971 resultados para Portal vein thrombosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the stability over time of the individually defined interval of intravitreal ranibizumab injection (IVR) for the treatment of recurrent macular edema (ME) in central retinal vein occlusion (CRVO). Patients and Methods: A case series of treatment naïve patients followed in the Jules Gonin Eye Hospital for macular edema due to central retinal vein occlusion is presented. Patients were treated monthly with IVR until complete absence of fluid on qualitative SD-OCT with a minimum of 5 monthly IVR. Thereafter, they were followed according to a modified treat and extend regimen (mTER). Results: Twelve eyes (12 patients) with ME due to CRVO were included. The mean follow-up period was 31.3 months. Analysis showed that best corrected visual acuity (BCVA), central macular thickness and qualitative spectral domain optical coherence tomography (SD-OCT) showed comparable results under monthly interval, after titration of an individualized interval and when performed in a series. 78 % of treating intervals were within ± 2 weeks of the first individually adjusted interval. The mean first defined interval was 4.3 weeks and the mean interval over time was 5.5 weeks (p = 0.003). There was a trend towards longer interval over time. Conclusion: The adjusted interval of retreatment of patients with ME due to CRVO showed a high stability with a trend toward longer duration over time. An mTER regimen seems to be valuable to follow patients with ME with good stabilization of VA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although randomized clinical trials (RCTs) are considered the gold standard of evidence, their reporting is often suboptimal. Trial registries have the potential to contribute important methodologic information for critical appraisal of study results. Methods and Findings: The objective of the study was to evaluate the reporting of key methodologic study characteristics in trial registries. We identified a random sample (n = 265) of actively recruiting RCTs using the World Health Organization International Clinical Trials Registry Platform (ICTRP) search portal in 2008. We assessed the reporting of relevant domains from the Cochrane Collaboration’s ‘Risk of bias’ tool and other key methodological aspects. Our primary outcomes were the proportion of registry records with adequate reporting of random sequence generation, allocation concealment, blinding, and trial outcomes. Two reviewers independently assessed each record. Weighted overall proportions in the ICTRP search portal for adequate reporting of sequence generation, allocation concealment, blinding (including and excluding open label RCT) and primary outcomes were 5.7% (95% CI 3.0–8.4%), 1.4% (0–2.8%), 41% (35–47%), 8.4% (4.1–13%), and 66% (60–72%), respectively. The proportion of adequately reported RCTs was higher for registries that used specific methodological fields for describing methods of randomization and allocation concealment compared to registries that did not. Concerning other key methodological aspects, weighted overall proportions of RCTs with adequately reported items were as follows: eligibility criteria (81%), secondary outcomes (46%), harm (5%) follow-up duration (62%), description of the interventions (53%) and sample size calculation (1%). Conclusions: Trial registries currently contain limited methodologic information about registered RCTs. In order to permit adequate critical appraisal of trial results reported in journals and registries, trial registries should consider requesting details on key RCT methods to complement journal publications. Full protocols remain the most comprehensive source of methodologic information and should be made publicly available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Severe acute refractory respiratory failure is considered a life-threatening situation, with a high mortality of 40 to 60%. When conservative oxygenation methods fail, a lifesaving measure is the introduction of extracorporeal membrane oxygenation (ECMO). Venovenous ECMO (VV-ECMO) is a preferred modality of support for patients with refractory acute respiratory failure. Specifically, bicaval VV-ECMO is a well-recognized and validated therapy, where single or double periphery venous access is used for the insertion of two differently sized cannulas in order to achieve adequate blood oxygenation. Compared to venoarterial ECMO, in VV-ECMO, the rate of complications, such as thrombosis, bleeding, infection and ischemic events, is lower. On the other hand, the size and insertion location is an obstacle to patient mobilization. This is a considerable problem for patients where the time interval for lung recovery and the bridge to the transplantation is prolonged. To