963 resultados para Oral Surgery


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis was aimed at investigating the physical-chemical properties and the behaviour in physiological environment of two classes of bioceramics: calcium silicate-based dental cements and alumina-based femoral heads for hip joint prostheses. The material characterization was performed using spectroscopic techniques such as that allow to obtain information on the molecular structure of the species and phases present in the analyzed samples. Raman, infrared and fluorescence spectroscopy was principally used. Calcium silicate cements, such as MTA (Mineral Trioxide Aggregate), are hydraulic materials that can set in presence of water: this characteristic makes them suitable for oral surgery and in particular as root-end filling materials. With the aim to improve the properties of commercial MTA cements, several MTA-based experimental formulations have been tested with regard to bioactivity (i.e. apatite forming ability) upon ageing in simulated body fluids. The formation of a bone-like apatite layer may support the integration in bone tissue and represents an essential requirement for osteoconduction and osteoinduction. The spectroscopic studies demonstrated that the experimental materials under study had a good bioactivity and were able to remineralize demineralized dentin. . Bioceramics thanks to their excellent mechanical properties and chemical resistance, are widely used as alternative to polymer (UHMWPE) and metal alloys (Cr-Co) for hip-joint prostesis. In order to investigate the in vivo wear mechanisms of three different generations of commercial bioceramics femoral heads (Biolox®, Biolox® forte, and Biolox® delta), fluorescence and Raman spectroscopy were used to investigate the surface properties and residual stresses of retrieved implants. Spectroscopic results suggested different wear mechanisms in the three sets of retrievals. Since Biolox® delta is a relatively recent material, the Raman results on its retrievals has been reported for the first time allowing to validate the in vitro ageing protocols proposed in the literature to simulate the effects of the in vivo wear.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The purpose was to qualitatively and quantitatively compare the bone formation and graft resorption of two different bone substitutes used in both orthopedic and oral surgery, with autogenous bone as a positive control. MATERIALS AND METHODS: Three standardized bone defects were prepared in both mandibular angles of 12 adult minipigs. The defects were grafted with either autograft, anorganic bovine bone (ABB), or synthetic beta-tricalcium phosphate (beta-TCP). Sacrifice was performed after 1, 2, 4, and 8 weeks for histologic and histomorphometric analysis. RESULTS: At 2 weeks, more new bone formation was seen in defects filled with autograft than with ABB (P approximately 0.0005) and beta-TCP (P approximately 0.002). After 4 weeks, there was no significant difference between beta-TCP and the two other materials. Defects grafted with ABB still exhibited less bone formation as compared with autograft (P approximately 0.004). At 8 weeks, more bone formation was observed in defects grafted with autograft (P approximately 0.003) and beta-TCP (P approximately 0.00004) than with ABB. No difference could be demonstrated between beta-TCP and autograft. beta-TCP resorbed almost completely over 8 weeks, whereas ABB remained stable. CONCLUSION: Both bone substitutes seemed to decelerate bone regeneration in the early healing phase as compared with autograft. All defects ultimately regenerated with newly formed bone and a developing bone marrow. The grafting materials showed complete osseous integration. Both bone substitutes may have a place in reconstructive surgery where different clinical indications require differences in biodegradability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diagnostic and therapeutic interventions following dental injuries are not part of the routine practice in the dental office. Quite often, these patients are emergency cases who seek treatment after normal office hours. The objective of this and the future papers is to present the current treatment concepts in dental traumatology at the School of Dental Medicine, University of Berne. The fruitful cooperation in the field of dental traumatology between the Department of Oral Surgery and Stomatology, and the Department of Conservative Dentistry (including pediatric dentistry and endodontology), is based on the interdisciplinary approach that has been established four years ago. Following discussion and evaluation of such treated cases, and considering current clinical and experimental studies, the said concepts have been worked out. The present paper describes the therapeutic approach for root fractures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To compare the outcome of arthroscopic lysis and lavage of TMJ with internal derangement of Wilkes stages II, III, IV, and V. STUDY DESIGN: Arthroscopic lysis and lavage was performed in 45 TMJ of 39 patients with internal derangement. The cases were divided into 4 groups corresponding to Wilkes stages II, III, IV, and V. Two parameters were compared pre- and postoperatively: pain and mouth opening. Statistical significance was determined using the chi(2) test. RESULTS: Overall success rate was 86.7% (Wilkes stage II 90.9%, Wilkes stage III 92.3%, Wilkes stage IV 84.6%, Wilkes stage V 75%). There were no statistically significant differences between the success rates for Wilkes stages II, III, IV, and V. CONCLUSION: Arthroscopic lysis and lavage should be performed as a standard operation for internal derangement of the TMJ after failure of conservative treatment in all Wilkes stages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diagnostic and therapeutic interventions following dental injuries are not part of the routine practice in the dental office. Quite often, these patients are emergency cases who seek treatment after normal office hours. The objective of this and the future papers is to present the current treatment concepts in dental traumatology at the School of Dental Medicine, University of Berne. The fruitful cooperation in the field of dental traumatology between the Department of Oral Surgery and Stomatology, and the Department of Conservative Dentistry (including pediatric dentistry and endodontology) is based on the interdisciplinary approach that has been established five years ago. Following discussion and evaluation of such treated cases, and considering current clinical and experimental references, the said concepts have been worked out. The present paper describes the therapeutic concepts of crown fractures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The estimation of possible intra- and postoperative complications for surgical removal of third molars in the mandible poses a frequent dilemma in oral surgery. In the present study, the influence of the patient's age and gender, a reduced mouth opening, and the anatomical position of the tooth in the mandible on intra- and postoperative complications were evaluated. In a total of 120 surgically removed third molars, 9.2% intraoperative complications occurred, mainly bleeding. Factors influencing the risk for intraoperative complications were a male patient, a reduced mouth opening, and distally angulated teeth. Postoperative complications were encountered in 6.7%, mainly dry sockets. For this group, a female gender, a higher age, and distally angulated teeth were identified as risk parameters. As most of the patient- and anatomy-related factors are set parameters when evaluating possible risk factors for third molar surgery, only the timepoint of surgery can be influenced by the surgeon. Regarding the increase in intra- and postoperative complications for third molar removal in higher age groups, the prophylactic third molar surgery between the age of 18 and 25 seems justified.