989 resultados para stranded cable stiffness


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case-control study was conducted to identify risk factors for death from tetanus in the State of Pernambuco, Brazil. Information was obtained from medical records of 152 cases and 152 controls, admitted to the tetanus unit in the State University Hospital, in Recife, from 1990 to 1995. Variables were grouped in three different sets. Crude and adjusted odds ratios, p-values and 95% confidence intervals were estimated. Variables selected in the multivariate analysis in each set were controlled for the effect of those selected in the others. All factors related to the disease progression - incubation period, time elapsed between the occurrence of the first tetanus symptom and admission, and period of onset - showed a statistically significant association with death from tetanus. Similarly, signs and/or symptoms occurring on admission or in the following 24 hours (second set): reflex spasms, neck stiffness, respiratory signs/symptoms and respiratory failure requiring artificial ventilation (third set) were associated with death from tetanus even when adjusted for the effect of the others.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: A presente dissertação para tese de doutoramento apresenta o desenvolvimento e a validação de um método simples e original para o diagnóstico de calcificações vasculares em doentes em diálise, utilizando um score semiquantitativo criado por nós e obtido em RX simples da bacia e das mãos, denominado score de calcifi cação vascular simples. Demonstramos que este score vascular simples é preditor de risco cardiovascular nos doentes em diálise. O score de calcificação vascular simples associou-se ainda à baixa densidade mineral óssea avaliada por dual energy X -ray absortiometry (DXA) no colo do fémur. Verifi camos igualmente que, em doentes em diálise, as calcifi cações coronárias quantifi cadas pelo score de Agatston e o score de calcifi cação vascular simples se associaram a um menor volume ósseo avaliado em biopsias ósseas. Estes trabalhos corroboram a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular nos doentes em diálise, e um dos elementos que contribuem para este elo de ligação podem ser as calcificações vasculares. Este score de calcificação vascular simples avalia calcifi cações em artérias de grande, médio e pequeno calibre, e inclui os dois padrões radiológicos de calcificação: calcificação linear, associada à calcifi cação da camada média da parede arterial, e calcificação irregular, associada à calcifi cação da camada íntima arterial1. Nos diferentes trabalhos por nós publicados demonstramos que as calcificações vasculares avaliadas por este método simples e barato permitem a identificação de indivíduos com elevado risco cardiovascular. Este score vascular associa -se a maior risco de mortalidade cardiovascular2, de mortalidade de causa global3, de internamentos cardiovasculares2, de doença ardiovascular2, de doença arterial periférica2,4,de calcifi cações valvulares5 e de rigidez arterial3. As guidelines KDIGO (Kidney disease: improving global outcomes), publicadas em 2009,sugerem que os doentes renais crónicos nos estadios 3 a 5, com calcificações vasculares e valvulares, devem ser considerados como apresentando o mais elevado risco cardiovascular6. A elevada mortalidade dos doentes renais crónicos não é totalmente explicada pelos fatores de risco tradicionais7. A organização KDIGO defende, desde 2006, a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular8. Esta ligação pode ser explicada pelas alterações do metabolismo mineral e ósseo e pela sua interação com as calcificações vasculares. Verificamos, nos nossos trabalhos, uma associação entre calcifi cações vasculares e doença óssea. O baixo volume ósseo diagnosticado por análise histomorfométrica de biopsias ósseas foi preditor de maior risco de calcificações vasculares avaliadas pelo score de calcifi cação vascular simples (dados apresentados nesta dissertação, no capítulo 6) e pelo score coronário de Agatston num grupo de doentes em diálise9. A contribuição original deste artigo9 foi considerada merecedora de um editorial feito pelo Dr. Gérard London10, investigador líder na área da calcificação vascular dos doentes renais crónicos e actual Presidente da EDTA (European Dialysis and Transplantation Association). Fomos também os primeiros a descrever uma associação independente e inversa entre a densidade mineral avaliada no colo do fémur por DXA (dual energy X -ray absortiometry) com calcificações vasculares avaliadas pelo score de calcificação vascular simples, com rigidez arterial avaliada por velocidade de onda de pulsocarotidofemoral e com doença arterial periférica diagnosticada por critérios clínicos11. Fomos igualmente os primeiros a mostrar uma