999 resultados para sustentabilidade, eficiência energética
Resumo:
This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016.
Resumo:
O trabalho foi realizado com o objetivo de determinar, pelo método fatorial, as exigências de energia metabolizável (EM) de frangos de corte. Foi conduzido um ensaio em câmaras climáticas mantidas às temperaturas de 13, 23 e 32ºC (±2ºC) para se verificar o efeito da temperatura sobre as exigências de energia metabolizável para mantença utilizando-se a técnica do abate comparativo. As exigências de energia metabolizável para ganho de peso foram determinadas com base no teor de energia corporal e na eficiência energética de utilização da EM. As exigências de mantença foram de 159,36; 116,17 e 128,66 kcal/kg0,75/dia para 13, 23 e 32ºC, respectivamente, verificando-se efeito quadrático da temperatura sobre as exigências de mantença (EMm=300,14 - 14,61.T + 0,2876.T², r²=0,90). As exigências de em para ganho de peso corporal foram de 3,72 kcal/g para machos e 3,98 kcal/g para fêmeas de 1 a 21 dias; 4,21 para machos e 3,93 para fêmeas de 22 a 42 dias; e 4,51 para machos e 7,04 para fêmeas de 43 a 56 dias. Considerando-se as exigências determinadas, foram elaborados modelos de predição das exigências diárias de energia para frangos de corte, nos quais foram considerados o peso corporal, a temperatura ambiente (para estimativa das exigências de mantença) e o ganho de peso (para cálculo das exigências de ganho). Com base nas comparações das exigências determinadas pelos modelos e nas recomendações do manual da linhagem, conclui-se que os modelos elaborados predizem as exigências energéticas dos frangos de corte.
Resumo:
A recuperação da energia térmica do escape afigura-se como uma vertente com importância relevante para o aumento da eficiência energética dos motores de combustão interna, tendo benefícios em termos económicos e ambientais. O presente trabalho centra-se no estudo e dimensionamento do condensador a integrar num sistema de ciclo de Rankine, tendo-se optado pela seleção de um permutador de placas do tipo “chevron”. O permutador para efeitos de cálculo é dividido em três zonas distintas: i) pré-arrefecedor; ii) condensador e iii) sub-arrefecedor. O presente estudo apresenta uma revisão bibliográfica alargada para o coeficiente de transferência de calor por convecção e perda de carga associada ao escoamento. Para cada zona do permutador são utilizados três fluidos de trabalho distintos: água, etanol e R245fa. Para o fluido refrigerante considerou-se água. Tendo em conta a revisão bibliográfica efetuada, foram implementados modelos para a perda de carga e para a transferência de calor no permutador, atendendo à seleção do fluido de trabalho e ao fluido refrigerante. Os resultados obtidos permitiram verificar que a utilização do fluido de trabalho água, conduz a um condensador mais compacto. Por último é efetuada a otimização do sistema, mediante alteração da temperatura de funcionamento do permutador. Os resultados permitiram verificar a diminuição da temperatura de saída do fluido refrigerante possibilita: i) uma redução do volume do permutador; ii) uma diminuição da perda de carga associada.
Resumo:
Com o crescente avanço tecnológico as questões ambientais bem como a eficiência energética assumem cada vez maior relevância e, neste sentido, torna-se imperativo pensar de uma forma mais eficaz e eficiente tanto ao nível ambiental como energético, aliando a eficiência energética a um menor nível dos consumos energéticos. Uma das medidas para melhorar a eficiência energética passa pela construção de edifícios mais eficientes utilizando diversas tecnologias passivas. Assim sendo, este estudo tem por objetivo avaliar o comportamento térmico e as consequências da ventilação numa cobertura em telha cerâmica e subtelha com beiral ventilado, durante os meses de Outono e Inverno. Através de instrumentação diversa colocada numa célula-teste e no ambiente exterior envolvente obtiveram-se diversos dados experimentais relativos a fatores ambientais tais como: temperaturas, humidades relativas, velocidade do ar, radiação solar, entre outros. Fez-se uma avaliação dos dados experimentais recolhidos e da transferência de calor verificada nesses meses. Os resultados mostram que tanto o comportamento térmico bem como a ventilação da caixa-de-ar são fortemente dependentes das condições do ar exterior e da radiação solar, o que tendo em conta os meses de estudo ,permite concluir que a tipologia da cobertura pode não se tornar vantajosa neste período. No entanto, os valores de humidade relativa registados em toda a cobertura bem como no interior da célula demonstram que a ventilação na caixa-de-ar é um fator relevante que contribui para reduzir a possibilidade de ocorrência da condensação do vapor de água contido no ar, ou seja, não existem períodos muito longos com valores de humidade relativa elevados, contribuído para a sua salubridade.
