995 resultados para Statistical Concepts


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To evaluate the prevalence of acute coronary syndrome (ACS) in patients presenting initially with atypical chest pain and suspected to have pulmonary embolism (PE) or acute aortic syndromes (AAS). To evaluate the overlap between ACS, PE and AAS in routine practice and determine how many patients could have benefit from a single CT protocol to rule out ACS at the same time as PE and AAS. METHOD AND MATERIALS Our electronic hospital database revealed 1122 consecutive patients who underwent a thoracic CT angiography for PE or AAS from 2004 to 2006 (mean age, 63±13 years). Patients without chest pain were excluded from this study. Thus, 447 patients presented with isolated atypical chest were included in the analysis. All patients who underwent a thoracic CT scan previously received standard clinical care and were initially considered as non ACS. The final diagnosis was obtained by the hospital stay report. RESULTS Among the 447 patients with atypical chest pain, 25 (5.5%) were finally found to have ACS: 19 patients (4.2%) were suspected for PE and 6 (1. 3%) were suspected for AAS. There were 90 patients diagnosed to have PE, 89 (98.8%) of them were suspected for PE while only 1 (1%) was suspected for AAS. Eleven patients diagnosed to have AAS, 9 (82%) of them were suspected for AAS while 2 (18%) were suspected for PE. CONCLUSION In clinical practice, the overlap between PE, AAS and ACS is limited which make the triple rule-out studies less recommended to be done at the time being because of the high dose radiation. A double rule-out investigation is suggested to be done for patients being evaluated for atypical chest pain and suspected of having AAS or PE because of a significant overlap between the two entities as well it doesn't implicate any increment in radiation dose. CLINICAL RELEVANCE/APPLICATION With 64-slice CT, coronary circulation and total chest can be evaluated at the same time offering new opportunitie for the evaluation of three major life-threatening conditions :ACS,PE and AAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We here summarize five articles bringing new advances in our knowledge on neuropathic pain and put them into perspective with our current understanding. The first uses a mechanism-based approach with a capsaicin test to stratify patients suffering from painful diabetic neuropathy before starting a topical clonidine treatment. The second reviews disinhibition as a critical mechanism and a promising target for chronic pain. The third evokes neuroglial interactions and its implication regarding the interplay between injuries in childhood and hypersensitivity in adulthood. The last articles remind us that interventional therapies, not always very invasive, have a future potential in the therapy of frequent conditions such as head pain disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a previously-developed, statistical-based, damage-detection approach was validated for its ability to autonomously detect damage in bridges. The damage-detection approach uses statistical differences in the actual and predicted behavior of the bridge caused under a subset of ambient trucks. The predicted behavior is derived from a statistics-based model trained with field data from the undamaged bridge (not a finite element model). The differences between actual and predicted responses, called residuals, are then used to construct control charts, which compare undamaged and damaged structure data. Validation of the damage-detection approach was achieved by using sacrificial specimens that were mounted to the bridge and exposed to ambient traffic loads and which simulated actual damage-sensitive locations. Different damage types and levels were introduced to the sacrificial specimens to study the sensitivity and applicability. The damage-detection algorithm was able to identify damage, but it also had a high false-positive rate. An evaluation of the sub-components of the damage-detection methodology and methods was completed for the purpose of improving the approach. Several of the underlying assumptions within the algorithm were being violated, which was the source of the false-positives. Furthermore, the lack of an automatic evaluation process was thought to potentially be an impediment to widespread use. Recommendations for the improvement of the methodology were developed and preliminarily evaluated. These recommendations are believed to improve the efficacy of the damage-detection approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Juvenile Court Services Offices are issuing their fourth annual statewide report. The the Iowa Division of Criminal and Juvenile Justice Planning (CJJP). This report would not be possible without the dedication of, and assistance from, all of the above-mentioned people. The eight Chief Juvenile Court Officers would like to take this opportunity to thank their staff for their dedication and their ability to enter accurate information on every youth referred to Juvenile Court Services; the staff at the Iowa Court Information System, without whom this report would not be possible; and CJJP for their maintenance of the Iowa Justice Data Warehouse and their support in preparing this document.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Juvenile Court Services Offices are issuing their fourth annual statewide report. The the Iowa Division of Criminal and Juvenile Justice Planning (CJJP). This report would not be possible without the dedication of, and assistance from, all of the above-mentioned people. The eight Chief Juvenile Court Officers would like to take this opportunity to thank their staff for their dedication and their ability to enter accurate information on every youth referred to Juvenile Court Services; the staff at the Iowa Court Information System, without whom this report would not be possible; and CJJP for their maintenance of the Iowa Justice Data Warehouse and their support in preparing this document.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A-1 - Monthly Public Assistance Statistical Report Family Investment Program