914 resultados para Principle of non-contradiction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coumarins are a large family of natural and synthetic compounds exerting different pharmacological effects, including cytotoxic, anti-inflammatory or antimicrobial. In the present communication we report the synthesis of a series of 12 diversely substituted 4-oxycoumarin derivatives including methoxy substituted 4-hydroxycoumarins, methyl, methoxy or unsubstituted 3-aryl-4-hydroxycoumarins and 4-benzyloxycoumarins and their anti-proliferative effects on breast adenocarcinoma cells (MCF-7), human promyelocytic leukemia cells (HL-60), human histiocytic lymphoma cells (U937) and mouse neuroblastoma cells (Neuro2a). The most potent bioactive molecule was the 4-hydroxy-5,7-dimethoxycoumarin (compound 1) which showed similar potency (IC(50) 0.2-2 μM) in all cancer cell lines tested. This non-natural product reveals a simple bioactive scaffold which may be exploited in further studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This investigation was a basal study that used a mouse model of xerostomia to identify protein biomarkers of xerostomia in saliva. We identified genes expressed differently in parotid glands from non-obese diabetic mice with diabetes and those from control mice; subsequently, we investigated expression of the proteins encoded by these genes in parotid glands and saliva. MATERIALS AND METHODS: DNA microarray and real-time PCR analyses were performed to detect differences between NOD/ShiJcl and C57BL/6JJcl (control) female mice in gene expression from parotid glands or parotid acinar cells. Subsequently, protein expression was assessed using immunoblotting and immunohistochemistry. Similarly, enzyme activity in saliva was assessed using zymography. RESULTS: Based on gene expression analyses, Chia expression was higher in diabetic mice than non-diabetic mice and control mice; similarly, expression of chitinase, the protein encoded by Chia, was higher in diabetic mice. Saliva from NOD/ShiJcl mice had more chitinase than saliva from control mice. CONCLUSIONS: Chitinase was highly expressed in parotid acinar cells from diabetic mice compared with non-diabetic and control mice. Increased chitinase expression and enzyme activity may characterize the autoimmune diabetes in mice; however, further investigation is required to assess its use as a biomarker of xerostomia in humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effectively assessing subtle hepatic metabolic functions by novel non-invasive tests might be of clinical utility in scoring NAFLD (non-alcoholic fatty liver disease) and in identifying altered metabolic pathways. The present study was conducted on 39 (20 lean and 19 obese) hypertransaminasemic patients with histologically proven NAFLD {ranging from simple steatosis to severe steatohepatitis [NASH (non-alcoholic steatohepatitis)] and fibrosis} and 28 (20 lean and eight overweight) healthy controls, who underwent stable isotope breath testing ([(13)C]methacetin and [(13)C]ketoisocaproate) for microsomal and mitochondrial liver function in relation to histology, serum hyaluronate, as a marker of liver fibrosis, and body size. Compared with healthy subjects and patients with simple steatosis, NASH patients had enhanced methacetin demethylation (P=0.001), but decreased (P=0.001) and delayed (P=0.006) ketoisocaproate decarboxylation, which was inversely related (P=0.001) to the degree of histological fibrosis (r=-0.701), serum hyaluronate (r=-0.644) and body size (r=-0.485). Ketoisocaproate decarboxylation was impaired further in obese patients with NASH, but not in patients with simple steatosis and in overweight controls. NASH and insulin resistance were independently associated with an abnormal ketoisocaproate breath test (P=0.001). The cut-off value of 9.6% cumulative expired (13)CO(2) for ketoisocaproate at 60 min was associated with the highest prediction (positive predictive value, 0.90; negative predictive value, 0.73) for NASH, yielding an overall sensitivity of 68% and specificity of 94%. In conclusion, both microsomal and mitochondrial functions are disturbed in NASH. Therefore stable isotope breath tests may usefully contribute to a better and non-invasive characterization of patients with NAFLD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Lung retrieval from non-heart-beating donors (NHBD) has been introduced into clinical practice successfully. However, because of potentially deleterious effects of warm ischemia on microvascular integrity, use of NHBD lungs is limited by short tolerable time periods before preservation. Recently, improvement of NHBD graft function was demonstrated by donor pre-treatment using aerosolized Ventavis (Schering Inc., Berlin, Germany). Currently, there is no information whether additional application of this approach in reperfusion can further optimize immediate graft function. MATERIAL AND METHODS: Asystolic pigs (n = 5/group) were ventilated for 180-min of warm ischemia (groups 1-3). In groups 2 and 3, 100 microg Ventavis were aerosolized over 30-min using an ultrasonic nebulizer (Optineb). Lungs were then retrogradely preserved with Perfadex and stored for 3-h. After left lung transplantation and contralateral lung exclusion, grafts were reperfused for 6-h. Only in group 3, another dose of 100 microg Ventavis was aerosolized during the first 30-min of reperfusion. Hemodynamics, pO2/FiO2 and dynamic compliance were monitored continuously and compared to controls. Intraalveolar edema was quantified stereologically, and extravascular-lung-water-index (EVLWI) was measured. Statistics comprised ANOVA analysis with repeated measurements. RESULTS: Dynamic compliance was significantly lower in both Ventavis groups, but additional administration did not result in further improvement. Oxygenation, pulmonary hemodynamics, EVLWI and intraalveolar