correlação signifi cativa entre a densidade mineral óssea avaliada por DXA no colo do fémur, mas não na coluna lombar, com a espessura cortical avaliada por análise histomorfométrica em biopsia óssea12. O nosso estudo atribui pela primeira vez à DXA um papel no diagnóstico de porosidade cortical nos doentes em diálise. A utilidade da avaliação diferencial da densidade mineral óssea cortical e trabecular necessita ainda de ser confirmada em estudos prospectivos. Este achado inovador do nosso estudo foi mencionado pela ERBP (European Renal Best Practice) no comentário feito à posição da KDIGO que considera ser reduzida a utilidade da densidade mineral óssea nos doentes em diálise13. Dois dos trabalhos incluídos nesta dissertação foram referenciados nas guidelines KDIGO 2009 para avaliar a prevalência das calcificações vasculares (KDIGO 2009: Tabela suplementar 10, Fig. 3.6) e para validar a associação entre calcificações vasculares e mortalidade cardiovascular (KDIGO 2009: Tabela suplementar 12, Fig. 3.7)6. A inclusão destes nossos dois estudos nas referências destas guidelines, que utilizaram o exigente sistema GRADE (Grades of recommendation, assessment, development, and evaluation) na classificação e selecção dos estudos, valida o interesse científico dos nossos trabalhos. O diagnóstico de calcificações vasculares tem um interesse prático para os doentes renais crónicos. A presença de calcifi cações vasculares é um sinal de alerta para a existência de um elevado risco cardiovascular, e esta informação pode ser utilizada para modificar a terapêutica nestes doentes6. Diferentes métodos podem ser usados para diagnosticar calcificações vasculares nos doentes em diálise14,15. O score de calcificação vascular simples tem a vantagem da simplicidade e de poder ser facilmente interpretado pelo nefrologista, sem necessidade de um radiologista. A reprodutibilidade deste score já foi demonstrada por diferentes grupos em estudos nacionais e internacionais16-24. Nestes estudos foi demonstrado que as calcifi cações vasculares avaliadas pelo método criado por nós são preditoras de maior risco de eventos cardiovasculares16, de amputações dos membros inferiores17, de velocidade de onda de pulso18,19, de calcificações corneanas e conjuntivais20 e de calcifi cações coronárias21. Também foi demonstrada uma associação inversa entre o score de calcificação vascular simples com os níveis séricos de PTH21, com os níveis de 25(OH)vitamina D 22,23 e com os níveis de fetuína A19,24. Todos estes estudos, realizados por diferentes grupos, que utilizaram o score de calcificação vascular simples na sua metodologia, comprovam a facilidade de utilização deste score e a concordância de resultados atestam a sua reprodutibilidade e a utilidade na avaliação dos doentes renais crónicos. ---------------------------ABSTRACT: This thesis presents the development and validation of a simple and original method to identify vascular calcifications in dialysis patients, using a semi -quantitative score that we have created and that is obtained in plain X -ray of pelvis and hands. This score was named in different publications as “simple vascular calcifi cation score”. We have demonstrated that this score is a predictor of higher cardiovascular risk in dialysis patients. The simple vascular calcification score was also associated with lower mineral bone density evaluated by DXA in femoral neck. In hemodialysis patients coronary calcifications evaluated by the coronary Agatston score and by the simple vascular calcification score were associated with lower bone volume analysed in bone biopsies. These studies corroborate the hypothesis of the existence of a link between bone disease and vascular disease in dialysis patients and one of the elements of this link may be vascular calcifications. This simple vascular calcification score identifi es calcifications in large, medium and small calibre arteries and includes the two radiological patterns of arterial calcifi cation: linear calcification which has been associated with the calcifi cation of the media layer of the arterial wall and irregular and patchy calcification which has been associated with the calcifi cation of the intima layer of the arterial wall1. In the several studies that we have published we have demonstrated that vascular calcifications evaluated by this simple and inexpensive method allow the identification of patients with high cardiovascular risk. This simple vascular calcification score is an independent predictor of cardiovascular mortality2, all -cause mortality3, cardiovascular hospitalizations2, cardiovascular disease2, peripheral artery disease2,4, valvular calcifi cations5 and arterial stiffness3.KDIGO (Kidney Disease: Improving Global Outcomes) guidelines published in 2009 suggest that chronic kidney disease patients in stages 3 to 