address this issue, a dual-lumen, single venovenous cannula was introduced. Here, by insertion of one single catheter in one target vessel, in a majority of cases in the right internal jugular vein, satisfactory oxygenation of the patient is achieved. In this form, the instituted VV-ECMO enables patient mobility, better physical rehabilitation and facilitates pulmonary extubation and toilet. However, relatively early, after the first short-term reports were published, a relatively high complication rate became evident. In the recent literature, the complication rate using actual commercially available double-lumen venovenous cannula ranges between 5 and 30%. These cases were mostly conjoined to the implantation phase or the early postoperative phase and vary between right heart perforation to migration of the cannula. This review focuses on complications allied to commercially available dual-lumen, single, venovenous cannula implantation, pointing out the critical segments of the implantation process and analyzing the structure of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elektroniset finanssipalvelut, erityisesti Internetin kautta käytettynä, on kasvava alue. Elektronisten finanssipalveluiden tarjoajan tulee pystyä tarjoamaan laaja käytettävyys kaikkien kanavien kautta. Laajan käytettävyyden avulla asiakas voi valita haluamansa kanavan haluamanaan aikana. Palveluntarjoajalla tulee olla joustava arkkitehtuuri pystyäkseen tukemaan asiakkaiden muuttuvia vaatimuksia. Joustavalla arkkitehtuurilla päätelaitteeseen mukautuminen on mahdollista ja näin palveluntarjoaja pystyy tarjoamaan tuen monille eri päätelaitteille ja teknologioille helposti ja nopeasti. Diplomityö keskittyy tutkimaan mahdollisuutta monen kanavan tukeen ja päätelaitteeseen mukautumista Nordean tulevassa finanssiportaaliratkaisussa. Tämä pitäisi olla mahdollista uuden arkkitehtuurin kanssa, jonka TietoEnator on toteuttanut yhteistyössä Nordean kanssa. Sivujen rakenteen uudelleenjärjestelyillä saatiin hyviä tuloksia. Nykyisestä arkkitehtuurissa löydettiin myös puutteita ja jäljelle jäi avoimia kysymyksiä, jotka kirjattiin ylös. On selvästi nähtävissä, että tehokas päätelaitteeseen mukautuminen ja tuki monelle kanavalle tuo hyötyjä sekä pankille että asiakkaalle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tietojohtaminen on osoittautunut nykypäivänä organisaatioiden yhdeksi suurimmaksi haasteeksi. Haasteena ei vain ole se tiedon määrä mitä tulisi hallita, vaan pikemminkin tiedonhallinta toimii yritykselle kilpailuetuna globaalissa yritysmaailmassa. Tämän työn tavoitteena on tutkia yritysportaalin soveltuvuutta tiedonhallintaan globaalissa metsäteollisuusyrityksessä. Lisäksi tavoitteena on selvittää portaalin sovittamista kullekin käyttäjäryhmälle case yrityksessä. Työn teoriaosassa on käsitelty tiedonhallinnan monimuotoisuutta ja vaikeutta kuvata sitä yksiselitteisesti. Lisäksi käyttäjäryhmien ja käyttäjäprofiilien määrittämiseen vaikuttavia seikkoja on selvitetty tässä osassa. Empiirinen osa käsittelee case-yritystä ja sen suhdetta tiedonhallintaan sekä tämän kaltaisen tiedonhallinnan työvälineen käyttöön. Työstä saatujen tulosten perusteella voidaan todeta yritysportaalin soveltuvan hyvin tiedonhallintaan monimutkaisessakin yrityksessä. Portaali muuttaa yrityksen liiketoimintaprosesseja läpinäkyvämmiksi, kun bisneskriittistä tietoa tarjotaan yhdessä paikassa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modem software development requires quick results and excellent quality, which leads to high demand for reusability in design and implementation of software components. The purpose of this thesis was to design and implement a reusable framework for portal front ends, including common portal features, such as authentication and authorization. The aim was also to evaluate frameworks as components of reuse and compare them to other reuse techniques. As the result of this thesis, a goo'd picture of framework's life cycle, problem domain and the actual implementation process of the framework, was obtained. It was also found out that frameworks fit well to solve recurrent and similar problems in a restricted problem domain. The outcome of this thesis was a prototype of a generic framework and an example application built on it. The implemented framework offered an abstract base for the portal front ends, using object-oriented methods and wellknown design patterns. The example application demonstrated the speed and ease of the application development based on the application frameworks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cirrhosis is the final stage of most of chronic liver diseases, and is almost invariably complicated by portal hypertension, which is the most important cause of morbidity and mortality in these patients. This review will focus