952 resultados para Secondary wastewater treatment
Resumo:
Rwanda is a landlocked country located in Africa's Central-East Great Lakes region. It has a population of 7.5 million which occupies 26,338 km'. Its population density (285/km') is one of the highest in the world and has prompted fear of a rapid degradation of the ecosystem. There are no central sewer systems in Rwanda. The use of pit latrines and septic tanks is common in urban and rural areas. People still defecate in the fields (World Bank, 1989). Less than half of the urban population is served by a central water supply. The majority of people get their water untreated from rivers that have been polluted by chemicals and human excreta. In and around the capital city of Kigali, there is a concentration of people, farms, and industries which discharge wastewater into the Nyabarongo River and its tributaries. The Nyabarongo River, a tributary of the Nile, empties into the Akagera River which flows into Lake Victoria. Nyabarongo River water is used for drinking water, cooking, bathing, and agriculture in the Kigali area. There has been very little monitoring of the water quality of the Nyabarongo River and of industrial outfalls located on tributaries of the Nyabarongo River. As a first step in understanding the water quality of the Nyabarongo River, wastewater samples were collected in 1993 from industrial outfalls located on tributaries of the Nyabarongo River. Most of the facilities sampled had no wastewater treatment. The impact of these discharges on the water quality of the Nyabarongo River was evaluated.
Resumo:
A comprehensive method for the analysis of 11 target pharmaceuticals representing multiple therapeutic classes was developed for biological tissues (fish) and water. Water samples were extracted using solid phase extraction (SPE), while fish tissue homogenates were extracted using accelerated solvent extraction (ASE) followed by mixed-mode cation exchange SPE cleanup and analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Among the 11 target pharmaceuticals analyzed, trimethoprim, caffeine, sulfamethoxazole, diphenhydramine, diltiazem, carbamazepine, erythromycin and fluoxetine were consistently detected in reclaimed water. On the other hand, caffeine, diphenhydramine and carbamazepine were consistently detected in fish and surface water samples. In order to understand the uptake and depuration of pharmaceuticals as well as bioconcentration factors (BCFs) under the worst-case conditions, mosquito fish were exposed to reclaimed water under static-renewal for 7 days, followed by a 14-day depuration phase in clean water. Characterization of the exposure media revealed the presence of 26 pharmaceuticals while 5 pharmaceuticals including caffeine, diphenhydramine, diltiazem, carbamazepine, and ibuprofen were present in the organisms as early as 5 h from the start of the exposure. Liquid chromatography ultra-high resolution Orbitrap mass spectrometry was explored as a tool to identify and quantify phase II pharmaceutical metabolites in reclaimed water. The resulting data confirmed the presence of acetyl-sulfamethoxazole and sulfamethoxazole glucuronide in reclaimed water. To my knowledge, this is the first known report of sulfamethoxazole glucuronide surviving intact through wastewater treatment plants and occurring in environmental water samples. Finally, five bioaccumulative pharmaceuticals including caffeine, carbamazepine, diltiazem, diphenhydramine and ibuprofen detected in reclaimed water were investigated regarding the acute and chronic risks to aquatic organisms. The results indicated a low potential risk of carbamazepine even under the worst case exposure scenario. Given the dilution factors that affect environmental releases, the risk of exposure to carbamazepine will be even more reduced.