5, with vascular and valvular calcifications should be considered to be at the highest cardiovascular risk6. The high mortality of chronic kidney disease patients is not completely explained by the traditional risk factors7 and KDIGO group supports, since 2006, the hypothesis of the existence of a link between bone disease and vascular disease8.This link may be explained by the alterations of the bone and mineral metabolism and their interaction with development and progression of vascular calcifications. We have also verifi ed in our studies the existence of an association between vascular calcifications and bone disease. Low bone volume diagnosed by histomorphometric analysis of bone biopsies, in a group of dialysis patients, was independently associated with the simple vascular calcification score (data presented in this thesis,chapter 6) and with coronary calcifications evaluated by the Agatston score9. The original contribution of this article published in CJASN9 deserved a commentary in an Editorial written by Prof. Gérard London10 leader investigator in this area and current EDTA (European Dialysis and Transplantation Association) President. We were also the fi rst group to describe an independent and inverse association between bone mineral density evaluated in the femoral neck by DXA (dual energy X -ray absortiometry) with vascular calcifications evaluated by the simple vascular calcification score, with arterial stiffness evaluated by carotid-femoral pulse wave velocity and with peripheral artery disease diagnosed by clinical criteria11. We were also the first group to demonstrate a significant correlation between bone mineral density evaluated by DXA in femoral neck but not in lumbar spine, with cortical thickness evaluated by histomorphometric analysis of bone biopsy12. Our study has attributed to DXA, for the first time, a role in the diagnosis of cortical porosity in dialysis patients. The clinical utility of the differential evaluation of bone mineral density in cortical or trabecular bone needs, however, to be confi rmed in prospective studies. This original fi nding of our study was mentioned by ERBP (European Renal Best Practice) commenting the KDIGO position in relation with the reduced utility of bone mineral density evaluation in dialysis patients13. Two of the studies included in this thesis have been integrated in a group of studies selected as references by the KDIGO guidelines published in 2009 to evaluate the prevalence of vascular calcifications in CKD patients (KDIGO 2009: Supplementary Table 10, Fig. 3.6) and to corroborate the association between vascular calcifications and cardiovascular mortality (KDIGO 2009: Supplementary Table 12, Fig. 3.7)6. The inclusion of both studies as references in the KDIGO guidelines that have used the exigent GRADE system (Grades of Recommendation, Assessment, Development, and Evaluation) in the classifi cation and selection of studies, validates the scientifi c value of our studies. The diagnosis of vascular calcifi cations has a practical interest for chronic kidney disease patients. The presence of vascular calcifications is an alert sign to the existence of a high cardiovascular risk and this information may be used to modify the treatment of these patients6. Different methods may be used to detect the presence of vascular calcifications in dialysis patients14,15. The simple vascular calcifi cation score has the advantage of being simple, inexpensive and easily evaluated by the Nephrologist without the need for a Radiologist interpretation. The reproducibility of this method has already been demonstrated by other groups in national and international studies16 -24. It was demonstrated in those studies that vascular calcifi cations evaluated by the method created by us, predict higher risk of cardiovascular events16, higher risk of lower limbs amputations17, higher pulse wave velocity18,19, corneal and conjuntival calcifi cations 20 and coronary calcifi cations21. A negative association between the simple vascular calcification score and PTH levels21, 25(OH) vitamin D levels22,23 and Fetuin A levels19,24 has also been demonstrated. All these studies performed by different groups that have used the simple vascular calcifi cation score in their methods demonstrate that this score is simple, useful and reproducible in the evaluation of chronic kidney disease patients simple, useful and reproducible in the evaluation of chronic kidney disease patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increased demands on the capacity of the railway network gave rise to new issues related to the dynamic response of railway tracks subjected to moving vehicles. Thus, it becomes important to evaluate the applicability of traditionally used simplified models which have a closed form solution. Regarding simplified