931 resultados para device failure analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to contribute to the genetic breeding programs of buffaloes, this study aimed to determine the influence of environmental effects on the stayability (ST) of dairy female Murrah buffalo in the herd. Data from 1016 buffaloes were used. ST was defined as the ability of the female to remain in the herd for 1, 2, 3, 4, 5 or 6 years after the first calving. Environmental effects were studied by survival analysis, adjusted to the fixed effects of farm, year and season of birth, class of first-lactation milk yield and age at first calving. The data were analyzed using the LIFEREG procedure of the SAS program that fits parametric models to failure time data (culling or ST = 0), and estimates parameters by maximum likelihood estimation. Breeding farm, year of birth and first-lactation milk yield significantly influenced (P < 0.0001) the ST to the specific ages (1 to 6 years after the first calving). Buffaloes that were older at first calving presented higher probabilities of being culled 1 year after the first calving, without any effect on culling at older ages. Buffaloes with a higher milk yield at first calving presented a lower culling probability and remained for a longer period of time in the herd. The effects of breeding farm, year of birth and first-lactation milk yield should be included in models used for the analysis of ST in buffaloes. Copyright © The Animal Consortium 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accessing vaginal pH is fundamental during gynaecological visit for the detection of abnormal vaginal flora (AVF), but use of pH strips may be time-consuming and difficult to interpret. The aim of this study was to evaluate the VS-SENSE test (Common Sense Ltd, Caesarea, Israel) as a tool for the diagnosis of AVF and its correlation with abnormal pH and bacterial vaginosis (BV). The study population consisted of 45 women with vaginal pH ≥ 4.5 and 45 women with normal pH. Vaginal samples were evaluated by VS-SENSE test, microscopy and microbiologic cultures. Comparing with pH strips results, VS-SENSE test specificity was 97.8% and sensitivity of 91%. All severe cases of BV and aerobic vaginitis (AV) were detected by the test. Only one case with normal pH had an unclear result. Concluding, VS-SENSE test is easy to perform, and it correlates with increased pH, AVF, and the severe cases of BV and AV. Copyright © 2010 Gilbert G. G. Donders et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new device for irrigation, which presents hydrodynamic activation based on the pressure-suction technology, has recently been introduced to the market: the Rinsendo system. This study compared the efficacy of the Rinsendo system and conventional (manualdynamic) irrigation in the removal of debris from the root canal walls, using scanning electron microscopy (SEM). Twenty mandibular premolars with completely formed roots were selected and randomly divided into group 1 (irrigation with the Rinsendo system) and group 2 (conventional irrigation). The canals were irrigated with 1 ml of saline at each change of instrument. instrumentation started with a #15 K file and continued up to a #40 K file, which was standardized as the working length instrument. Then, the teeth were sectioned in buccolingual direction and the halves were sputter-coated with gold and examined by SEM. The apical, middle and cervical root canal thirds were evaluated, and the results were analyzed statistically by the Mann-Whitney test for comparison between methods, Kruskal-Wallis test for comparison among thirds, and Miller test for individual comparisons. A significance level of 5% was set for all analyses. The results did not show significant differences (p>0.05) between methods at each third and among thirds for each technique analyzed individually. in conclusion, there was no difference in the cleaning ability of the Rinsendo system and conventional irrigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trying to reduce particle contamination in lubrication systems, industries of the whole world spend millions of dollars each year on the improvement of filtration technology. In this context, by controlling fluid cleanliness, some companies are able to reduce failures rates up to 85 percent. However, in some industries and environments, water is a contaminant more frequently encountered than solid particles, and it is often seen as the primary cause of component failure. Only one percent of water in oil is enough to reduce life expectancy of a journal bearing by 80 percent. For rolling bearing elements, the situation is worse because water destroys the oil film and, under the extreme temperatures and pressures generated in the load zone of a rolling bearing element, free and emulsified water can result in instantaneous flash-vaporization giving origin to erosive wear. This work studies the effect