Resumo:
An automated on-line SPE-LC-MS/MS method was developed for the quantitation of multiple classes of antibiotics in environmental waters. High sensitivity in the low ng/L range was accomplished by using large volume injections with 10-mL of sample. Positive confirmation of analytes was achieved using two selected reaction monitoring (SRM) transitions per antibiotic and quantitation was performed using an internal standard approach. Samples were extracted using online solid phase extraction, then using column switching technique; extracted samples were immediately passed through liquid chromatography and analyzed by tandem mass spectrometry. The total run time per each sample was 20 min. The statistically calculated method detection limits for various environmental samples were between 1.2 and 63 ng/L. Furthermore, the method was validated in terms of precision, accuracy and linearity. ^ The developed analytical methodology was used to measure the occurrence of antibiotics in reclaimed waters (n=56), surface waters (n=53), ground waters (n=8) and drinking waters (n=54) collected from different parts of South Florida. In reclaimed waters, the most frequently detected antibiotics were nalidixic acid, erythromycin, clarithromycin, azithromycin trimethoprim, sulfamethoxazole and ofloxacin (19.3-604.9 ng/L). Detection of antibiotics in reclaimed waters indicates that they can't be completely removed by conventional wastewater treatment process. Furthermore, the average mass loads of antibiotics released into the local environment through reclaimed water were estimated as 0.248 Kg/day. Among the surface waters samples, Miami River (reaching up to 580 ng/L) and Black Creek canal (up to 124 ng/L) showed highest concentrations of antibiotics. No traces of antibiotics were found in ground waters. On the other hand, erythromycin (monitored as anhydro erythromycin) was detected in 82% of the drinking water samples (n.d-66 ng/L). The developed approach is suitable for both research and monitoring applications.^ Major metabolites of antibiotics in reclaimed wates were identified and quantified using high resolution benchtop Q-Exactive orbitrap mass spectrometer. A phase I metabolite of erythromycin was tentatively identified in full scan based on accurate mass measurement. Using extracted ion chromatogram (XIC), high resolution data-dependent MS/MS spectra and metabolic profiling software the metabolite was identified as desmethyl anhydro erythromycin with molecular formula C36H63NO12 and m/z 702.4423. The molar concentration of the metabolite to erythromycin was in the order of 13 %. To my knowledge, this is the first known report on this metabolite in reclaimed water. Another compound acetyl-sulfamethoxazole, a phase II metabolite of sulfamethoxazole was also identified in reclaimed water and mole fraction of the metabolite represent 36 %, of the cumulative sulfamethoxazole concentration. The results were illustrating the importance to include metabolites also in the routine analysis to obtain a mass balance for better understanding of the occurrence, fate and distribution of antibiotics in the environment. ^ Finally, all the antibiotics detected in reclaimed and surface waters were investigated to assess the potential risk to the aquatic organisms. The surface water antibiotic concentrations that represented the real time exposure conditions revealed that the macrolide antibiotics, erythromycin, clarithromycin and tylosin along with quinolone antibiotic, ciprofloxacin were suspected to induce high toxicity to aquatic biota. Preliminary results showing that, among the antibiotic groups tested, macrolides posed the highest ecological threat, and therefore, they may need to be further evaluated with, long-term exposure studies considering bioaccumulation factors and more number of species selected. Overall, the occurrence of antibiotics in aquatic environment is posing an ecological health concern.^
Resumo:
Siloxanes are widely used in personal care and industrial products due to their low surface tension, thermal stability, antimicrobial and hydrophobic properties, among other characteristics. Volatile methyl siloxanes (VMS) have been detected both in landfill gas and biogas from anaerobic digesters at wastewater treatment plants. As a result, they are released to gas phase during waste decomposition and wastewater treatment. During transformation processes of digester or landfill gas to energy, siloxanes are converted to silicon oxides, leaving abrasive deposits on engine components. These deposits cause increased maintenance costs and in some cases complete engine overhauls become necessary. The objectives of this study were to compare the VMS types and levels present in biogas generated in the anaerobic digesters and landfills and evaluate the energetics of siloxane transformations under anaerobic conditions. Siloxane emissions, resulting from disposal of silicone-based materials, are expected to increase by 29% within the next 10 years. Estimated concentrations and the risk factors of exposure to siloxanes were evaluated based on the initial concentrations, partitioning characteristics and persistence. It was determined that D4 has the highest risk factor associated to bioaccumulation in liquid and solid phase, whereas D5 was highest in gas phase. Additionally, as siloxanes are combusted, the particle size range causes them to be potentially hazardous to human health. When inhaled, they may affix onto the alveoli of the lungs and may lead to development of silicosis. Siloxane-based COD-loading was evaluated and determined to be an insignificant factor concerning COD limits in wastewater. Removal of siloxane compounds is recommended prior to land application of biosolids or combustion of biogas. A comparison of estimated costs was made between maintenance practices for removal of siloxane deposits and installation/operation of fixed-bed carbon absorption systems. In the majority of cases, the installation of fixed-bed adsorption systems would not be a feasible option for the sole purpose of siloxane removal. However they may be utilized to remove additional compounds simultaneously.