on the non-invasive methods currently used in clinical practice for diagnosing liver cirrhosis and portal hypertension. The first-line techniques include physical examination, laboratory parameters, transient elastography and Doppler-US. More sophisticated imaging methods which are less commonly employed are CT scan and MRI, and new technologies which are currently under evaluation are MR elastography and acoustic radiation force imaging (ARFI). Even if none of them can replace the invasive measurement of hepatic venous pressure gradient and the endoscopic screening of gastroesophageal varices, they notably facilitate the clinical management of patients with cirrhosis and portal hypertension, and provide valuable prognostic information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous bypass grafts often fail following arterial implantation due to excessive smooth muscle cells (VSMC) proliferation and consequent intimal hyperplasia (IH). Intercellular communication mediated by Connexins (Cx) regulates differentiation, growth and proliferation in various cell types. Microarray analysis of vein grafts in a model of bilateral rabbit jugular vein graft revealed Cx43 as an early upregulated gene. Additional experiments conducted using an ex-vivo human saphenous veins perfusion system (EVPS) confirmed that Cx43 was rapidly increased in human veins subjected ex-vivo to arterial hemodynamics. Cx43 knock-down by RNA interference, or adenoviral-mediated overexpression, respectively inhibited or stimulated the proliferation of primary human VSMC in vitro. Furthermore, Cx blockade with carbenoxolone or the specific Cx43 inhibitory peptide 43gap26 prevented the burst in myointimal proliferation and IH formation in human saphenous veins. Our data demonstrated that Cx43 controls proliferation and the formation of IH after arterial engraftment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ultra-sonografia e o Doppler representaram grande marco no diagnóstico da hipertensão portal. Este fato decorre do aspecto não-invasivo destes métodos, possibilitando o estudo do fígado, do baço e da circulação esplâncnica. Neste artigo os autores discutem alguns aspectos importantes avaliados pela ultra-sonografia e pelo Doppler na avaliação da hipertensão portal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente, la mayoría de revistas científicas se distribuyen a través de portales que recopilan gran cantidad de títulos y facilitan el acceso a ellos desde un único sitio web. El propósito de Temaria es poner a disposición de bibliotecarios y documentalistas todas las revistas de su área que se publican en formato digital, y hacerlo a partir de un sistema uniforme de descripción e indización.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: A cirrose hepática causa alterações acentuadas na circulação esplâncnica. Com o objetivo de investigar as alterações hemodinâmicas na velocidade do fluxo da veia porta, realizamos estudos com eco-Doppler em pacientes com cirrose hepática em estágio final antes, durante e após transplante hepático ortotópico (THO). MATERIAIS E MÉTODOS: Cinqüenta e quatro pacientes submetidos a THO e eco-Doppler intra-operatório foram avaliados prospectivamente, entre janeiro de 2002 e julho de 2003. Dezessete pacientes foram excluídos devido a dados incompletos relacionados a dificuldades técnicas para obter medidas ou morte prematura. Os 37 pacientes incluídos na análise tinham cirrose hepática associada principalmente a infecção pelo vírus da hepatite C e doença alcoólica. Todos os pacientes foram submetidos ao eco-Doppler imediatamente antes do THO, no período intra-operatório após a reperfusão do enxerto e no primeiro e sétimo dias do pós-operatório. A velocidade média do fluxo foi medida no tronco, ramo direito e ramo esquerdo da veia porta. A análise estatística foi realizada utilizando-se o teste t pareado e as diferenças foram consideradas significantes se p < 0,05. RESULTADOS: A velocidade média observada no pré-THO foi de 16.0 cm/s. As medidas intra-operatórias, realizadas minutos após a reperfusão do enxerto, mostraram aumento na velocidade do fluxo da veia porta para 84.09 cm/s. A velocidade do fluxo da veia porta foi de 71,0 cm/s e 58,5 cm/s no primeiro e sétimo dias do pós-operatório, respectivamente. As velocidades obtidas no intra e pós-operatório foram significativamente maiores do que no pré-THO (p < 0,001). No sétimo dia do pós-operatório, a velocidade média diminuiu significativamente em comparação aos valores do intra-operatório (p < 0.05). CONCLUSÃO: Nos transplantes hepáticos ocorre aumento significativo da velocidade média de fluxo da veia porta imediatamente após a reperfusão do enxerto em comparação aos valores pré-THO. De maneira semelhante, após esse pico máximo parece ocorrer redução significativa e progressiva na velocidade média de fluxo, atingindo valores próximos da normalidade no sétimo dia do pós-operatório.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a eficácia do TIPS (transjugular intrahepatic portosystemic shunt) para tratar as complicações clínicas em pacientes com hipertensão portal. MATERIAIS E MÉTODOS: Quarenta e quatro pacientes, sendo 30 do sexo masculino e 14 do feminino e com idade média de 52 anos foram analisados. A indicação para realização de TIPS foi hemorragia gastrintestinal em 28 e ascite refratária em 16. Houve 7 pacientes Child-Pugh A, 24 Child-Pugh B e 11 Child-Pugh C. RESULTADOS: O TIPS foi realizado com sucesso em todos os pacientes (100%), verificando-se queda do gradiente pressórico porto-sistêmico médio de 49,69% (de 18,98 mmHg para 9,55 mmHg). Comprovou-se melhora clínica em 35 pacientes (79,55%). A mortalidade pós-operatóriaia foi de 13,64%, sendo mais incidente nos pacientes Child-Pugh C (45,45%). Os fatores mais relevantes de mau prognóstico foram o aumento da bilirrubina e do nível de creatinina. A sobrevida média de pacientes Child-Pugh A foi de 11,5 meses, nos Child-Pugh B foi de 10,97 meses e nos Child-Pugh C foi de apenas 5,9 meses. Foram observadas complicações em nove casos (20,44%). CONCLUSÃO: O TIPS é eficiente para reduzir a pressão portal. As complicações e a morbi-mortalidade relacionadas com o procedimento podem ser consideradas aceitáveis. A mortalidade foi influenciada por alguns fatores clínicos, tais como classe Child-Pugh C e elevação dos níveis séricos de bilirrubina e creatinina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estudar os índices de impedância - índices de resistência (IR) e pulsatilidade (IP) - da artéria esplênica em pacientes com hepatopatia crônica. MATERIAIS E MÉTODOS: Foram estudados, prospectivamente, 42 pacientes com cirrose hepática e 21 pacientes com hepatite crônica. RESULTADOS: Foi observado que, nos pacientes com cirrose, ambos os índices estiveram elevados (IR = 0,63 ± 0,08 e IP = 1,02 ± 0,22) em comparação com os pacientes com hepatite crônica (IR = 0,58 ± 0,06 e IP = 0,89 ± 0,15) e os indivíduos do grupo controle (IR = 0,57 ± 0,04 e IP = 0,87 ± 0,11). Os cirróticos com evidência de circulação colateral à ultra-sonografia apresentaram, no entanto, menores índices de resistência (IR = 0,60 ± 0,08) em comparação com os cirróticos sem circulação colateral (IR = 0,65 ± 0,07), possivelmente devido ao shunt portossistêmico provocado pelos vasos colaterais. Não houve diferença significativa dos índices entre pacientes com e sem varizes esofagianas. CONCLUSÃO: O trabalho demonstrou que os índices de impedância da artéria esplênica podem ser úteis na avaliação de pacientes com hepatopatia crônica e hipertensão portal, contribuindo com dados adicionais à ultra-sonografia com eco-Doppler colorido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Medir a sensibilidade e a reprodutibilidade da ultra-sonografia na detecção de nódulos sideróticos esplênicos em pacientes esquistossomóticos, tendo a ressonância magnética como padrão de referência. MATERIAIS E MÉTODOS: Na primeira fase do trabalho, 21 pacientes portadores de esquistossomose na forma hepatoesplênica com diagnóstico de nódulos sideróticos à ressonância magnética foram submetidos a avaliação ultra-sonográfica para a determinação da sensibilidade do método. Na segunda fase, com o objetivo de avaliar a reprodutibilidade da ultra-sonografia na detecção e na quantificação de nódulos sideróticos (A: 1-5 nódulos; B: 6-20 nódulos; C: mais de 20 nódulos), outros 30 pacientes esquistossomóticos foram submetidos a avaliação ultra-sonográfica de forma cega e independente por dois observadores. A reprodutibilidade foi medida por meio da concordância entre os observadores e do teste kappa. RESULTADOS: A sensibilidade da ultra-sonografia foi de 95,2% (intervalo de confiança a 95% [77,3%; 99,2%]). A concordância entre ultra-sonografia e ressonância magnética para a detecção de nódulos sideróticos foi de 96,7% (intervalo de confiança a 95% [82,8%; 99,9%]). Para a classificação dos nódulos conforme a sua quantificação, o índice kappa demonstrou concordância interobservador substancial (kappa = 0,67). CONCLUSÃO: A ultra-sonografia é um método que apresenta elevada sensibilidade e boa precisão para a avaliação de nódulos sideróticos esplênicos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The left brachiocephalic vein occasionally follows an aberrant course. It is usually associated with congenital cardiac anomaly. We present a case of anomalous left brachiocephalic vein which followed a sub aortic course, with no cardiac abnormality. Multi detector computed tomography is very useful in accurate diagnosis of this condition and prevents any further investigation in cases of isolated abnormalities.