996 resultados para OPTICAL EQUIPMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Avidin layer was bound on the substrate surface of Silicon wafer modified with aldehyde. The interaction between avidin and biotin was adopted for the immobilization of mouse monoclonal biotin-anti-M13 (antibody GP3)-labeled biotin. The surface was incubated in a solution containing phage M13KO7, which was trapped by the antibody GP3 with the interaction between phage M13KO7 and antibody GP3, resulting in a variation of layer thickness that was detected by imaging ellipsometry. The results showed a saturated layer of antibody GP3 with a thickness about 6.9 nm on the surface of the silicon wafer. The specific interaction between phage M13KO7 and antibody GP3 resulted in a variation of layer thickness. The layer of phage M13KO7 bound with antibody GP3 was 17.5 nm in the concentration of 1.1×1010 pfu/mL. Each variation of the layer thickness corresponded to a concentration of phage M13KO7 in the range of 0.1×1010–2.5×1010 pfu/mL, with the sensitivity of 109 pfu/mL. Compared with other methods, the optical protein-chip, requiring only short measurement time, label free, is a quantitative test, and can be visualized. This study could be significant on the interactions between the antibody and the virus, showing potential in the early diagnosis of virosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable validation based on the optical flow visualization for numerical simulations of complex flowfields is addressed in this paper. Several test cases, including two-dimensional, axisymmetric and three-dimensional flowfields, were presented to demonstrate the effectiveness of the validation and gain credibility of numerical solutions of complex flowfields. In the validation, images of these flowfields were constructed from numerical results based on the principle of the optical flow visualization, and compared directly with experimental interferograms. Because both experimental and numerical results are of identical physical representation, the agreement between them can be evaluated effectively by examining flow structures as well as checking discrepancies in density. The study shows that the reliable validation can be achieved by using the direct comparison between numerical and experiment results without any loss of accuracy in either of them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid crystal on silicon (LCOS) is one of the most exciting technologies, combining the optical modulation characteristics of liquid crystals with the power and compactness of a silicon backplane. The objective of our work is to improve cell assembly and inspection methods by introducing new equipment for automated assembly and by using an optical inspection microscope. A Suss-Micro'Tec Universal device bonder is used for precision assembly and device packaging and an Olympus BX51 high resolution microscope is employed for device inspection. ©2009 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report first experimental demonstration on the non-transparent characteristic of FWM using NRZ-DPSK, RZ-DPSK, CSRZ-DPSK, and CSRZ signals. One potential non-transparency application of 40Gbit/s CSRZ-to-RZ format conversion is experimentally demonstrated. © 2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein-Chip as micro-assays for the determination of protein interaction, the analysis, the identification and the purification of proteins has large potential applications. The Optical Protein-Chip is able to detect the multi-interaction of proteins and multi-bio-activities of molecules directly and simultaneously with no labeling. The chip is a small matrix on solid substrate containing multi-micro-area prepared by microfabrication with photolithography or soft lithography for surface patterning, and processed with surface modification which includes the physical, chemical, and bio-chemical modifications, etc. The ligand immobilization, such as protein immobilization, especially the oriented immobilization with low steric hindrance and high bio-specific binding activity between ligand and receptor is used to form a sensing surface. Each area of the pattern is corresponding to only one bioactivity. The interval between the areas is non-bioactive and optically extinctive. The affinity between proteins is used to realize non-labeling microassays for the determination of protein identification and protein interaction. The sampling of the chip is non-disturbing, performed with imaging ellipsometry and image processing on a database of proteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new control algorithm with reduced mode-hopping is demonstrated for uncooled WDM C-band channel generation from a DS-DBR laser with 100GHz spacing and low thermal drift up to 70°C. 10Gb/s external modulation with transmission over a 25km link is achieved. ©2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconfigurable shutter-based free-space optical switching technologies using fiber ribbon and multiple wavelengths per fiber for Storage Area Networks (SANs) application are presented and demonstrated. ©2009 SPIE-OSA-IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconfigurable shutter-based free-space optical switching technologies using fiber ribbon and multiple wavelengths per fiber for Storage Area Networks (SANs) application are presented and demonstrated. ©2009 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the architecture of a vector-matrix multiplier (MVM) is simulated. The optical design can be made compact by the use of GRIN lenses for the optical fan-in. The intended application area was in storage area networks (SANs) but the concept can be applied to a neural network. © 2011 Allerton Press, Inc.