of water as lubricant contaminant in ball bearings, which simulates a situation that could actually occur in real systems. In a designed bench test, three basic lubricants of different viscosities were contaminated with different contents of water. The results regarding oil and vibration analysis are presented for different bearing speeds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work is to present a frequency domain model to demonstrate the operation of an electromagnetic arrangement for controlling the injection of zero-sequence currents in the electrical system. Considering the diversity of sequential distribution of harmonic components of a current, the device proposed can be used in the process of mitigation of zero-sequence components. This device, here called electromagnetic suppressor, consists of a blocker and filter both electromagnetic, whose joint operation can provide paths of high and low impedances that can be conveniently adjusted in order to search for a desired performance. This study presents physical considerations, mathematical modeling and computer simulations that clearly demonstrate the viability of this application as a more viable alternative in the conception of filtering systems. The performance analysis is based on the frequency response of harmonic transmittances. The efficacy of this technique in direct actions to maximize the harmonic mitigation process is demonstrated. ©2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper is to present a computer model that enables the operation analysis of a tuned filter as an attenuator device of harmonic generated 12 and 18-pulses converters with Y-generalized differential connection. Are presented in this study physical considerations, mathematical modeling and digital simulations in the frequency domain using the software Orcad-Pspice®, which allows a spectral analysis of the harmonic components and supports the search for an optimal filtering process. It is unequivocally demonstrated the feasibility of the application as an alternative to optimize the use of multipulse converters, and enable the operation of this device within the established regulatory standards. The validation of the proposed model is based on results obtained in the time domain using Matlab/Simulink®. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reveals new contributions to the analysis and development of mitigating harmonic distortion devices. Considering the variety of sequential distribution of harmonic current, in the use of passive filters, one can point out the electromagnetic blocking device, which have received particular attention due to its robustness and low cost of installation. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests are carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocking. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to analyze the stress distribution on dentin/adhesive interface (d/a) through a 3-D finite element analysis (FEA) varying the number and diameter of the dentin tubules orifice according to dentin depth, keeping hybrid layer (HL) thickness and TAǴs length constant. Materials and Methods: 3 models were built through the SolidWorks software: SD - specimen simulating superficial dentin (41 x 41 x 82 μm), with a 3 μm thick HL, a 17 μm length Tag, and 8 tubules with a 0.9 μm diameter restored with composite resin. MD - similar to M1 with 12 tubules with a 1.2 μm diameter, simulating medium dentin. DD - similar to M1 with 16 tubules with a 2.5 μm diameter, simulating deep dentin. Other two models were built in order to keep the diameter constant in 2.5 μm: MS - similar to SD with 8 tubules; and MM - similar to MD with 12 tubules. The boundary condition was applied to the base surface of each specimen. Tensile load (0.03N) was performed on the composite resin top surface. Stress field (maximum principal stress in tension - σMAX) was performed using Ansys Wokbench 10.0. Results: The peak of σMAX (MPa) were similar between SD (110) and MD (106), and higher for DD (134). The stress distribution pathway was similar for all models, starting from peritubular dentin to adhesive layer, intertubular dentin and hybrid layer. The peak of σMAX (MPa) for those structures was, respectively: 134 (DD), 56.9 (SD), 45.5 (DD), and 36.7 (MD). Conclusions: The number of dentin tubules had no influence in the σMAX at the dentin/adhesive interface. Peritubular and intertubular dentin showed higher stress with the bigger dentin tubules orifice condition. The σMAX in the hybrid layer and adhesive layer were going down from superficial dentin to deeper dentin. In a failure scenario, the hybrid layer in contact with peritubular dentin and adhesive layer is the first region for breaking the adhesion. © 2011 Nova Science Publishers, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maximum Power Point tracking (MPPT) in photovoltaic (PV) systems may be achieved by controlling either the voltage or current of the PV device. There is no consensus in the technical literature about how is the best choice. This paper provides a comparative analysis performance among current and voltage control using two different MPPT strategies: the perturb and observe (P&O) and the incremental conductance techniques. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The exponential-logarithmic is a new lifetime distribution with decreasing failure rate and interesting applications in the biological and engineering sciences. Thus, a Bayesian analysis of the parameters would be desirable. Bayesian estimation requires the selection of prior distributions for all parameters of the model. In this case, researchers usually seek to choose a prior that has little information on the parameters, allowing the data to be very informative relative to the prior information. Assuming some noninformative prior distributions, we present a Bayesian analysis using Markov Chain Monte Carlo (MCMC) methods. Jeffreys prior is derived for the parameters of exponential-logarithmic distribution and compared with other common priors such as beta, gamma, and uniform distributions. In this article, we show through a simulation study that the maximum likelihood estimate may not exist except under restrictive conditions. In addition, the posterior density is sometimes bimodal when an improper prior density is used. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Although skeletal muscle atrophy and changes in myosin heavy chain (MyHC) isoforms have often been observed during heart failure, their pathophysiological mechanisms are not completely defined. In this study we tested the hypothesis that skeletal muscle phenotype changes are related to myogenic regulatory factors and myostatin/follistatin expression in spontaneously hypertensive rats (SHR) with heart failure. Methods: After developing tachypnea, SHR were subjected to transthoracic echocardiogram. Pathological evidence of heart failure was assessed during euthanasia. Age-matched Wistar-Kyoto (WKY) rats were used as controls. Soleus muscle morphometry was analyzed in histological sections, and MyHC isoforms evaluated by electrophoresis. Protein levels were assessed by Western blotting. Statistical analysis: Student's t test and Pearson correlation. Results: All SHR presented right ventricular hypertrophy and seven had pleuropericardial effusion. Echocardiographic evaluation showed dilation in the left chambers and left ventricular hypertrophy with systolic and diastolic dysfunction in SHR. Soleus weight and fiber cross sectional areas were lower (WKY 3615±412; SHR 2035±224 μm2; P < 0.001), and collagen fractional volume was higher in SHR. The relative amount of type I MyHC isoform was increased in SHR. Myogenin, myostatin, and follistatin expression was lower and MRF4 levels higher in SHR. Myogenin and follistatin expression positively correlated with fiber cross sectional areas and MRF4 levels positively correlated with I MyHC isoform. Conclusion: Reduced myogenin and follistatin expression seems to participate in muscle atrophy while increased MRF4 protein levels can modulate myosin heavy chain isoform shift in skeletal muscle of spontaneously hypertensive rats with heart failure. © 2012 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exercise capacity and quality of life (QOL) are important outcome predictors in patients with systolic heart failure (HF), independent of left ventricular (LV) ejection fraction (LVEF). LV diastolic function has been shown to be a better predictor of aerobic exercise capacity in patients with systolic dysfunction and a New York Heart Association (NYHA) classification >II. We hypothesized that the currently used index of diastolic function E/e' is associated with exercise capacity and QOL, even in optimally treated HF patients with reduced LVEF. This prospective study included 44 consecutive patients aged 55±11 years (27 men and 17 women), with LVEF,0.50 and NYHA functional class I-III, receiving optimal pharmacological treatment and in a stable clinical condition, as shown by the absence of dyspnea exacerbation for at least 3 months. All patients had conventional transthoracic echocardiography and answered the Minnesota Living with HF Questionnaire, followed by the 6-min walk test (6MWT). In a multivariable model with 6MWT as the dependent variable, age and E/e' explained 27% of the walked distance in 6MWT (P=0.002; multivariate regression analysis). No association was found between walk distance and LVEF or mitral annulus systolic velocity. Only normalized left atrium volume, a sensitive index of diastolic function, was associated with decreased QOL. Despite the small number of patients included, this study offers evidence that diastolic function is associated with physical capacity and QOL and should be considered along with ejection fraction in patients with compensated systolic HF.