Dentinal cracks are occasionally observed at the cut root face after root-end resection in apical surgery. The objective of this ex vivo study was to evaluate and compare the efficiency of visual aids to identify root-end dentinal cracks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solutions containing tin and fluoride exhibit remarkable anti-erosive properties with tin ions as a major agent. To elucidate its mechanism of action in dentine, the tin uptake on and in the tissue was investigated and related to histological findings and substance loss. Samples were treated twice daily, each treatment lasting for 2 min, with fluoride solutions [pH 4.5; 1,500 parts per million (p.p.m.) F] containing 2,100, 1,400, or 400 p.p.m. Sn as SnCl(2). In experiments 1 and 2, samples were eroded with citric acid (pH 2.3) six times each day, each treatment lasting for 5 min; in experiment 2, the demineralized organic matrix was continuously digested by collagenase; in experiment 3, no erosive challenges were performed. Sample surfaces and cross-sections were investigated using energy dispersive X-ray spectroscopy, scanning electron microscopy, and profilometry. Surface retention of tin was found in almost all treatment groups and was highest in experiment 2. On cross-sections, tin was retained within the organic matrix; in mineralized areas, tin was found mainly within a depth of 10 mum. Test solutions inhibited substance loss significantly; in experiment 2, the effect was dose-dependent. Erosion inhibition seemed to depend mainly on the incorporation of tin in the mineralized dentine when the organic portion was preserved, but on surface precipitation when the organic portion was continuously digested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A laser scanning microscope collects information from a thin, focal plane and ignores out of focus information. During the past few years it has become the standard imaging method to characterise cellular morphology and structures in static as well as in living samples. Laser scanning microscopy combined with digital image restoration is an excellent tool for analysing the cellular cytoarchitecture, expression of specific proteins and interactions of various cell types, thus defining valid criteria for the optimisation of cell culture models. We have used this tool to establish and evaluate a three dimensional model of the human epithelial airway wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on coherent spatiotemporal imaging of single-cycle THz waves in frustrated total internal reflection geometry. Our technique yields images of the spatiotemporal electric field distribution before and after tunneling through an air gap in between two LiNbO3 crystals. Measurements of the reflected and the transmitted THz waveforms for different tunnel distances allow for a direct comparison with results from a causal linear dispersion theory and excellent agreement is found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four experiments examined how people operate on memory representations of familiar songs. The tasks were similar to those used in studies of visual imagery. In one task, subjects saw a one word lyric from a song and then saw a second lyric; then they had to say if the second lyric was from the same song as the first. In a second task, subjects mentally compared pitches of notes corresponding to song lyrics. In both tasks, reaction time increased as a function of the distance in beats between the two lyrics in the actual song, and in some conditions reaction time increased with the starting beat of the earlier lyric. Imagery instructions modified the main results somewhat in the first task, but not in the second, much harder task. The results suggest that song representations have temporal-like characteristics. (PsycINFO Database Record (c) 2012 APA, all rights reserved)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bite mark analysis offers the opportunity to identify the biter based on the individual characteristics of the dentitions. Normally, the main focus is on analysing bite mark injuries on human bodies, but also, bite marks in food may play an important role in the forensic investigation of a crime. This study presents a comparison of simulated bite marks in different kinds of food with the dentitions of the presumed biter. Bite marks were produced by six adults in slices of buttered bread, apples, different kinds of Swiss chocolate and Swiss cheese. The time-lapse influence of the bite mark in food, under room temperature conditions, was also examined. For the documentation of the bite marks and the dentitions of the biters, 3D optical surface scanning technology was used. The comparison was performed using two different software packages: the ATOS modelling and analysing software and the 3D studio max animation software. The ATOS software enables an automatic computation of the deviation between the two meshes. In the present study, the bite marks and the dentitions were compared, as well as the meshes of each bite mark which were recorded in the different stages of time lapse. In the 3D studio max software, the act of biting was animated to compare the dentitions with the bite mark. The examined food recorded the individual characteristics of the dentitions very well. In all cases, the biter could be identified, and the dentitions of the other presumed biters could be excluded. The influence of the time lapse on the food depends on the kind of food and is shown on the diagrams. However, the identification of the biter could still be performed after a period of time, based on the recorded individual characteristics of the dentitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As revealed for the first time by in situ scanning tunnelling spectroscopy (STS), ferrocene-modified Si(111) substrates show ambipolar field effect transistor (FET) behaviour upon electrolyte gating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated structural aspects of electron transfer (ET) in tunneling junctions (Au(1 1 1)vertical bar FcN vertical bar solution gap vertical bar Au STM tip) with four different redox-active N-thioalk(ano)ylferrocenes (FcN) embedded. The investigated molecules consist of a redox-active ferrocene (Fc) moiety connected via alkyl spacers with N = 4, 6, 8 and 11 carbon atoms to a thiol anchoring group. We found that for short FcNs (N = 4, 6,8) the redox-mediated ET response increases with the increase of the alkyl chain length, while no enhancement of the ET was observed for Fc1 1. The model of two-step ET with partial vibrational relaxation by Kuznetsov and Ulstrup was used to rationalize these results. The theoretical ET steps were assigned to two processes: (1) electron tunneling from the Fc group to the Au tip through the electrolyte layer and (2) electron transport from the Au(1 1 1) substrate to the Fc group through the organic adlayer. We argue that for the three short FcNs, the first process represents the rate-limiting step. The increase of the length of the alkyl chain leads to an approach of the Fc group to the STM tip, and consequently accelerates the first El' step. In case of the Fcl 1 junctions the rather high thickness of the organic layer leads to a decrease of the rate of the second ET step. In consequence, the contribution of the redox-mediated current enhancement to the total tunneling current appears to be insignificant. Our work demonstrates the importance of combined structural and transport approaches for the understanding of Er processes in electrochemical nanosystems. (C) 2010 Elsevier B.V. All rights reserved.