962 resultados para Tunnel diodes
Resumo:
In the event of a release of toxic gas in the center of London, the emergency services would need to determine quickly the extent of the area contaminated. The transport of pollutants by turbulent flow within the complex street and building architecture of cities is not straightforward, and we might wonder whether it is at all possible to make a scientifically-reasoned decision. Here we describe recent progress from a major UK project, ‘Dispersion of Air Pollution and its Penetration into the Local Environment’ (DAPPLE, www.dapple.org.uk). In DAPPLE, we focus on the movement of airborne pollutants in cities by developing a greater understanding of atmospheric flow and dispersion within urban street networks. In particular, we carried out full-scale dispersion experiments in central London (UK) during 2003, 2004, 2007, and 2008 to address the extent of the dispersion of tracers following their release at street level. These measurements complemented previous studies because (i) our focus was on dispersion within the first kilometer from the source, when most of the material was expected to remain within the street network rather than being mixed into the boundary layer aloft, (ii) measurements were made under a wide variety of meteorological conditions, and (iii) central London represents a European, rather than North American, city geometry. Interpretation of the results from the full-scale experiments was supported by extensive numerical and wind tunnel modeling, which allowed more detailed analysis under idealized and controlled conditions. In this article, we review the full-scale DAPPLE methodologies and show early results from the analysis of the 2007 field campaign data.
Resumo:
Resistivity imaging was carried out on four large Roman barrows at Bartlow in Cambridgeshire. The geophysical survey formed part of a wider research project designed to record and assess the landscape context of the largest surviving Roman burial mounds in Britain. The barrows today range in height from 6.6 m to 13.2 m and their steep profile loosed particular practical and modelling challenges. Data were obtained using a Campus Geopulse resistance meter with up to 50 electrodes spaced at 1 m intervals and lines up to 76 m long. A total of 24 lines was obtained. Topographic corrections were applied to the pseudosections, whichwere inverted using Res 2 Dinv and Res3 Dinv. Resistivity imaging was particularly successful in identifying evidence for the antiquarian explorations of the site. Central collapse features or in-filled tunnels image as high resistance features in all barrows and in one (Barrow IV) there is also a low resistance feature in the approximate position of a known antiquarian tunnel. Barrow VI had a thick covering of high-resistivity that may relate to nineteenth century landscaping and reconstruction of this monument. Resistivity imaging also revealed possible evidence for ancient revetments in all four large barrows. Copyright (c) 2006 John Wiley & Sons, Ltd.
Resumo:
Direct numerical simulations of turbulent flow over regular arrays of urban-like, cubical obstacles are reported. Results are analysed in terms of a formal spatial averaging procedure to enable interpretation of the flow within the arrays as a canopy flow, and of the flow above as a rough wall boundary layer. Spatial averages of the mean velocity, turbulent stresses and pressure drag are computed. The statistics compare very well with data from wind-tunnel experiments. Within the arrays the time-averaged flow structure gives rise to significant 'dispersive stress' whereas above the Reynolds stress dominates. The mean flow structure and turbulence statistics depend significantly on the layout of the cubes. Unsteady effects are important, especially in the lower canopy layer where turbulent fluctuations dominate over the mean flow.
Resumo:
Cycloaddition reactions have been employed in polymer synthesis since the mid-nineteen sixties. This critical review will highlight recent notable advances in this field. For example, [2 + 2] cycloaddition reactions have been utilized in numerous polymerizations to enable the construction of strained polymer systems such as poly(2-azetidinone)s that can, in turn, afford polyfunctional beta-amino acid derived polymers. Polymers have also been synthesized successfully via (3 + 2) cycloaddition methods utilizing both thermal and high-pressure conditions. 'Click chemistry'-a process involving the reaction of azides with olefins, has also been adopted to generate linear and hyperbranched polymer architectures in a very efficient manner. [4 + 2] Cycloadditions have also been utilized under thermal and high-pressure conditions to produce rigid polymers such as polyimides and polyphenylenes. These cycloaddition polymerization methods afford polymers with potential for use in high performance polymers applications such as high temperature resistant coatings and polymeric organic light emitting diodes.
