944 resultados para pre-natal care


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pre-eclampsia (PE) is associated with decreased nitric oxide (NO) formation. However, no previous study has examined whether genetic variations in the endothelial NO synthase (eNOS) affect this alteration. We hypothesized that PE decreases NO formation depending on eNOS polymorphisms. We examined how three eNOS polymorphisms [T-786C, rs2070744; Glu298Asp, rs1799983; 27 bp variable number of tandem repeats (VNTR) in intron 4] affect plasma nitrite concentrations in 205 pregnant women [107 healthy pregnant (HP) and 98 PE]. Genotypes were determined and eNOS haplotypes were inferred using the PHASE 2.1 program. The plasma nitrite concentrations were determined using an ozone-based chemiluminescence assay. The Glu298Asp polymorphism had no effects on the plasma nitrite concentrations. Higher nitrite levels were found in HP women with the CC versus TT genotype for the T-786C polymorphism (277.9 +/- 19.5 versus 140.6 +/- 8.2 nM; P < 0.05). Lower nitrite levels were found in healthy women with the 4a4a versus 4b4b genotype for the VNTR polymorphism (95.1 +/- 3.3 versus 216.1 +/- 16.8 nM; P < 0.05). No effects of genotypes were found in PE women (all P > 0.05). The `C Glu b` haplotype was more frequent in the HP group than in the PE group (20 versus 5; P = 0.0044). This haplotype was associated with higher nitrite concentrations than the other haplotypes in healthy pregnancies (P < 0.05). No differences in nitrite concentrations were found among PE women with different eNOS haplotypes (P > 0.05). These findings indicate that eNOS polymorphisms affect endogenous NO formation in normal pregnancy, but not in PE, and that the `C Glu b` haplotype may protect against the development of PE by increasing endogenous NO formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Examination of the epidemiology and timing of trauma deaths has been deemed a useful method to evaluate the quality of trauma care. Objective: The purpose of this study was to evaluate the quality of trauma care in a regional trauma system and in a university hospital in Brazil by comparing the timing of deaths in the studied prehospital and in-hospital settings to those published for trauma systems in other areas. Methods: We analyzed the National Health Minister`s System of Deaths Information for the prehospital mortality and we retrospectively collected the demographics, timelines, and trauma severity scores of all in-hospital patients who died after admission through the Emergency Unit of Hospital das Clinicas de Ribeirao Preto between 2000 and 2001. Results. During the study period, there were 787 trauma fatalities in the city: 448 (56.9%) died in the prehospital setting and 339 (43.1%) died after being admitted to a medical facility. In 2 years, 238 trauma deaths occurred in the studied hospital, and we found a complete clinical set of data for 224 of these patients. The majority of deaths in the prehospital setting were caused by penetrating injuries (66.7%), whereas in-hospital mortality was mainly because of blunt traumas (59.1%). The largest number of in-hospital deaths occurred beyond 72 hours of stay (107 patients-47%). Conclusions: The region studied showed some deficiencies in prehospital and in-hospitals settings, in particular in the critical care and short-term follow-up of trauma patients when compared with the literature. Particularly, the late mortality may be related to training and human resources deficiency. Based on the timeline of trauma deaths, we can suggest that the studied region needs improvements in the prehospital trauma system and in hospital critical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian emergency system is being reorganized as a hierarchy in the region of Ribeirao Preto, state of Sao Paulo. We found increased occupational risk for tuberculosis in this region tertiary reference center-a nurse technician (Incidence rate [IR] 526.3/100000 inhabitants) had a risk of tuberculosis 12.6 (95% confidence interval [CI], 2.57-37.23) greater than the city population (41.8/100000 inhabitants). The system reorganization will have to make the centers adequate to deal with this problem. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on the views of Primary Health Care (PHC) providers in Southeast Brazil on the use of alcohol and other drugs which reflect stigma, moralization, or negative judgment. Six hundred nine PHC professionals from the Brazilian states of Sao Paulo and Minas Gerais took part in the study. The majority (86.5%) of these professionals were female. Attitudes toward the use of alcohol and other drugs were evaluated in comparison to Hansen`s disease, obesity, depression, schizophrenia. HIV/AIDS, and tobacco use. The use of tobacco, marijuana/cocaine, and alcohol were the most negatively judged behaviors (p < 0.05). Nursing assistants and community health care workers demonstrated the severest judgment of alcohol use. In addition, marijuana/cocaine addicts and alcoholics suffered the highest rate of rejection by professionals. The hypothesis that the use of alcohol and other drugs is a behavior stigmatized by health professionals being confirmed, it is important to develop strategies for changing provider attitudes in order to provide a higher quality of service to these patients. This study is important as a first study among PHC professionals about social stigma of alcohol and other drugs users. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. This study aimed to assess the discriminative validity of the Brazilian version of the Patient Health Questionnaire (PHQ-9) and of its reduced version (PHQ-2). DESIGN AND METHODS. The sample consisted of 177 women (60 cases of depression and 117 noncases). The SCID-IV was used as the gold standard. FINDINGS. For the PHQ-9, a cutoff score equal to or higher than 10 proved to be the most adequate for the screening of depression, whereas the best cutoff score for the PHQ-2 was found to lie between 3 and 4. PRACTICE IMPLICATIONS. The systematic use of these instruments in nursing and in the context of primary health care could favor the early detection of depression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the validity and applicability of the Mini International Neuropsychiatric Interview (MINI) used by family medicine residents in primary health care (PHC) in Brazil. Methods: Training for administrating the MINI was given as part of a broad psychiatry education program. Interviews were held with 120 PHC patients who were at least 15 years old. MINI was administered by 25 resident physicians, while the Structured Clinical Interview for Diagnosis (SCID) was administered by a psychiatrist blind to patients` results on the MINI, and the diagnoses on both interviews were compared. The resident physicians answered questions on the applicability of the MINI. Results: Concordance levels for any mental disorder, the broader current diagnostic categories and the most common specific diagnoses were analyzed. Kappa coefficients ranged between 0.65 and 0.85; sensitivity, between 0.75 and 0.92; specificity, between 0.90 and 0.99; positive predictive values (PPV), between 0.60 and 0.86; negative predictive values (NPV), between 0.92 and 0.99; and accuracy, between 0.88 and 0.98. The resident physicians considered MINI comprehensibility and clinical relevance satisfactory. Conclusions: These good psychometric results in a real-world setting may be related to a special training program, which is more frequent, intensive and diversified. In these conditions, the MINI is a useful tool for general practitioners. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Purpose of this study was: (a) to assess and to compare anxiety and depression symptoms in mothers of preterm neonates during hospitalization in the Neonatal Intenive Care Unit, after discharge, and at the end of the infants` first year of life and (b) to assess the child`s development at 12 months of chronological corrected age (CCA). Thirty-six mothers, with no psychiatric antecedents assessed with the SCID-NP were evaluated by STAI and BDI The infants were assessed with Bayley-II Scales. There was a significant decrease in clinical symptoms of state-anxiety in mothers (p =.008). comparing the period during hospitalization and after discharge of the infants. Clinical symptoms of anxiety and depression were observed in 20% of the mothers at the end of the infants` first year of age. The majority of the infants exhibited normal development on Bayley-II at 12 months CCA: however. 25% of the infants displayed cognitive problems and 40% motor problems. The mothers` anxiety and depression symptoms decreased it the end of the first year of life of the pre-term infants and the children showed predominately normal development Lit this phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vascular endothelial growth factor (VEGF) is relevant for normal pregnancy, and abnormalities in VEGF functions are associated with hypertensive disorders of pregnancy. Because there are few studies on how VEGF genetic polymorphisms affect susceptibility to pre-eclampsia (PE), and no studies on how they affect susceptibility to gestational hypertension (GH), we compared VEGF genotype and haplotype distributions in normotensive and hypertensive pregnancies. Genotypes and haplotypes for VEGF polymorphisms (C-2578A, G-1154A and G-634C) were determined in 303 pregnant women (108 healthy pregnant, HP; 101 with GH and 94 with PE). When white and non-white pregnant women were considered together, no significant differences were found in the distributions of VEGF genotypes or haplotypes (P > 0.05) in the three groups. However, with only white subjects, significant differences were found in genotypes distributions for two (C-2578A and G-634C) VEGF polymorphisms (both P < 0.05) between the HP and the PE groups. Importantly, the haplotype including the variants C-2578, G-1154 and C-634, which is associated with higher VEGF gene expression, was less common in the PE group compared with the HP group (4% versus 16%; P = 0.0047). However, we found no significant differences in VEGF haplotypes distributions when the HP and GH groups were compared (P > 0.05). These findings suggest a protective effect for the `C-2578, G-1154 and C-634` haplotype against the development of PE, but no major effects of VEGF gene variants on susceptibility to GH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the behavioral and physiological reactivity of preterm neonates during different phases of a blood collection procedure involving arterial puncture. The sample consisted of 43 preterm and very low birth weight neonates with a postnatal age of 1 to 21 days who were hospitalized in the Neonatal Intensive Care Unit. The neonates were evaluated during the whole blood collection procedure. The assessment was divided into five consecutive phases: Baseline (BL); Antispsis (A), covering the period of handling of the neonate for antisepsis prior to puncture; Puncture (P): Recovery-Dressing (RD), covering the period of handling of the neonate for dressing until positioning for rest in the isolette; and Recovery-Resting (RR). Facial activity was videotaped and analyzed using the National Facial Coding System (NFCS). The sleep-wake state and heart rate were registered at the bedside. There was a significant increases in NFCS score and heart rate, and more active behavior during phases A, P, and RD relative to BL. Regarding the tactile stimulation of the infant in pre-puncture (A) and post-puncture (RD), it was observed increased NFCS score, heart rate, and active behavior in comparison to the BL an BR phases. There was evidence of distress responses immediately before and after a painful event, quite apart form the pain reaction to the puncture procedure. Published by Elsevier B.V. on behalf of International Association for the Study of Pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.