971 resultados para Perfecto Simple
Resumo:
The use of an acid violet 7 (AV7) smart ink to assess the activity of photocatalytic paint is demonstrated. A linear correlation is established between the change in oxidized dye concentration, as measured by diffuse reflectance, and the change in the green component of the RGB color values, obtained using a portable hand-held scanner, suggesting that such tests can be monitored easily using an inexpensive piece of hand-held office equipment, as opposed to an expensive lab-based instrument, such as a diffuse reflectance UV/vis spectrophotometer. The bleaching of the AV7 follows first order kinetics, at a rate that is linearly dependent upon the UVA irradiance (0.30–3.26 mW cm–2). A comparison of relative rate of bleaching of the AV7 ink with the relative rate of removal of NOx, as determined using the ISO test (ISO 22197-1:2007), established a linear relationship between the two sets of results and the relevance of this correlation is discussed briefly.
Resumo:
Two different mesoporous films of TiO2 were coated onto a QCM disc and fired at 450o C for 30 min. The first film was derived from a sol-gel paste that was popular in the early days of dye-sensitised solar cell, i.e. dssc, research, a TiO2(sg) film. The other was a commercial colloidal paste used to make examples of the current dssc cell; a TiO2(ds) film. A QCM was used to determine the mass of the TiO2 film deposited on each disc and the increase in the mass of the film when immersed in water/glycerol solutions with wt% values spanning the range 0-70%. The results of this work reveal that with both TiO2 mesoporous films the solution fills the film's pores and acts as a rigid mass, thereby allowing the porosity of each film to be calculated as: 59.1% and 71.6% for the TiO2(sg) and TiO2(ds) films, respectively. These results, coupled with surface area data, allowed the pore radii of the two films to be calculated as: 9.6 and 17.8 nm, respectively. This method is then simplified further, to just a few frequency measurements in water and only air to reveal the same porosity values. The value of the latter ‘one point’ method for making porosity measurements is discussed briefly.
Resumo:
We present a simple model for a component of the radiolytic production of any chemical species due to electron emission from irradiated nanoparticles (NPs) in a liquid environment, provided the expression for the G value for product formation is known and is reasonably well characterized by a linear dependence on beam energy. This model takes nanoparticle size, composition, density and a number of other readily available parameters (such as X-ray and electron attenuation data) as inputs and therefore allows for the ready determination of this contribution. Several approximations are used, thus this model provides an upper limit to the yield of chemical species due to electron emission, rather than a distinct value, and this upper limit is compared with experimental results. After the general model is developed we provide details of its application to the generation of HO(•) through irradiation of gold nanoparticles (AuNPs), a potentially important process in nanoparticle-based enhancement of radiotherapy. This model has been constructed with the intention of making it accessible to other researchers who wish to estimate chemical yields through this process, and is shown to be applicable to NPs of single elements and mixtures. The model can be applied without the need to develop additional skills (such as using a Monte Carlo toolkit), providing a fast and straightforward method of estimating chemical yields. A simple framework for determining the HO(•) yield for different NP sizes at constant NP concentration and initial photon energy is also presented.
Resumo:
OBJECTIVE:
To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.
DESIGN:
Clinic-based validation and interobserver reliability trial.
PARTICIPANTS:
Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.
INTERVENTION:
In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).
MAIN OUTCOME MEASURES:
Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.
RESULTS:
In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).
CONCLUSION:
Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.
Resumo:
Few models can explain Mach bands (Pessoa, 1996 Vision Research 36 3205-3227) . Our own employs multiscale line and edge coding by simple and complex cells. Lines are interpreted by Gaussian functions, edges by bipolar, Gaussian-truncated errorfunctions. Widths of these functions are coupled to the scales of the underlying cells and the amplitudes are determined by their responses.
Resumo:
A syntactical brightness model based on a multiscale line and edge representation obtained by a set of anisotropic Gabor filters is quite complex (du Buf and Fischer, 1995 Optical Engineering 34 1900-1911). Although only tested in 1-D, it was shown to yield correct brightness effects for many patterns.
Resumo:
Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.
Resumo:
The Janssen-Cilag proposal for a risk-sharing agreement regarding bortezomib received a welcome signal from NICE. The Office of Fair Trading report included risk-sharing agreements as an available tool for the National Health Service. Nonetheless, recent discussions have somewhat neglected the economic fundamentals underlying risk-sharing agreements. We argue here that risk-sharing agreements, although attractive due to the principle of paying by results, also entail risks. Too many patients may be put under treatment even with a low success probability. Prices are likely to be adjusted upward, in anticipation of future risk-sharing agreements between the pharmaceutical company and the third-party payer. An available instrument is a verification cost per patient treated, which allows obtaining the first-best allocation of patients to the new treatment, under the risk sharing agreement. Overall, the welfare effects of risk-sharing agreements are ambiguous, and care must be taken with their use.