884 resultados para polishing filtration


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the fruit extracts of Morus nigra - mulberry, Syzygium cuminii - jambolão, Vitis vinifera ¾ grape, Myrciaria cauliflora - jabuticaba are suggested as pH indicators in the form of either solutions or paper. The pH indicator solutions were prepared by soaking the fruits or their peels in ethanol 1:3 (m/V) for 24 h, followed by simple filtration. The pH indicator papers were prepared by imersion of the qualitative filter paper strips in the pH indicator solutions. The different pH leads to color changes in the indicator solutions or papers and it can be used for teaching elementary chemistry concepts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The abatement of recalcitrant lignin macromolecules from effluents of pulp and paper industry was investigated by combined process. Flocculation and coagulation with aluminum sulfate and natural polyelectrolytes extracted from cactus Cereus peruvianus were used in the first step. After separation of solid residues by filtration, the photochemical methods using TiO2 as catalyst were employed for photocatalytic degradation of lignin compounds from solution. The abatement of lignin compounds after flocculation and coagulation was 46%, and after the overall process, the pollutants reduction observed were 66%. The remaining organic compounds may be removed by any biological treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanofiltration performance was studied with effluents from the pulp and paper industry and with model substances. The effect of filtration conditions and membrane properties on nanofiltration flux, retention, and fouling was investigated. Generally, the aim was to determine the parameters that influence nanofiltration efficiency and study how to carry out nanofiltration without fouling by controlling these parameters. The retentions of the nanofiltration membranes studied were considerably higher than those of tight ultrafiltration membranes, and the permeate fluxes obtained were approximately the same as those of tight ultrafiltration membranes. Generally, about 80% retentions of total carbon and conductivity were obtained during the nanofiltration experiments. Depending on the membrane and the filtration conditions, the retentions of monovalent ions (chloride) were between 80 and 95% in the nanofiltrations. An increase in pH improved retentions considerably and also the flux to some degree. An increase in pressure improved retention, whereas an increase in temperature decreased retention if the membrane retained the solute by the solution diffusion mechanism. In this study, more open membranes fouled more than tighter membranes due to higher concentration polarization and plugging of the membrane material. More irreversible fouling was measured for hydrophobic membranes. Electrostatic repulsion between the membrane and the components in the solution reduced fouling but did not completely prevent it with the hydrophobic membranes. Nanofiltration could be carried out without fouling, at least with the laboratory scale apparatus used here when the flux was below the critical flux. Model substances had a strong form of the critical flux, but the effluents had only a weak form of the critical flux. With the effluents, some fouling always occurred immediately when the filtration was started. However, if the flux was below the critical flux, further fouling was not observed. The flow velocity and pH were probably the most important parameters, along with the membrane properties, that influenced the critical flux. Precleaning of the membranes had only a small effect on the critical flux and retentions, but it improved the permeability of the membranes significantly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin hitsaamalla valmistettavan kerrossihtilevyn soveltuvuutta eri sellutehtaan laitteisiin mekaanisen kuormituskokeen, korroosiokokeen ja syrjäytyskokeiden avulla. Tutkimusympäristönä käytettiin puukuitupesuria, sillä kerrossihtilevyrakenteen todennäköisimpiä käyttökohteita ovat erilaiset massan pesuun tarkoitetut laitteet. Mekaanisen kuormituksen kokeessa tarkasteltiin kerrossihtilevyn staattista ja dynaamista kuormituksen kestoa painevaihteluiden avulla pesurin koelokerossa ja verrattiin sitä porattuun reikälevyyn. Kokeessa käytetyn kerrossihtilevyversion todettiin olevan huomattavasti porattua saman paksuista reikälevyä heikompi dynaamisen kuormituksen alaisena. Syrjäytyskokeilla määritettiin syrjäytysnopeus erilaisilla reiänhalkaisijoilla ja –jaoilla sekä tutkittiin väriaineen avulla sokeiden tukikannasten vaikutusta syrjäytyspesun homogeenisuuteen