Resumo:
Este documento apresenta os resultados obtidos através do contributo da implementação de um sistema de gestão da energia segundo os critérios e requisitos normativos da ISO 50001:2011, numa unidade industrial de transformação e embalamento de arroz. A aplicação deste referencial normativo deve ter como objetivos apoiar no planeamento das ações decorrentes da gestão de energia, pela monitorização e controlo dos consumos energéticos, bem como, identificar medidas de eficiência energética. Na necessidade da empresa fazer face à previsão do aumento da capacidade produtiva e da redução dos custos associados aos consumos de energia, foi designada uma equipa de gestão de energia que teve como objetivos, a certificação do sistema gestão da energia na empresa e consequentemente, reduzir os custos através de medidas para melhoria da eficiência energética. Os resultados desta implementação foram francamente positivos. Conseguiu-se uma melhoria do desempenho energético em 2015 de 28% face aos valores da primeira medida de gestão da energia, realizada em 2012, ao abrigo da legislação nacional em vigor. O sistema de gestão conseguiu nos primeiros dois anos de execução não só a certificação de conformidade por uma entidade externa, como também, proporcionou à empresa uma redução de 15 % dos valores de consumo específico face aos valores do ano de referência. De um modo geral, a empresa com a implementação deste sistema reduziu os custos energéticos. Esta redução permite aumentar a competitividade no mercado. Assim assegura-se um crescimento da empresa sustentado na gestão de recursos e numa maior diversidade de clientes.
Resumo:
Face aos padrões atuais de vida, em que despendemos a maior parte do nosso tempo no interior de edifícios, com um nível de conforto que ninguém quer abdicar, urge o desenvolvimento de tecnologias de climatização sustentáveis. Devido a uma combinação única de fatores, casas de baixo consumo de energia (e também casas passivas) em Portugal, são particularmente adequadas de explorar as vantagens da energia solar térmica, especialmente quando combinado com armazenamento sazonal de energia. No entanto nenhum exemplo documentado existe de como esta sinergia pode ser explorada com sucesso em Portugal, ilustrando assim o modo em que a necessidade de aquecimento pode ser colmatada de uma forma sustentável sem o uso de combustíveis fósseis. A energia solar é uma excelente alternativa de fonte de energia para aquecimento de edifícios. Um principal fator que limita a sua aplicação é que é uma fonte de energia com uma disponibilidade média de variação cíclica. O uso de armazenamento sazonal de energia pode reduzir substancialmente o custo do sistema solar que é capaz de fornecer até 100% das necessidades energéticas dos edifícios. Estes sistemas são projetados para armazenar a energia solar durante o verão e reter o calor armazenado para posterior utilização durante o inverno; Abstract: SEASONAL SOLAR THERMAL ENERGY STORAGE FOR LOW TEMPERATURE HEATING BUILDINGS. Given the current standards of living, where we spent most of our time inside buildings, with a level of Comfort that no one wants to give up, urges the development of sustainable climate control technologies. Due to a unique combination of factors, low energy (and also passive) houses in Portugal are particularly well suited to exploiting the advantages of solar thermal energy especially when combined with seasonal energy storage. However no documented example there of how this synergy can be exploited successfully in Portugal, illustrating the way in which the need for heating can be addressed in a sustainable manner without the use of fossil fuels. Solar energy is an important alternative energy source for heating applications. One main factor that limits its application is that it is an energy source with an average availability of cyclical variation. The use of seasonal thermal energy storage can substantially reduce the cost of solar energy systems that can supply up to 100% of buildings energy needs. Such systems are designed to collect solar energy during the summer and retain the stored heat for use during the winter.
