962 resultados para Ultrasonics in medicine


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Antiretroviral therapy has changed the natural history of human immunodeficiency virus (HIV) infection in developed countries, where it has become a chronic disease. This clinical scenario requires a new approach to simplify follow-up appointments and facilitate access to healthcare professionals. Methodology: We developed a new internet-based home care model covering the entire management of chronic HIV-infected patients. This was called Virtual Hospital. We report the results of a prospective randomised study performed over two years, comparing standard care received by HIV-infected patients with Virtual Hospital care. HIV-infected patients with access to a computer and broadband were randomised to be monitored either through Virtual Hospital (Arm I) or through standard care at the day hospital (Arm II). After one year of follow up, patients switched their care to the other arm. Virtual Hospital offered four main services: Virtual Consultations, Telepharmacy, Virtual Library and Virtual Community. A technical and clinical evaluation of Virtual Hospital was carried out. Findings: Of the 83 randomised patients, 42 were monitored during the first year through Virtual Hospital (Arm I) and 41 through standard care (Arm II). Baseline characteristics of patients were similar in the two arms. The level of technical satisfaction with the virtual system was high: 85% of patients considered that Virtual Hospital improved their access to clinical data and they felt comfortable with the videoconference system. Neither clinical parameters [level of CD4 + T lymphocytes, proportion of patients with an undetectable level of viral load (p = 0.21) and compliance levels 90% (p = 0.58)] nor the evaluation of quality of life or psychological questionnaires changed significantly between the two types of care. Conclusions: Virtual Hospital is a feasible and safe tool for the multidisciplinary home care of chronic HIV patients. Telemedicine should be considered as an appropriate support service for the management of chronic HIV infection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Congenital hypogonadotropic hypogonadism (CHH) and split hand/foot malformation (SHFM) are two rare genetic conditions. Here we report a clinical entity comprising the two. METHODS: We identified patients with CHH and SHFM through international collaboration. Probands and available family members underwent phenotyping and screening for FGFR1 mutations. The impact of identified mutations was assessed by sequence- and structure-based predictions and/or functional assays. RESULTS: We identified eight probands with CHH with (n = 3; Kallmann syndrome) or without anosmia (n = 5) and SHFM, seven of whom (88%) harbor FGFR1 mutations. Of these seven, one individual is homozygous for p.V429E and six individuals are heterozygous for p.G348R, p.G485R, p.Q594*, p.E670A, p.V688L, or p.L712P. All mutations were predicted by in silico analysis to cause loss of function. Probands with FGFR1 mutations have severe gonadotropin-releasing hormone deficiency (absent puberty and/or cryptorchidism and/or micropenis). SHFM in both hands and feet was observed only in the patient with the homozygous p.V429E mutation; V429 maps to the fibroblast growth factor receptor substrate 2α binding domain of FGFR1, and functional studies of the p.V429E mutation demonstrated that it decreased recruitment and phosphorylation of fibroblast growth factor receptor substrate 2α to FGFR1, thereby resulting in reduced mitogen-activated protein kinase signaling. CONCLUSION: FGFR1 should be prioritized for genetic testing in patients with CHH and SHFM because the likelihood of a mutation increases from 10% in the general CHH population to 88% in these patients.Genet Med 17 8, 651-659.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La parada cardiorrespiratoria (PCR) dentro del hospital es considerada una emergencia vital y está demostrado que existe una relación directa entre la respuesta asistencial y la mortalidad asociada a este evento. Los resultados del tratamiento de la PCR son un indicador de calidad de los centros sanitarios. En el caso en concreto de España, la mayoría de hospitales no disponen de un sistema organizado e integral de atención a la PCR. A pesar de los avances en medicina y tecnológicos, la tasa de supervivencia no ha variado significativamente en los últimos 30 años por lo que se ha de considerar como un problema social, económico y sanitario de gran magnitud que cabe abordar con todas las herramientas disponibles. Objetivos: Conocer cómo se organiza la reanimación cardiopulmonar (RCP) dentro del hospital y conocer los planes integrales de RCP publicados por los hospitales españoles. Metodología: Se realiza una revisión de la literatura a través de las bibliotecas indexadas Pubmed y Web of Science mediante criterios de inclusión/exclusión, uso de operadores booleanos y búsqueda bibliográfica manual. Además se realiza una entrevista a un médico referente nacional en la investigación sobre RCP. Resultados: Se han encontrado 7 planes integrales para la atención a la PCR y solo 2 de ellos están avalados por el Plan Nacional de RCP (PNRCP), miembro del Consejo Español de RCP (CERCP). Conclusiones: Existe una falta de publicaciones por parte de los hospitales españoles sobre planes integrales para la organización de la RCP que cumplan los criterios de calidad necesarios. Si bien todos los hospitales disponen de protocolos propios dirigidos a sus profesionales para la actuación en caso de PCR, estos son de uso interno y solo tienen en común entre ellos el hecho de seguir las recomendaciones de las guías del European Resuscitation Council (ERC). III Es necesario que los centros sanitarios fomenten y compartan su actividad investigadora sobre el tema. Palabras clave: parada cardíaca hospitalaria, resucitación cardiopulmonar, Plan hospitalario de resucitación.