levyn pinnassa. Syrjäytysnopeuden todettiin heikentyvän vapaan reikäpinta-alan pienentyessä. Väriaineellisissa kokeissa ei havaittu tukikannasten merkittävästi alentavan syrjäytysnopeutta. Korroosiokokeilla tutkittiin ja vertailtiin laser- ja vastuspistehitsien korroosionkestokykyä kloridipitoisissa olosuhteissa lämpötilan säätelyn mahdollistavan olosuhdekaapin avulla. Laserhitsauksessa parametrien ei havaittu vaikuttavan merkittävästi hitsin herkistymislämpötilaan. Vastuspistehitsaamalla on mahdollista saavuttaa laserhitsien korroosionkesto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Membrane bioreactors (MBRs) are a combination of activated sludge bioreactors and membrane filtration, enabling high quality effluent with a small footprint. However, they can be beset by fouling, which causes an increase in transmembrane pressure (TMP). Modelling and simulation of changes in TMP could be useful to describe fouling through the identification of the most relevant operating conditions. Using experimental data from a MBR pilot plant operated for 462days, two different models were developed: a deterministic model using activated sludge model n°2d (ASM2d) for the biological component and a resistance in-series model for the filtration component as well as a data-driven model based on multivariable regressions. Once validated, these models were used to describe membrane fouling (as changes in TMP over time) under different operating conditions. The deterministic model performed better at higher temperatures (>20°C), constant operating conditions (DO set-point, membrane air-flow, pH and ORP), and high mixed liquor suspended solids (>6.9gL-1) and flux changes. At low pH (<7) or periods with higher pH changes, the data-driven model was more accurate. Changes in the DO set-point of the aerobic reactor that affected the TMP were also better described by the data-driven model. By combining the use of both models, a better description of fouling can be achieved under different operating conditions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this thesis was to investigate the compression of filter cakes at high filtration pressures with five different test materials and to compare the energy consumption of high pressure compression with the energy consumption of thermal drying. The secondary target of this study was to investigate the particle deformation of test materials during filtration and compression. Literature part consists of basic theory of filtration and compression and of the basic parameters that influence the filtration process. There is also a brief description about all of the test materials including their properties and their industrial production and processing. Theoretical equations for calculating the energy consumptions of the filtrations at different conditions are also presented. At the beginning of the experiments at experimental part, the basic filtration tests were done with all the five test materials. Filtration tests were made at eight different pressures, from 6 bars up to 100 bars, by using piston press pressure filter. Filtration tests were then repeated by using a cylinder with smaller slurry volume than in the first series of filtration tests. Separate filtration tests were also done for investigating the deformation of solid particles during filtration and for finding the optimal curve for raising the filtration pressure. Energy consumption differences between high pressure filtration and ideal thermal drying process were done partly experimentally and partly by using theoretical calculation equations. By comparing these two water removal methods, the optimal ranges for their use were found considering their energy efficiency. The results of the measurements shows that the filtration rate increased and the moisture content of the filter cakes decreased as the filtration pressure was increased. Also the porosity of the filter cakes mainly decreased when the filtration pressure was increased. Particle deformation during the filtration was observed only with coal particles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrasuodatus on tehokas entsyymiliuosten konsentrointi- ja puhdistusmenetelmä. Prosessin ongelmana on kuitenkin kalvojen likaantumisesta johtuva suodatuksen aikainen vuon pienentyminen ja kalvojen hankala puhdistaminen. Oikeilla kalvovalinnoilla ja optimaalisilla pesustrategioilla voidaan suodatus- ja pesuaikoja lyhentää ja nain parantaa suodatusprosessin tehokkuutta ja tuotteen laatua. Työn kirjallisessa osassa on käsitelty entsyymiliuosten ja polymeerikalvojen suodatusprosessiin vaikuttavia ominaisuuksia. Työssä on esitelty myös pesuaineiden ja pesukemikaalien