833 resultados para central venous catheter, complications, intravascular catheter-related bloodstream infection, adult.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cardiac pacemakers are routinely used for the treatment of bradyarrhythmias. Contemporary pacemakers are reliable and allow for a patient specific programming. However, pacemaker replacements due to battery depletion are common (~25 % of all implantation procedures) and bear the risk of complications. Batteryless pacemakers may allow overcoming this limitation. To power a batteryless pacemaker, a mechanism for intracorporeal energy harvesting is required. Such a generator may consist out of subcutaneously implanted solar cells, transforming the small amount of transcutaneously available light into electrical energy. Alternatively, intravascular turbines may harvest energy from the blood flow. Energy may also be harvested from the ventricular wall motion by a dedicated mechanical clockwork converting motion into electrical energy. All these approaches have successfully been tested in vivo. Pacemaker leads constitute another Achilles heel of contemporary pacemakers. Thus, leadless devices are desired. Miniaturized pacemaker circuits and suitable energy harvesting mechanisms (incorporated in a single device) may allow catheter-based implantation of the pacemaker in the heart. Such miniaturized battery- and leadless pacemakers would combine the advantages of both approaches and overcome major limitations of today’s systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study has the purpose of determining the barriers and facilitators to nurses' acceptance of the Johnson and Johnson Protectiv®* Plus IV catheter safety needle device and implications for needlestick injuries at St. Luke's Episcopal Hospital, Houston, Texas. A one-time cross-sectional survey of 620 responding nurses was conducted by this researcher during December, 2000. The study objectives were to: (1) describe the perceived (a) organizational and individual barriers and facilitators and (b) acceptance of implementation of the IV catheter device; (2) examine the relative importance of these predictors; (3) describe (a) perceived changes in needlestick injuries after implementation of the device; (b) the reported incidence of injuries; and (c) the extent of underreporting by nurses; and (4) examine the relative importance of (a) the preceding predictors and (b) acceptance of the device in predicting perceived changes in needlestick injuries. Safety climate and training were evaluated as organizational factors. Individual factors evaluated were experience with the device, including time using it and frequency of use, and background information, including nursing unit, and length of time as a nurse in this hospital and in total nursing career. The conceptual framework was based upon the safety climate model. Descriptive statistics and multiple and logistic regression were utilized to address the study objectives. ^ The findings showed widespread acceptance of the device and a strong perception that it reduced the number of needlesticks. Acceptance was notably predicted by adequate training, appropriate time between training and device use, solid safety climate, and short length of service, in that order. A barrier to acceptance was nurses' longtime of use of previous needle technologies. Over four-fifths of nurses were compliant in always using the device. Compliance had two facilitators: length of time using device and, to a lesser extent, safety climate. Rates of compliance tended to be lower among nurses in units in which the device was frequently used. ^ High quality training and an atmosphere of caring about nurse safety stand out as primary facilitators that other institutions would need to adopt in order to achieve maximum success in implementing safety programs involving utilization of new safety devices. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The primary aim of this dissertation research is to provide epidemiological data on HIV risk-related behaviors among undocumented Central American immigrant women living in Houston, Texas. Between February and May 2010, we used respondent driven sampling (RDS) to recruit 230 Guatemalan, Honduran, and El Salvadoran women, ages 18 to 50 years, living in Houston without a valid United States visa or residency papers. RDS is a probability-based sampling method that utilizes social networks to access members of hidden populations that lack a sampling frame. Participants completed an interview regarding their demographics, access to and utilization of healthcare services, HIV testing, and sexual behaviors. Data from this study were used 1) to describe the prevalence of sexual HIV risk-related behaviors among undocumented Central American immigrant women, comparing those who recently immigrated to the U.S. (within the past five years) to those with more established residency (of over five years); 2) to describe the prevalence of lifetime HIV testing and evaluate its associated factors in this target population; and 3) to describe the effectiveness of RDS to access members of this target population. ^ As described in Paper 1, there was a generally low prevalence of individual HIV risk-related behaviors (i.e., multiple, concurrent, convenience, and casual sexual partnerships) among the undocumented Central American immigrant women in this study. However, there was evidence of HIV risk due to unprotected sex with male partners who have concurrent sexual partnerships. We identified recent immigrants as the subpopulation at greatest risk, as they were significantly more likely than established immigrants to have multiple and/or concurrent sexual partners. As described in Paper 2, the lifetime prevalence of HIV testing was almost 70%. After adjusting for age, number of years living in the U.S., income security, and resource barriers, lifetime HIV testing was significantly associated with being from Honduras, having more than a sixth grade education, having a regular healthcare provider, and having knowledge of available healthcare resources. Finally, as described in Paper 3, RDS was an effective method for obtaining a diverse sample of Central American immigrant women in Houston. ^ This project is the first to use RDS to conduct an HIV behavioral survey among undocumented Central American immigrant women. Our results will inform the design of future research studies and the implementation of HIV prevention activities among undocumented Central American immigrants in the U.S.