Resumo:
The principal effluent in the oil industry is the produced water, which is commonly associated to the produced oil. It presents a pronounced volume of production and it can be reflected on the environment and society, if its discharge is unappropriated. Therefore, it is indispensable a valuable careful to establish and maintain its management. The traditional treatment of produced water, usualy includes both tecniques, flocculation and flotation. At flocculation processes, there are traditional floculant agents that aren’t well specified by tecnichal information tables and still expensive. As for the flotation process, it’s the step in which is possible to separate the suspended particles in the effluent. The dissolved air flotation (DAF) is a technique that has been consolidating economically and environmentally, presenting great reliability when compared with other processes. The DAF is presented as a process widely used in various fields of water and wastewater treatment around the globe. In this regard, this study was aimed to evaluate the potential of an alternative natural flocculant agent based on Moringa oleifera to reduce the amount of oil and grease (TOG) in produced water from the oil industry by the method of flocculation/DAF. the natural flocculant agent was evaluated by its efficacy, as well as its efficiency when compared with two commercial flocculant agents normally used by the petroleum industry. The experiments were conducted following an experimental design and the overall efficiencies for all flocculants were treated through statistical calculation based on the use of STATISTICA software version 10.0. Therefore, contour surfaces were obtained from the experimental design and were interpreted in terms of the response variable removal efficiency TOG (total oil and greases). The plan still allowed to obtain mathematical models for calculating the response variable in the studied conditions. Commercial flocculants showed similar behavior, with an average overall efficiency of 90% for oil removal, however it is the economical analysis the decisive factor to choose one of these flocculant agents to the process. The natural alternative flocculant agent based on Moringa oleifera showed lower separation efficiency than those of commercials one (average 70%), on the other hand this flocculant causes less environmental impacts and it´s less expensive
Resumo:
In this work the degradation of real and synthetic wastewater was studied using electrochemical processes such as oxidation via hydroxyl radicals, mediated oxidation via active chlorine and electrocoagulation. The real effluent used was collected in the decanter tank of the Federal University of Rio Grande do Norte (ETE-UFRN) of Effluent Treatment Plant and the other a textile effluent dye Ácido Blue 113 (AB 113) was synthesized in the laboratory. In the electrochemical process, the effects of anode material, current density, the presence and concentration of chloride as well as the active chlorine species on site generated were evaluated. Electrodes of different compositions, Ti/Pt, Ti/Ru0,3Ti0,7O2, BDD, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 were used as anodes. These electrodes were subjected to electroanalytical analysis with the goal of checking how happen the anodic and cathodic processes across the concentrations of NaCl and supporting electrolyte used. The potential of oxygen evolution reaction were also checked. The effect of active chlorine species formed under the process efficiency was evaluated by removing the organic matter in the effluent-ETE UFRN. The wastewater treatment ETE-UFRN using Ti/Pt, DDB and Ti/Ru0,3Ti0,7O2 electrodes was evaluated, obtaining good performances. The electrochemical degradation of effluent-UFRN was able to promote the reduction of the concentration of TOC and COD in all tested anodes. However, Ti/Ru0,3Ti0,7O2 showed a considerable degradation due to active chlorine species generated on site. The results obtained from the electrochemical process in the presence of chloride were more satisfactory than those obtained in the absence. The addition of 0.021 M NaCl resulted in a faster removal of organic matter. Secondly, was prepared and characterized the electrode Ti/TiO2-nanotubes/PbO2 according to what the literature reports, however their preparation was to disk (10 cm diameter) with surface area and higher than that described by the same authors, aiming at application to textile effluent AB 113 dye. SEM images were taken to observe the growth of TiO2 nanotubes and confirm the electrodeposition of PbO2. Atomic Force Microscope was also used to confirm the formation of these nanotubes. Furthermore, was tested and found a high electrochemical stability of the electrode Ti/TiO2-nanotubes/PbO2 for applications such as long-term indicating a good electrocatalytic material. The electrochemical oxidation of AB 113 using Ti/Pt, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 and Al/Al (electrocoagulation) was also studied. However, the best color removal and COD decay were obtained when Ti/TiO2-nanotubes/PbO2 was used as the anode, removing up to 98% of color and 92,5% of COD decay. Analysis of GC/MS were performed in order to identify possible intermediates formed in the degradation of AB 113.
