943 resultados para microwave medical imaging
Resumo:
Summary Generalized Procrustes analysis and thin plate splines were employed to create an average 3D shape template of the proximal femur that was warped to the size and shape of a single 2D radiographic image of a subject. Mean absolute depth errors are comparable with previous approaches utilising multiple 2D input projections. Introduction Several approaches have been adopted to derive volumetric density (g cm-3) from a conventional 2D representation of areal bone mineral density (BMD, g cm-2). Such approaches have generally aimed at deriving an average depth across the areal projection rather than creating a formal 3D shape of the bone. Methods Generalized Procrustes analysis and thin plate splines were employed to create an average 3D shape template of the proximal femur that was subsequently warped to suit the size and shape of a single 2D radiographic image of a subject. CT scans of excised human femora, 18 and 24 scanned at pixel resolutions of 1.08 mm and 0.674 mm, respectively, were equally split into training (created 3D shape template) and test cohorts. Results The mean absolute depth errors of 3.4 mm and 1.73 mm, respectively, for the two CT pixel sizes are comparable with previous approaches based upon multiple 2D input projections. Conclusions This technique has the potential to derive volumetric density from BMD and to facilitate 3D finite element analysis for prediction of the mechanical integrity of the proximal femur. It may further be applied to other anatomical bone sites such as the distal radius and lumbar spine.
Resumo:
Nationalism is not a naturally occurring sentiment, but rather needs to be carefully nurtured and sustained in the social imaginary through the production and circulation of unifying narratives that invoke the nation’s imagined community. The school curriculum is crucial in this process, legitimating and disseminating selected narratives while de-legitimating and marginalising other accounts and their voices. Certain watershed events in nations’ histories have always posed political problems in history curricula (Cajani & Ross, 2007) –however the pressures and concerns of current times now suggest political solutions in history curricula. This paper briefly examines recent political debates in Australia to argue that the school history curriculum has become a site of increasing interest for the exercise of official forms of nationalism and the production of a nostalgic, celebratory national biography. The public debates around school history curriculum are theorised as nostalgic re-nationalising efforts in response to the march of cultural globalisation and its attendant uncertainties.
Resumo:
The validation of Computed Tomography (CT) based 3D models takes an integral part in studies involving 3D models of bones. This is of particular importance when such models are used for Finite Element studies. The validation of 3D models typically involves the generation of a reference model representing the bones outer surface. Several different devices have been utilised for digitising a bone’s outer surface such as mechanical 3D digitising arms, mechanical 3D contact scanners, electro-magnetic tracking devices and 3D laser scanners. However, none of these devices is capable of digitising a bone’s internal surfaces, such as the medullary canal of a long bone. Therefore, this study investigated the use of a 3D contact scanner, in conjunction with a microCT scanner, for generating a reference standard for validating the internal and external surfaces of a CT based 3D model of an ovine femur. One fresh ovine limb was scanned using a clinical CT scanner (Phillips, Brilliance 64) with a pixel size of 0.4 mm2 and slice spacing of 0.5 mm. Then the limb was dissected to obtain the soft tissue free bone while care was taken to protect the bone’s surface. A desktop mechanical 3D contact scanner (Roland DG Corporation, MDX 20, Japan) was used to digitise the surface of the denuded bone. The scanner was used with the resolution of 0.3 × 0.3 × 0.025 mm. The digitised surfaces were reconstructed into a 3D model using reverse engineering techniques in Rapidform (Inus Technology, Korea). After digitisation, the distal and proximal parts of the bone were removed such that the shaft could be scanned with a microCT (µCT40, Scanco Medical, Switzerland) scanner. The shaft, with the bone marrow removed, was immersed in water and scanned with a voxel size of 0.03 mm3. The bone contours were extracted from the image data utilising the Canny edge filter in Matlab (The Mathswork).. The extracted bone contours were reconstructed into 3D models using Amira 5.1 (Visage Imaging, Germany). The 3D models of the bone’s outer surface reconstructed from CT and microCT data were compared against the 3D model generated using the contact scanner. The 3D model of the inner canal reconstructed from the microCT data was compared against the 3D models reconstructed from the clinical CT scanner data. The disparity between the surface geometries of two models was calculated in Rapidform and recorded as average distance with standard deviation. The comparison of the 3D model of the whole bone generated from the clinical CT data with the reference model generated a mean error of 0.19±0.16 mm while the shaft was more accurate(0.08±0.06 mm) than the proximal (0.26±0.18 mm) and distal (0.22±0.16 mm) parts. The comparison between the outer 3D model generated from the microCT data and the contact scanner model generated a mean error of 0.10±0.03 mm indicating that the microCT generated models are sufficiently accurate for validation of 3D models generated from other methods. The comparison of the inner models generated from microCT data with that of clinical CT data generated an error of 0.09±0.07 mm Utilising a mechanical contact scanner in conjunction with a microCT scanner enabled to validate the outer surface of a CT based 3D model of an ovine femur as well as the surface of the model’s medullary canal.
