944 resultados para Passive vibration damping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the Expectation Maximization algorithm (EM) applied to operational modal analysis of structures. The EM algorithm is a general-purpose method for maximum likelihood estimation (MLE) that in this work is used to estimate state space models. As it is well known, the MLE enjoys some optimal properties from a statistical point of view, which make it very attractive in practice. However, the EM algorithm has two main drawbacks: its slow convergence and the dependence of the solution on the initial values used. This paper proposes two different strategies to choose initial values for the EM algorithm when used for operational modal analysis: to begin with the parameters estimated by Stochastic Subspace Identification method (SSI) and to start using random points. The effectiveness of the proposed identification method has been evaluated through numerical simulation and measured vibration data in the context of a benchmark problem. Modal parameters (natural frequencies, damping ratios and mode shapes) of the benchmark structure have been estimated using SSI and the EM algorithm. On the whole, the results show that the application of the EM algorithm starting from the solution given by SSI is very useful to identify the vibration modes of a structure, discarding the spurious modes that appear in high order models and discovering other hidden modes. Similar results are obtained using random starting values, although this strategy allows us to analyze the solution of several starting points what overcome the dependence on the initial values used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During September 2011, post-emergence damping off of Swiss chard (Beta vulgaris subsp. cicla L.) was observed in a greenhouse in Villa del Prado (Spain). About 20% of the seedlings showed damping off symptoms. Lesions were initially water soaked, dark brown necrosis of crown tissue, irregular in shape and sunken in appearance on large plants, causing the infected seedlings to collapse and eventually die. Rhizoctonia solani was isolated consistently from symptomatic plants. After morphological and molecular identification of the isolates, pathogenicity was tested by placing agar plugs of four isolates adjacent to the stem at the three or four true leaf stage. In inoculated plants, brown crown and stem necrosis occurred while control plants did not show disease symptoms. Pathogenicity using non-germinated seeds was also tested. All four isolates produced extensive damping off when inoculated on non-germinated seeds. To our knowledge, this is the first report of damping off of Swiss chard caused by R. solani in Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flexural vibration of a homogeneous isotropic linearly elastic cylinder of any aspect ratio is analysed in this paper. Natural frequencies of a cylinder under uniformly distributed axial loads acting on its bases are calculated numerically by the Ritz method with terms of power series in the coordinate directions as approximating functions. The effect of axial loads on the flexural vibration cannot be described by applying infinitesimal strain theory, therefore, geometrically nonlinear strain–displacement relations with second-order terms are considered here. The natural frequencies of free–free, clamped–clamped, and sliding–sliding cylinders subjected to axial loads are calculated using the proposed three-dimensional Ritz approach and are compared with those obtained with the finite element method and the Bernoulli–Euler theory. Different experiments with cylinders axially compressed by a hydraulic press are carried out and the experimental results for the lowest flexural frequency are compared with the numerical results. An approach based on the Ritz formulation is proposed for the flexural vibration of a cylinder between the platens of the press with constraints varying with the intensity of the compression. The results show that for low compressions the cylinder behaves similarly to a sliding–sliding cylinder, whereas for high compressions the cylinder vibrates as a clamped–clamped one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase of orbital debris and the consequent proliferation of smaller objects through fragmentation are driving the need for mitigation strategies. The issue is how to deorbit the satellite with an efficient system that does not impair drastically the propellant budget of the satellite and, consequently, reduces its operating life. We have been investigating, in the framework of a European-Community-funded project, a passive system that makes use of an electrodynamics tether to deorbit a satellite through Lorentz forces. The deorbiting system will be carried by the satellite itself at launch and deployed from the satellite at the end of its life. From that moment onward the system operates passively without requiring any intervention from the satellite itself. The paper summarizes the results of the analysis carried out to show the deorbiting performance of the system starting from different orbital altitudes and inclinations for a reference satellite mass. Results can be easily scaled to other satellite masses. The results have been obtained by using a high-fidelity computer model that uses the latest environmental routines for magnetic field, ionospheric density, atmospheric density and a gravity field model. The tether dynamics is modelled by considering all the main aspects of a real system as the tether flexibility and its temperature-dependent electrical conductivity. Temperature variations are computed by including all the major external and internal input fluxes and the thermal flux emitted from the tether. The results shows that a relatively compact and light system can carry out the complete deorbit of a relatively large satellite in a time ranging from a month to less than a year starting from high LEO with the best performance occurring at low orbital inclinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