models, transversal vibrations of a beam on a visco-elastic foundation subjected to a moving load are considered. Governing equations are obtained by Hamilton’s principle. Shear distortion, rotary inertia and effect of axial force are accounted for. The load is introduced as a time varying force moving at a constant velocity. Transversal vibrations induced by the load are solved by the normal-mode analysis. Reflected waves at the extremities of the full beam are avoided by introduction of semi-infinite elements. Firstly, the critical velocity obtained from this model is compared with results of an undamped Euler- Bernoulli formulation with zero axial force. Secondly, a finite element model in ABAQUS is examined. The new contribution lies in the introduction of semi- infinite elements and in the first step to a systematic comparison, which have not been published so fa

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper is to characterize complaints in the upper limbs, shoulders, neck and back- lumbar region directly related to musculo-skeletal disorders in a sampling of 114 cleaners from seven cleaning (janitor) companies, operating at eight client organizations. Complaints had been diagnosed as stiffness, any pain, numbness, paraesthesiae, tingling, cold feeling and blanching of at least one finger tip, according to a temporal criteria of symptoms were present now or have been present on at least 4 days during the last 7 days, or symptoms have been present on at least 4 days during at least one week in the last 12 months. It was analyzed the severity of the complaints (interference with current activities) and the simultaneous occurrence of multiple symptoms. The causes of medical consultation in the last year were analyzed (osteo-articular pathology of the vertebral spine, of the upper and lower limbs, depressive syndromes and other complaints of the lower limbs among others). In the end, the relation between persistent complaints and musculo- skeletal pathology related to work activities was analyzed, considering particularly the age of the workers and the existence of osteo-articular pathology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transversal vibrations induced by a load moving uniformly along an infinite beam resting on a piece-wise homogeneous visco-elastic foundation are studied. Special attention is paid to the additional vibrations, conventionally referred to as transition radiations, which arise as the point load traverses the place of foundation discontinuity. The governing equations of the problem are solved by the normalmode analysis. The solution is expressed in a form of infinite sum of orthogonal natural modes multiplied by the generalized coordinate of displacement. The natural frequencies are obtained numerically exploiting the concept of the global dynamic stiffness matrix. This ensures that the frequencies obtained are exact. The methodology has restrictions neither on velocity nor on damping. The approach looks simple, though, the numerical expression of the results is not straightforward. A general procedure for numerical implementation is presented and verified. To illustrate the utility of the methodology parametric optimization is presented and influence of the load mass is studied. The results obtained have direct application in analysis of railway track vibrations induced by high-speed trains when passing regions with significantly different foundation stiffness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this contribution is to extend the techniques of composite materials design to non-linear material behaviour and apply it for design of new materials for passive vibration control. As a first step a computational tool allowing determination of macroscopic optimized one-dimensional isolator behaviour was developed. Voigt, Maxwell, standard and more complex material models can be implemented. Objective function considers minimization of the initial reaction and/or displacement peak as well as minimization of the steady-state amplitude of reaction and/or displacement. The complex stiffness approach is used to formulate the governing equations in an efficient way. Material stiffness parameters are assumed as non-linear functions of the displacement. The numerical solution is performed in the complex space. The steady-state solution in the complex space is obtained by an iterative process based on the shooting method which imposes the conditions of periodicity with respect to the known value of the period. Extension of the shooting method to the complex space is presented and verified. Non-linear behaviour of material parameters is then optimized by generic probabilistic meta-algorithm, simulated annealing. Dependence of the global optimum on several combinations of leading parameters of the simulated annealing