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: We propose the use of a retrospectively gated cine fast spin echo (FSE) sequence for characterization of carotid artery dynamics. The aim of this study was to compare cine FSE measures of carotid dynamics with measures obtained on prospectively gated FSE images. METHODS: The common carotid arteries in 10 volunteers were imaged using two temporally resolved sequences: (i) cine FSE and (ii) prospectively gated FSE. Three raters manually traced a common carotid artery area for all cardiac phases on both sequences. Measured areas and systolic-diastolic area changes were calculated and compared. Inter- and intra-rater reliability were assessed for both sequences. RESULTS: No significant difference between cine FSE and prospectively gated FSE areas were observed (P = 0.36). Both sequences produced repeatable cross-sectional area measurements: inter-rater intraclass correlation coefficient (ICC) = 0.88 on cine FSE images and 0.87 on prospectively gated FSE images. Minimum detectable difference (MDD) in systolic-diastolic area was 4.9 mm(2) with cine FSE and 6.4 mm(2) with prospectively gated FSE. CONCLUSION: This cine FSE method produced repeatable dynamic carotid artery measurements with less artifact and greater temporal efficiency compared with prospectively gated FSE. Magn Reson Med 74:1103-1109, 2015. © 2014 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In diffusion MRI, traditional tractography algorithms do not recover truly quantitative tractograms and the structural connectivity has to be estimated indirectly by counting the number of fiber tracts or averaging scalar maps along them. Recently, global and efficient methods have emerged to estimate more quantitative tractograms by combining tractography with local models for the diffusion signal, like the Convex Optimization Modeling for Microstructure Informed Tractography (COMMIT) framework. In this abstract, we show the importance of using both (i) proper multi-compartment diffusion models and (ii) adequate multi-shell acquisitions, in order to evaluate the accuracy and the biological plausibility of the tractograms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report the case of glandular tularemia that developed in a man supposedly infected by a tick bite in Western Switzerland. Francisella tularensis (F. tularensis) was identified. In Europe tularemia most commonly manifests itself as ulcero-glandular or glandular disease; the diagnosis of tularemia may be delayed in glandular form where skin or mucous lesion is absent, particularly in areas which are assumed to have a low incidence of the disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a qualidade dos monitores de diagnóstico e tratamento de imagem digital em radiologia convencional (raios X) com base nos níveis de luminância. Fez-se a medição da iluminância dos postos de trabalho onde estavam os monitores. MATERIAIS E MÉTODOS: A medição da luminância foi realizada usando-se um detector Unfors Xi Light em cinco instituições, com 23 monitores primários e 22 secundários, sendo 6 usados em urgência, seguindo o método descrito no relatório TG18 da American Association of Physicists in Medicine (AAPM). O instrumento de medida utilizado foi o Delta Ohm HD 9221 luximeter. RESULTADOS: Para as recomendações da AAPM, tanto monitores primários como secundários cumpriram, no geral, os níveis de tolerância. No caso dos níveis de iluminância, nos locais de trabalho dos monitores primários encontravam-se ligeiramente acima do intervalo recomendado. Quanto às recomendações do The Royal College of Radiologists (RCR), os monitores que respeitaram os níveis recomendados estavam em minoria, embora as diferenças não fossem significativas. CONCLUSÃO: Em geral, os resultados foram satisfatórios, embora os monitores não fossem adequados para atingir as recomendações exigentes do RCR. Os níveis de referência entre os monitores primários e secundários deveriam aproximar-se, de modo a garantir a qualidade de imagem. Os monitores para visualização e diagnóstico de imagens médicas devem ser regularmente avaliados para manter um sistema com a qualidade exigida, dada a função que desempenham.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new approach to mammographic mass detection is presented in this paper. Although different algorithms have been proposed for such a task, most of them are application dependent. In contrast, our approach makes use of a kindred topic in computer vision adapted to our particular problem. In this sense, we translate the eigenfaces approach for face detection/classification problems to a mass detection. Two different databases were used to show the robustness of the approach. The first one consisted on a set of 160 regions of interest (RoIs) extracted from the MIAS database, being 40 of them with confirmed masses and the rest normal tissue. The second set of RoIs was extracted from the DDSM database, and contained 196 RoIs containing masses and 392 with normal, but suspicious regions. Initial results demonstrate the feasibility of using such approach with performances comparable to other algorithms, with the advantage of being a more general, simple and cost-effective approach

