999 resultados para Oxygen -- Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to test the hypothesis that subjects having faster oxygen uptake (VO(2)) kinetics during off-transients to exercises of severe intensity would obtain the smallest decrement score during a repeated sprint test. Twelve male soccer players completed a graded test, two severe-intensity exercises, followed by 6 min of passive recovery, and a repeated sprint test, consisting of seven 30-m sprints alternating with 20 s of active recovery. The relative decrease in score during the repeated sprint test was positively correlated with time constants of the primary phase for the VO(2) off-kinetics (r = 0.85; p < 0.001) and negatively correlated with the VO(2) peak (r = -0.83; p < 0.001). These results strengthen the link found between VO(2) kinetics and the ability to maintain sprint performance during repeated sprints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Metabolic flux profiling based on the analysis of distribution of stable isotope tracer in metabolites is an important method widely used in cancer research to understand the regulation of cell metabolism and elaborate new therapeutic strategies. Recently, we developed software Isodyn, which extends the methodology of kinetic modeling to the analysis of isotopic isomer distribution for the evaluation of cellular metabolic flux profile under relevant conditions. This tool can be applied to reveal the metabolic effect of proapoptotic drug edelfosine in leukemia Jurkat cell line, uncovering the mechanisms of induction of apoptosis in cancer cells. Results: The study of 13C distribution of Jukat cells exposed to low edelfosine concentration, which induces apoptosis in ¿5% of cells, revealed metabolic changes previous to the development of apoptotic program. Specifically, it was found that low dose of edelfosine stimulates the TCA cycle. These metabolic perturbations were coupled with an increase of nucleic acid synthesis de novo, which indicates acceleration of biosynthetic and reparative processes. The further increase of the TCA cycle fluxes, when higher doses of drug applied, eventually enhance reactive oxygen species (ROS) production and trigger apoptotic program. Conclusion: The application of Isodyn to the analysis of mechanism of edelfosine-induced apoptosis revealed primary drug-induced metabolic changes, which are important for the subsequent initiation of apoptotic program. Initiation of such metabolic changes could be exploited in anticancer therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The renal enzyme renin cleaves from the hepatic alpha(2)-globulin angiotensinogen angiotensin-(1-10) decapeptide [Ang-(1-10)], which is further metabolized to smaller peptides that help maintain cardiovascular homeostasis. The Ang-(1-7) heptapeptide has been reported to have several physiological effects, including natriuresis, diuresis, vasodilation, and release of vasopressin and prostaglandins. METHODS: To investigate Ang-(1-7) in clinical settings, we developed a method to measure immunoreactive (ir-) Ang-(1-7) in 2 mL of human blood and to estimate plasma concentrations by correcting for the hematocrit. A sensitive and specific antiserum against Ang-(1-7) was raised in a rabbit. Human blood was collected in the presence of an inhibitor mixture including a renin inhibitor to prevent peptide generation in vitro. Ang-(1-7) was extracted into ethanol and purified on phenylsilylsilica. The peptide was quantified by radioimmunoassay. Increasing doses of Ang-(1-7) were infused into volunteers, and plasma concentrations of the peptide were measured. RESULTS: The detection limit for plasma ir-Ang-(1-7) was 1 pmol/L. CVs for high and low blood concentrations were 4% and 20%, respectively, and between-assay CVs were 8% and 13%, respectively. Reference values for human plasma concentrations of ir-Ang-(1-7) were 1.0-9.5 pmol/L (median, 4.7 pmol/L) and increased linearly during infusion of increasing doses of Ang-(1-7). CONCLUSIONS: Reliable measurement of plasma ir-Ang-(1-7) is achieved with efficient inhibition of enzymes that generate or metabolize Ang-(1-7) after blood sampling, extraction in ethanol, and purification on phenylsilylsilica, and by use of a specific antiserum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Maan hengityksen ja ohran kasvun reagointi hapensaannin muutoksiin maassa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vascular endothelium has been shown to play a pivotal role in the pathophysiology of sepsis through the expression of surface proteins and secretion of