Resumo:
This paper discusses experimental and theoretical investigations and Computational Fluid Dynamics (CFD) modelling considerations to evaluate the performance of a square section wind catcher system connected to the top of a test room for the purpose of natural ventilation. The magnitude and distribution of pressure coefficients (C-p) around a wind catcher and the air flow into the test room were analysed. The modelling results indicated that air was supplied into the test room through the wind catcher's quadrants with positive external pressure coefficients and extracted out of the test room through quadrants with negative pressure coefficients. The air flow achieved through the wind catcher depends on the speed and direction of the wind. The results obtained using the explicit and AIDA implicit calculation procedures and CFX code correlate relatively well with the experimental results at lower wind speeds and with wind incidents at an angle of 0 degrees. Variation in the C-p and air flow results were observed particularly with a wind direction of 45 degrees. The explicit and implicit calculation procedures were found to be quick and easy to use in obtaining results whereas the wind tunnel tests were more expensive in terms of effort, cost and time. CFD codes are developing rapidly and are widely available especially with the decreasing prices of computer hardware. However, results obtained using CFD codes must be considered with care, particularly in the absence of empirical data.
Resumo:
Experimental wind tunnel and smoke visualisation testing and CFD modelling were conducted to investigate the effect of air flow control mechanism and heat source inside rooms on wind catchers/towers performance. For this purpose, a full-scale wind catcher was connected to a test room and positioned centrally in an open boundary wind tunnel. Pressure coefficients (C-p's) around the wind catcher and air flow into the test room were established. The performance of the wind catcher depends greatly on the wind speed and direction. The incorporation of dampers and egg crate grille at ceiling level reduces and regulates the air flow rate with an average pressure loss coefficient of 0.01. The operation of the wind catcher in the presence of heat sources will potentially lower the internal temperatures in line with the external temperatures.
Resumo:
Wind catcher systems have been employed in buildings in the Middle East for many centuries and they are known by different names in different parts of the region. Recently there has been an increase in the application of this approach for natural ventilation and passive cooling in the UK and other countries. This paper presents the results of experimental wind tunnel and smoke visualisation testing, combined with CFD modelling, to investigate the performance of the wind catcher. For this purpose, a full-scale commercial system was connected to a test room and positioned centrally in an open boundary wind tunnel. Because much ventilation design involves the use of computational fluid dynamics, the measured performance of the system was also compared against the results of CFD analysis. Configurations included both a heated and unheated space to determine the impact of internal heat sources on airflow rate. Good comparisons between measurement and CFD analysis were obtained. Measurements showed that sufficient air change could be achieved to meet both air quality needs and passive cooling.
Resumo:
Schottky barrier diodes have been integrated into on-chip rectangular waveguides. Two novel techniques have been developed to fabricate diodes with posts suitable for integration into waveguides. One technique produces diodes with anode diameters of the order of microns with post heights from 90 to 125 microns and the second technique produces sub-micron anodes with post heights around 20 microns. A method has been developed to incorporate these structures into a rectangular waveguide and provide a top contact onto the anode which could be used as an I.F. output in a mixer circuit. Devices have been fabricated and D.C. characterized.
Resumo:
A novel wide-band noise source for millimetre-wave spectrometry is described. It uses power combined Schottky diodes, reverse biased to avalanche breakdown, mounted in a wide-band tapered slot antenna. Power has been produced from 15 to 200 GHz with an equivalent temperature of 28200 K at 40 GHz.
Resumo:
A series of scale model measurements of transverse electromagnetic mode tapered slot antennas are presented. They show that the beam launched by this type of antenna is astigmatic. It is shown how an off-axis spherical mirror can be used to correct this astigmatism to allow efficient coupling to quasi-optical systems. A millimetre wave antenna and mirror combination is described and, with the aid of solid state noise diodes, the coupling of the launched beam to a quasi-optical spectrometer is shown to be in good agreement with that predicted by the scale model measurements.
Resumo:
Accurate estimates for the fall speed of natural hydrometeors are vital if their evolution in clouds is to be understood quantitatively. In this study, laboratory measurements of the terminal velocity vt for a variety of ice particle models settling in viscous fluids, along with wind-tunnel and field measurements of ice particles settling in air, have been analyzed and compared to common methods of computing vt from the literature. It is observed that while these methods work well for a number of particle types, they fail for particles with open geometries, specifically those particles for which the area ratio Ar is small (Ar is defined as the area of the particle projected normal to the flow divided by the area of a circumscribing disc). In particular, the fall speeds of stellar and dendritic crystals, needles, open bullet rosettes, and low-density aggregates are all overestimated. These particle types are important in many cloud types: aggregates in particular often dominate snow precipitation at the ground and vertically pointing Doppler radar measurements. Based on the laboratory data, a simple modification to previous computational methods is proposed, based on the area ratio. This new method collapses the available drag data onto an approximately universal curve, and the resulting errors in the computed fall speeds relative to the tank data are less than 25% in all cases. Comparison with the (much more scattered) measurements of ice particles falling in air show strong support for this new method, with the area ratio bias apparently eliminated.