procedure, like neighbourhood definition and annealing schedule, is also studied and analyzed. Procedure is programmed in MATLAB environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO:Os microrganismos reagem à súbita descida de temperatura através de uma resposta adaptativa específica que assegura a sua sobrevivência em condições desfavoráveis. Esta adaptação inclui alterações na composição da membrana, na maquinaria de tradução e transcrição. A resposta ao choque térmico pelo frio induz uma repressão da transcrição. No entanto, a descida de temperatura induz a produção de um grupo de proteínas específicas que ajudam a ajustar/re-ajustar o metabolismo celular às novas condições ambientais. Em E. coli o processo de adaptação demora apenas quatro horas, no qual um grupo de proteínas específicas são induzidas. Depois desde período recomeça lentamente a produção de proteínas.A ribonuclease R, uma das proteínas induzidas durante o choque térmico pelo frio, é uma das principais ribonucleases em E. coli envolvidas na degradação do RNA. É uma exoribonuclease que degrada RNA de cadeia dupla, possui funções importantes na maturação e “turnover” do RNA, libertação de ribossomas e controlo de qualidade de proteínas e RNAs. O nível celular desta enzima aumenta até dez vezes após exposição ao frio e estabiliza em células na fase estacionária. A capacidade de degradar RNA de dupla cadeia é importante a baixas temperaturas quando as estruturas de RNA estão mais estáveis. No entanto, este mecanismo é desconhecido. Embora a resposta específica ao “cold shock” tenha sido descoberta há mais de duas décadas e o número de proteínas envolvidas sugerirem que esta adaptação é rápida e simples, continuamos longe de compreender este processo. No nosso trabalho pretendemos descobrir proteínas que interactuem com a RNase R em condições ambientais diferentes através do método “TAP-tag” e espectrometria de massa. A informação obtida pode ser utilizada para deduzir algumas das novas funções da RNase R durante a adaptação bacteriana ao frio e durante a fase estacionária. Mais importante ainda, RNase R poderá ser recrutada para um complexo de proteínas de elevado peso molecular durante o “cold-shock”.------------ABSTRACT:Microorganisms react to the rapid temperature downshift with a specific adaptative response that ensures their survival in unfavorable conditions. Adaptation includes changes in membrane composition, in translation and transcription machinery. Cold shock response leads to overall repression of translation. However, temperature downshift induces production of a set of specific proteins that help to tune cell metabolism and readjust it to the new environmental conditions. For Escherichia coli the adaptation process takes only about four hours with a relatively small set of specifically induced proteins involved. After this time, protein production resumes, although at a slower rate. One of the cold inducible proteins is RNase R, one of the main E. coli ribonucleases involved in RNA degradation. RNase R is an exoribonuclease that digest double stranded RNA, serves important functions in RNA maturation and turnover, release of stalled ribosomes by trans-translation, and RNA and protein quality control. The level of this enzyme increases about ten-fold after cold induction, and it is also stabilised in cells growing in stationary phase. The RNase R ability to digest structured RNA is important at low temperatures where RNA structures are stabilized but the exact role of this mechanism remains unclear. Although specific bacterial cold shock response was discovered over two decades ago and the number of proteins involved suggests that this adaptation is fast and simple, we are still far from understanding this process. In our work we aimed to discover the proteins interacting with RNase R in different environmental conditions using TAP tag method and mass spectrometry analysis. The information obtained can be used to deduce some of the new functions of RNase R during adaptation of bacteria to cold and in stationary growth phase. Most importantly RNase R can be recruited into a high molecular mass complex of protein in cold shock.