789 resultados para Predictive-validity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regarding the Pauli principle in quantum field theory and in many-body quantum mechanics, Feynman advocated that Pauli's exclusion principle can be completely ignored in intermediate states of perturbation theory. He observed that all virtual processes (of the same order) that violate the Pauli principle cancel out. Feynman accordingly introduced a prescription, which is to disregard the Pauli principle in all intermediate processes. This ingenious trick is of crucial importance in the Feynman diagram technique. We show, however, an example in which Feynman's prescription fails. This casts doubts on the general validity of Feynman's prescription. [S1050-2947(99)04604-1].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel strategy to handle divergences typical of perturbative calculations is implemented for the Nambu-Jona-Lasinio model and its phenomenological consequences investigated. The central idea of the method is to avoid the critical step involved in the regularization process, namely, the explicit evaluation of divergent integrals. This goal is achieved by assuming a regularization distribution in an implicit way and making use, in intermediary steps, only of very general properties of such regularization. The finite parts are separated from the divergent ones and integrated free from effects of the regularization. The divergent parts are organized in terms of standard objects, which are independent of the ( arbitrary) momenta running in internal lines of loop graphs. Through the analysis of symmetry relations, a set of properties for the divergent objects are identified, which we denominate consistency relations, reducing the number of divergent objects to only a few. The calculational strategy eliminates unphysical dependencies of the arbitrary choices for the routing of internal momenta, leading to ambiguity-free, and symmetry-preserving physical amplitudes. We show that the imposition of scale properties for the basic divergent objects leads to a critical condition for the constituent quark mass such that the remaining arbitrariness is removed. The model becomes predictive in the sense that its phenomenological consequences do not depend on possible choices made in intermediary steps. Numerical results are obtained for physical quantities at the one-loop level for the pion and sigma masses and pion-quark and sigma-quark coupling constants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O exame colpocitológico ou teste de Papanicolaou permite o diagnóstico precoce do câncer de colo do útero. O êxito no rastreamento desta doença dependerá, além de outros fatores, da acuidade diagnóstica do exame colpocitológico. Objetivos: Avaliar a acurácia diagnóstica da citologia cervicovaginal na detecção de lesões cervicais através da comparação citoistopatológica. Material e métodos: Avaliou-se o grau de concordância entre os exames citológico e histopatológico de 373 pacientes atendidas em um hospital universitário no período de 1990 a 1997 e foram calculados os indicadores: sensibilidade, especificidade, valores preditivos positivos e negativos e as taxas de falsos positivos e falsos negativos do exame. Resultados: A taxa bruta de concordância citoistopatológica foi de 65,1%. A sensibilidade do exame foi alta (96,0%), no entanto sua especificidade foi baixa (51,5%), significando a inclusão de muitos resultados falsos positivos. A taxa de falsos positivos foi de 48,4%, enquanto a de falsos negativos foi de 4%. Discussão: Apesar de a sensibilidade do teste ser alta, sua especificidade é baixa, significando que muitas mulheres seriam falsamente diagnosticadas como doentes, levando a um número elevado de resultados falsos positivos e custos desnecessários, além do potencial caráter iatrogênico que esta ação poderia assumir. No entanto, um exame altamente sensível é o teste de escolha para programas de rastreamento de câncer cervical na população feminina. Conclusões: Para garantir a acuidade diagnóstica do teste de Papanicolaou são essenciais atividades de controle de qualidade nos laboratórios, tanto do procedimento colpocitológico quanto do histopatológico, permitindo, assim, o êxito na detecção precoce e no tratamento das lesões cervicais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do artigo foi avaliar o uso da lógica fuzzy para estimar possibilidade de óbito neonatal. Desenvolveu-se um modelo computacional com base na teoria dos conjuntos fuzzy, tendo como variáveis peso ao nascer, idade gestacional, escore de Apgar e relato de natimorto. Empregou-se o método de inferência de Mamdani, e a variável de saída foi o risco de morte neonatal. Criaram-se 24 regras de acordo com as variáveis de entrada, e a validação do modelo utilizou um banco de dados real de uma cidade brasileira. A acurácia foi estimada pela curva ROC; os riscos foram comparados pelo teste t de Student. O programa MATLAB 6.5 foi usado para construir o modelo. Os riscos médios foram menores para os que sobreviveram (p < 0,001). A acurácia do modelo foi 0,90. A maior acurácia foi com possibilidade de risco igual ou menor que 25% (sensibilidade = 0,70, especificidade = 0,98, valor preditivo negativo = 0,99 e valor preditivo positivo = 0,22). O modelo mostrou acurácia e valor preditivo negativo bons, podendo ser utilizado em hospitais gerais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the reliability of the standing measurement of hand-to-foot bioimpedance compared with