System identification deals with the problem of building mathematical models of dynamical systems based on observed data from the system" [1]. In the context of civil engineering, the system refers to a large scale structure such as a building, bridge, or an offshore structure, and identification mostly involves the determination of modal parameters (the natural frequencies, damping ratios, and mode shapes). This paper presents some modal identification results obtained using a state-of-the-art time domain system identification method (data-driven stochastic subspace algorithms [2]) applied to the output-only data measured in a steel arch bridge. First, a three dimensional finite element model was developed for the numerical analysis of the structure using ANSYS. Modal analysis was carried out and modal parameters were extracted in the frequency range of interest, 0-10 Hz. The results obtained from the finite element modal analysis were used to determine the location of the sensors. After that, ambient vibration tests were conducted during April 23-24, 2009. The response of the structure was measured using eight accelerometers. Two stations of three sensors were formed (triaxial stations). These sensors were held stationary for reference during the test. The two remaining sensors were placed at the different measurement points along the bridge deck, in which only vertical and transversal measurements were conducted (biaxial stations). Point estimate and interval estimate have been carried out in the state space model using these ambient vibration measurements. In the case of parametric models (like state space), the dynamic behaviour of a system is described using mathematical models. Then, mathematical relationships can be established between modal parameters and estimated point parameters (thus, it is common to use experimental modal analysis as a synonym for system identification). Stable modal parameters are found using a stabilization diagram. Furthermore, this paper proposes a method for assessing the precision of estimates of the parameters of state-space models (confidence interval). This approach employs the nonparametric bootstrap procedure [3] and is applied to subspace parameter estimation algorithm. Using bootstrap results, a plot similar to a stabilization diagram is developed. These graphics differentiate system modes from spurious noise modes for a given order system. Additionally, using the modal assurance criterion, the experimental modes obtained have been compared with those evaluated from a finite element analysis. A quite good agreement between numerical and experimental results is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cutoff frequencies of an EMI filter are normally given by the noise attenuation requirements the filter has to fulfill. In order to select the component values of the filter elements, i.e. inductances and capacitances, an additional design criterium is needed. In this paper the effect of the EMI filter input and output impedances are considered. The input impedance influences the filters effect on the system displacement power factor and the output impedance plays a key role in the system stability. The effect of filter element values, the number of filter stages as well as additional damping networks are considered and a design procedure is provided. For this analysis a two-port description of the input filters employing ABCD-parameters is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A notorious advantage of wireless transmission is a significant reduction and simplification in wiring and harness. There are a lot of applications of wireless systems, but in many occasions sensor nodes require a specific housing to protect the electronics from hush environmental conditions. Nowadays the information is scarce and nonspecific on the dynamic behaviour of WSN and RFID. Therefore the purpose of this study is to evaluate the dynamic behaviour of the sensors. A series of trials were designed and performed covering temperature steps between cold room (5 °C), room temperature (23 °C) and heated environment (35 °C). As sensor nodes: three Crossbow motes, a surface mounted Nlaza module (with sensor Sensirion located on the motherboard), an aerial mounted Nlaza where the Sensirion sensor stayed at the end of a cable), and four tags RFID Turbo Tag (T700 model with and without housing), and 702-B (with and without housing). To assess the dynamic behaviour a first order response approach is used and fitted with dedicated optimization tools programmed in Matlab that allow extracting the time response (?) and corresponding determination coefficient (r2) with regard to experimental data. The shorter response time (20.9 s) is found for the uncoated T 700 tag which encapsulated version provides a significantly higher response (107.2 s). The highest ? corresponds to the Crossbow modules (144.4 s), followed by the surface mounted Nlaza module (288.1 s), while the module with aerial mounted sensor gives a response certainly close above to the T700 without coating (42.8 s). As a conclusion, the dynamic response of temperature sensors within wireless and RFID nodes is dramatically influenced by the way they are housed (to protect them from the environment) as well as by the heat released by the node electronics itself; its characterization is basic to allow monitoring of high rate temperature changes and to certify the cold chain. Besides the time to rise and to recover is significantly different being mostly higher for the latter than for the former.