Resumo:
There is currently a strong focus worldwide on the potential of large-scale Electronic Health Record (EHR) systems to cut costs and improve patient outcomes through increased efficiency. This is accomplished by aggregating medical data from isolated Electronic Medical Record databases maintained by different healthcare providers. Concerns about the privacy and reliability of Electronic Health Records are crucial to healthcare service consumers. Traditional security mechanisms are designed to satisfy confidentiality, integrity, and availability requirements, but they fail to provide a measurement tool for data reliability from a data entry perspective. In this paper, we introduce a Medical Data Reliability Assessment (MDRA) service model to assess the reliability of medical data by evaluating the trustworthiness of its sources, usually the healthcare provider which created the data and the medical practitioner who diagnosed the patient and authorised entry of this data into the patient’s medical record. The result is then expressed by manipulating health record metadata to alert medical practitioners relying on the information to possible reliability problems.
Resumo:
Electronic Health Record (EHR) systems are being introduced to overcome the limitations associated with paper-based and isolated Electronic Medical Record (EMR) systems. This is accomplished by aggregating medical data and consolidating them in one digital repository. Though an EHR system provides obvious functional benefits, there is a growing concern about the privacy and reliability (trustworthiness) of Electronic Health Records. Security requirements such as confidentiality, integrity, and availability can be satisfied by traditional hard security mechanisms. However, measuring data trustworthiness from the perspective of data entry is an issue that cannot be solved with traditional mechanisms, especially since degrees of trust change over time. In this paper, we introduce a Time-variant Medical Data Trustworthiness (TMDT) assessment model to evaluate the trustworthiness of medical data by evaluating the trustworthiness of its sources, namely the healthcare organisation where the data was created and the medical practitioner who diagnosed the patient and authorised entry of this data into the patient’s medical record, with respect to a certain period of time. The result can then be used by the EHR system to manipulate health record metadata to alert medical practitioners relying on the information to possible reliability problems.
Resumo:
This study aimed to identify: i) the prevalence of malnutrition according to the scored Patient Generated-Subjective Global Assessment (PG-SGA); ii) utilization of available nutrition resources; iii) patient nutrition information needs; and iv) external sources of nutrition information. An observational, cross-sectional study was undertaken at an Australian public hospital on 191 patients receiving oncology services. According to PG-SGA, 49% of patients were malnourished and 46% required improved symptom management and/or nutrition intervention. Commonly reported nutrition-impact symptoms included: peculiar tastes (31%), no appetite (24%) and nausea (24%). External sources of nutrition information were accessed by 37%, with popular choices being media/internet (n=19) and family/friends (n=13). In a sub-sample (n=65), 32 patients were aware of the available nutrition resources, 23 thought the information sufficient and 19 patients had actually read them. Additional information on supplements and modifying side effects was requested by 26 patients. Malnutrition is common in oncology patients receiving treatment at an Australian public hospital and almost half require improved symptom management and/or nutrition intervention. Patients who read the available nutrition information found it useful, however awareness of these nutrition resources and the provision of information on supplementation and managing symptoms requires attention.
Resumo:
Objective: The emergency medical system (EMS) can be defined as a comprehensive, coordinated and integrated system of care for patients suffering acute illness and injury. The aim of the present paper is to describe the evolution of the Queensland Emergency Medical System (QEMS) and to recommend a strategic national approach to EMS development. Methods: Following the formation of the Queensland Ambulance Service in 1991, a state EMS committee was formed. This committee led the development and approval of the cross portfolio QEMS policy framework that has resulted in dynamic policy development, system monitoring and evaluation. This framework is led by the Queensland Emergency Medical Services Advisory Committee. Results: There has been considerable progress in the development of all aspects of the EMS in Queensland. These developments have derived from the improved coordination and leadership that QEMS provides and has resulted in widespread satisfaction by both patients and stakeholders. Conclusions: The strategic approach outlined in the present paper offers a model for EMS arrangements throughout Australia. We propose that the Council of Australian Governments should require each state and Territory to maintain an EMS committee. These state EMS committees should have a broad portfolio of responsibilities. They should provide leadership and direction to the development of the EMS and ensure coordination and quality of outcomes. A national EMS committee with broad representation and broad scope should be established to coordinate the national development of Australia's EMS.
