990 resultados para joint motion
Resumo:
Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STARM). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STARM patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STARM from four marker-clusters assigned to areas extracted from spatial distribution. All experiments were realized using a stereophotogrammetric system to track the skin markers and a bi-plane fluoroscopic system to track the knee prosthesis. Computation of the spatial distribution of STA was realized on 19 subjects using 80 markers apposed on the lower limb. Three different areas were extracted from the distribution map of the thigh. The marker displacement reached a maximum of 24.9mm and 15.3mm in the proximal areas of thigh and shank, respectively. STARM was larger on thigh than the shank with RMS error in cluster orientations between 1.2° and 8.1°. The translation RMS errors were also large (3.0mm to 16.2mm). No marker-cluster correctly compensated for STARM. However, the coefficient of multiple correlations exhibited excellent scores between skin and bone kinematics, as well as for STARM between subjects. These correlations highlight dependencies between STARM and the kinematic components. This study provides new insights for modeling STARM for gait activity.
Resumo:
The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.
Resumo:
Many therapies have been proposed for the management of temporomandibular disorders, including the use of different drugs. However, lack of knowledge about the mechanisms behind the pain associated with this pathology, and the fact that the studies carried out so far use highly disparate patient selection criteria, mean that results on the effectiveness of the different medications are inconclusive. This study makes a systematic review of the literature published on the use of tricyclic antidepressants for the treatment of temporomandibular disorders, using the SORT criteria (Strength of recommendation taxonomy) to consider the level of scientific evidence of the different studies. Following analysis of the articles, and in function of their scientific quality, a type B recommendation is given in favor of the use of tricyclic antidepressants for the treatment of temporomandibular disorders.
Resumo:
Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.
Resumo:
PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.
Resumo:
The CO2-laser-MAG hybrid welding process has been shown to be a productive choice for the welding industry, being used in e.g. the shipbuilding, pipe and beam manufacturing, and automotive industries. It provides an opportunity to increase the productivity of welding of joints containing air gaps compared with autogenous laser beam welding, with associated reductions in distortion and marked increases in welding speeds and penetration in comparison with both arc and autogenous laser welding. The literature study indicated that the phenomena of laser hybrid welding are mostly being studied using bead-on-plate welding or zero air gap configurations. This study shows it very clearly that the CO2 laser-MAG hybrid welding process is completely different, when there is a groove with an air gap. As in case of industrial use it is excepted that welding is performed for non-zero grooves, this study is of great importance for industrial applications. The results of this study indicate that by using a 6 kW CO2 laser-MAG hybrid welding process, the welding speed may also be increased if an air gap is present in the joint. Experimental trials indicated that the welding speed may be increased by 30-82% when compared with bead-on-plate welding, or welding of a joint with no air gap i.e. a joint prepared as optimum for autogenous laser welding. This study demonstrates very clearly, that the separation of the different processes, as well as the relative configurations of the processes (arc leading or trailing) affect welding performance significantly. These matters influence the droplet size and therefore the metal transfer mode, which in turn determined the resulting weld quality and the ability to bridge air gaps. Welding in bead-onplate mode, or of an I butt joint containing no air gap joint is facilitated by using a leading torch. This is due to the preheating effect of the arc, which increases the absorptivity of the work piece to the laser beam, enabling greater penetration and the use of higher welding speeds. With an air gap present, air gap bridging is more effectively achieved by using a trailing torch because of the lower arc power needed, the wider arc, and the movement of droplets predominantly towards the joint edges. The experiments showed, that the mode of metal transfer has a marked effect on gap bridgeability. Transfer of a single droplet per arc pulse may not be desirable if an air gap is present, because most of the droplets are directed towards the middle of the joint where no base material is present. In such cases, undercut is observed. Pulsed globular and rotational metal transfer modes enable molten metal to also be transferred to the joint edges, and are therefore superior metal transfer modes when bridging air gaps. It was also found very obvious, that process separation is an important factor in gap bridgeability. If process separation is too large, the resulting weld often exhibits sagging, or no weld may be formed at all as a result of the reduced interaction between the component processes. In contrast, if the processes are too close to one another, the processing region contains excess molten metal that may create difficulties for the keyhole to remain open. When the distance is optimised - i.e. a separation of 0-4 mm in this study, depending on the welding speed and beam-arc configuration - the processes act together, creating beneficial synergistic effects. The optimum process separation when using a trailing torch was found to be shorter (0-2 mm) than when a leading torch is used (2-4 mm); a result of the facilitation of weld pool motion when the latter configuration is adopted. This study demonstrates, that the MAG process used has a strong effect on the CO2-laser-MAG hybrid welding process. The laser beam welding component is relatively stable and easy to manage, with only two principal processing parameters (power and welding speed) needing to be adjusted. In contrast, the MAG process has a large number of processing parameters to optimise, all of which play an important role in the interaction between the laser beam and the arc. The parameters used for traditional MAG welding are often not optimal in achieving the most appropriate mode of metal transfer, and weld quality in laser hybrid welding, and must be optimised if the full range of benefits provided by hybrid welding are to be realised.