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four-dimensional flow in the phase space of three amplitudes of circularly polarized Alfven waves and one relative phase, resulting from a resonant three-wave truncation of the derivative nonlinear Schrödinger equation, has been analyzed; wave 1 is linearly unstable with growth rate , and waves 2 and 3 are stable with damping 2 and 3, respectively. The dependence of gross dynamical features on the damping model as characterized by the relation between damping and wave-vector ratios, 2 /3, k2 /k3, and the polarization of the waves, is discussed; two damping models, Landau k and resistive k2, are studied in depth. Very complex dynamics, such as multiple blue sky catastrophes and chaotic attractors arising from Feigenbaum sequences, and explosive bifurcations involving Intermittency-I chaos, are shown to be associated with the existence and loss of stability of certain fixed point P of the flow. Independently of the damping model, P may only exist as against flow contraction just requiring.In the case of right-hand RH polarization, point P may exist for all models other than Landau damping; for the resistive model, P may exist for RH polarization only if 2+3/2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main obstacles to the widespread adoption of quantum cryptography has been the difficulty of integration into standard optical networks, largely due to the tremendous difference in power of classical signals compared with the single quantum used for quantum key distribution. This makes the technology expensive and hard to deploy. In this letter, we show an easy and straightforward integration method of quantum cryptography into optical access networks. In particular, we analyze how a quantum key distribution system can be seamlessly integrated in a standard access network based on the passive optical and time division multiplexing paradigms. The novelty of this proposal is based on the selective post-processing that allows for the distillation of secret keys avoiding the noise produced by other network users. Importantly, the proposal does not require the modification of the quantum or classical hardware specifications neither the use of any synchronization mechanism between the network and quantum cryptography devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the last two decades the topic of human induced vibration has attracted a lot of attention among civil engineering practitioners and academics alike. Usually this type of problem may be encountered in pedestrian footbridges or floors of paperless offices. Slender designs are becoming increasingly popular, and as a consequence, the importance of paying attention to vibration serviceability also increases. This paper resumes the results obtained from measurements taken at different points of an aluminium catwalk which is 6 m in length by 0.6 m in width. Measurements were carried out when subjecting the structure to different actions:1)Static test: a steel cylinder of 35 kg was placed in the middle of the catwalk; 2)Dynamic test: this test consists of exciting the structure with singles impulses; 3)Dynamic test: people walking on the catwalk. Identification of the mechanical properties of the structure is an achievement of the paper. Indirect methods were used to estimate properties including the support stiffness, the beam bending stiffness, the mass of the structure (using Rayleigh method and iterative matrix method), the natural frequency (using the time domain and frequency domain analysis) and the damping ratio (by calculating the logarithmic decrement). Experimental results and numerical predictions for the response of an aluminium catwalk subjected to walking loads have been compared. The damping of this light weight structure depends on the amplitude of vibration which complicates the tuning of a structural model. In the light of the results obtained it seems that the used walking load model is not appropriate as the predicted transient vibration values (TTVs) are much higher than the measured ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum cryptography in communications networks