Resumo:
Raman spectroscopy and FT-IR imaging analyses of cave wall pigment samples from north Queensland (Australia) indicate that some hand stencils were undertaken during a dry environmental phase indicating late Holocene age. Other, earlier painting episodes also took place during dry environmental periods of the terminal Pleistocene and/or early Holocene. These results represent a rare opportunity to attain chronological information for rock art in conditions where insufficient carbon is present for radiocarbon dating.
Resumo:
Purpose To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. Setting Eye Clinic, Queensland University of Technology, Brisbane, Australia. Methods This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through a dilated pupil. Lenses were graded with the Lens Opacities Classification System III. Intraobserver and interobserver reliability of 3 observers performing 3 repeated Scheimpflug lens densitometry measurements each was assessed. Three lens densitometry metrics were evaluated: linear, for which a line was drawn through the visual axis and a mean lens densitometry value given; peak, which is the point at which lens densitometry is greatest on the densitogram; 3-dimensional (3D), in which a fixed, circular 3.0 mm area of the lens is selected and a mean lens densitometry value given. Bland and Altman analysis of repeatability for multiple measures was applied; results were reported as the repeatability coefficient and relative repeatability (RR). Results Twenty eyes were evaluated. Repeatability was high. Overall, interobserver repeatability was marginally lower than intraobserver repeatability. The peak was the least reliable metric (RR 37.31%) and 3D, the most reliable (RR 5.88%). Intraobserver and interobserver lens densitometry values in the cataract group were slightly less repeatable than in the noncataract group. Conclusion The intraobserver and interobserver repeatability of Scheimpflug lens densitometry was high in eyes with cataract and eyes without cataract, which supports the use of automated lens density scoring using the Scheimpflug system evaluated in the study
Resumo:
Objective: To systematically review the published evidence of the impact of health information technology (HIT) on the quality of medical and health care specifically clinicians’ adherence to evidence-based guidelines and the corresponding impact this had on patient clinical outcomes. In order to be as inclusive as possible the research examined literature discussing the use of health information technologies and systems in both medical care such as clinical and surgical, and other health care such as allied health and preventive services.----- Design: Systematic review----- Data Sources: Relevant literature was systematically searched on English language studies indexed in MEDLINE and CINAHL(1998 to 2008), Cochrane Library, PubMed, Database of Abstracts of Review of Effectiveness (DARE), Google scholar and other relevant electronic databases. A search for eligible studies (matching the inclusion criteria) was also performed by searching relevant conference proceedings available through internet and electronic databases, as well as using reference lists identified from cited papers.----- Selection criteria: Studies were included in the review if they examined the impact of Electronic Health Record (EHR), Computerised Provider Order-Entry (CPOE), or Decision Support System (DS); and if the primary outcomes of the studies were focused on the level of compliance with evidence-based guidelines among clinicians. Measures could be either changes in clinical processes resulting from a change of the providers’ behaviour or specific patient outcomes that demonstrated the effectiveness of a particular treatment given by providers. ----- Methods: Studies were reviewed and summarised in tabular and text form. Due to heterogeneity between studies, meta-analysis was not performed.----- Results: Out of 17 studies that assessed the impact of health information technology on health care practitioners’ performance, 14 studies revealed a positive improvement in relation to their compliance with evidence-based guidelines. The primary domain of improvement was evident from preventive care and drug ordering studies. Results from the studies that included an assessment for patient outcomes however, were insufficient to detect either clinically or statistically important improvements as only a small proportion of these studies found benefits. For instance, only 3 studies had shown positive improvement, while 5 studies revealed either no change or adverse outcomes.----- Conclusion: Although the number of included studies was relatively small for reaching a conclusive statement about the effectiveness of health information technologies and systems on clinical care, the results demonstrated consistency with other systematic reviews previously undertaken. Widescale use of HIT has been shown to increase clinician’s adherence to guidelines in this review. Therefore, it presents ongoing opportunities to maximise the uptake of research evidence into practice for health care organisations, policy makers and stakeholders.
