960 resultados para Radiation use efficiency


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In cervical postoperative radiotherapy, the target volume is usually the same as the extension of the previous dissection. We evaluated a protocol of selective irradiation according to the risk estimated for each dissected lymph node level. METHODS Eighty patients with oral/oropharyngeal cancer were included in this prospective clinical study between 2005 and 2008. Patients underwent surgery of the primary tumor and cervical dissection, with identification of positive nodal levels, followed by selective postoperative radiotherapy. Three types of selective nodal clinical target volume (CTV) were defined: CTV0, CTV1, and CTV2, with a subclinical disease risk of <10%, 10-25%, and 25% and a prescribed radiation dose of <35 Gy, 50 Gy, and 66-70 Gy, respectively. The localization of node failure was categorized as field, marginal, or outside the irradiated field. RESULTS A consistent pattern of cervical infiltration was observed in 97% of positive dissections. Lymph node failure occurred within a high-risk irradiated area (CTV1-CTV2) in 12 patients, marginal area (CTV1/CTVO) in 1 patient, and non-irradiated low-risk area (CTV0) in 2 patients. The volume of selective lymph node irradiation was below the standard radiation volume in 33 patients (mean of 118.6 cc per patient). This decrease in irradiated volume was associated with greater treatment compliance and reduced secondary toxicity. The three-year actuarial nodal control rate was 80%. CONCLUSION This selective postoperative neck irradiation protocol was associated with a similar failure pattern to that observed after standard neck irradiation and achieved a significant reduction in target volume and secondary toxicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is one of the few studies that have explored the value of baseline symptoms and health-related quality of life (HRQOL) in predicting survival in brain cancer patients. Baseline HRQOL scores (from the EORTC QLQ-C30 and the Brain Cancer Module (BN 20)) were examined in 490 newly diagnosed glioblastoma cancer patients for the relationship with overall survival by using Cox proportional hazards regression models. Refined techniques as the bootstrap re-sampling procedure and the computation of C-indexes and R(2)-coefficients were used to try and validate the model. Classical analysis controlled for major clinical prognostic factors selected cognitive functioning (P=0.0001), global health status (P=0.0055) and social functioning (P<0.0001) as statistically significant prognostic factors of survival. However, several issues question the validity of these findings. C-indexes and R(2)-coefficients, which are measures of the predictive ability of the models, did not exhibit major improvements when adding selected or all HRQOL scores to clinical factors. While classical techniques lead to positive results, more refined analyses suggest that baseline HRQOL scores add relatively little to clinical factors to predict survival. These results may have implications for future use of HRQOL as a prognostic factor in cancer patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some sites of extrapulmonary tuberculosis and focal complications of brucellosis are very difficult to differentiate clinically, radiologically, and even histopathologically. Conventional microbiological methods for the diagnosis of extrapulmonary tuberculosis and complicated brucellosis not only lack adequate sensitivity, they are also time consuming, which could lead to an unfavourable prognosis. The aim of this work was to develop a multiplex real-time PCR assay based on SYBR Green I to simultaneously detect Brucella spp and Mycobacterium tuberculosis complex and evaluate the efficacy of the technique with different candidate genes. The IS711, bcsp31 and omp2a genes were used for the identification of Brucella spp and the IS6110, senX3-regX3 and cfp31 genes were targeted for the detection of the M. tuberculosis complex. As a result of the different combinations of primers, nine different reactions were evaluated. A test was defined as positive only when the gene combinations were capable of co-amplifying both pathogens in a single reaction tube and showed distinguishable melting temperatures for each microorganism. According to the melting analysis, only three combinations of amplicons (senX3-regX3+bcsp31, senX3-regX3+IS711 and IS6110+IS711) were visible. Detection limits of senX3-regX3+bcsp31 and senX3-regX3+IS711 were of 2 and 3 genome equivalents for M. tuberculosis complex and Brucella while for IS6110+IS711 they were of 200 and 300 genome equivalents, respectively. The three assays correctly identified all the samples, showing negative results for the control patients. The presence of multicopy elements and GC content were the components most influencing the efficiency of the test; this should be taken into account when designing a multiplex-based SYBR Green I assay. In conclusion, multiplex real time PCR assays based on