914 resultados para carpal joint


Relevância:

20.00% 20.00%

Publicador:

Resumo:

When joint (X) over bar and R charts are in use, samples of fixed size are regularly taken from the process, and their means and ranges are plotted on the (X) over bar and R charts, respectively. In this article, joint (X) over bar and R charts have been used for monitoring continuous production processes. The sampling is performed, in two stages. During the first stage, one item of the sample is inspected and, depending on the result, the sampling is interrupted if the process is found to be in control; otherwise, it goes on to the second stage, where the remaining sample items are inspected. The two-stage sampling procedure speeds up the detection of process disturbances. The proposed joint (X) over bar and R charts are easier to administer and are more efficient than the joint (X) over bar and R charts with variable sample size where the quality characteristic of interest can be evaluated either by attribute or variable. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong photoluminescent emission has been measured at room temperature for noncrystalline BaT'O-3 (BT) perovskite powders. A joint experimental and theoretical study has been carried out to rationalize this phenomenon. From the experimental side, BT powder samples have been synthesized following a soft chemical processing, their crystal structure has been confirmed by x-ray data and the corresponding photoluminescence (PL) properties have been measured. Only the structurally disordered samples present PL at room temperature. From the theoretical side, first-principles quantum-mechanical techniques, based on density-functional theory at the B3LYP level, have been employed to study the electronic structure of crystalline (BT-c) and asymmetric (BT-a) models. Theoretical and experimental results are found to be consistent and their confrontation leads to an interpretation of the PL apparition at room temperature in the structurally disordered powders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A joint experimental and theoretical study has been carried out to rationalize for the first time the photoluminescence (PL) properties of disordered CaWO4 (CWO) thin films. From the experimental side, thin films of CWO have been synthesized following a soft chemical processing, their structure has been confirmed by X-ray diffraction data and corresponding PL properties have been measured using the 488 nm line of an argon ion laser. Although we observe PL at room temperature for the crystalline thin films, the structurally disordered samples present much more intense emission. From the theoretical side, first principles quantum mechanical calculations, based on density functional theory at B3LYP level, have been employed to study the electronic structure of a crystalline (CWO-c) and asymmetric (CWO-a) periodic model. Electronic properties are analyzed in the light of the experimental results and their relevance in relation to the PL behavior of CWO is discussed. The symmetry breaking process on going from CWO-c to CWO-a creates localized electronic levels above the valence band and a negative charge transfer process takes place from threefold, WO3, to fourfold, WO4,. tungsten coordinations. The correlation of both effects seems to be responsible for the PL of amorphous CWO. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The joint sound is a common sign in TMD, the diagnosis is important to establish the treatment of pathological alterations which occur in the TMJ. In this study, two groups were selected: 1, Asymptomatic volunteers; and 2, Symptomatic patients who were diagnosed in a clinical examination. After the initial examination, they were submitted to evaluation using electrovibratography (SonoPAK II, BioResearch Assoc., Inc., Milwaukee, Wisconsin). The analysis of results indicated that the averages of the vibratory energy in the symptomatic group presented higher values in all stages of the mandibular movement when compared to the averages of vibratory energy registered in the asymptomatic group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The articular disc of the temporomandibular joint was studied in a foetuses and children group (GI), a dentate group of adults (GII) and an edentulous, elderly group of humans (GIII) by light microscopy. The main, constituent bundles of type I collagen fibres are stratified and are orientated sagittally, transversely and obliquely in the middle portion of the disc. In the thick, posterior portion, transverse bundles constitute the main feature. In the anterior portion of the disc, the fibres are sagittally and obliquely orientated. Type III. collagen fibres, intermingled with type I collagen fibres are present in all groups. The disc is cellular in nature in foetuses and children becoming more fibrous with age. Chondroid cells are observed in all portions of the discs in groups GII and GIII. Elastic fibres are numerous in GI discs and decrease in number in the disc with age. These fibres lie parallel to the collagen fibres in all three portions of the three groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The authors compared the efficacy of bilateral balanced and canine guidance (occlusal) splints in the treatment of temporomandibular joint (TMJ) pain in subjects who experienced joint clicking with a nonoccluding splint in a double-blind, controlled randomized clinical trial.Methods. The authors randomly assigned 57 people with signs of disk displacement and TMJ pain into three groups according to the type of splint: bilateral balanced, canine guidance and nonoccluding. The authors followed the groups for six months using analysis of a visual analog scale (VAS), palpation of the TMJ and masticatory muscles, mandibular movements and joint sounds. They used repeated analysis of variance and a XI test to test the hypothesis.Results. The type of guidance used did not influence the pain reduction; yet both occlusal splints were superior to the nonoccluding splint, on the basis of the VAS. Despite similar outcomes in relation to opening, left; lateral and protrusive movements, TMJ and muscle pain on palpation, subjects who used the occlusal splints had improved clinical outcomes. The frequency of joint noises decreased over time, with no significant differences among groups. Subjects in the groups using the occlusal splints reported more comfort.Conclusion. The type of lateral guidance did not influence the subjects'; improvement: All of the subjects had a general improvement on the VAS, though subjects in the occlusal splint groups had better results that did subjects in the nonoccluding splint group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrafine ordered and disordered SrZrO3 powders were prepared by the polymeric precursor method. The structural evolution from structural disorder to order was monitored by X-ray diffraction and X-ray absorption near-edge spectroscopy. Complex cluster vacancies [ZrO5 center dot V-O(Z)] and [SrOII center dot V-O(Z)] (where V-O(Z) = V-O(X), V-O(center dot) and V-O(center dot center dot)) were proposed for disordered powders. The intense violet-blue light photoluminescence emission measured at room temperature in the disordered powders was attributed to complex cluster vacancies. High-level quantum mechanical calculations within the density functional theory framework were used to interpret the experimental results. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The T-2 and the generalized variance vertical bar S vertical bar charts are used for monitoring the mean vector and the covariance matrix of multivariate processes. In this article, we propose for bivariate processes the use of the T-2 and the VMAX charts. The points plotted on the VMAX chart correspond to the maximum of the sample variances of the two quality characteristics. The reason to consider the VMAX statistic instead of the generalized variance vertical bar S vertical bar is the user's familiarity with the computation of simple sample variances; we can't say the same with regard to the computation of the generalized variance vertical bar S vertical bar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the feasibility and validity of sampling blood from the carpal pad in hospitalised healthy and diabetic dogs. METHODS The carpal pad was compared to the ear as a sampling site in 60 dogs (30 healthy and 30 diabetic dogs). RESULTS Lancing the pads was very well tolerated. The average glucose concentrations in blood samples obtained from the ears and carpal pads exhibited a strong positive correlation (r = 0.938) and there were no significant differences between them (P = 0.914). In addition, 98.3% of the values obtained were clinically acceptable when assessed by the error grid analysis. CLINICAL SIGNIFICANCE The carpal pad is a good alternative sampling site for home monitoring, especially in animals with a soft and/or light-coloured pad.