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
Volos city and its port are situated in the northern part of Pagassitikos Gulf, a shallow, semi-enclosed marine area in central Greece. A wastewater treatment plant (WWTP) and pipeline operate in the same area. Muddy sediments with low carbonate contents cover most of the seabed, except for the Volos embayment and the western part of the gulf where sandy carbonates prevail. Bulk organic carbon contents and the organic carbon contents of the clay fractions are high in the vicinity of Volos embayment. High element (Pb, Cu, and Zn) contents and Igeo (geoaccumulation index) values were found for the clay fractions in the northern part of Pagassitikos Gulf. This enrichment is attributed to the discharge of raw domestic and industrial effluents of Volos city and port before the WWTP was installed. The dispersal of pollutants is essentially controlled by diffusion from point sources (city, port and WWTP) and is limited to Volos Bay. Relatively high Mn levels are ascribed to diagenetic formation of manganese carbonates (authigenic phase), whereas Cr and Ni are elevated due to weathering of ultrabasic formations on land.
Resumo:
The new engine plant by General Motors (GM) in Joinville-SC, inaugurated on February 27th 2013, incorporates the most advanced automotive technology processes and broad compliance with environmental standards and energy efficiency. The initiatives implemented in this industrial plant include processes with 100% of recycled industrial waste (landfill free) and pioneer systems in energy efficiency and environmental protection, qualifying the plant to obtain the global certification of Leadership in Energy and Environmental Design (LEED). This industrial project reveals the strategic importance of the region and of Brazil in the growth of GM in the world, becoming a reference for studies and project evaluations of "green" factories in the automotive sector. The present study performs an exploratory research based on scientific publications, assessing the direct and indirect impacts on the business outcome, resulting from implementation of industrial serviceoriented sustainability of its operations, referred to in this article as "Green Factory”. We concluded that the adopted technologies focused on sustainability, study and development, represent a new step for the design of new plants and future expansions of the company in the region, combining low operating cost, low environmental impact and conservation of natural resources.
Resumo:
O compromisso das organizações com as obrigações decretadas ao nível do ambiente, segurança e qualidade emancipa a implementação de Sistemas de Gestão e o processo de auditar. Neste trabalho, decorrente do estágio curricular no âmbito do Mestrado em Engenharia do Ambiente, está evidenciada a importância dos Sistemas de Gestão Ambiental e as razões preponderantes para que sejam auditados. O trabalho pretendeu auditar e avaliar a conformidade do sistema de gestão ambiental, de acordo com a NP EN ISO 14001:2004, de uma indústria de fundição de metais, Funfrap -. Fundição Portuguesa SA, a fim de identificar oportunidades de melhoria no desempenho ambiental da organização. No âmbito do estágio foram ainda realizadas outras atividades, incluindo campanhas de sensibilização, inventário de resíduos sólidos, ferramentas da metodologia World Class Manufacturing, formação sobre a separação de resíduos nos postos de trabalho, acompanhamento de um ensaio na estação de tratamento de águas residuais industriais e apoio para o desenvolvimento do relatório ambiental anual. Da auditoria interna identificaram-se e corrigiram-se nove não conformidades menores e cinco observações. Da auditoria externa foram identificadas apenas duas não conformidades, nenhuma delas relacionadas com as detetadas anteriormente. Além deste resultado foram sugeridas algumas medidas para alcançar um melhor desempenho ambiental da organização.
