937 resultados para Wind power -- Equipment and supplies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reliability of power supply is related, among other factors, to the control and protection devices allocation in feeders of distribution systems. In this way, optimized allocation of sectionalizing switches and protection devices in strategic points of distribution circuits, improves the quality of power supply and the system reliability indices. In this work, it is presented a mixed integer non-linear programming (MINLP) model, with real and binary variables, for the sectionalizing switches and protection devices allocation problem, in strategic sectors, aimed at improving reliability indices, increasing the utilities billing and fulfilling exigencies of regulatory agencies for the power supply. Optimized allocation of protection devices and switches for restoration, allows that those faulted sectors of the system can be isolated and repaired, re-managing loads of the analyzed feeder into the set of neighbor feeders. Proposed solution technique is a Genetic Algorithm (GA) developed exploiting the physical characteristics of the problem. Results obtained through simulations for a real-life circuit, are presented. © 2004 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incentives for using wind power and the increasing price of energy might generate in a relatively short time a scenario where low voltage customers opt to install roof-top wind turbines. This paper focuses on evaluating the effects of such situation in terms of energy consumption, loss reduction, reverse power flow and voltage profiles. Various commercially-available roof-top wind turbines are installed in two secondary distribution circuits considering real-life wind speed data and seasonal load demand. Results are presented and discussed. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is to study voltage control and energy balance of a split DC bus topology within a power electronics equipment connected to the AC mains, such as UPS systems, wind power generators, active filters and FACTS devices. A typical configuration in such equipment has two mains connected converters sharing a common DC bus, one series connected and the other parallel connected. The DC bus is usually composed by a battery or a capacitor bank. In the proposed topology, the DC bus is divided in two sides, interconnected with a buck-boost converter, which controls power flow and DC voltage on both sides. © 2009 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical remote sensing techniques have obvious advantages for monitoring gas and aerosol emissions, since they enable the operation over large distances, far from hostile environments, and fast processing of the measured signal. In this study two remote sensing devices, namely a Lidar (Light Detection and Ranging) for monitoring the vertical profile of backscattered light intensity, and a Sodar (Acoustic Radar, Sound Detection and Ranging) for monitoring the vertical profile of the wind vector were operated during specific periods. The acquired data were processed and compared with data of air quality obtained from ground level monitoring stations, in order to verify the possibility of using the remote sensing techniques to monitor industrial emissions. The campaigns were carried out in the area of the Environmental Research Center (Cepema) of the University of São Paulo, in the city of Cubatão, Brazil, a large industrial site, where numerous different industries are located, including an oil refinery, a steel plant, as well as fertilizer, cement and chemical/petrochemical plants. The local environmental problems caused by the industrial activities are aggravated by the climate and topography of the site, unfavorable to pollutant dispersion. Results of a campaign are presented for a 24- hour period, showing data of a Lidar, an air quality monitoring station and a Sodar. © 2011 SPIE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing use of sensitive loads in the electric power system, especially in industrial applications, increases voltage sags related production losses considerably, stimulating a demand for power electronics' based solutions to mitigate the effects of such problems. This paper shows the implementation and some industrial certification tests of a power equipment prototype designed to correct sags and swells, a dynamic voltage restorer, which is one of the many possible solutions for voltage sags and swells problems Experimental results of a 75kVA prototype are shown both in laboratory and full load conditions, in a certification institution (IEE-USP). © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, distortion). The performance factors are capable to characterize the load under different operating conditions, considering also the effect of non-negligible line impedances and supply voltage deterioration. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymeric insulation is an increasing tendency in projects and maintenance of electrical networks for power distribution and transmission. Electrical power devices (e. g., insulators and surge arresters) developed by using polymeric insulation presents many advantages compared to the prior power components using ceramic insulation, such as: a better performance under high pollution environment; high hydrophobicity; high resistance to mechanical, electrical and chemical stresses. The practice with silicone insulators in polluted environments has shown that the ideal performance is directly related to insulator design and polymer formulation. One of the most common misunderstandings in the design of silicone compounds for insulators is the amount of inorganic load used in their formulation. This paper attempts to clarify how the variation of the inorganic load amount affects physicochemical characteristics of different silicone compounds. The physicochemical evaluation is performed from several measurements, such as: density, hardness, elongation, tensile strength. In addition, the evaluation of the physicochemical structure is carried out using infrared test and scanning electronic microscopy (SEM). The electrical analysis is performed from the electric tracking wheel and erosion test, in agreement with the recommendation of the International Electrotechnical Commission (IEC). (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actually the energy efficiency is making more space in the industry, due to the search for the sustainability, the electrical energy costs reduction, the goals achievement or the efficiency of production processes. In consumer goods industries, such a beverage industry, as the work is based, the productivity is directly related to the electrical energy consumption. The development of methodologies and/or routines, in addition to some tools which allow to align more efficiently these two aspects (production and consumption of electrical energy), in the viewpoint of the Energy Conservation, is very important. In this case, the study will show the Plant Modulation concepts, a production management methodology, based in some factors related to the productive process, installed equipment, production supplies and energy cost. The proposed methodology was implanted in a plant along 2015 and show the results, in face to confirm its efficiency. Finally, in this study, it was shown the capacity of Plant Modulation to positively impact in the energy efficiency inside a big industry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actually the energy efficiency is making more space in the industry, due to the search for the sustainability, the electrical energy costs reduction, the goals achievement or the efficiency of production processes. In consumer goods industries, such a beverage industry, as the work is based, the productivity is directly related to the electrical energy consumption. The development of methodologies and/or routines, in addition to some tools which allow to align more efficiently these two aspects (production and consumption of electrical energy), in the viewpoint of the Energy Conservation, is very important. In this case, the study will show the Plant Modulation concepts, a production management methodology, based in some factors related to the productive process, installed equipment, production supplies and energy cost. The proposed methodology was implanted in a plant along 2015 and show the results, in face to confirm its efficiency. Finally, in this study, it was shown the capacity of Plant Modulation to positively impact in the energy efficiency inside a big industry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Our objective was to relate immunological data for healthy but sedentary elderly women to aerobic power, strength, and mood state. Methods: We measured peak aerobic power and one-repetition maximum strength along with mood (depression and fatigue), quality of life and carbohydrate intake on 42 women aged 60-77 years. Standard immunological techniques determined natural killer cell count and cytotoxic activity (NKCA), proliferative responses to phytohemaglutinin and OKT3, various lymphocyte subpopulations (CD3(+), CD3(-)CD19(+), CD56(+), CD4(+), CD8(+), CD56(dim) and CD56(bright)), and markers of activation, maturation, down-regulation and susceptibility to apoptosis (CD25(+), CD28(+), CD45RA(+), CD45RO(+), CD69(+), CD95(+), HLA-DR+). Results: Correlations of immune parameters with aerobic power and strength were very similar for absolute and relative immunological data. In the group as a whole, the only correlation with aerobic power was -0.35 (relative CD4(+)CD69(+) count), but in subjects with values <22.6 mL kg(-1) min(-1) correlations ranged from -0.57 (relative CD4(+)CD45RO(+)) to 0.92 (absolute CD56(dim)HLA-DR+). In terms of muscle strength, univariate correlation coefficients ranged from -0.34 (relative and absolute CD3(+)CD4(+)CD8(+)) to +0.48 (absolute CD3(+)HLA-DR+.) and +0.50 (absolute CD8(+)CD45RA(+)CD45RO(+)). Neither NKCA nor lymphocyte proliferation were correlated with aerobic power or muscle strength. Although mood state and quality of life can sometimes be influenced by an individual's fitness level, our multivariate analyses suggested that depression, fatigue and quality of life were more important determinants of immune profile than our fitness measures. Conclusions: Psychological changes associated with aging may have a substantial adverse effect upon the immune system, and immunological function may be enhanced more by addressing these issues than by focusing upon aerobic or resistance training. (C) 2012 Elsevier Inc. All rights reserved.