soluble mediators. Endocan (endothelial cell-specific molecule-1), a 50-kDa dermatan sulfate proteoglycan, is expressed by endothelial cells in lung and kidney and can be detected at low levels in the serum of healthy subjects. Increased concentrations were described in patients with sepsis, severe sepsis and septic shock compared to healthy individuals, with serum concentrations related to the severity of illness. In the present study, we investigated endocan, procalcitonin and C-reactive protein in postmortem serum from femoral blood in a series of sepsis-related fatalities and control individuals who underwent medicolegal investigations. Endocan was also measured in pericardial fluid. Two study groups were prospectively formed, a sepsis-related fatalities group and a control group. The sepsis-related fatalities group consisted of sixteen forensic autopsy cases with documented clinical diagnosis of sepsis in vivo. The control group consisted of sixteen forensic autopsy cases with various noninfectious causes of death. Postmortem serum endocan concentrations were significantly higher in the sepsis group, with values ranging from 0.519ng/ml to 6.756ng/ml. In the control group, endocan levels were undetectable in eleven out of sixteen cases. The results of the data analysis revealed similar endocan concentrations in the pericardial fluid of both studied groups. Endocan can be considered a suitable biological parameter for the detection of sepsis-related deaths in forensic pathology routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: To determine whether glycine can be measured at 7 T in human brain with (1)H magnetic resonance spectroscopy (MRS). MATERIALS AND METHODS: The glycine singlet is overlapped by the larger signal of myo-inositol. Density matrix simulations were performed to determine the TE at which the myo-inositol signal was reduced the most, following a single spin-echo excitation. (1)H MRS was performed on an actively shielded 7 T scanner, in five healthy volunteers. RESULTS: At the TE of 30 ms, the myo-inositol signal intensity was substantially reduced. Quantification using LCModel yielded a glycine-to-creatine ratio of 0.14 +/- 0.01, with a Cramer-Rao lower bound (CRLB) of 7 +/- 1%. Furthermore, quantification of metabolites other than glycine was possible as well, with a CRLB mostly below 10%. CONCLUSION: It is possible to detect glycine at 7 T in human brain, at the short TE of 30 ms with a single spin-echo excitation scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosisthat had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the influence of retinal structural changes on oxygen saturation in retinitis pigmentosa (RP) patients. METHODS: Oximetry measurements were performed on 21 eyes of 11 RP patients and compared to 24 eyes of 12 controls. Retinal oxygen saturation was measured in all major retinal arterioles (A-SO₂) and venules (V-SO₂) with an oximetry unit of the retinal vessel analyser (IMEDOS Systems UG, Jena, Germany). Oximetry data were compared with morphological changes measured by Cirrus optical coherence tomography (OCT) (Carl Zeiss Meditec, Dublin, CA, USA, macular thickness protocol). RESULTS: In RP patients, the retinal A-SO₂ and V-SO₂ levels were higher at 99.3% (p = 0.001, anova based on mixed-effects model) and 66.8% (p < 0.001), respectively, and the difference between the two (A-V SO₂) was lower at 32.5% (p < 0.001), when compared to the control group (92.4%; 54.0%; 38.4%, respectively). With the RP group, the A-V SO₂ correlated positively, not only with central macular thickness, but also with retinal thickness, in zones 2 and 3 (p = 0.006, p = 0.007, p = 0.014). CONCLUSION: These data indicate that oxygen metabolism was altered in RP patients. Based on our preliminary results, retinal vessel saturation correlated with structural alterations in RP. This method could be valuable in monitoring disease progression and evaluating a potential therapeutic response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the field application of the tilt sensing method for monitoring movement of the Black Hawk and Karl King Bridges. The study objectives were: to design a data acquisition system for tilt sensing equipment utilizing a telephone telemetry system; to monitor possible movement of the main span pier, Pier No. 2, on the Black Hawk Bridge in Lansing and the possible long-term movement of Pier No. 4 on the Karl King Bridge in Fort Dodge; and to assess the feasibility, reliability, and accuracy of the instrumentation system used in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.