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, Vortex-Induced Vibrations (VIVs) of a circular cylinder are analyzed as a potential source for energy harvesting. To this end, VIV is described by a one-degree-of-freedom model where fluid forces are introduced from experimental data from forced vibration tests. The influence of some influencing parameters, like the mass ratio m∗ or the mechanical damping ζ in the energy conversion factor is investigated. The analysis reveals that: (i) the maximum efficiency ηM is principally influenced by the mass-damping parameter m∗ζ and there is an optimum value of m∗ζ where ηM presents a maximum; (ii) the range of reduced velocities with significant efficiency is mainly governed by m∗, and (iii) it seems that encouraging high efficiency values can be achieved for high Reynolds numbers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crowd induced dynamic loading in large structures, such as gymnasiums or stadium, is usually modelled as a series of harmonic loads which are defined in terms of their Fourier coefficients. Different values of these coefficients that were obtained from full scale measurements can be found in codes. Recently, an alternative has been proposed, based on random generation of load time histories that take into account phase lag among individuals inside the crowd. This paper presents the testing done on a structure designed to be a gymnasium. Two series of dynamic test were performed on the gym slab. For the first test an electrodynamic shaker was placed at several locations and during the second one people located inside a marked area bounced and jumped guided by different metronome rates. A finite element model (FEM) is presented and a comparison of numerically predicted and experimentally observed vibration modes and frequencies has been used to assess its validity. The second group of measurements will be compared with predictions made using the FEM model and three alternatives for crowd induced load modelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cualquier estructura vibra según unas frecuencias propias definidas por sus parámetros modales (frecuencias naturales, amortiguamientos y formas modales). A través de las mediciones de la vibración en puntos clave de la estructura, los parámetros modales pueden ser estimados. En estructuras civiles, es difícil excitar una estructura de manera controlada, por lo tanto, las técnicas que implican la estimación de los parámetros modales sólo registrando su respuesta son de vital importancia para este tipo de estructuras. Esta técnica se conoce como Análisis Modal Operacional (OMA). La técnica del OMA no necesita excitar artificialmente la estructura, atendiendo únicamente a su comportamiento en servicio. La motivación para llevar a cabo pruebas de OMA surge en el campo de la Ingeniería Civil, debido a que excitar artificialmente con éxito grandes estructuras no sólo resulta difícil y costoso, sino que puede incluso dañarse la estructura. Su importancia reside en que el comportamiento global de una estructura está directamente relacionado con sus parámetros modales, y cualquier variación de rigidez, masa o condiciones de apoyo, aunque sean locales, quedan reflejadas en los parámetros modales. Por lo tanto, esta identificación puede integrarse en un sistema de vigilancia de la integridad estructural. La principal dificultad para el uso de los parámetros modales estimados mediante OMA son las incertidumbres asociadas a este proceso de estimación. Existen incertidumbres en el valor de los parámetros modales asociadas al proceso de cálculo (internos) y también asociadas a la influencia de los factores ambientales (externas), como es la temperatura. Este Trabajo Fin de Máster analiza estas dos fuentes de incertidumbre. Es decir, en primer lugar, para una estructura de laboratorio, se estudian y cuantifican las incertidumbres asociadas al programa de OMA utilizado. En segundo lugar, para una estructura en servicio (una pasarela de banda tesa), se estudian tanto el efecto del programa OMA como la influencia del factor ambiental en la estimación de los parámetros modales. Más concretamente, se ha propuesto un método para hacer un seguimiento de las frecuencias naturales de un mismo modo. Este método incluye un modelo de regresión lineal múltiple que permite eliminar la influencia de estos agentes externos. A structure vibrates according to some of its vibration modes, defined by their modal parameters (natural frequencies, damping ratios and modal shapes). Through the measurements of the vibration at key points of the structure, the modal parameters can be estimated. In civil engineering structures, it is difficult to excite structures in a controlled manner, thus, techniques involving output-only modal estimation are of vital importance for these structure. This techniques are known as Operational Modal Analysis (OMA). The OMA technique does not need to excite artificially the structure, this considers its behavior in service only. The motivation for carrying out OMA tests arises in the area of Civil Engineering, because successfully artificially excite large structures is difficult and expensive. It also may even damage the structure. The main goal is that the global behavior of a structure is directly related to their modal parameters, and any variation of stiffness, mass or support conditions, although it is local, is also reflected in the modal parameters. Therefore, this identification may be within a Structural Health Monitoring system. The main difficulty for using the modal parameters estimated by an OMA is the uncertainties associated to this estimation process. Thus, there are uncertainties in the value of the modal parameters associated to the computing process (internal) and the influence of environmental factors (external), such as the temperature. This Master’s Thesis analyzes these two sources of uncertainties. That is, firstly, for a lab structure, the uncertainties associated to the OMA program used are studied and quantified. Secondly, for an in-service structure (a