992 resultados para patient error


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a simple method to automate the geometric optimization of molecular orbital calculations of supermolecules on potential surfaces that are corrected for basis set superposition error using the counterpoise (CP) method. This method is applied to the H-bonding complexes HF/HCN, HF/H2O, and HCCH/H2O using the 6-31G(d,p) and D95 + + (d,p) basis sets at both the Hartree-Fock and second-order Møller-Plesset levels. We report the interaction energies, geometries, and vibrational frequencies of these complexes on the CP-optimized surfaces; and compare them with similar values calculated using traditional methods, including the (more traditional) single point CP correction. Upon optimization on the CP-corrected surface, the interaction energies become more negative (before vibrational corrections) and the H-bonding stretching vibrations decrease in all cases. The extent of the effects vary from extremely small to quite large depending on the complex and the calculational method. The relative magnitudes of the vibrational corrections cannot be predicted from the H-bond stretching frequencies alone

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the surprising result that ab initio calculations on benzene and other planar arenes at correlated MP2, MP3, configuration interaction with singles and doubles (CISD), and coupled cluster with singles and doubles levels of theory using standard Pople’s basis sets yield nonplanar minima has been reported. The planar optimized structures turn out to be transition states presenting one or more large imaginary frequencies, whereas single-determinant-based methods lead to the expected planar minima and no imaginary frequencies. It has been suggested that such anomalous behavior can be originated by two-electron basis set incompleteness error. In this work, we show that the reported pitfalls can be interpreted in terms of intramolecular basis set superposition error (BSSE) effects, mostly between the C–H moieties constituting the arenes. We have carried out counterpoise-corrected optimizations and frequency calculations at the Hartree–Fock, B3LYP, MP2, and CISD levels of theory with several basis sets for a number of arenes. In all cases, correcting for intramolecular BSSE fixes the anomalous behavior of the correlated methods, whereas no significant differences are observed in the single-determinant case. Consequently, all systems studied are planar at all levels of theory. The effect of different intramolecular fragment definitions and the particular case of charged species, namely, cyclopentadienyl and indenyl anions, respectively, are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To set local dose reference levels (DRL) that allow radiologists to control stochastic and deterministic effects. Methods and materials: Dose indicators for cerebral angiographies and hepatic embolizations were collected during 4 months and analyzed in our hospital. The data were compared when an image amplifier was used instead of a flat panel detector. The Mann and Whitney test was used. Results: For the 40 cerebral angiographies performed the DRL for DAP, fluoroscopy time and number of images were respectively: 166 Gy.cm2, 19 min, 600. The maximum DAP was 490 Gy.cm2 (fluoroscopy time: 84 min). No significant difference for fluoroscopy time and DAP for image amplifier and flat panel detector (p = 0.88) was observed. The number of images was larger for flat panel detector (p = 0.004). The values obtained were slightly over the present proposed DRL: 150 Gy.cm2, 15 min, 400. Concerning the 13 hepatic embolizations the DRL for DAP fluoroscopy time and number of images were: 315 Gy.cm2, 25 min, 370. The maximum DAP delivered was 845 Gy.cm2 (fluoroscopy time of 48 min). No significant difference between image amplifier and flat panel detector was observed (p = 0.005). The values obtained were also slightly over the present proposed DRL: 300 Gy.cm2, 20 min, 200. Conclusion: These results show that the introduction of flat panel detector did not lead to an increase in patient dose. A DRL concerning the cumulative dose (that allow to control the deterministic effect) should be introduced to allow radiologists to have full control on the risks associated with ionizing radiations. Results of this on going study will be presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify which physician and patient characteristics are associated with physicians' estimation of their patient social status.DESIGN: Cross-sectional ulticentric survey. SETTING: Fourty-seven primary care private offices in Western Switzerland. PARTICIPANTS: Random sample of 2030 patients ≥ 16, who encountered a general practitioner (GP) between September 2010 and February 2011. MAIN MEASURES: PRIMARY OUTCOME: patient social status perceived by GPs, using the MacArthur Scale of Subjective Social Status, ranging from the bottom (0) to the top (10) of the social scale.Secondary outcome: Difference between GP's evaluation and patient's own evaluation of their social status. Potential patient correlates: material and social