the targets senX3-regX3+bcsp31 and senX3-regX3+IS711 using SYBR Green I are highly sensitive and reproducible. This may therefore be a practical approach for the rapid differential diagnosis between extrapulmonary tuberculosis and complicated brucellosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Todos los cuerpos emiten luz espontaneamente al ser calentados. El espectro de radiacion es una funcion de la temperatura y el material. Sin embargo, la mayoria de los materiales irradia, en general, en una banda espectral amplia. Algunas matereiales, por el contrario, son capaces de concentrar la radiacion termica en una banda espectral mucho mas estrecha. Estos materiales se conocen como emisores selectivos y su uso tiene un profundo impacto en la eficiencia de sistemas sistemas tales como iluminacion y conversion de energia termofotovoltaica. De los emisores selectivos se espera que sean capaces de operar a altas temperaturas y que emitan en una banda espectral muy concisa. Uno de los metodos mas prometedores para controlar y disenar el espectro de emision termico es la utilizacion de cristales fotonicos. Los cristales fotonicos son estructuras periodicas artificiales capaces de controlar y confinar la luz de formas sin precedentes. Sin embargo, la produccion de dichas estructuras con grandes superficies y capaces de soportar altas temperaturas sigue siendo una dificil tarea. Este trabajo esta dedicada al estudio de las propiedades de emision termica de estructuras 3D de silicio macroporoso en el rango espectral mid-IR (2-30 m). En particular, este trabajo se enfoca en reducir la elevada emisividad del silicio cristalino. Las muestras estudiadas en este trabajo tienen una periodicidad de 4 m, lo que limitan los resultados obtenidos a la banda del infrarrojo medio, aunque estructuras mucho mas pequenas son tecnologicamente realizables con el metodo de fabricacion utilizado. Hemos demostrado que el silicio macroporoso 3D puede inhibir completamente la emision termica en su superficie. Mas aun, esta banda se puede ajustar en un amplio margen mediante pequenos cambios durante la formacion de los macroporos. Tambien hemos demostrado que tanto el ancho como la frecuencia de la banda de inhibicion se puede doblar mediante la aplicacion de tecnicas de postprocesado adecuadas. Finalmente hemos mostrado que es posible crear bandas de baja emisividad arbitrariamente anchas mediante estructuras macroporosas aperiodicas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The public primary school system in the State of Geneva, Switzerland, is characterized by centrally evaluated pupil performance measured with the use of standardized tests. As a result, consistent data are collected among the system. The 2010-2011 dataset is used to develop a two-stage data envelopment analysis (DEA) of school efficiency. In the first stage, DEA is employed to calculate an individual efficiency score for each school. It shows that, on average, each school could reduce its inputs by 7% whilst maintaining the same quality of pupil performance. The cause of inefficiency lies in perfectible management. In the second stage, efficiency is regressed on school characteristics and environmental variables;external factors outside of the control of headteachers. The model is tested for multicollinearity, heteroskedasticity and endogeneity. Four variables are identified as statistically significant. School efficiency is negatively influenced by (1) the provision of special education, (2) the proportion of disadvantaged pupils enrolled at the school and (3) operations being held on multiple sites, but positively influenced by school size (captured by the number of pupils). The proportion of allophone pupils; schools located in urban areas and the provision of reception classes for immigrant pupils are not significant. Although the significant variables influencing school efficiency are outside of the control of headteachers, it is still possible to either boost the positive impact or curb the negative impact. Dans le canton de Genève (Suisse), les écoles publiques primaires sont caractérisées par un financement assuré par les collectivités publiques (canton et communes) et par une évaluation des élèves à l'aide d'épreuves standardisées à trois moments distincts de leur scolarité. Cela permet de réunir des informations statistiques consistantes. La base de données de l'année 2010-2011 est utilisée dans une analyse en deux étapes de l'efficience des écoles. Dans une première étape, la méthode d'analyse des données par enveloppement (DEA) est utilisée pour calculer un score d'efficience pour chaque école. Cette analyse démontre que l'efficience moyenne des écoles s'élève à 93%. Chaque école pourrait, en moyenne, réduire ses ressources de 7% tout en conservant constants les résultats des élèves aux épreuves standardisées. La source de l'inefficience réside dans un management des écoles perfectible. Dans une seconde étape, les scores d'efficience sont régressés sur les caractéristiques des écoles et sur des variables environnementales. Ces