ominaisuuksia sekä pesuprosessiin vaikuttavia tekijöitä. Työn kokeellinen osa koostui kahdesta osasta. Työn ensimmäisessä osassa etsittiin entsyymiliuosten ultrasuodatusprosessiin sopivaa kalvoa vertailemalla kalvojen permeabiliteetteja, hydrofiilisyytta, varausta ja peseytyvyyttä. Suodatuksissa käytettiin kahta Roal Oy:n tuottamaa entsyymiliuosta ja suodatukset tehtiin DSS Labstak M20-laitteistolla. Työn toisen osan tarkoituksena oli etsiä entsyymiliuosten suodatuksessa käytettävien kalvojen likaantumisen syyt sekä tehokas puhdistusaine kalvojen pesuun. Tehokasta pesuainetta etsittiin liotuskokeilla ja laboratoriomittakaavan poikkivirtauslaitteistolla. Analysointeja tehtiin muun muassa FTIR- spektroskoopilla, vuomittauksilla, pyyhkäisyelektronimikroskoopilla ja kontaktikulmamittauksilla. Entsyymiliuosten suodatuksiin sopivan kalvon etsinnässä testattujen kalvojen välillä oli suuria eroja niin permeabiliteeteissa kuin likaantumisessa ja puhdistumisessa, mutta mikään kalvoista ei erottunut ylivoimaisesti parhaaksi. Pesuaineista kaupalliset membraanien puhdistukseen tarkoitetut emäksiset pesuaineet osoittautuivat tehokkaimmiksi lian poistajiksi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Valtimotautiriskin arviointi verenpainepotilailla Valtimotaudit ovat yleisin kuolinsyy koko maailmassa. Väestön elintapojen muuttuminen ja ikääntyminen uhkaavat edelleen lisätä valtimotautien esiintyvyyttä. Kokemäenjokilaakson valtimotautien ehkäisyprojektin tavoitteena oli löytää 45–70-vuotiaasta väestöstä henkilöt, joilla on kohonnut riski sairastua valtimotauteihin. Kaksivaiheisen seulontamenetelmän avulla voitiin terveydenhoitajan antama elintapaneuvonta kohdistaa riskihenkilöihin ja rajoittaa lääkärin vastaanoton tarve niihin potilaisiin, jotka todennäköisesti hyötyvät ennaltaehkäisevästä lääkityksestä. Suomalainen tyypin 2 diabeteksen sairastumisriskin arviointikaavake ja hoitajan toteama kohonnut verenpaine osoittautuivat käytännöllisiksi menetelmiksi seuloa väestöstä riskihenkilöitä. Valtimotautien ehkäisyprojektissa Harjavallassa ja Kokemäellä todettiin verenpainetauti 1 106 henkilöllä, jotka eivät sairastaneet valtimotautia tai aiemmin todettua diabetesta. Heidän tutkimustulostensa avulla voidaan arvioida kohonneen verenpaineen vaikutusta sokeriaineenvaihduntaan ja verenpaineen aiheuttamiin kohde-elinvaurioihin. Sokeriaineenvaihdunnan häiriöt ovat verenpainetautia sairastavilla yleisempiä kuin väestössä muutoin. Käyttämällä metabolisen oireyhtymän kriteerejä sokerirasituskokeen suorittamisen edellytyksenä voidaan tutkimusten määrää vähentää kolmanneksella ja silti löytää lähes kaikki diabetesta tai sen esiastetta sairastavat verenpainepotilaat. Verenpainepotilaista etenkin metabolista oireyhtymää sairastavilla naisilla on suurentunut munuaisten vajaatoiminnan riski. Jos verenpainepotilaan munuaisten toimintaa arvioidaan pelkästään plasman kreatiniini -arvon perusteella, kolme neljästä munuaisten vajaatoimintaa potevasta jää toteamatta verrattuna laskennallisen glomerulusten suodattumisnopeuden määritykseen seulontamenetelmänä. Joka kolmannella verenpainetautia sairastavalla voidaan todeta alaraajavaltimoiden kovettumista; useammin niillä, joiden ylä- ja alaverenpaineen erotus, pulssipaine on yli 65 mmHg. Verenpainetauti on itsenäinen perifeerisen valtimotaudin vaaratekijä. Tutkimuksessa käytetty menetelmä nilkka-olkavarsipainesuhteen määrittämiseksi soveltunee hyvin perusterveydenhuollon käyttöön riskihenkilöiden löytämiseksi. Valtimotautien kokonaisriskin arviointimenetelmät tai uuden riskitekijän, herkän C-reaktiivisen proteiinin määritys eivät voi korvata kohde-elinvaurioiden mittaamista verenpainepotilaan valtimotautiriskin huolellisessa arvioinnissa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to present the new applications of membrane technology in fat and oil processing, with emphasis on development and applications of the enzymatic membrane reactor and its association with extraction and purification technology by supercritical fluids (SCF). Combining the extraction by SCFs and the separation by membranes allows the integration of extractions reactions with selective separation by membranes through filtration of the supercritical mixture (SCF + extracted solutes). This association provides important energy savings regarding the SCF recompression costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin keraamisten mikrosuodatuskalvojen soveltuvuutta kiintoaineen erottamiseen happamasta PLS-liuoksesta eri huokoskoon omaavilla mikrosuodatuskalvoilla. Koelaitteistolla suodatettiin puhdasta vettä, kaoliinipitoista vesiliuosta sekä hapanta kuparia, kalsiumia ja kaoliinia sisältävää malliliuosta. Koeajojen tavoitteena oli saada tietoa permeaattivuon maksimimäärästä eri mikrosuodatuskalvoilla sekä tuotteen puhtaudesta. Näiden lisäksi saatiin tietoa kalvojen likaantumisesta ajon aikana. Teoriaosassa käsiteltiin yleisesti kalvosuodatusta, esitettiin yleiset kalvotekniset menetelmät ja sovellukset sekä käytiin läpi tutkimuksia samankaltaisiin kalvoihin ja sovelluksiin liittyen. Lisäksi teoriaosuudessa pohdittiin mahdollisuutta käyttää myös muita, kuin putkimoduulisia mikrosuodatuskalvoja. Myös työhön oleellisena taustana kuuluvaa hydrometallurgiaa tarkasteltiin teoreettiselta kannalta. Puhtaan veden suodatuskoetuloksista havaittiin, että kaikki kalvot jäivät selvästi valmistajan ilmoittamista arvoista. 1,0 µm CoMetas CoMem® kalvon teoreettinen vesivuo on 10 m3/(h bar) ja 3,0 µm CoMetas CoMem® teoreettinen vesivuo on yli 50 m3/(h bar). Näistä parhaimman vuon arvon sai 1,0 µm CoMetas CoMem® mikrosuodatuskalvo. Tämä kalvo oli paras sekä veden suodatuksissa että malliliuoksella tehdyillä suodatuksilla. Malliliuoksella saavutettiin n. 2000 L/(m2 h) paineen ollessa 2,0 bar ja virtausnopeuden ollessa 4,4 m/s. Vastaavat vesiajon tulokset olivat n. 1100 L/(m2 h) paineen ollessa 1,0 bar ja virtausnopeuden 2,9 m/s. Kaikki kolme käytettyä kalvoa pidättivät kaoliiniliuoksen 81–100 %:sesti. Kuparipitoista malliliuosta suodatettaessa pystyttiin vastaavasti erottamaan 77–99 % kiintoaineesta. Koeajoissa kuitenkin havaittiin huomattava vuon arvojen putoaminen, joka johtui kalvon likaantumisesta. Huomioitavaa oli kuitenkin, että hapanta malliliuosta suodatettaessa permeaattivuon arvot olivat kaoliiniliuoksen suodatuksessa saatuja vastaavia arvoja korkeammat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, one important objective of cardiovascular research has been to find new markers that would improve the risk stratification and diagnosis of patients presenting with symptoms of acute coronary syndrome (ACS). Pregnancy-associated plasma protein A (PAPP-A) is a large metalloproteinase involved in insulin-like growth factor signalling. It is expressed in various tissues and seems to be involved in many physiological and pathological processes, such as folliculogenesis, bone formation, wound healing, pregnancy and atherosclerosis. The aim of this thesis was to investigate PAPP-A in ACS patients. Circulating concentrations of PAPP-A had been previously shown to be elevated in ACS. In this study it was revealed that the form of PAPP-A causing this elevation was the free noncomplexed PAPP-A. Thus, the form of PAPP-A in the circulation of ACS patients differed from the complexed PAPP-A form abundantly present in the circulation during pregnancy. A point-of-care method based on time-resolved immunofluorometric assays was developed, which enabled the rapid detection of free PAPP-A. The method was found to perform well with serum and heparin plasma samples as well as with heparinized whole blood samples. With this method the concentrations of free PAPP-A in healthy individuals were shown to be negligible. When the clinical performance of the method was evaluated with serum samples from ACS patients, it was shown that the free PAPP-A concentration in the admission sample was an independent predictor of myocardial infarction and death. Moreover, as a prognostic marker, free PAPP-A was revealed to be superior to total PAPPA, i.e. the combination of free and complexed PAPP-A, which has been measured by the other groups in this field. As heparin products are widely used as medication in ACS patients, the effect of heparin products on free PAPP-A molecule and circulating concentrations were also investigated in this study. It was shown that intravenous administration of low molecular weight or unfractionated heparin elicits a rapid release of free PAPP-A into the circulation in haemodialysis patients and patients undergoing angiography. Moreover, the interaction between PAPP-A and heparin was confirmed in gel filtration studies. Importantly, the patients included in the clinical evaluation of the free PAPP-A detection method developed had not received any heparin product medication before the admission sample and thus the results were not affected by the heparin effect. In conclusion, free PAPP-A was identified as a novel marker associated with ACS. The point-of-care methods developed enable rapid detection of this molecule which predicts adverse outcome when measured in the admission sample of ACS patients. However, the effect revealed of heparin products on circulating PAPP-A concentrations should be acknowledged when further studies are conducted related to free or total PAPP-A in ACS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.