Resumo:
Modelling the shoulder's musculature is challenging given its mechanical and geometric complexity. The use of the ideal fibre model to represent a muscle's line of action cannot always faithfully represent the mechanical effect of each muscle, leading to considerable differences between model-estimated and in vivo measured muscle activity. While the musculo-tendon force coordination problem has been extensively analysed in terms of the cost function, only few works have investigated the existence and sensitivity of solutions to fibre topology. The goal of this paper is to present an analysis of the solution set using the concepts of torque-feasible space (TFS) and wrench-feasible space (WFS) from cable-driven robotics. A shoulder model is presented and a simple musculo-tendon force coordination problem is defined. The ideal fibre model for representing muscles is reviewed and the TFS and WFS are defined, leading to the necessary and sufficient conditions for the existence of a solution. The shoulder model's TFS is analysed to explain the lack of anterior deltoid (DLTa) activity. Based on the analysis, a modification of the model's muscle fibre geometry is proposed. The performance with and without the modification is assessed by solving the musculo-tendon force coordination problem for quasi-static abduction in the scapular plane. After the proposed modification, the DLTa reaches 20% of activation.
Resumo:
Being highly discussed the problem of climate change and global warming has been keeping importance for several of decades. As a response to the world’s need in solution for climate change disasters, the United Nations Framework Convention on Climate Change was adopted in 1992 and supplemented with the Kyoto protocol in 1997. This work is aimed to give better understanding of the Convention, Kyoto Protocol with its mechanisms and their function, related to energy projects in such case countries, as Russia and China, in order to assist evaluation of projects cost-effectiveness. It provides basic information about the Convention and the Protocol with their regulations, overview of present situation and future post-Kyoto forecasts, while the most attention is concentrated on the clean development mechanism and joint implementation step-by-step project cycles and specific regulations in given countries. The current study disclosed that CDM and JI project cycles are resulting in a complicated process. By the moment it requires step-by-step following of a number of methodologies, spending time and finance to particular project development. Uncertainties about post-Kyoto period bring additional risk to the projects and complicate any business decision concerning Kyoto Protocol.
Resumo:
The costs related to the treatment of infected total joint arthroplasties represent an ever groving burden to the society. Different patient-adapted therapeutic options like débridement and retention, 1- or 2-step exchange can be used. If a 2-step exchange is used we have to consider short (2-4 weeks) or long (>4-6 weeks) interval treatment. The Swiss DRG (Diagnose related Groups) determines the reimboursement the hopsital receives for the treatment of an infected total arthroplasty. The review assesses the cost-effectiveness of hospitalisation practices linked to surgical treatment in the two-stage exchange of a prosthetic-joint infection. The aim of this retrospectiv study is to compare the economical impact between a short (2 to 4 weeks) versus a long (6 weeks and above) interval during a two-satge procedure to determine the financial impact. Retrospectiv study of the patients with a two-stage procedure for a hip or knee prosthetic joint infection at CHUV hospital Lausanne (Switzerland) between 2012 and 2013. The review analyses the correlation between the interval length and the length of the hospital stay as well as with the costs and revenues per hospital stay. In average there is a loss of 40′000 Euro per hospitalisation for the treatment of prosthetic joint infection. Revenues never cover all the costs, even with a short interval procedure. This economical loss increases with the length of the hospital stay if a long-term intervall is choosen. The review explores potential for improvement in reimbourement practices and hospitalisation practices in the current Swiss healthcare setting. There should be alternative setups to decrease the burden of medical costs by a) increase the reimboursment for the treatment of infected total joints or by b) splitting the hospital stay with partners (rapid transfer after first operation from center hospital to level 2 hospital and retransfer for second operation to center) in order to increase revenues.
Resumo:
Prosthetic joint replacement is one of the most successful surgical procedures of the last century and the number of implanted artificial joints is rapidly growing. While the result of the procedure is generally positive, infections may occur leading to patient suffering, surgeon's frustration and important costs to the health system. Infection after prosthetic joint replacement is thus a feared complication as healing rates can be low, functional result poor and satisfaction of the patient abysmal. However, if a patient-adapted treatment of infected total joints is used, an overall success rate of above 90 % can be obtained. The patient-adapted treatment concept is based on five strong pillars: teamwork, understanding biofilm, proper diagnostics, proper definition and classification and patient-tailored treatment.
Resumo:
Different therapeutic options for prosthetic joint infections exist, but surgery remains the key. With a two-stage exchange procedure, a success rate above 90% can be expected. Currently, there is no consensus regarding the optimal duration between explantation and the reimplantation in a two-stage procedure. The aim of this study was to retrospectively compare treatment outcomes between short-interval and long-interval two-stage exchanges. Patients having a two-stage exchange of a hip or knee prosthetic joint infection at Lausanne University Hospital (Switzerland) between 1999 and 2013 were included. The satisfaction of the patient, the function of the articulation and the eradication of infection, were compared between patients having a short (2 to 4 weeks) versus a long (4 weeks and more) interval during a two-stage procedure. Patient satisfaction was defined as good if the patient did not have pain and bad if the patient had pain. Functional outcome was defined good if the patient had a prosthesis in place and could walk, medium if the prosthesis was in place but the patient could not walk, and bad if the prosthesis was no longer in place. Infection outcome was considered good if there had been no re-infection and bad if there had been a re-infection of the prosthesis 145 patients (100 hips, 45 knees) were identified with a median age of 68 years (range 19-103). The median hospital stay was 58 days (range 10-402). The median follow-up was 12.9 months (range 0.5-152). 28 % and 72 % of the patients had a short-interval and long-interval exchange of the prosthesis, respectively. Patient satisfaction, functional outcome and infection outcome for patients having a short versus a long interval are reported in the Table. The patient satisfaction was higher when a long interval was performed whereas the functional and infection outcomes were higher when a short interval was performed. According to this study a short-interval exchange appears preferable to a long interval, especially in the view of treatment effectiveness and functional outcome.
Resumo:
Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.