variables ne sont pas sous le contrôle (ou l'influence) des directeurs d'école. Le modèle est testé pour la multicolinéartié, l'hétéroscédasticité et l'endogénéité. Quatre variables sont statistiquement significatives. L'efficience des écoles est influencée négativement par (1) le fait d'offrir un enseignement spécialisé en classe séparée, (2) la proporition d'élèves défavorisés et (3) le fait d'opérer sur plusieurs sites différents. L'efficience des écoles est influencée positivement par la taille de l'école, mesurée par le nombre d'élèves. La proporition d'élèves allophones, le fait d'être situé dans une zone urbaine et d'offrir des classes d'accueil pour les élèves immigrants constituent autant de variables non significatives. Le fait que les variables qui influencent l'efficience des écoles ne soient pas sous le contrôle des directeurs ne signifie pas qu'il faille céder au fatalisme. Différentes pistes sont proposées pour permettre soit de réduire l'impact négatif soit de tirer parti de l'impact positif des variables significatives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Lung cancer remains one of the most prevalent forms of cancer. Radiotherapy, with or without other therapeutic modalities, is an effective treatment. Our objective was to report on the use of radiotherapy for lung cancer, its variability in our region, and to compare our results with the previous study done in 2004 (VARA-I) in our region and with other published data. METHODS We reviewed the clinical records and radiotherapy treatment sheets of all patients undergoing radiotherapy for lung cancer during 2007 in the 12 public hospitals in Andalusia, an autonomous region of Spain. Data were gathered on hospital, patient type and histological type, radiotherapy treatment characteristics, and tumor stage. RESULTS 610 patients underwent initial radiotherapy. 37% of cases had stage III squamous cell lung cancer and were treated with radical therapy. 81% of patients with non-small and small cell lung cancer were treated with concomitant chemo-radiotherapy and the administered total dose was ≥60 Gy and ≥45 Gy respectively. The most common regimen for patients treated with palliative intent (44.6%) was 30 Gy. The total irradiation rate was 19.6% with significant differences among provinces (range, 8.5-25.6%; p<0.001). These differences were significantly correlated with the geographical distribution of radiation oncologists (r=0.78; p=0.02). Our results were similar to other published data and previous study VARA-I. CONCLUSIONS Our results shows no differences according to the other published data and data gathered in the study VARA-I. There is still wide variability in the application of radiotherapy for lung cancer in our setting that significantly correlates with the geographical distribution of radiation oncologists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Since 1982, the Radiation Oncology Group of the EORTC (EORTC ROG) has pursued an extensive Quality Assurance (QA) program involving all centres actively participating in its clinical research. The first step is the evaluation of the structure and of the human, technical and organisational resources of the centres, to assess their ability to comply with the current requirements for high-tech radiotherapy (RT). MATERIALS AND METHODS: A facility questionnaire (FQ) was developed in 1989 and adapted over the years to match the evolution of RT techniques. We report on the contents of the current FQ that was completed online by 98 active EORTC ROG member institutions from 19 countries, between December 2005 and October 2007. RESULTS: Similar to the data collected previously, large variations in equipment, staffing and workload between centres remain. Currently only 15 centres still use a Cobalt unit. All centres perform 3D Conformal RT, 79% of them can perform IMRT and 54% are able to deliver stereotactic RT. An external reference dosimetry audit (ERDA) was performed in 88% of the centres for photons and in 73% for electrons, but it was recent (<2 years) in only 74% and 60%, respectively. CONCLUSION: The use of the FQ helps maintain the minimum quality requirements within the EORTC ROG network: recommendations are made on the basis of the analysis of its results. The present analysis shows that modern RT techniques are widely implemented in the clinic but also that ERDA should be performed more frequently. Repeated assessment using the FQ is warranted to document the future evolution of the EORTC ROG institutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Combined radiation and hormone therapies have become common clinical practice in recent years for locally-advanced prostate cancers. The use of such concomitant therapy in the treatment of breast disease has been infrequently reported in the literature, but seems justified given the common hormonal dependence of breast cancer and the potential synergistic effect of these two treatment modalities. As adjuvant therapy, two strategies are used in daily clinical practice: upfront aromatase inhibitors or