Resumo:
A tese que se vai apresentar é relativa a um levantamento energético numa empresa de serviços. Colorstar, que se dedica à comercialização e distribuição de produtos químicos, corantes e pigmentos para as indústrias Têxtil, Plásticos e Tintas e que possui nas suas instalações um laboratório para prestação de serviços na área de tinturaria e acabamentos têxteis, estando por isso frequentemente aberta ao contacto com o exterior. O objectivo dessa avaliação energética é permitir à empresa conhecer o seu posicionamento enquanto consumidor de energia, definindo o seu consumo específico de energia e a sua intensidade carbónica e partindo desse conhecimento, poder estabelecer metas relativamente à eficiência do consumo energético da Colorstar, indicando algumas ferramentas que permitam uma racionalização do consumo de energia e consequente poupança na fatura energética. Pretende-se também avaliar a possibilidade de autossustentabilidade energética da empresa e deste modo cumprir a sua política da Qualidade que tem como objectivos a melhoria contínua e a sustentabilidade. Após um primeiro levantamento e análise das faturas de eletricidade dos últimos 2 anos, conclui-se que o consumo da empresa foi de 7,85 tep/ano e de 7,27 tep/ano em 2011. Estes valores de consumo tornam a Colorstar numa empresa não consumidora intensiva de energia (CIE). A área coberta total do edifício onde se situa a empresa é de 503,60 m2. Por estes motivos, o trabalho a ser realizado não será tão exaustivo como o prevê a Legislação no caso de ser uma empresa CIE mas, irá dar especial incidência no levantamento a efetuar ao sector do Laboratório, pois, é lá que se acredita estarem a maior parte dos equipamentos consumidores de eletricidade da empresa e não tem monotorização individual desse consumo. Além disso é também o único sector onde a produção pode ser monitorizada. No presente trabalho foi efetuada a apresentação e caracterização de todo o equipamento com consumo de água e o levantamento da produção na empresa. Em consequência dos resultados desse levantamento foram ainda efetuadas medições no cilindro o que permitiu realizar a desagregação dos consumos de energia na Colorstar e mo sector do Laboratório. Com base nos resultados obtidos conclui-se que o Laboratório é responsável por 34% dos consumos totais de eletricidade na Colorstar sendo assim o maior consumidor da empresa. Segue-se a Climatização com 20%, depois a informática com 18%, os Outros equipamentos com 14% (aqui haverá também uma parcela devido à climatização uma vez que não foi possível calcular o consumo dos aparelhos de Ar Condicionado) e finalmente a Iluminação com um peso de 11% e a Kitchenette (cozinha) com a menor parcela, representa apenas 3% do consumo total da eletricidade na Colorstar. Efetuado também a desagregação dos consumos do Laboratório, concluiu-se que o termoacumulador (cilindro) é o maior consumidor de eletricidade do laboratório com 21% do total, seguindo-se as Máquinas de tingir (19%), Estufas (14%), Máquina de lavar roupa (12%), Placas de Fogão (10%), a Râmula e o Sistema de Exaustão ambos com 6% do consumo total, o Linitest com 5%, o desumidificador com 4%, a Máquina da loiça com 2%, o Espectrofotómetro com 1% e finalmente a Bomba do circuito de Reciclagem da água de arrefecimento das máquinas de tingir com pouco mais que 0%. Em consequência dos resultados do trabalho efetuado, apresentaram-se 3 propostas de melhoria com sugestões para trabalhos futuros.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Dissertação de Mestrado, Engenharia do Ambiente, 12 de Junho de 2014, Universidade dos Açores.
