896 resultados para Quality system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An optimisation technique to solve transmission network expansion planning problem, using the AC model, is presented. This is a very complex mixed integer nonlinear programming problem. A constructive heuristic algorithm aimed at obtaining an excellent quality solution for this problem is presented. An interior point method is employed to solve nonlinear programming problems during the solution steps of the algorithm. Results of the tests, carried out with three electrical energy systems, show the capabilities of the method and also the viability of using the AC model to solve the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, networks must support applications such as: distance learning, electronic commerce, access to Internet, Intranets and Extranets, voice over IP (Internet Protocol) and many others. These new applications, employing data, voice, and video traffic, require high bandwidth and Quality of Service (QoS). The ATM (Asynchronous Transfer Mode) technology, together with dynamic resource allocation methods, offers network connections that guarantee QoS parameters, such as minimum losses and delays. This paper presents a system that uses Network Management Functions together with dynamic resource allocation for provision of the end-to-end QoS parameters for rt-VBR connections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intensive grazing systems for beef females, based on abundant availability of high quality forages and supplementary concentrates, may affect fetal development. The objective of this study was to determine the effect of grazing system on length of gestation, fetal development, and characteristics of the calf at birth. Twenty-four pregnant (bred to Nellore bulls) Nellore females were allocated into two groups. The control group (G1) grazed Brachiaria decumbens (signal grass) in a traditional (extensive) grazing system and the second group (G2) were managed on Panicum maximumcv. Tanzania 1 (Tanzania grass) in an intensive grazing system. Fetal development was evaluated by ultrasonography on days 31, 45, 59, 94, 122, 220, and 255 of gestation. The diameter of the amniotic and allantoic cavities, crown-rump length, circumference, and diameter of the head and ocular orbit were determined. At birth, calves were weighed and height, length, thoracic circumference, and ocular orbit and bi-parietal diameters were measured. There were no differences (P > 0.05) in fetal development. The G1 cows had a longer gestation period (4.5 days; P < 0.05) and their calves had greater (P < 0.05) weight, height, length, and thoracic circumference at birth. In conclusion, Nellore females raised under intensive pasture management conditions, had significantly shorter gestation and smaller calves at birth than those raised under extensive pasture management conditions. Therefore, adoption of new management practices (e.g. intensive pasture management), should take into consideration animal behavior and productivity. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two projects of water treatment for public water supply were developed and operated by using combined systems of constructed wetlands. One of the projects was carried out in the town of Analandia, Sao Paulo, Brazil and wetlands with floating aquatic plants associated to the HDS system were used. Nearly 6480 inhabitants were supplied. The other conducted project was an experimental station in partnership with SABESP (Sao Paulo State Sanitation Agency/Brazil), for the pretreatment of 1700 l.s-1 of waters from the Cotia River, which is used for the population's supply after conventional treatment at the Lower Cotia Water Treatment Station. For this pilot project, wetlands with emergents and floating plants associated to the HDS system were used. The proposed objectives were achieved in both projects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The project is being conducted in the town of Analândia, São Paulo, Brazil. The constructed wetlands system for water supply consists of a channel with floating aquatic macrophytes, HDS system (Water Decontamination with Soil - Patent PI 850.3030), chlorinating system, filtering system and distribution. The project objectives include investigating the process variables to further optimize design and operation factors, evaluating the relation of nutrients and plants development, biomass production, shoot development, nutrient cycling and total and fecal coliforms removal, comparing the treatment efficiency among the seasons of the year; and moreover to compare the average values obtained between February and June 1998 (Salati et al., 1998) with the average obtained for the same parameters between March and June 2000. Studies have been developed in order to verify during one year the drinking quality of the water for the following parameters: turbidity, color, pH, dissolved oxygen, total of dissolved solids, COD, chloride, among others, according to the Ministry of Health's Regulation 36. This system of water supply projected to treat 15 L s-1 has been in continuous operation for 2 years, it was implemented with support of the