sequentially after a variable delay of tamoxifen. These molecules may, thus, interact with radiotherapy. Retrospectives studies recently published did not show any differences in terms of locoregional recurrences between concurrent or sequential radiohormonotherapy. Lung and skin fibroses due to concurrent treatment are still under debate. Nevertheless, late side effects appeared to be increased by such a treatment, particularly in hypersensitive patients identified at risk by the lymphocyte predictive test. Concurrent radiohormonotherapy should, thus, be delivered cautiously at least for these patients. This article details the potent advantages and risks of concurrent use of adjuvant hormonotherapy and radiotherapy in localized breast cancers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrafractionation of radiation therapy is a novel regimen consisting of irradiating tumors several times daily, delivering low doses (<0.75 Gy) at which hyperradiosensitivity occurs. We recently demonstrated the high efficiency of ultrafractionated radiotherapy (RT) on glioma xenografts and report here on a phase II clinical trial to determine the safety, tolerability, and efficacy of an ultrafractionation regimen in patients with newly and inoperable glioblastoma (GBM). Thirty-one patients with histologically proven, newly diagnosed, and unresectable supratentorial GBM (WHO grade IV) were enrolled. Three daily doses of 0.75 Gy were delivered at least 4 hours apart, 5 days per week over 6-7 consecutive weeks (90 fractions for a total of 67.5 Gy). Conformal irradiation included the tumor bulk with a margin of 2.5 cm. The primary end points were safety, toxicity, and tolerability, and the secondary end points were overall survival (OS) and progression-free survival (PFS). Multivariate analysis was used to compare the OS and PFS with the EORTC-NCIC trial 26981-22981/CE.3 of RT alone vs radiation therapy and temozolomide (TMZ). The ultrafractionation radiation regimen was safe and well tolerated. No acute Grade III and/or IV CNS toxicity was observed. Median PFS and OS from initial diagnosis were 5.1 and 9.5 months, respectively. When comparing with the EORTC/NCIC trial, in both PFS and OS multivariate analysis, ultrafractionation showed superiority over RT alone, but not over RT and TMZ. The ultrafractionation regimen is safe and may prolong the survival of patients with GBM. Further investigation is warranted and a trial associating ultra-fractionation and TMZ is ongoing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report was prepared by a committee of city, county and state representatives. The committee met throughout 2002 with the purpose of reviewing and making recommendations to improve the efficiency and operation of Iowa's road and street system. This report is referenced in SF 451 and in Code Section 306.8A.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expressions relating spectral efficiency, power, and Doppler spectrum, are derived for Rayleigh-faded wireless channels with Gaussian signal transmission. No side information on the state of the channel is assumed at the receiver. Rather, periodic reference signals are postulated in accordance with the functioning of most wireless systems. The analysis relies on a well-established lower bound, generally tight and asymptotically exact at low SNR. In contrast with most previous studies, which relied on block-fading channel models, a continuous-fading model is adopted. This embeds the Doppler spectrum directly in the derived expressions, imbuing them with practical significance. Closed-form relationships are obtained for the popular Clarke-Jakes spectrum and informative expansions, valid for arbitrary spectra, are found for the low- and high-power regimes. While the paper focuses on scalar channels, the extension to multiantenna settings is also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expressions relating spectral efficiency, power and Doppler spectrum are derived for low-power Rayleighfaded wireless channels with proper complex signaling. Noside information on the state of the channel is assumed at the receiver. Rather, periodic reference signals are postulated inaccordance with the functioning of most wireless systems. In contrast with most previous studies, which relied on block-fading channel models, a continuous-fading model is adopted. This embeds the Doppler spectrum directly in thederived expressions thereby imbuing them with practical significance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel efficiencybased evaluation of sentence and word aligners. This assessment is critical in order to make a reliable use in industrial scenarios. The evaluation shows that the resourcesrequired by aligners differ rather broadly. Subsequently, we establish limitation mechanisms on a set of aligners deployed as web services. These results, paired with the quality expected from the aligners, allow providers to choose the most appropriate aligner according to the task at hand.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.