measurements made in the lying position.Research Methods and Procedures: In 205 volunteers 6 to 89 years of age, 111 males and 94 females from six ethnic groups, effects of posture, time, and age on hand-to-foot resistance were studied over a range of body size. The effect of time in a position on resistance was also recorded in a small subset (n = 10), and repeat measurements over 3 days at the same time of the day were recorded in another subset (n = 12).Results: Lying impedance was consistently higher than standing, with the relationship (resistance lying/resistance standing) for the children (5 to 14 years) being 1.031, progressing to a ratio of 1.016 in those >60 years. The time spent static in either position did change resistance measurements - a decrease of up to 9 Omega (mean 5 Omega, 1.0%) over 10 minutes of standing and an increase of up to 7 Omega (mean 3 Omega, 0.7%) with lying.Discussion: In the field, measurements of hand-to-foot bioimpedance can be made in the standing position, and, with appropriate adjustment, previously validated recumbent equations can be used. Given that errors in the measurement of height and weight also affect the reliability of the derivation of body fat from bioelectrical conductance, the errors that may arise from a more practical standing measurement rather than lying are minimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the critical speed (CS) for track cycling and to assess whether a lactate steady state occurs at this speed. Fourteen competitive cyclists performed the following tests on an official cycling track (333.3 m): 1) incremental test for determination of the intensity corresponding to 4 mM of blood lactate (onset of blood lactate accumulation, OBLA) and maximal oxygen uptake (VO(2)max); 2) CS: 3 maximal bouts for distances of 2, 4 and 6 km executed in random order and with a period of recovery of 40 to 50 min between bouts. CS was determined for each subject from the linear regression between the distance and the time taking to cycle it; 3) Endurance test in which subjects were instructed to pedal at 100% of their individually determined CS for 30 min. At the 10(th) and 30(th) min (or upon exhaustion), 25 mul of blood were collected from ear lobe for later analysis of blood lactate [Lac]b. An increase less than or equal to1 mM between 10 and 30 min of exercise was considered as the criterion for the occurrence of the lactate steady state. CS (49.6 +/- 8.6 ml.kg(-1).min(-1); 36.9 +/- 2.7 km.h(-1)) was significantly higher than OBLA (43.7 8.0 ml.kg(-1).min(-1); 35.24 +/- 2.6 km.h(-1)) although the two parameters were highly correlated (r=0.97). During the endurance test, only 8 of the 14 subjects completed the 30 min period at CS. of these 8 subjects, only 2 presented a lactate steady state. Time to exhaustion at CS was 20.3 +/- 1.6 min for the remaining 6 subjects. The 12 subjects who did not reach a lactate steady state presented mean [Lac]b values of 7.4 +/- 1.3 mM at 10 min and of 9.4 +/- 1.9 mM at the end of the test (exhaustion), characterizing an exercise intensity of high lactacidemia. on the basis of the present results, we can conclude that CS determined by a track cycling test seems to overestimate the intensity of the maximal lactate steady state for most subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to determine the reproducibility and validity of DIAGNOdent in detecting active and arrested caries lesions on free smooth surfaces. Volunteers were selected from state schools of Piracicaba, São Paulo, Brazil. Overall, 220 lesions were clinically examined. Two specially trained ('calibrated') examiners performed both clinical and laser evaluations independently, and after a 1-week interval, the examinations were repeated, the intra-examiner agreement for the laser evaluation was substantial (kappa(ex1) = 0.79, kappa(ex2) = 0.71). There was almost perfect agreement between the two examiners for the clinical examination (kappa(ex1) = 0.95, kappa(ex2) = 0.85). The inter-examiner agreement showed substantial reproducibility (kappa = 0.77) for the laser examination and almost perfect agreement (kappa = 0.85) for the clinical evaluation. The validation criterion was the clinical examination of white spots, recorded as active or arrested. The sensitivity was 0.72 and the specificity was 0.73, which indicates that the DIAGNOdent was a good auxiliary method for detecting incipient caries lesions on free smooth surfaces. The utilization of both methods can improve the efficacy of caries diagnosis. Copyright (C) 2002 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reproducibility and validity of self-perceived periodontal, dental, and temporomandibular joint (TMJ) conditions were investigated. A questionnaire was applied in interview to 200 adults aged from 35 to 44, who were attending as casual patients at Araraquara School of Dentistry, Sauo Paulo State University, Sauo Paulo, Brazil. Clinical examination was based on the guidelines of the World Health Organization manual. The interview and the clinical examination were performed in two occasions, by a calibrated examiner. Reproducibility and validity were, respectively, verified by kappa statistics (kappa) and sensitivity (Sen) and specificity (Spec) values, having clinical examination as the validation criterion. The results showed an almost perfect agreement for self-perceived TMJ (kappa=0.85) and periodontal conditions (kappa=0.81), and it was substantial for dental condition (kappa=0.69). Reproducibility according