edema formation were comparable between groups. CONCLUSIONS: Alveolar deposition of Ventavis in NHBD lungs before preservation significantly improves dynamic lung compliance and represents an important strategy for improvement of preservation quality and expansion of warm ischemic intervals. However, additional application of this method in early reperfusion is of no benefit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Neonates in a neonatal intensive care unit are exposed to a high number of painful procedures. Since repeated and sustained pain can have consequences for the neurological and behaviour-oriented development of the newborn, the greatest attention needs to be paid to systematic pain management in neonatology. Non-pharmacological treatment methods are being increasingly discussed with regard to pain prevention and relief either alone or in combination with pharmacological treatment. AIMS: To identify effective non-pharmacological interventions with regard to procedural pain in neonates. METHODS: A literature search was conducted via the MedLine, CINAHL, Cochrane Library databases and complemented by a handsearch. The literature search covered the period from 1984 to 2004. Data were extracted according to pre-defined criteria by two independent reviewers and methodological quality was assessed. RESULTS: 13 randomised controlled studies and two meta-analyses were taken into consideration with regard to the question of current nursing practice of non-pharmacological pain management methods. The selected interventions were "non-nutritive sucking", "music", "swaddling", "positioning", "olfactory and multisensorial stimulation", "kangaroo care" and "maternal touch". There is evidence that the methods of "non-nutritive sucking", "swaddling" and "facilitated tucking" do have a pain-alleviating effect on neonates. CONCLUSIONS: Some of the non-pharmacological interventions have an evident favourable effect on pulse rate, respiration and oxygen saturation, on the reduction of motor activity, and on the excitation states after invasive measures. However, unambiguous evidence of this still remains to be presented. Further research should emphasise the use of validated pain assessment instruments for the evaluation of the pain-alleviating effect of non-pharmacological interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Patients coinfected with hepatitis C virus (HCV) and HIV experience higher mortality rates than patients infected with HIV alone. We designed a study to determine whether risks for later mortality are similar for HCV-positive and HCV-negative individuals when subjects are stratified on the basis of baseline CD4+ T-cell counts. METHODS: Antiretroviral-naive individuals, who initiated highly active antiretroviral therapy (HAART) between 1996 and 2002 were included in the study. HCV-positive and HCV-negative individuals were stratified separately by baseline CD4+ T-cell counts of 50 cell/microl increments. Cox-proportional hazards regression was used to model the effect of these strata with other variables on survival. RESULTS: CD4+ T-cell strata below 200 cells/microl, but not above, imparted an increased relative hazard (RH) of mortality for both HCV-positive and HCV-negative individuals. Among HCV-positive individuals, after adjustment for baseline age, HIV RNA levels, history of injection drug use and adherence to therapy, only CD4+ T-cell strata of <50 cells/microl (RH=4.60; 95% confidence interval [CI] 2.72-7.76) and 50-199 cells/microl (RH=2.49; 95% CI 1.63-3.81) were significantly associated with increased mortality when compared with those initiating therapy at cell counts >500 cells/microl. The same baseline CD4+ T-cell strata were found for HCV-negative individuals. CONCLUSION: In a within-groups analysis, the baseline CD4+ T-cell strata that are associated with increased RHs for mortality are the same for HCV-positive and HCV-negative individuals initiating HAART. However, a between-groups analysis reveals a higher absolute mortality risk for HCV-positive individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND/AIMS: We investigated the molecular response of a non-ischemic hypoxic stress in the liver, in particular, to distinguish its hepatoprotective potential. METHODS: The livers of mice were subjected to non-ischemic hypoxia by clamping the hepatic-artery (HA) for 2h while maintaining portal circulation. Hypoxia was defined by a decrease in oxygen saturation, the activation of hypoxia-inducible factor (HIF)-1 and the mRNA up-regulation of responsive genes. To demonstrate that the molecular response to hypoxia may in part be hepatoprotective, pre-conditioned animals were injected with an antibody against Fas (Jo2) to induce acute liver failure. Hepatocyte apoptosis was monitored by caspase-3 activity, cleavage of lamin A and animal survival. RESULTS: Clamping the HA induced a hypoxic stress in the liver in the absence of severe metabolic distress or tissue damage. The hypoxic stimulus was sufficient to activate the HIF-1 signalling pathway and up-regulate hepatoprotective genes. Pre-conditioning the liver with hypoxia was able to delay the onset of Fas-mediated apoptosis and prolong animal survival. CONCLUSIONS: Our data reveal that hepatic cells can sense and respond to a decrease in tissue oxygenation, and furthermore, that activation of hypoxia-inducible signalling pathways function in part to promote liver cell survival.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. RESULTS: No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). CONCLUSIONS: Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. CLINICAL APPLICATION: Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest. METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading. RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing. CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.