deprivation using the DiPCare-Q, health status using the EQ-5D, sources of income, and level of education. GP characteristics: opinion regarding patients' deprivation and its influence on health and care. RESULTS: To evaluate patient social status, GPs considered the material, social, and health aspects of deprivation, along with education level, and amount and type of income. GPs declaring a frequent reflexive consideration of their own prejudice towards deprived patients, gave a higher estimation of patients' social status (+1.0, p = 0.002). Choosing a less costly treatment for deprived patients was associated with a lower estimation (-0.7, p = 0.002). GP's evaluation of patient social status was 0.5 point higher than the patient's own estimate (p<0.0001). CONCLUSIONS: GPs can perceive the various dimensions of patient social status, although heterogeneously, according partly to their own characteristics. Compared to patients' own evaluation, GPs overestimate patient social status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of terminally ill patients are admitted into the intensive care unit, and decisions of limitation, or of palliative care are made to avoid medical futility. The principle of autonomy states that the patient (or in case of necessity his relatives) should make end of life decision after detailed information. The exercise of autonomy is difficult due to the disease of the patient and the nature of invasive treatments, but also due to organisational and communication barriers. The latter can be surmounted by a proactive approach. Early communication with the patient and relatives about the sometimes-limited expectations of an invasive treatment plan, and the possibility of palliative care allow to integer patient's preferences in the formulation of a therapeutical plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Injectable drugs are high-risk products and their reconstitution in hospital wards is a potential source of errors. Thus, in order to secure the reconstitution process and thereby improve safety, the pharmacy department of Lausanne University Hospital is focusing on developing ready-to-use forms (CIVAS). These preparations are compounded in controlled clean rooms and are analyzed prior to release. In the intensive care unit, amiodarone 12.5 mg/mL in glucose 5% is one of the high-risk preparations, which has led the pharmacy to develop a ready-to-use solution. To this end, a one-year stability study was initiated, and the preliminary results (after six months) are illustrated here. A stability-indicating HPLC method was developed and validated for monitoring the concentration of amiodarone. Batches were stored at 5 °C and 30 °C, which were analyzed immediately after preparation, after one, two, four and six months of storage. The pH and osmolality values were monitored at the respective time intervals. It was observed that after six months, all the results were within specifications. However, the pH values started to decrease after two months when amiodarone was stored at 30 °C. After six months, a degradation peak appeared on the chromatogram of these solutions, which suggested that amiodarone is more stable at 5 °C. The preliminary results obtained in this study indicated that injectable amiodarone solutions are stable for six months under refrigerated storage conditions. The study is ongoing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a patient with Marfan's syndrome and pectus excavatum who underwent open heart surgery with simultaneous correction of the sternal malformation. Permanent internal stabilization, achieved by bilateral overlapping of the bevelled ends of the lowest ribs and reinforced with sternal closure wires offered a maintained postoperative chest wall stability, avoided the potential postoperative complications of cardiac compression, and improved the aesthetic appearance of the anterior chest wall. The increased risk of bleeding due to extensive dissection was minimized by postponing the repair of pectus excavatum to when protamin is administered after termination of cardiopulmonary bypass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a woman with syncope and persistently prolonged QTc interval. Screening of congenital long QT syndrome (LQTS) genes revealed that she was a heterozygous carrier of a novel KCNH2 mutation, c.G238C. Electrophysiological and biochemical characterizations unveiled the pathogenicity of this new mutation, displaying a 2-fold reduction in protein expression and current density due to a maturation/trafficking-deficient mechanism. The patient's phenotype can be fully explained by this observation. This study illustrates the importance of performing genetic analyses and mutation characterization when there is a suspicion of congenital LQTS. Identifying mutations in the PAS domain or other domains of the hERG1 channel and understanding their effect may provide more focused and mutation-specific risk assessment in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D + t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D + t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall.