975 resultados para Mosher esters
Resumo:
Purpose : To compare the radiopacity of 13 restorative materials, (a conventional glass-ionomer cement, three resin-modified glass-ionomer cements, six polyacid-modified resin-based composites, and three resin-based composites) to sound tooth structure. Materials and Methods: 315 specimens were made of the restorative materials (n= 21), of 2 min height and 4.1 mm diameter. Radiographs were taken of the specimens, together with the tooth structure sample and an aluminum step wedge. The radiopacity values of each specimen were taken using a transmission densitometer. Results: ANOVA and Tukey's test (95% level of confidence) revealed that, except for a resin-based composite, a polyacid-modified resin-based composite, a resin-modified glass-ionomer cement and the conventional glass-ionomer cement, all the evaluated restorative materials were more radiopaque than the tooth structure.
Resumo:
Purpose: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin. Methods: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1 - 10% phosphoric acid for 30 seconds; Group 2 - 37% phosphoric acid for 15 seconds; Group 3 - air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4 - air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37degreesC, thermocycled for 500 cycles in distilled water at 10degreesC and 50degreesC, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface. Results: Group 2 exhibited significantly (P< 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar.
Resumo:
Purpose: To evaluate the 1-year clinical performance of three self-etching adhesives (Adper Prompt L-Pop, Clearfil S-3 Bond, iBond) in posterior composite restorations using one etch&rinse adhesive (One-Step Plus) as control. Methods: Upon approval by the Institutional Review Board, 121 restorations were inserted in 38 subjects. The adhesives were applied as per manufacturers' instructions. Preparations were restored with a nanofilled resin composite (Filtek Supreme) and evaluated at baseline, 6 months, and 1 year. Statistical analyses included the Chi-square distribution with the McNemar non-parametric test (P< 0.05). Results: At 1 year, 111 restorations in 35 subjects were evaluated using the USPHS modified criteria. No significant changes were observed for the etch&rinse adhesive One-Step Plus. At 1 year the number of Alfa ratings decreased significantly for Clearfil S-3 Bond and for iBond in the categories color match, marginal staining, and marginal adaptation. For Adper Prompt L-Pop, marginal adaptation at 1 year was significantly worse than at baseline. Postoperative sensitivity to air improved significantly for Adper Prompt L-Pop, Clearfil S-3 Bond, and iBond. When the evaluation criteria were paired at 1 year, iBond resulted in a significantly lower number of Alfa ratings than any of the other adhesives for color match, marginal staining, and marginal adaptation. One-Step Plus resulted in a greater number of Alfa ratings for marginal adaptation than either Adper Prompt L-Pop or Clearfil S-3 Bond. Marginal adaptation was significantly better for Clearfil S-3 Bond than for Adper Prompt L-Pop. The post-operative sensitivity measured at 1 year for Adper Prompt L-Pop was statistically better than that for One-Step Plus.
Resumo:
Purpose: To investigate the microleakage of four hydrophilic adhesive systems: one multiple-bottles (Scotchbond Multi-Purpose Plus); two one-bottle (Single Bond, Stae); and one self-etching (Etch & Prime 3.0). Materials and Methods: 120 bovine incisor teeth were divided into four groups (n = 30) and Class V cavities were prepared at the cemento-enamel junction. The cavities were restored with the adhesive systems and with Z100 composite. The teeth were thermocycled 1,000 times between 5 +/- 2 degreesC and 55 +/- 2 degreesC with a dwell time of 1 min, and then placed in a 2% methylene blue dye (pH 7.0) for 4 hrs, washed and sectioned vertically through the center of the restorations. The qualitative evaluation was made by three examiners who distributed pre-established scores (0-4) for each tooth using a stereomicroscope at x30 magnification. Results: In enamel margins little microleakage was observed and the Kruskal-Wallis analysis did not show differences. In dentin margins the KruskaI-Wallis and multiple comparison analyses were applied: microleakage was significantly greater with Stae (median 3) and Scotchbond MP Plus (median 4). Single Bond (median 1) and Etch & Prime 3.0 (median 2) showed the best results in dentin margins, and the statistical analysis did not demonstrate differences in microleakage among these groups.
Resumo:
Fly soot samples collected in the sugar cane fields after the process of burning were extracted in a Soxhlet apparatus (methylene chloride:methanol 4:1). The extracts were fractionated on silica gel Sep-Pak cartridges into three fractions. A gas chromatographic-mass spectrometric study of the fly soot extracts allowed the identification of the PAH with mutagenic and carcinogenic properties. Large amounts of aliphatic hydrocarbons, fatty acid esters and some PAHs were identified by GCMS in full scan mode. GC-MS in the selective ion monitoring mode (SIM) was suitable for the determination of many PAHs, which are often present in the burnt biomass. 31 PAHs and 7 thiophens derivatives were identified. The presence of these compounds should be regarded as a caution to workers and the general population to avoid exposure to the fly soot.