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El càncer de mama és una de les causes de més mortalitat entreles dones dels països desenvolupats. És tractat d'una maneramés eficient quan es fa una detecció precoç, on les tècniques d'imatge són molt importants. Una de les tècniques d'imatge més utilitzades després dels raigs-X són els ultrasons. A l'hora de fer un processat d'imatges d'ultrasò, els experts en aquest camp es troben amb una sèrie de limitacions en el moment d'utilitzar uns filtrats per les imatges, quan es fa ús de determinades eines. Una d'aquestes limitacions consisteix en la falta d'interactivitat que aquestes ens ofereixen. Per tal de solventar aquestes limitacions, s'ha desenvolupat una eina interactiva que permet explorar el mapa de paràmetres visualitzant el resultat del filtrat en temps real, d'una manera dinàmica i intuïtiva. Aquesta eina s'ha desenvolupat dins l'entorn de visualització d'imatge mèdica MeVisLab. El MeVisLab és un entorn molt potent i modular pel desenvolupament d'algorismes de processat d'imatges, visualització i mètodes d'interacció, especialment enfocats a la imatge mèdica. A més del processament bàsic d'imatges i de mòduls de visualització, inclou algorismes avançats de segmentació, registre i moltes análisis morfològiques i funcionals de les imatges.S'ha dut a terme un experiment amb quatre experts que, utilitzantl'eina desenvolupada, han escollit els paràmetres que creien adientsper al filtrat d'una sèrie d'imatges d'ultrasò. En aquest experiments'han utilitzat uns filtres que l'entorn MeVisLab ja té implementats:el Bilateral Filter, l'Anisotropic Difusion i una combinació d'un filtrede Mediana i un de Mitjana.Amb l'experiment realitzat, s'ha fet un estudi dels paràmetres capturats i s'han proposat una sèrie d'estimadors que seran favorables en la majoria dels casos per dur a terme el preprocessat d'imatges d'ultrasò

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study sought to assess the impact of health care professional (HCP) communication on breast cancer patients across the acute care process as perceived by patients. Methodological approach was based on eight focus groups conducted with a sample of patients (n ¼ 37) drawn from 15 Spanish Regions; thematic analysis was undertaken using the National Cancer Institute (NCI) framework of HCP communication as the theoretical basis. Relevant results of this study were the identification of four main communication components: (1) reassurance in coping with uncertainty after symptom detection and prompt access until confirmed diagnosis; (2) fostering involvement before delivering treatments, by anticipating information on practical and emotional illness-related issues; (3) guidance on the different therapeutic options, through use of clinical scenarios; and, (4) eliciting the feeling of emotional exhaustion after ending treatments and addressing the management of potential treatment-related effects. These communication-related components highlighted the need for a comprehensive approach in this area of cancer care

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polyhydroxyalkanoates (PHAs) are carbon and energy storage materials that are accumulated as intracellular granules in a variety of microorganisms during unbalanced growth. PHAs have drawn attention due to their properties similar to conventional plastics and complete biodegradability. They can be used for food and cosmetics packaging, and in medicine and agriculture. However, their applicability is reduced because of their high production cost compared to conventional plastics. An overview on production strategies of poly(3-hydroxybutyrate) and poly(3-hydroxybutyrate-co-3-hydroxyvalerate) aiming at reducing the production costs is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Natural products have been utilized by humans since ancient times and the relief and cure of their diseases was the first purpose for using natural products in medicine. The history of the oriental and occidental civilizations is very rich in examples of the utilization of natural products in medicine and health care. Chinese traditional medicine is one of the most important examples of how natural products can be efficient in the treatment of diseases, and it points to the importance of scientific research on natural products, concerning the discovery of new active chemical entities. The complexity, chemical diversity and biological properties of natural products always fascinated people, and during the last 200 years, this led to the discovery of important new drugs. In the last 30 years, the development of new bioassay techniques, biotechnology methods, bio-guided phytochemical studies, automated high throughput screening and high performance analytical methods, have introduced new concepts and possibilities of rational drug design and drug discovery. In this context, natural products have played an important and decisive role in the development of modern medicinal chemistry.