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 5-year-old female developed, after a 7-month period of fever, anorexia, weight loss, and a transitory cutaneous erythematous eruption, a severe acute transverse myelopathy, with a partial recovery of motor and sensory function. She had positive antinuclear and antidouble-stranded DNA antibodies but no antiphospholipid antibodies. Six months later she had massive proteinuria and restarted treatment with steroids and cyclophosphamide. Our patient is one of the youngest reported with lupus myelopathy. We discuss the clinical presentation, the magnetic resonance imaging findings, and other relevant laboratory studies of this rare but serious complication of systemic lupus erythematosus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seroprevalence of HCMV in Costa Rica is greater than 95% in adults; primary infections occur early in life and is the most frequent congenital infection in newborns. The objectives of this study were to determine the genetic variability and genotypes of HCMV gB gene in Costa Rica. Samples were collected from alcoholics, pregnant women, blood donors, AIDS patients, hematology-oncology (HO) children and HCMV isolates from neonates with cytomegalic inclusion disease. A semi-nested PCR system was used to obtain a product of 293-296 bp of the gB gene to be analyzed by Single Stranded Conformational Polymorphism (SSCP) and sequencing to determine the genetic polymorphic pattern and genotypes, respectively. AIDS patients showed the highest polymorphic diversity with 14 different patterns while fifty-six percent of HO children samples showed the same polymorphic pattern, suggesting in this group a possible nosocomial infection. In neonates three genotypes (gB1, gB2 and gB3), were determined while AIDS patients and blood donors only showed one (gB2). Of all samples analyzed only genotypes gB1, 2 and 3 were determined, genotype gB2 was the most frequent (73%) and mixed infections were not detected. The results of the study indicate that SSCP could be an important tool to detect HCMV intra-hospital infections and suggests a need to include additional study populations to better determine the genotype diversity and prevalence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As ligações adesivas são frequentemente utilizadas na fabricação de estruturas complexas que não poderiam ou não seriam tão fáceis de ser fabricadas numa só peça, a fim de proporcionar uma união estrutural que, teoricamente, deve ser pelo menos tão resistente como o material de base. As juntas adesivas têm vindo a substituir métodos como a soldadura, e ligações parafusadas e rebitadas, devido à facilidade de fabricação, menor custo, facilidade em unir materiais diferentes, melhor resistência, entre outras características. Os materiais compósitos reforçados com fibra de carbono são amplamente utilizados em muitas indústrias, tais como de construção de barcos, automóvel e aeronáutica, sendo usados em estruturas que requerem elevada resistência e rigidez específicas, o que reduz o peso dos componentes, mantendo a resistência e rigidez necessárias para suportar as diversas cargas aplicadas. Embora estes métodos de fabricação reduzam ao máximo as ligações através de técnicas de fabrico avançadas, estas ainda são necessárias devido ao tamanho dos componentes, limitações de projecto tecnológicas e logísticas. Em muitas estruturas, a combinação de compósitos com metais tais como alumínio ou titânio traz vantagens de projecto. Este trabalho tem como objectivo estudar, experimentalmente e por modelos de dano coesivo (MDC), juntas adesivas em L entre componentes de alumínio e compósito de carbono epóxido quando solicitados a forças de arrancamento, considerando diferentes configurações de junta e adesivos de ductilidade distinta. Os parâmetros geométricos abordados são a espessura do aderente de alumínio (tP2) e comprimento de sobreposição (LO). A análise numérica permitiu o estudo da distribuição das tensões, evolução do dano, resistência e modos de rotura. Os testes experimentais validam os resultados numéricos e fornecem mecanismos de projecto para juntas em L. Foi mostrado que a geometria do aderente em L (alumínio) e o tipo de adesivo têm uma influência directa na resistência de junta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Electromyography (EMG) is an important tool for gait analyzes and disorders diagnoses. Traditional methods involve equipment that can disturb the analyses, being gradually substituted by different approaches, like wearable and wireless systems. The cable replacement for autonomous systems demands for technologies capable of meeting the power constraints. This work presents the development of an EMG and kinematic data capture wireless module, designed taking into account power consumption issues. This module captures and converts the analog myoeletric signal to digital, synchronously with the capture of kinetic information. Both data are time multiplexed and sent to a PC via Bluetooth link. The work carried out comprised the development of the hardware, the firmware and a graphical interface running in an external PC. The hardware was developed using the PIC18F14K22, a low power family of microcontrollers. The link was established via Bluetooth, a protocol designed for low power communication. An application was also developed to recover and trace the signal to a Graphic User Interface (GUI), coordinating the message exchange with the firmware. Results were obtained which allowed validating the conceived system in static and with the subject performing short movements. Although it was not possible to perform the tests within more dynamic movements, it is shown that it is possible to capture, transmit and display the captured data as expected. Some suggestions to improve the system performance also were made.