Resumo:
Over the last few years various research groups around the world have employed X-ray Computed Tomography (CT) imaging in the study of mummies – Toronto-Boston (1,2), Manchester(3). Prior to the development of CT scanners, plane X-rays were used in the investigation of mummies. Xeroradiography has also been employed(4). In a xeroradiograph, objects of similar X-ray density (very difficult to see on a conventional X-ray) appear edge-enhanced and so are seen much more clearly. CT scanners became available in the early 1970s. A CT scanner produces cross-sectional X-rays of objects. On a conventional X-radiograph individual structures are often very difficult to see because all the structures lying in the path of the X-ray beam are superimposed, a problem that does not occur with CT. Another advantage of CT is that the information in a series of consecutive images may be combined to produce a three-dimensional reconstruction of an object. Slices of different thickness and magnification may be chosen. Why CT a mummy? Prior to the availability of CT scanners, the only way of finding out about the inside of a mummy in any detail was to unwrap and dissect it. This has been done by various research groups – most notably the Manchester, UK and Pennsylvania University, USA mummy projects(5,6). Unwrapping a mummy and carrying out an autopsy is obviously very destructive. CT studies hold the possibility of producing a lot more information than is possible from plain X-rays and are able to show the undisturbed arrangement of the wrapped body. CT is also able to provide information about the internal structure of bones, organ packs, etc that wouldn’t be possible without sawing through the bones etc. The mummy we have scanned is encased in a coffin which would have to have been broken open in order to remove the body.
Resumo:
A crucial process of chlamydial development involves differentiation of the replicative reticulate body (RB) into the infectious elementary body (EB). We present experimental evidence to provide support for a contact-dependent hypothesis for explaining the trigger involved in differentiation. We recorded live-imaging of Chlamydia trachomatis-infected McCoy cells at key times during development and tracked the temporospatial trajectories of individual chlamydial particles. We found that movement of the particles is related to development. Early to mid-developmental stages involved slight wobbling of RBs. The average speed of particles increased sharply at 24 h postinfection (after the estimated onset of RB to EB differentiation). We also investigated a penicillin-supplemented culture containing EBs, RBs, and aberrantly enlarged, stressed chlamydiae. Near-immobile enlarged particles are consistent with their continued tethering to the chlamydial inclusion membrane (CIM). We found a significantly negative, nonlinear association between speed and size/type of particles, providing further support for the hypothesis that particles become untethered near the onset of RB to EB differentiation. This study establishes the relationship between the motion properties of the chlamydiae and developmental stages, whereby wobbling RBs gradually lose contact with the CIM, and RB detachment from the CIM is coincidental with the onset of late differentiation.
Corneal topography with Scheimpflug imaging and videokeratography : comparative study of normal eyes
Resumo:
PURPOSE: To compare the repeatability within anterior corneal topography measurements and agreement between measurements with the Pentacam HR rotating Scheimpflug camera and with a previously validated Placido disk–based videokeratoscope (Medmont E300). ------ SETTING: Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Queensland, Australia. ----- METHODS: Normal eyes in 101 young adult subjects had corneal topography measured using the Scheimpflug camera (6 repeated measurements) and videokeratoscope (4 repeated measurements). The best-fitting axial power corneal spherocylinder was calculated and converted into power vectors. Corneal higher-order aberrations (HOAs) (up to the 8th Zernike order) were calculated using the corneal elevation data from each instrument. ----- RESULTS: Both instruments showed excellent repeatability for axial power spherocylinder measurements (repeatability coefficients <0.25 diopter; intraclass correlation coefficients >0.9) and good agreement for all power vectors. Agreement between the 2 instruments was closest when the mean of multiple measurements was used in analysis. For corneal HOAs, both instruments showed reasonable repeatability for most aberration terms and good correlation and agreement for many aberrations (eg, spherical aberration, coma, higher-order root mean square). For other aberrations (eg, trefoil and tetrafoil), the 2 instruments showed relatively poor agreement. ----- CONCLUSIONS: For normal corneas, the Scheimpflug system showed excellent repeatability and reasonable agreement with a previously validated videokeratoscope for the anterior corneal axial curvature best-fitting spherocylinder and several corneal HOAs. However, for certain aberrations with higher azimuthal frequencies, the Scheimpflug system had poor agreement with the videokeratoscope; thus, caution should be used when interpreting these corneal aberrations with the Scheimpflug system.