Resumo:
Calcium binding and charge distribution on a fucosylated chondroitin sulfate and a standard chondroitin 6-sulfate have been studied using a metallochromic indicator and conductimetric titrations. The fucosylated chondroitin sulfate has a similar to 5-fold greater affinity for calcium ions than the standard chondroitin 6-sulfate. Possibly, this increased affinity for calcium ions is due to the branches on the fucosylated chondroitin sulfate, since the calcium affinity of an unbranched, sulfated fucan is similar to that of the standard chondroitin 6-sulfate. More charged groups per disaccharide unit (and a shorter distance between these groups) also distinguish the fucosylated chondroitin sulfate from standard chondroitin 6-sulfate. Comparison between native and chemically modified (desulfated or carboxyl-reduced) polysaccharides suggests that the sulfate esters are responsible for the increased charge density of the fucosylated chondroitin sulfate and that the presence of the fucose branches does not alter the length of the repetitive units which compose the central core of chondroitin from sea cucumber. These results are consistent with the chemical studies of these two polysaccharides.
Resumo:
The trunk wood and barks from an Aniba species contain four esters of benzoic acid with cinnamyl alcohol, five benzofuran neolignans, licarin-A, burchellin, cis-burchellin, burchellin-rearranged and cis-burchellin-rearranged, one tetrahydrofuran neolignan, aristolignin, three bicyclooctane guianin-type neolignans, (7S, 8S, 1'R, 5'R)-4-hydroxy-3,3'-dimethoxy-4',6'-dioxo-8.1', 7.5'-neolignan-Delta: 1,3,5,2',8' and the new (7S, 8S, 1'R, 4'R, 5'S)-4'-hydroxy-3,4,3'-trimethoxy-6'-oxo-8.1', 7.5'-neolignan-Delta: 1,3,5,2',8' and (7S, 8S, 1'R, 4'R, 5'S)-4,4'-dihydroxy-3,3'-dimethoxy-6'-oxo-8.1', 7.5'-neolignan-Delta: 1,3,5,2',8', one new bicyclooctane canellin-type neolignan (7S, 8S, 1'S, 4'R, 5'R, 6'S)-4',6'-dihydroxy-3,4-dimethoxy-3'-oxo-8.1', 7.5'-neolignan-Delta: 1,3,5,8', two styrylpyrones, 4-methoxy-6-(11,12-dimethoxy-trans-styryl)-2-pyrone and 6-(11,12-methylenedioxy-trans-styryl)-4-methoxy-2-pyrone, two styrylpyrone dimers: 4'-methoxy-8-(11,12-dimethoxyphenyl)-7-[6-(4-methoxy-2-pyronyl)-6-(E)-styryl-1'-oxabicyclo[4,2,0]octa-4'-en-2'-one and the new 11,12-dimethoxyphenyl-7,7'-di-[6-(4-methoxy-2-pyronyl)]-cyclobutane and six flavonoids, 3,5-dihydroxy-7,4'-dimethoxyflavone, 5-hydroxy-3,7,4'-trimethoxyflavone, 3,5,4'-trihydroxy-7-methoxyflavone, 2,3-dihydro-5-hydroxy-7,4'-dimethoxyflavone, 2,3-dihydro-3,5-dihydroxy-7-methoxyflavone, 2,3-dihydro-3,5-dihydroxy-7,4'-dimethoxyflavone and a new flavan, 6,7,3',4',5'-pentamethoxyflavan. (C) 1997 Elsevier B.V. Ltd.
Resumo:
Purpose: To evaluate the in vitro cytotoxic effects of three cleansing solutions used for chemical lavage of pulp exposures. Materials and Methods: the immortalized odontoblast cell line (MDPC-23) was plated (30,000 cells/cm(2)) and incubated for 72 hrs in 24-well dishes. After counting the cell number under inverted light microscopy, 20 mul of the experimental and control solutions were added to 980 mul of fresh culture medium. Then, hydrogen peroxide (3%, H2O2), sodium hypochlorite (6%, NaOCl) or calcium hydroxide-saline solution (5g of Ca(OH)(2) in 10 mi of sterile distilled water) were added to wells for experimental Groups 1, 2 and 3, respectively. The positive and negative control groups received Syntac Sprint bonding agent (SS) and phosphate buffered saline (PBS), respectively. Following incubation for 120 min the cell number was counted again, the cell morphology was evaluated by scanning electron microscopy (SEM) and the cell metabolism was determined by the methyltetrazolium (MTT) assay. The scores obtained from cell counting and MTT assay were analyzed with an ANOVA followed by Fisher's PLSD tests. Results: H2O2 NaOCl solutions, and SS bonding agent were more cytotoxic than Ca(OH)2 or PBS. In the groups with H2O2 Or SS, only a few cells remained attached to the bottom of wells. The difference between these two groups was not statistically significant. H2O2, NaOCl and SS depressed the mitochondrial enzyme response by 97.7%, 97.3%, and 95.0%, respectively. on the other hand, Ca(OH)2 depressed the metabolic activity of cells by only 5%. While H2O2, NaOCl and SS caused extreme changes on the cell morphology, neither Ca(OH)2 nor PBS promoted dramatic changes in the cell morphology.
Resumo:
From a hexane extract of stems and roots of Aristolochia pubescens, the new neolignans (2S,3S,1'R,2'R)- and (2S,3S, 1'S,2'R)-2,3-dihydro-5-(1',2'-dihydroxypropyl)-2-(4-hydroxy-3-methylbenzofuran) and (2S,3S,1'R,2'R)- and (2S,3S,1'S,2'R)-2,3-dihydro-5-(1',2'-dihydroxypropyl)-2-(3,4-dimethoxyphenyl)-7-methoxy-3-methyl-benzofuran were isolated, together with the known neolignan licarin A, and its bisnor-neolignan aldehyde and acid derivatives. In addition, sitosterol, 8R,9R-oxide-beta-caryophyllene, kobusone, ent-kauran-16 alpha, 17-diol, vanillin, vanillic acid, (+)-sesamin, (+)eudesmin, and (-)-cubebin were isolated. The structures of the new compounds have been elucidated by spectroscopic methods and by chemical transformation using Mosher's acid chloride. (C) 1999 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Purpose : the aim of this study was to evaluate the effect of nozzle angle and tip diameter on the cutting efficiency of an air abrasion system. Materials and Methods: Thirty-six extracted human third molars were air-abraded with the PrepStar microabrasion machine using a handpiece with either 80degrees or 45degrees nozzle angles with 0.38 or 0.48 nun tip orifice diameters. The following parameters were held constant: abrasive particle size (27 mum), air pressure (80 psi), distance (2 mm.) and duration (15 seconds). The cutting efficiency was compared using enamel, dentin and cementum substrates. Width and depth of the cutting patterns were analyzed and measured using scanning electron micrographs. Results: Statistical analysis using three-way ANOVA and Duncan's Multiple Range test revealed that the width of the cuts was significantly greater when the cavities were prepared using the 45degrees nozzle angle. Significantly deeper cavities were produced with the 80degrees nozzle angle. The tip orifice of the nozzle influenced the cutting efficiency in softer substrates, dentin and cementum. Precise removal of hard tissue is best accomplished using the 80degrees angle nozzle tips for all types of tooth surfaces, enamel, dentin and cementum.
Resumo:
Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
The three-layer capacitor model proposed by Demchak and Fort [J. Colloid Interface Sci. 46 (1974) 191] is employed to relate measured surface potentials of Langmuir monolayers from a series of polyphenyl carboxylic acids to molecular dipole moments calculated using semiempirical quantum methods. The effective dielectric constant at the air/monolayer interface is 3.0 +/- 0.6, very close to that estimated for aliphatic compounds. Good agreement between theory and experiment is obtained by adopting a dielectric constant of 6.4 for the monolayer/water interface and a contribution from the water reorientation of -0.064 +/- 0.006 D, which shows that the parameters in the DF model are essentially the same as for aliphatic amphiphiles, such as esters, acids, alcohols and ethers. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Purpose: To evaluate the effect of various bleaching agents on the cemento-enamel junction (CEJ) of human teeth by scanning electron microscopy (SEM) analysis. Methods: 30 intact teeth were selected and longitudinally sectioned, yielding 60 specimens. Thirty specimens served as controls; the other 30 were divided into six groups with five specimens each (n= 5) and bleached according to six protocols (Group 1: External bleaching with 10% carbamide peroxide; Group 2: External bleaching with 35% hydrogen peroxide; Group 3: External bleaching with 35% hydrogen peroxide; Group 4: Internal/external bleaching with 35% hydrogen peroxide; Group 5: Internal/external bleaching with 35% hydrogen peroxide; and Group 6: Intracoronal bleaching with a paste of sodium perborate mixed with 9% hydrogen peroxide). After treatment the specimens were prepared and examined in a scanning electron microscope. Results: the bleaching agents used in this study caused morphological changes in the CEJ and increased dentin exposure.
Resumo:
The efficiency of two methods for determining 3-hydroxybutyrate and 3-hydroxyvalerate content in the biopolymer (poly(3-hydroxybutyrate-co-3-hydroxyvalerate) has been evaluated. Both methods are based on (a) the hydrolysis of polymers, (b) the esterification with methyl (method A) and isoamilic alcohol (method B) and (c) analysis of the esters by gas chromatography using flame ionization detection (GC-FID). After optimization of the analytical conditions, the main validation parameters (linearity, quantification limit, detection limit, recovery, sensitivity and precision) were determined showing that both analytical procedures can be applied to control the process of poly(3-hydroxybutyrate) production. However, method B gives better analytical results than method A and has the advantage of not using chlorinated solvents.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)