Resumo:
A eficiência de utilização de nutrientes (EUN) e o crescimento de três procedências de Eucalyptus grandis e de três de E. saligna foram avaliados, aos 78 meses de idade, nos municípios de Angatuba, Itapetininga, Paraibuna, São Miguel Aracanjo e São José dos Campos, Estado de São Paulo. Houve variação na produção de biomassa entre os municípios, sendo as maiores produtividades observadas em São Miguel Aracanjo, seguido por Paraibuna, com os demais municípios constituindo um terceiro grupo. Dentro dos municípios não houve diferença entre materiais genéticos na produção de biomassa, exceto em São Miguel Arcanjo. Os materiais genéticos mostraram variações na EUN entre locais. Observou-se maior EUN de E. grandis em relação ao E. saligna para N, P e Mg, não havendo diferenças apreciáveis de eficiência entre as duas espécies para Ca e K. A alta EUN não está necessariamente ligada à alta produtividade. O Ca e o K são os nutrientes que mais poderão limitar a produtividade do próximo ciclo, quando se considera a colheita do tronco. Entretanto, esta limitação pode ser substancialmente reduzida, principalmente para o Ca, se a colheita for realizada apenas do lenho.
Resumo:
O trabalho teve o objetivo de avaliar a demanda energética e a eficiência da distribuição de sementes de uma semeadora-adubadora para semeadura direta, submetida à variação de velocidade e condições de solo, na semeadura da cultura do milho. O estudo foi desenvolvido em um Nitossolo Vermelho distrófico, na Fazenda Experimental Lageado, no município de Botucatu - SP. O delineamento experimental foi em blocos casualizados, com oito repetições, combinando-se três velocidades de deslocamento (4,4; 6,1 e 8,1 km h-1) e duas condições de solo (solo manejado sob sistema de plantio direto há cinco anos e solo preparado com escarificador há 18 meses). Avaliaram-se a força de tração, a potência na barra de tração, o consumo de combustível, a capacidade de campo efetiva, a distribuição longitudinal de plantas, o coeficiente de variação, o índice de precisão e o número de plantas por hectare (estande inicial). Os resultados revelaram que, aumentando-se a velocidade de 4,4 para 8,1 km h-1, consegue-se aumentar em 86% a capacidade operacional, com incremento de 96% na demanda de potência na barra de tração e redução de 26% no consumo operacional de combustível. A maior velocidade (8,1 km h-1) proporcionou menor porcentual de espaçamentos normais e aumento no porcentual de espaçamentos múltiplos e falhos, maior coeficiente de variação e pior índice de precisão. A variação da velocidade não interferiu no número de plantas por hectare.
Resumo:
Mundialmente, dentre todos os setores da economia, o setor elétrico é talvez o que se depare com os maiores desafios em termos de sustentabilidade. Para conseguir manter a sua ‘licença de operação’ junto à sociedade, o setor terá que responder a estes desafios, envolvendo todos os seus diferentes stakeholders e buscando levar em consideração os interesses de cada um deles. O setor elétrico terá também que ser capaz de medir e avaliar sua performance, demonstrando uma melhoria continua em um longo prazo. No nível nacional, o setor elétrico brasileiro já começou a responder a alguns destes desafios, o que pode ser comprovado pelas ações desenvolvidas por algumas das empresas líderes do setor. Este trabalho tem como objetivo contribuir para o entendimento de como o conceito de sustentabilidade está sendo desenvolvido no setor elétrico brasileiro. Mais além, através da proposição de um conjunto de indicadores de sustentabilidade, busca-se estimular a adoção de práticas de sustentabilidade no setor. Estes indicadores, baseados no Triple Bottom Line Ambiental-Social-Econômico, podem ser usados tanto internamente, auxiliando na elaboração de estratégias, quanto externamente, para divulgação de relatórios de sustentabilidade. Como forma de validação da metodologia elaborou-se um estudo de caso para duas das principais empresas do setor elétrico brasileiro.