Resumo:
We investigate the spatial characteristics of urban-like canopy flow by applying particle image velocimetry (PIV) to atmospheric turbulence. The study site was a Comprehensive Outdoor Scale MOdel (COSMO) experiment for urban climate in Japan. The PIV system captured the two-dimensional flow field within the canopy layer continuously for an hour with a sampling frequency of 30 Hz, thereby providing reliable outdoor turbulence statistics. PIV measurements in a wind-tunnel facility using similar roughness geometry, but with a lower sampling frequency of 4 Hz, were also done for comparison. The turbulent momentum flux from COSMO, and the wind tunnel showed similar values and distributions when scaled using friction velocity. Some different characteristics between outdoor and indoor flow fields were mainly caused by the larger fluctuations in wind direction for the atmospheric turbulence. The focus of the analysis is on a variety of instantaneous turbulent flow structures. One remarkable flow structure is termed 'flushing', that is, a large-scale upward motion prevailing across the whole vertical cross-section of a building gap. This is observed intermittently, whereby tracer particles are flushed vertically out from the canopy layer. Flushing phenomena are also observed in the wind tunnel where there is neither thermal stratification nor outer-layer turbulence. It is suggested that flushing phenomena are correlated with the passing of large-scale low-momentum regions above the canopy.
Resumo:
As part of the DAPPLE programme two large scale urban tracer experiments using multiple simultaneous releases of cyclic perfluoroalkanes from fixed location point sources was performed. The receptor concentrations along with relevant meteorological parameters measured are compared with a three screening dispersion models in order to best predict the decay of pollution sources with respect to distance. It is shown here that the simple dispersion models tested here can provide a reasonable upper bound estimate of the maximum concentrations measured with an empirical model derived from field observations and wind tunnel studies providing the best estimate. An indoor receptor was also used to assess indoor concentrations and their pertinence to commonly used evacuation procedures.
Resumo:
The physical and empirical relationships used by microphysics schemes to control the rate at which vapor is transferred to ice crystals growing in supercooled clouds are compared with laboratory data to evaluate the realism of various model formulations. Ice crystal growth rates predicted from capacitance theory are compared with measurements from three independent laboratory studies. When the growth is diffusion- limited, the predicted growth rates are consistent with the measured values to within about 20% in 14 of the experiments analyzed, over the temperature range −2.5° to −22°C. Only two experiments showed significant disagreement with theory (growth rate overestimated by about 30%–40% at −3.7° and −10.6°C). Growth predictions using various ventilation factor parameterizations were also calculated and compared with supercooled wind tunnel data. It was found that neither of the standard parameterizations used for ventilation adequately described both needle and dendrite growth; however, by choosing habit-specific ventilation factors from previous numerical work it was possible to match the experimental data in both regimes. The relationships between crystal mass, capacitance, and fall velocity were investigated based on the laboratory data. It was found that for a given crystal size the capacitance was significantly overestimated by two of the microphysics schemes considered here, yet for a given crystal mass the growth rate was underestimated by those same schemes because of unrealistic mass/size assumptions. The fall speed for a given capacitance (controlling the residence time of a crystal in the supercooled layer relative to its effectiveness as a vapor sink, and the relative importance of ventilation effects) was found to be overpredicted by all the schemes in which fallout is permitted, implying that the modeled crystals reside for too short a time within the cloud layer and that the parameterized ventilation effect is too strong.
Resumo:
Following a malicious or accidental atmospheric release in an outdoor environment it is essential for first responders to ensure safety by identifying areas where human life may be in danger. For this to happen quickly, reliable information is needed on the source strength and location, and the type of chemical agent released. We present here an inverse modelling technique that estimates the source strength and location of such a release, together with the uncertainty in those estimates, using a limited number of measurements of concentration from a network of chemical sensors considering a single, steady, ground-level source. The technique is evaluated using data from a set of dispersion experiments conducted in a meteorological wind tunnel, where simultaneous measurements of concentration time series were obtained in the plume from a ground-level point-source emission of a passive tracer. In particular, we analyze the response to the number of sensors deployed and their arrangement, and to sampling and model errors. We find that the inverse algorithm can generate acceptable estimates of the source characteristics with as few as four sensors, providing these are well-placed and that the sampling error is controlled. Configurations with at least three sensors in a profile across the plume were found to be superior to other arrangements examined. Analysis of the influence of sampling error due to the use of short averaging times showed that the uncertainty in the source estimates grew as the sampling time decreased. This demonstrated that averaging times greater than about 5min (full scale time) lead to acceptable accuracy.