to clinical examination showed good results (kappa=0.73 for CPI index, kappa=0.96 for dental caries, and kappa=0.74 for TMJ conditions). Sensitivity and specificity values were higher for self-perceived dental (Sen=0.84, Spec=1.0) and TMJ conditions (Sen=1.0, Spec=0.8). With regard to periodontal condition, specificity was low (0.43), although sensitivity was very high (1.0). Self-perceived oral health was reliable for the examined conditions. Validity was good to detect dental conditions and TMJ disorders, and it was more sensitive than specific to detect the presence of periodontal disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - the aim of this study was to analyze the validity of the critical speed (CS) to determine the speed corresponding to 4 mmol 1(-1) of blood lactate (S4) and the speed in a 30 min test (S30min) of swimmers aged 10-15 years.Synthesis of facts - CS, S4 and S30min were determined in 12 swimmers (eight boys and four girls) divided into two groups: 10-12 years and 13-15 years.Conclusion - CS was a good predictor of aerobic performance (S30min) independent of the chronological age, providing practical information about the aerobic performance state of young swimmers. (C) 2002, Editions scientifiques et medicates, Elsevier SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To validate hysteroscopic view with histology in cases of endometrial hyperplasia and cancer in patients with abnormal uterine bleeding (AUB)DESIGN: Retrospective study.(Canadian Task Force classification II-3).SETTING: University teaching hospitals in Rio de Janeiro and São Paulo, and private office in Rio de Janeiro.PATIENTS: Four thousand and fifty-four patients with AUB in whom hysteroscopic views were complete and the histologic result was conclusive.INTERVENTION: Four thousand and fifty-four office hysteroscopies with complete views and conclusive histologic results. The material for histologic examination was obtained through biopsy of the lesion in an outpatient unit or through the resection of the entire lesion in patients who underwent surgery. Histology was considered the gold standard and compared with the hysteroscopic view.MEASUREMENTS AND MAIN RESULTS: In the histology of the 4054 examinations, 613 (15.2%) were endometrial hyperplasia, and 105 (2.6%) were endometrial cancer. The most frequent hysteroscopic finding was endometrial polyps (31.2%). In endometrial hyperplasia, the sensitivity of the hysteroscopic view was 56.3% (95% CI 52.21-60.2%), specificity was 89.1% (95% CI 88.0%-90.1%), positive predictive value (PPV) was 48.0% (95% CI 44.3%-51.7%), negative predictive value (NPV) was 92.0% (95% Cl 90.1%-92.9%), and accuracy was 72.7% (95% CI 70.7%-74.7%). Accuracy was defined as the proportion of correct results among the hysteroscopic examinations. In endometrial cancer, the sensitivity of the hysteroscopic view was 80.0% (95% Cl 71.1%-87.2%), specificity was 99.5% (95% CI 99.2%-99.7%), PPV was 81.5% (95% Cl 72.7%-88.5%), NPV was 99.5% (95% CI 99.2%-99.7%), and accuracy was 89.8% (95% CI, 85.9%-93.6%). In the 814 patients (20.0%) in whom the hysteroscopic view was normal, there were no false negatives for endometrial cancer; however, there were 37 (4.5%) false negatives for endometrial hyperplasia. In the histologic cases of endometrial cancer, 101 (96.2%) hysteroscopic views were compatible with cancer or hyperplasia (80.0% and 16.2%, respectively). Ninety-seven out of 103 hysteroscopic views with cancer findings (94.2%) had histologic diagnosis of cancer or hyperplasia (81.5% and 12.6%, respectively).CONCLUSION: It seems that even in face of good validity of hysteroscopic view for endometrial hyperplasia and cancer, histologic study is mandatory in the presence of any lesion as the hysteroscopic view cannot completely replace the histologic study in patients with AUB. (C) 2006 AAGL. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internet data collection is becoming increasingly popular in all research fields dealing with human perceptions, behaviors and opinions. Advantages of internet data collection, when compared to the traditional paper-and-pencil format, include reduced costs, automatic database creation, and the absence of researcher-related bias effects, such as availability and complete anonymity. However, the validity and reliability of internet gathered data must be established, in comparison to the usual paper-and-pencil accepted formats, before an inferential analysis can be done. In this study, we compared questionnaire data gathered from the internet with that from the traditional paper-and-pencil in a sample of college students. The questionnaires used were the Maslach Burnout Inventory - Student Survey (MBI-SS), the Oldenburg Burnout Inventory (OBI-SS) and the Copenhagen Burnout Inventory (CBI-SS). Data was gathered through a within-subject cross randomized and counterbalanced design, on both internet and paper-and-pencil formats. The results showed no interference in the application order, and a good reliability for both formats. However, concordance between answers was generally higher in the paper-and-pencil format than on the internet. The factorial structure was invariant in the three burnout inventories. Data gathered in this study supports the Internet as a convenient, user-friendly, comfortable and secure data gathering method which does not affect the accepted factorial structures existent in the paper format of the three burnout inventories used. (C) 2011 Elsevier Ltd. All rights reserved.