not be categorized and thus was placed in Class 6 (un-classified) of the ESHRE/ESGE system. LIMITATIONS, REASONS FOR CAUTION The review of the literature was thorough but we cannot rule out the possibility that other defects exist which will also require testing in the new ESHRE/ESGE system. These anomalies, however, must be rare. WIDER IMPLICATIONS OF THE FINDINGS The comprehensiveness of the ESHRE/ESGE classification adds objective scientific validity to its use. This may, therefore, promote its further dissemination and acceptance, which will have a positive outcome in clinical care and research. STUDY FUNDING/COMPETING INTERESTS None.
Resumo:
OBJECTIVE AND DESIGN A systematic review of all literature was done to assess the ability of the progestin dienogest (DNG) to influence the inflammatory response of endometriotic cells. MAIN OUTCOME MEASURES In vitro and in vivo studies report an influence of DNG on the inflammatory response in eutopic or ectopic endometrial tissue (animal or human). RESULTS After strict inclusion criteria were satisfied, 15 studies were identified that reported a DNG influence on the inflammatory response in endometrial tissue. These studies identified a modulation of prostaglandin (PG) production and metabolism (PGE2, PGE2 synthase, cyclo-oxygenase-2 and microsomal PGE synthase-1), pro-inflammatory cytokine and chemokine production [interleukin (IL)-1β, IL-6, IL-8, tumor necrosis factor-α, monocyte chemoattractant protein-1 and stromal cell-derived factor-1], growth factor biosynthesis (vascular endothelial growth factor and nerve growth factor) and signaling kinases, responsible for the control of inflammation. Evidence supports a progesterone receptor-mediated inhibition of the inflammatory response in PR-expressing epithelial cells. It also indicated that DNG inhibited the inflammatory response in stromal cells, however, whether this was via a PR-mediated mechanism is not clear. CONCLUSIONS DNG has a significant effect on the inflammatory microenvironment of endometriotic lesions that may contribute to its clinical efficacy. A better understanding of the specific anti-inflammatory activity of DNG and whether this contributes to its clinical efficacy can help develop treatments that focus on the inhibition of inflammation while minimizing hormonal modulation.
Resumo:
OBJECTIVES To systematically review the available literature on the influence of dental implant placement and loading protocols on peri-implant innervation. MATERIAL AND METHODS The database MEDLINE, Cochrane, EMBASE, Web of Science, LILACS, OpenGrey and hand searching were used to identify the studies published up to July 2013, with a populations, exposures and outcomes (PEO) search strategy using MeSH keywords, focusing on the question: Is there, and if so, what is the effect of time between tooth extraction and implant placement or implant loading on neural fibre content in the peri-implant hard and soft tissues? RESULTS Of 683 titles retrieved based on the standardized search strategy, only 10 articles fulfilled the inclusion criteria, five evaluating the innervation of peri-implant epithelium, five elucidating the sensory function in peri-implant bone. Three included studies were considered having a methodology of medium quality and the rest were at low quality. All those papers reported a sensory innervation around osseointegrated implants, either in the bone-implant interface or peri-implant epithelium, which expressed a particular innervation pattern. Compared to unloaded implants or extraction sites without implantation, a significant higher density of nerve fibres around loaded dental implants was confirmed. CONCLUSIONS To date, the published literature describes peri-implant innervation with a distinct pattern in hard and soft tissues. Implant loading seems to increase the density of nerve fibres in peri-implant tissues, with insufficient evidence to distinguish between the innervation patterns following immediate and delayed implant placement and loading protocols. Variability in study design and loading protocols across the literature and a high risk of bias in the studies included may contribute to this inconsistency, revealing the need for more uniformity in reporting, randomized controlled trials, longer observation periods and standardization of protocols.
Resumo:
OBJECTIVES To assess discrepancies in the analyzed outcomes between protocols and published reviews within Cochrane oral health systematic reviews (COHG) on the Cochrane Database of Systematic Reviews (CDSR). STUDY DESIGN AND SETTING All COHG systematic reviews on the CDSR and the corresponding protocols were retrieved in November 2014 and information on the reported outcomes was recorded. Data was collected at the systematic review level by two reviewers independently. RESULTS One hundred and fifty two reviews were included. In relation to primary outcomes, 11.2% were downgraded to secondary outcomes, 9.9% were omitted altogether in the final publication and new primary outcomes were identified in 18.4% of publications. For secondary outcomes, 2% were upgraded to primary, 12.5% were omitted and 30.9% were newly introduced in the publication. Overall, 45.4% of reviews had at least one discrepancy when compared to the protocol; these were reported in 14.5% reviews. The number of review updates appears to be associated with discrepancies between final review and protocol (OR: 3.18, 95% CI: 1.77, 5.74, p<0.001). The risk of reporting significant results was lower for both downgraded outcomes [RR: 0.52, 95% CI: 0.17, 1.58, p = 0.24] and upgraded or newly introduced outcomes [RR: 0.77, 95% CI: 0.36, 1.64, p = 0.50] compared to outcomes with no discrepancies. The risk of reporting significant results was higher for upgraded or newly introduced outcomes compared to downgraded outcomes (RR = 1.19, 95% CI: 0.65, 2.16, p = 0.57). None of the comparisons reached statistical significance. CONCLUSION While no evidence of selective outcome reporting was found in this study, based on the present analysis of SRs published within COHG systematic reviews, discrepancies between outcomes in pre-published protocols and final reviews continue to be common. Solutions such as the use of standardized outcomes to reduce the prevalence of this issue may need to be explored.
Resumo:
OBJECTIVES The main objective was to assess the credibility of the evidence using Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) in oral health systematic reviews on the Cochrane Database of Systematic Reviews (CDSR) and elsewhere. STUDY DESIGN AND SETTING Systematic Reviews or meta-analyses (January 2008-December 2013) from 14 high impact general dental and specialty dental journals and the Cochrane Database of Systematic Reviews were screened for meta-analyses. Data was collected at the systematic review, meta-analysis and trial level. Two reviewers applied and agreed on the GRADE rating for the selected meta-analyses. RESULTS From the 510 systematic reviews initially identified 91 reviews (41 Cochrane and 50 non-Cochrane) were eligible for inclusion. The quality of evidence was high in 2% and moderate in 18% of the included meta-analyses with no difference between Cochrane and non-Cochrane reviews, journal impact factor or year of publication. The most common domains prompting downgrading of the evidence were study limitations (risk of bias) and imprecision (risk of play of chance). CONCLUSION The quality of the evidence in oral health assessed using GRADE is predominantly low or very low suggesting a pressing need for more randomised clinical trials and other studies of higher quality in order to inform clinical decisions thereby reducing the risk of instituting potentially ineffective and/or harmful therapies.