stress-ribbon footbridge), both the effect of the OMA program and the influence of environmental factor on the modal parameters estimation are studied. More concretely, a method to track natural frequencies of the same mode has been proposed. This method includes a multiple linear regression model that allows to remove the influence of these external agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El flameo o flutter es un fenómeno vibratorio debido a la interacción de fuerzas inerciales, elásticas y aerodinámicas. Consiste en un intercambio de energía, que se puede observar en el cambio de amortiguamientos, entre dos o más modos estructurales, denominados modos críticos, cuyas frecuencias tienden a acercarse (coalescencia de frecuencias). Los ensayos en vuelo de flameo suponen un gran riesgo debido a la posibilidad de una perdida brusca de estabilidad aeroelástica (flameo explosivo) con la posibilidad de destrucción de la aeronave. Además existen otros fenómenos asociados que pueden aparecer como el LCO (Limit Cycle Oscillation) y la interacción con los mandos de vuelo. Debido a esto, se deben llevar a cabo análisis exhaustivos, que incluyen GVT (vibraciones en tierra), antes de comenzar los ensayos en vuelo, y estos últimos deben ser ejecutados con robustos procedimientos. El objetivo de los ensayos es delimitar la frontera de estabilidad sin llegar a ella, manteniéndose siempre dentro de la envolvente estable de vuelo. Para lograrlo se necesitan métodos de predicción, siendo el “Flutter Margin”, el más utilizado. Para saber cuánta estabilidad aeroelástica tiene el avión y lo lejos que está de la frontera de estabilidad (a través de métodos de predicción) los parámetros modales, en particular la frecuencia y el amortiguamiento, son de vital importancia. El ensayo en vuelo consiste en la excitación de la estructura a diferentes condiciones de vuelo, la medición de la respuesta y su análisis para obtener los dos parámetros mencionados. Un gran esfuerzo se dedica al análisis en tiempo real de las señales como un medio de reducir el riesgo de este tipo de ensayos. Existen numerosos métodos de Análisis Modal, pero pocos capaces de analizar las señales procedentes de los ensayos de flameo, debido a sus especiales características. Un método novedoso, basado en la Descomposición por Valores Singulares (SVD) y la factorización QR, ha sido desarrollado y aplicado al análisis de señales procedentes de vuelos de flameo del F-18. El método es capaz de identificar frecuencia y amortiguamiento de los modos críticos. El algoritmo se basa en la capacidad del SVD para el análisis, modelización y predicción de series de datos con características periódicas y en su capacidad de identificar el rango de una matriz, así como en la aptitud del QR para seleccionar la mejor base vectorial entre un conjunto de vectores para representar el campo vectorial que forman. El análisis de señales de flameo simuladas y reales demuestra, bajo ciertas condiciones, la efectividad, robustez, resistencia al ruido y capacidad de automatización del método propuesto. ABSTRACT Flutter involves the interaction between inertial, elastic and aerodynamic forces. It consists on an exchange of energy, identified by change in damping, between two or more structural modes, named critical modes, whose frequencies tend to get closer to each other (frequency coalescence). Flight flutter testing involves high risk because of the possibility of an abrupt lost in aeroelastic stability (hard flutter) that may lead to aircraft destruction. Moreover associated phenomena may happen during the flight as LCO (Limit Cycle Oscillation) and coupling with flight controls. Because of that, intensive analyses, including GVT (Ground Vibration Test), have to be performed before beginning the flights test and during them consistent procedures have to be followed. The test objective is to identify the stability border, maintaining the aircraft always inside the stable domain. To achieve that flutter speed prediction methods have to be used, the most employed being the “Flutter Margin”. In order to know how much aeroelastic stability remains and how far the aircraft is from the stability border (using the prediction methods), modal parameters, in particular frequency and damping are paramount. So flight test consists in exciting the structure at various flight conditions, measuring the response and identifying in real-time these two parameters. A great deal of effort is being devoted to real-time flight data analysis as an effective way to reduce the risk. Numerous Modal Analysis algorithms are available, but very few are suitable to analyze signals coming from flutter testing due to their special features. A new method, based on Singular Value Decomposition (SVD) and QR factorization, has been developed and applied to the analysis of F-18 flutter flight-test data. The method is capable of identifying the frequency and damping of the critical aircraft modes. The algorithm relies on the capability of SVD for the analysis, modelling and prediction of data series with periodic features and also on its power to identify matrix rank as well as QR competence for selecting the best basis among a set of vectors in order to represent a given vector space of such a set. The analysis of simulated and real flutter flight test data demonstrates, under specific conditions, the effectiveness, robustness, noise-immunity and the capability for automation of the method proposed.