837 resultados para Robot Team


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Next to the extensive use of social networking platforms (SNPs) for communication and relationship building with friends and relatives, SNPs are also increasingly used for enhancing collaboration at work. SNP usage at the workplace is fundamentally different and it is unclear how SNPs can improve collaboration as well as in what way their designs should be modified and adapted to collaboration settings. This research identifies specific SNP functions that enhance social presence as particularly beneficial for collaboration. Consequently, two designs of SNPs, one with high social presence and one with low social presence, are outlined and its impacts on collaboration are discussed. A framework is constructed that illustrates how social presence in SNPs can improve team performance through enhancing transactive memory within teams (intra-group collaboration) and relational capital across teams (inter-group collaboration). In addition, it is outlined how this framework could be evaluated in an experimental setting of teams working on a complex group task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Bucknell Humanoid Robot Arm project was developed in order toprovide a lightweight robotic arm for the IHMC / Bucknell University bipedal robot that will provide a means of manipulation and facilitate operations in urban environments. The resulting fabricated arm described in this thesis weighs only 13 pounds, and is capable of holding 11 pounds fully outstretched, lifting objects such as tools, and it can open doors. It is also capable of being easily integrated with the IHMC / Bucknell University biped. This thesis provides an introduction to robots themselves, discusses the goals of the Bucknell Humanoid Robot Arm project, provides a background on some of the existing robots, and shows how the Bucknell Humanoid Robot Arm fits in with the studies that have been completed. After reading these studies, important items such as design trees and operational scenarios were completed. The completion of these items led to measurable specifications and later the design requirements and specifications. A significant contribution of this thesis to the robotics discipline involves the design of the actuator itself. The arm uses of individual, lightweight, compactly designed actuators to achieve desired capabilities and performance requirements. Many iterations were completed to get to the final design of each actuator. After completing the actuators, the design of the intermediate links and brackets was finalized. Completion of the design led to the development of a complex controls system which used a combination of Clanguage and Java.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the early prognostic value of the medical emergency team (MET) calling criteria in patients admitted to intensive care from the emergency department. DESIGN: Retrospective cohort study. SETTING: Emergency department and department of intensive care medicine of a 960-bed tertiary referral hospital. PATIENTS: A total of 452 consecutive adult patients admitted to intensive care from the emergency department from January 1, 2004, to December 31, 2004. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: MET calling criteria were retrospectively extracted from patient records, and the sum of positive criteria was calculated for the first hour in the emergency department (METinitial) and subsequently until admission to the intensive care unit in a series of time periods. The maximum number of positive MET calling criteria during any time period was defined (METmax). Logistic regression analysis revealed METinitial (odds ratio [OR] 3.392, 95% confidence interval [CI] 2.534-4.540) and METmax (OR 3.867, 95% CI 2.816-5.312) to be significant predictors of hospital mortality, the need for mechanical ventilation (METinitial: OR 4.151, 95% CI 3.53-4.652; METmax: OR 4.292, 95% CI 3.151-5.846), and occurrence of hemodynamic instability (METinitial: OR 1.548, 95% CI 1.258-1.905; METmax: OR 1.685, 95% CI 1.355-2.094) (all p < .0001). CONCLUSIONS: MET scores collected early after admission or throughout the stay in the emergency department allow for simple identification of patients at risk of unfavorable outcome during the subsequent intensive care unit stay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During locomotion, turning is a common and recurring event which is largely neglected in the current state-of-the-art ankle-foot prostheses, forcing amputees to use different steering mechanisms for turning, compared to non-amputees. A better understanding of the complexities surrounding lower limb prostheses will lead to increased health and well-being of amputees. The aim of this research is to develop a steerable ankle-foot prosthesis that mimics the human ankle mechanical properties. Experiments were developed to estimate the mechanical impedance of the ankle and the ankles angles during straight walk and step turn. Next, this information was used in the design of a prototype, powered steerable ankle-foot prosthesis with two controllable degrees of freedom. One of the possible approaches in design of the prosthetic robots is to use the human joints’ parameters, especially their impedance. A series of experiments were conducted to estimate the stochastic mechanical impedance of the human ankle when muscles were fully relaxed and co-contracting antagonistically. A rehabilitation robot for the ankle, Anklebot, was employed to provide torque perturbations to the ankle. The experiments were performed in two different configurations, one with relaxed muscles, and one with 10% of maximum voluntary contraction (MVC). Surface electromyography (sEMG) was used to monitor muscle activation levels and these sEMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the lateral/medial (LM) directions, inversion-eversion (IE), and dorsiflexionplantarflexion (DP) were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in all degrees of freedom of the ankle. Another experiment compared the three-dimensional angles of the ankle during step turn and straight walking. These angles were measured to be used for developing the control strategy of the ankle-foot prosthesis. An infrared camera system was used to track the trajectories and angles of the foot and leg. The combined phases of heel strike and loading response, mid stance, and terminal stance and pre-swing were determined and used to measure the average angles at each combined phase. The Range of motion (ROM) in IE increased during turning while ML rotation decreased and DP changed the least. During the turning step, ankle displacement in DP started with similar angles to straight walk and progressively showed less plantarflexion. In IE, the ankle showed increased inversion leaning the body toward the inside of the turn. ML rotation initiated with an increased medial rotation during the step turn relative to the straight walk transitioning to increased lateral rotation at the toe off. A prototype ankle-foot prosthesis capable of controlling both DP and IE using a cable driven mechanism was developed and assessed as part of a feasibility study. The design is capable of reproducing the angles required for straight walk and step turn; generates 712N of lifting force in plantarflexion, and shows passive stiffness comparable to a nonload bearing ankle impedance. To evaluate the performance of the ankle-foot prosthesis, a circular treadmill was developed to mimic human gait during steering. Preliminary results show that the device can appropriately simulate human gait with loading and unloading the ankle joint during the gait in circular paths.