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação teve como objetivo fazer uma análise da viabilidade técnica da utilização dos condutores de alta temperatura nas linhas aéreas de MT, identificar vantagens, analisar inconvenientes, e estabelecer um comparativo a custos médios com as soluções convencionais. Foi efetuado o estudo de um caso real da EDP Distribuição que consistia na necessidade do aumento da capacidade de transporte de energia da linha aérea a 15 kV Espinho-Sanguedo. Neste foi ponderada a solução onde se poderia efetuar passagem de linha simples para linha dupla em alumínio-aço (AA) 160 mm2 ou a solução alternativa e inovadora de substituição dos condutores existentes por condutores de alta temperatura ACCC 182 mm2. Para isso foram efetuados cálculos e também criada uma ferramenta de apoio à decisão, para validação dos mesmos, com o intuito de mais tarde poder ser aplicada nas linhas aéreas em Média Tensão em todo o país e, sempre que necessário, se possa fazer um estudo de ponderação técnica de forma sistemática e estruturada. Neste trabalho estão identificadas as vantagens, foram relatados os inconvenientes, e estabeleceu-se um comparativo a custos médios da utilização de condutores de alta temperatura com as soluções convencionais. Antes de poder ser realizado um estudo do caso concreto da Linha aérea Espinho-Sanguedo foi necessário um aprofundamento do estado da arte no que diz respeito à comparação entre o cabo de alta temperatura ACCC e o cabo convencional ACSR, sendo este o mais utilizado nas linhas aéreas em MT. Os cabos de alta temperatura trouxeram inovações neste tema de transporte de energia, e como tal surgiu a necessidade de um estudo mais aprofundado da sua constituição, destacando o seu núcleo formado pelo compósito de fibra de carbono e fibra de vidro. Foi também analisado vantagens e desvantagens do cabo de alta temperatura e até mesmo situações onde a sua aplicação poderá ser vantajosa, de modo a tirar proveito das suas caraterísticas em que se destacam altas temperaturas de funcionamento e flechas reduzidas. Para elaborar um projeto de uma linha aérea em média tensão é necessário considerar a legislação em vigor, os aspetos ambientais e económicos, respeitando e garantindo as premissas do cálculo elétrico e mecânico. Economicamente este tipo de cabo (ACCC) é mais dispendioso do que os convencionais, no entanto o estudo realizado permitiu perceber que a sua implementação técnica é vantajosa em linhas aéreas de elevada capacidade de transporte de energia, sobretudo nos casos onde serão necessárias instalar linhas duplas ou linhas simples de seções elevadas. Devido às suas caraterísticas mecânicas, estes cabos permitem melhorar as linhas na sua dimensão, podendo diminuir o número de apoios a instalar, podendo diminuir a robustez dos apoios e permitir maior facilidade na montagem. Estas vantagens traduzem-se em menores impactos ambientais e permitem sobretudo reduzir os constrangimentos com os proprietários dos terrenos onde os apoios são implantados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the behaviour of two structural adhesives modified with thermally expandable particles (TEPs) was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the adhesives and TEPs-modified adhesives. In order to determine the expansion temperature of the particles while encapsulated in these particular adhesive systems, the variation of the volume of adhesive samples modified with different TEPs concentration as a function of temperature was measured. Further, the possibility of any chemical interactions between TEPs and adhesives matrix in the TEPs-modified specimens was verified by a Fourier transform infrared spectroscopy analysis. Finally, the fracture surfaces of the unmodified and TEPs-modified specimens, as well as the dispersion and the morphology of the particles, were examined by a scanning electron microscopy analysis. It was found that the stiffness of the TEPs-modified adhesives is not affected by incorporation of TEPs in the adhesives matrix, while the tensile yield strength decreased by increasing the wt% TEPs content. In applications of such particular materials (TEPs-modified adhesives), the temperature should be controlled to stay between 90°C and 120°C in order to obtain the highest expansion ratio. At a lower temperature, not all the particles will expand, and above, the TEPs will deteriorate and as a result the TEPs-modified adhesives will deteriorate.