Resumo:
Objectives: Mycological contamination of occupational environments can be a result of fungal spores’ dispersion in the air and on surfaces. Therefore, it is very important to assess it in both types of the samples. In the present study we assessed fungal contamination in the air and in the surface samples to show relevance of surfaces sampling in complementing the results obtained in the air samples. Material and Methods: In total, 42 settings were assessed by the analysis of air and surfaces samples. The settings were divided into settings with a high fungal load (7 poultry farms and 7 pig farms, 3 cork industries, 3 waste management plants, 2 wastewater treatment plants and 1 horse stable) and a low fungal load (10 hospital canteens, 8 college canteens and 1 maternity hospital). In addition to culture-based methods, molecular tools were also applied to detect fungal burden in the settings with a higher fungal load. Results: From the 218 sampling sites, 140 (64.2%) presented different species in the examined surfaces when compared with the species identified in the air. A positive association in the high fungal load settings was found between the presence of different species in the air and surfaces. Wastewater treatment plants constituted the setting with the highest number of different species between the air and surface. Conclusions: We observed that surfaces sampling and application of molecular tools showed the same efficacy of species detection in high fungal load settings, corroborating the fact that surface sampling is crucial for a correct and complete analysis of occupational scenarios.
Resumo:
Lääkeaineiden poistaminen jätevedestä on tärkeää lääkeainejäämien ympäristöön pääsyn ehkäisemiseksi. Tämän työn tavoitteena on selvittää, soveltuvatko katalyyttiset membraanit lääkeaineiden poistoon jätevedestä ja saadaanko membraanisuodatusta tehostettua katalyyttisellä prosessilla. Työ käsittelee katalyyttisistä prosesseista fotokatalyysiä, joka perustuu valoa absorboivan katalyytin käyttöön. Kirjallisuustyössä tarkastellaan kahden erilaisen fotokatalyyttisen prosessin toimivuutta membraanisuodatuksen kanssa lääkeaineiden poistossa jätevedestä. Lisäksi tutkitaan fotokatalyysissä käytettävän katalyytin ja ultraviolettisäteilyn vaikutusta membraaniin. Tutkimukset ovat osoittaneet, että katalyyttisillä membraaneilla voidaan poistaa lääkeaineita jätevedestä tehokkaasti. Parhaan lääkeaineiden poistotehokkuuden saamiseksi katalyytin määrä on optimoitava hajotusprosessin kannalta. Myös katalyytin sijainti membraanissa vaikuttaa tehokkuuteen. Katalyytti voi sijaita membraanista myös erillään. Tällöin saadaan käsiteltyä myös jatkuvatoimisessa membraanisuodatuksessa syntyvä lääkeaineita sisältävä konsentraattivirta. Kun katalyyttisellä membraanilla hajotetaan lääkeaineita, täytyy prosessin turvallisuuden kannalta olla hyvin selvillä mahdollisista syntyvistä myrkyllisistä välituotteista. Tutkimuksissa on myös todettu, että katalyyttisen membraanin käyttö vähentää membraanin likaantumista.
Resumo:
En este trabajo se presenta la descripción e investigación en la evaluación de vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum) en el diseño de humedales artificiales. Para el tratamiento de aguas residuales de origen doméstico, siendo la vegetación uno de los principales componentes de estos sistemas de tratamientos no convencionales. Muchos \sistemas naturales" están siendo considerados con el propósito del tratamiento del agua residual y control de la contaminación del agua, debido a su alta fiabilidad ambiental y los bajos costos de construcción y mantenimiento, es el caso de los humedales artificiales. El interés en los sistemas naturales está basado en la conservación de los recursos asociados con estos sistemas como opuesto al proceso de tratamiento convencional de aguas residuales que es intensivo respecto al uso de energía y químicos. Los wetlands o humedales artificiales constituyen una alternativa de tratamiento debido a su alta eficiencia de remoción de contaminantes, a su bajo costo de instalación y mantenimiento y a su alta fiabilidad ambiental, generalmente un humedal artificial esta constituido por un medio de soporte el cual generalmente es arena o grava, vegetación y microorganismos o biopelícula los cuales llevan los diferentes procesos bioquímicos para remover los contaminantes del afluente. El objetivo general de este trabajo ha sido: Evaluar la eficiencia de remoción de materia orgánica, sólidos, nitrógeno y fósforo total de dos especies de plantas: vetiver (Chrysopogon zizanioides) y la elefanta (Pennisetum purpureum), en el diseño de humedales artificiales para el tratamiento de aguas residuales de origen doméstico. Los humedales artificiales o sistemas pilotos, se encuentran ubicados en la universidad de Medellín y reciben una preparación de agua sintética, que asemeja a las características de un agua residual de origen doméstico. En el presente trabajo se evalúa el porcentaje de remoción de la carga orgánica de aguas residuales, en un sistema de tratamiento por humedales artificiales con dos especies vegetales. El sistema fue diseñado con tres módulos instalados de manera adjunta. En el primero no se integra ninguna especie vegetal, solo el medio de sustrato el cual constituye el blanco (-), en el segundo se integraron organismos de la especie vetiver (Chrysopogon zizanioides), en el tercer sistema piloto, organismos de la especie elefanta (Pennisetum purpureum) y en el cuarto organismos de la especie papiro japones (Cyperus alternifolius), los cuales constituyen el control positivo (+). Los módulos experimentales fueron limpiados, cortados y adecuados acorde al montaje inicial de las plantas y al espacio requerido para su disposición. A cada sistema piloto se le agrega medio de soporte constituido por grava (5 a 10 cm) y arena (15 a 20 cm), el sustrato es evaluado y caracterizado por su diámetro nominal, posterior en cada sistema se siembran las especies en un área de 3x3 y cada humedal por dos semanas se adecua bajo la solución de Hoagland y Arnon y régimen de humedad. En el agua sintética se analizaron los siguientes parámetros: pH, sólidos totales, sólidos suspendido totales, sólidos disueltos totales, demanda química de oxígeno (DQO), demanda bioquímica de oxígeno (DBO5), nitrógeno total (NTK) y fosforo total (PT). También se realizó la determinación del crecimiento de las plantas a partir del incremento de biomasa, porosidad de la raíz y de igual forma se determina NTK y PT. Los resultados demostraron que el sistema es una opción para la remoción de la carga orgánica y de nutrientes en aguas residuales de origen doméstico, de bajo costo de operación y mantenimiento, especialmente se observa que las plantas que crecen en sistemas de régimen de humedad ácuico y ústico, tienden a tener una mayor recepción y adaptación en los humedales artificiales pilotos, es el caso de la elefanta (Pennisetum purpureum), el cual presenta las más altas tasas de remoción de contaminantes y nutrientes en el afluente, seguido por el papiro japonés (Cyperus alternifolius) y el vetiver (Chrysopogon zizanioides), respecto a tasas de remoción. La remoción de contaminantes que se presentan más altos respectivamente, constituyen sólidos en primera instancia, seguido por la demanda bioquímica de oxigeno (DBO5), demanda química de oxígeno (DQO), nitrógeno total (NTK) y fósforo total (PT), estos últimos presentan una baja tasa de remoción, debido a la naturaleza misma del contaminante, a los organismos que realizan la remoción y absorción y al tiempo de retención que se elige, el cual influye en la tasa de remoción del contaminante siendo menor en la concentración de fósforo, pero se encuentranen el rango esperado para estos sistemas de tratamiento no convencionales.
Resumo:
Com a realização deste trabalho, pretendeu-se efetuar uma seleção de culturas mistas em reatores semi-descontínuos (SBR) com capacidade de acumulação de polihidroxialcanoatos (PHA). Para a seleção de culturas foram utilizados inóculos provenientes de diferentes Estações de Tratamento de Águas Residuais (ETAR) e ácidos orgânicos voláteis (AOV) como fonte de carbono. Foram testadas diferentes condições como a proveniência do inóculo, as cargas orgânicas aplicadas e a seleção de culturas utilizando soro de queijo. Verificaram-se elevadas remoções da CQO (acima de 90%) em grande parte dos ensaios realizados, apresentando uma acumulação de PHA por parte de algumas espécies de bactérias presentes. Ocorreu o aparecimento de microrganismos filamentosos com capacidade de acumulação de PHA em alguns ensaios, levando a serem testadas como culturas acumuladoras de PHA. A estabilidade das culturas mistas não foi atingida, mesmo havendo ensaios com 80 dias de operação. Efetuaram-se ensaios de acumulação de PHA em reatores descontínuos, utilizando as culturas selecionadas anteriormente em reatores SBR, com AOV provenientes da acidificação anaeróbia de diferentes resíduos (Fração Orgânica dos Resíduos Sólidos Urbanos - FORSU e Soro de Queijo). Verificou-se uma melhor acumulação por parte das culturas selecionadas com soro de queijo, na qual a quantidade de polímero acumulado triplicou.