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The distinction between catheter-associated asymptomatic bacteriuria (CAABU) and catheter-associated urinary tract infection (CAUTI) has only recently been widely appreciated. Our aims were to describe the relationship between CAUTI/CAABU and subsequent bacteremia and to investigate whether CAUTI/CAABU and antimicrobial use was associated with either bacteremia or mortality within 30 days. ^ Methods: Our study design was retrospective cohort. Patients with a urinary catheter and a positive urine culture between October 2010 and June 2011 at a large tertiary care facility were included. A multivariable model for analysis was constructed which controlled for age, race, Charlson co-morbidity score, catheter type and duration, category of organism,antimicrobials and classification of the catheter-associated bacteriuria as CAUTI or CAABU. ^ Results: Data from 444 catheter associated urine culture episodes in 308 unique patients were included in the analysis. Overall mortality was 21.1% (61 of 308 patients) within 30 days. Among the 444 urine culture episodes, 402 (90.5%) of these episodes were associated with antibiotic use. 52 (11.7%) of episodes were associated with bacteremia, but only 3 episodes of bacteremia (0.7% of 444 CAB episodes) were caused by an organism from the urinary tract. One of these episodes was CAABU and the other 2 were CAUTI. Bacteremia within 30 days was associated with having CAUTI rather than CAABU and having an indwelling urinary catheter rather than a condom catheter. The variables which were found to be significant for mortality within 30 days were a higher Charlson co-morbidity score and the presence of Candida in the urine culture. Use of antimicrobial agents to treat the bacteriuria was not associated with an increase or decrease in either bacteremia or mortality. ^ Conclusions: Our findings call into question the practice of giving antimicrobial agents to treat bacteriuria in an inpatient population with nearly universal antimicrobial use. A better practice may be targeted treatment of bacteriuria in patients with risk factors predictive of bacteremia and mortality.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nitric oxide (NO·) does not react significantly with thiol groups under physiological conditions, whereas a variety of endogenous NO donor molecules facilitate rapid transfer to thiol of nitrosonium ion (NO+, with one less electron than NO·). Here, nitrosonium donors are shown to decrease the efficacy of evoked neurotransmission while increasing the frequency of spontaneous miniature excitatory postsynaptic currents (mEPSCs). In contrast, pure NO· donors have little effect (displaying at most only a slight increase) on the amplitude of evoked EPSCs and frequency of spontaneous mEPSCs in our preparations. These findings may help explain heretofore paradoxical observations that the NO moiety can either increase, decrease, or have no net effect on synaptic activity in various preparations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The authors report their knowledge about an uncommon case of isolated vasculitis, restricted to the left sylvian artery during an auto-immune Guillain-Barrè syndrome (GBS), sustained by cytomegalovirus (CMV). An acute cardiopulmonary failure requiring a ventilator and vasopressor support manifested, notwithstanding plasma exchanging and immune-modulating therapy. An IgM-enriched formula administration coincided with a rapid amelioration of GBS and vasculitis to a complete recovery the next month after her discharge to a rehabilitation centre.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The epsilon 4 allele of apolipoprotein E (apoE) is a major risk factor for Alzheimer disease, suggesting that apoE may directly influence neurons in the aging brain. Recent data suggest that apoE-containing lipoproteins can influence neurite outgrowth in an isoform-specific fashion. The neuronal mediators of apoE effects have not been clarified. We show here that in a central nervous system-derived neuronal cell line, apoE3 but not apoE4 increases neurite extension. The effect of apoE3 was blocked at low nanomolar concentrations by purified 39-kDa protein that regulates ligand binding to the low density lipoprotein receptor-related protein (LRP). Anti-LRP antibody also completely abolished the neurite-promoting effect of apoE3. Understanding isoform-specific cell biological processes mediated by apoE-LRP interactions in central nervous system neurons may provide insight into Alzheimer disease pathogenesis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viável

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Deformable Template models are first applied to track the inner wall of coronary arteries in intravascular ultrasound sequences, mainly in the assistance to angioplasty surgery. A circular template is used for initializing an elliptical deformable model to track wall deformation when inflating a balloon placed at the tip of the catheter. We define a new energy function for driving the behavior of the template and we test its robustness both in real and synthetic images. Finally we introduce a framework for learning and recognizing spatio-temporal geometric constraints based on Principal Component Analysis (eigenconstraints).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: The recent availability of the novel oral anticoagulants (NOACs) may have led to a change in the anticoagulation regimens of patients referred to catheter ablation of atrial fibrillation (AF). Preliminary data exist concerning dabigatran, but information regarding the safety and efficacy of rivaroxaban in this setting is currently scarce. Methods: and results Of the 556 consecutive eligible patients (age 61.0 ± 9.6; 74.6% men; 61.2% paroxysmal AF) undergoing AF catheter ablation in our centre (October 2012 to September 2013) and enroled in a systematic standardized 30-day follow-up period: 192 patients were under vitamin K antagonists (VKAs), 188 under rivaroxaban, and 176 under dabigatran. Peri-procedural mortality and significant systemic or pulmonary thromboembolism (efficacy outcome), as well as bleeding events (safety outcome) during the 30 days following the ablation were evaluated according to anticoagulation regimen. During a 12-month time interval, the use of the NOACs in this population rose from <10 to 70%. Overall, the rate of events was low with no significant differences regarding: thrombo-embolic events in 1.3% (VKA 2.1%; rivaroxaban 1.1%; dabigatran 0.6%; P = 0.410); major bleeding in 2.3% (VKA 4.2%; rivaroxaban 1.6%; dabigatran 1.1%; P = 0.112), and minor bleeding 1.4% (VKA 2.1%; rivaroxaban 1.6%; dabigatran 0.6%; P = 0.464). No fatal events were observed. Conclusion: The use of the NOAC in patients undergoing catheter ablation of AF has rapidly evolved (seven-fold) over 1 year. These preliminary data suggest that rivaroxaban and dabigatran in the setting of catheter ablation of AF are efficient and safe, compared with the traditional VKA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIMS Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.