National Environment Fund (FNMA), administered by the Center of Environmental Studies (CEA-UNESP), while the technical supervision and design were performed by the Institute of Applied Ecology. The actual research project is being supported by FAPESP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The computational program called GIS_EM (Geographic Information System for Environmental Monitoring), a software devised to manage geographic information for monitoring soil, surface, and ground water, developed for use in the Health, Safety, and Environment Division of Paulinia Refinery is presented. This program enables registering and management of alphanumeric information pertaining to specific themes such as drilling performed for sample collection and for installation of monitoring wells, geophysical and other tests, results of chemical analyses of soil, surface, and groundwater, as well as reference values providing orientation for soil and water quality, such as EPA, Dutch List, etc. Management of such themes is performed by means of alphanumeric search tools, with specific filters and, in the case of spatial search, through the selection of spatial elements (themes) in map view. Documents existing in digital form, such as reports, photos, maps, may be registered and managed in the network environment. As the system centralizes information generated upon environmental investigations, it expedites access to and search of documents produced and stored in the network environment, minimizing search time and the need to file printed documents. This is an abstract of a paper presented at the AIChE Annual Meeting and Fall Showcase (Cincinnati, OH 10/30/2005-11/4/2005).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the health-related quality of life in children with functional defecation disorders. Methods: One hundred children seen consecutively were enrolled and subdivided into three subsets according to the Roma II classification criteria: functional constipation (n = 57), functional fecal retention (n = 29) and nonretentive functional soiling (n = 14). The generic instrument Child Health Questionnaire - Parent Form 50 (CHQ-PF50®), was used to measure quality of life and to assess the impact of these disorders from the point of view of parents. The instrument measures physical and psychosocial wellbeing in 15 health domains, each of which is graded on a scale from 0 to 100, with higher values indicating better health and greater wellbeing. Ten of these are then used to obtain two aggregated and summary scores: the physical and psychosocial scores. Results: No statistically significant differences were detected between subsets in terms of demographic or anthropometric characteristics. In 14 domains, children with defecation disorders scored lower than healthy children. When subsets were compared, statistically significant differences were detected between children with nonretentive functional soiling (lower scores) and those with functional constipation. Physical and psychosocial scores for the entire sample were lower than those for the group of healthy children used as controls. Conclusions: The CHQ-PF50® was considered adequate for demonstrating compromised quality of life in children with functional defecation disorders, as has been reported for other diseases, being a useful tool for making treatment decisions and for patient follow-up. Copyright © 2006 by Sociedade Brasileira de Pediatria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To examine the change in health-related quality of life (HRQOL) and its determinants in children with juvenile idiopathic arthritis (JIA) treated with methotrexate (MTX). Methods: Patients were extracted from the PRINTO clinical trial which aimed to evaluate the efficacy and safety profile of MTX administered in standard, intermediate or higher doses (10, 15 and 30 mg/m2/week respectively). Children with polyarticular-course JIA, who were less than 18 years and had a complete HRQOL assessment were included. Results: A total of 521 children were included. At baseline, patients with JIA showed poorer HRQOL (p<0.01) than healthy children. In 207/412 (50%) and 63 (15%) children, HRQOL values were 2 standard deviations below the mean of healthy controls in the physical and psychosocial summary scale, respectively. After 6 months of treatment with standard dose MTX, there was a statistically significant improvement in all HRQOL health concepts, particularly the physical ones. Similar improvements were observed in those who did not respond to a standard dose of MTX and were subsequently randomised to a higher dose. The presence of marked disability at baseline was associated with a fivefold increased risk of retaining poor physical health after 6 months of active treatment with standard dose MTX. Other less important determinants of retaining poor physical well-being were the baseline level of systemic inflammation, pain intensity and an antinuclear-antibody-negative status. Conclusions: MTX treatment produces a significant improvement across a wide range of HRQOL components, particularly in the physical domains, in patients with JIA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE.