941 resultados para Method of extraction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report an adaptation of a technique for the blood sample collection (GFM) as well as for the extraction and amplification of Plasmodium DNA for the diagnosis of malaria infection by the PCR/ELISA. The method of blood sample collection requires less expertise and saves both time and money, thus reducing the cost by more than half. The material is also suitable for genetic analysis in either fresh or stored specimens prepared by this method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Química Sustentável

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simulated moving bed (SMB) chromatography is attracting more and more attention since it is a powerful technique for complex separation tasks. Nowadays, more than 60% of preparative SMB units are installed in the pharmaceutical and in the food in- dustry [SDI, Preparative and Process Liquid Chromatography: The Future of Process Separations, International Strategic Directions, Los Angeles, USA, 2002. http://www. strategicdirections.com]. Chromatography is the method of choice in these ¯elds, be- cause often pharmaceuticals and ¯ne-chemicals have physico-chemical properties which di®er little from those of the by-products, and they may be thermally instable. In these cases, standard separation techniques as distillation and extraction are not applicable. The noteworthiness of preparative chromatography, particulary SMB process, as a sep- aration and puri¯cation process in the above mentioned industries has been increasing, due to its °exibility, energy e±ciency and higher product purity performance. Consequently, a new SMB paradigm is requested by the large number of potential small- scale applications of the SMB technology, which exploits the °exibility and versatility of the technology. In this new SMB paradigm, a number of possibilities for improving SMB performance through variation of parameters during a switching interval, are pushing the trend toward the use of units with smaller number of columns because less stationary phase is used and the setup is more economical. This is especially important for the phar- maceutical industry, where SMBs are seen as multipurpose units that can be applied to di®erent separations in all stages of the drug-development cycle. In order to reduce the experimental e®ort and accordingly the coast associated with the development of separation processes, simulation models are intensively used. One impor- tant aspect in this context refers to the determination of the adsorption isotherms in SMB chromatography, where separations are usually carried out under strongly nonlinear conditions in order to achieve higher productivities. The accurate determination of the competitive adsorption equilibrium of the enantiomeric species is thus of fundamental importance to allow computer-assisted optimization or process scale-up. Two major SMB operating problems are apparent at production scale: the assessment of product quality and the maintenance of long-term stable and controlled operation. Constraints regarding product purity, dictated by pharmaceutical and food regulatory organizations, have drastically increased the demand for product quality control. The strict imposed regulations are increasing the need for developing optically pure drugs.(...)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The distribution of the surface proteins of toxoplasma gondii radiodinated were studied using the phase separation technique and ability of binding in the phenyl-Sepharose column. Eight polypeptides with Mr 22 to 180 distributed exclusively in the detergent rich-phase, while six polypeptides with mol. wt. 15,000 to 76,000 distributed exclusively in the detergent poor-phase. Twopolypeptides with 15,000 and 70,000 distributed on both phase. All the polypeptides present in the detergent rich-phase binding in the phenyl-Sepharose column, and can be isolated in two peak according with their relative hydrophobicities.two polypeptides hydrophobic with Mr 60 and 66 recognized by human serum were isolated by the association of the two technique. Our result showed that the surface proteins of t. gondii present different degrees of hydrophobicity and that the use of hydrophobic interaction chromatography after Triton X-114 extraction may be an important isolation method of membrane proteins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La sospita de bacterièmia relacionada a catèter (BRC) necessita la retirada d’aquest, confirmant-se a posteriori només en un 15-25%. La diferencia en el temps de positivització d´ hemocultius (DTP) ha demostrat ser un mètode fiable per el diagnòstic de BRC evitant la retirada del catèter. Amb la intenció de comprovar la utilitat clínica de la DTP, l’hem comparada amb un mètode diagnòstic estàndard. Hem inclòs 133 pacients ingressats a una unitat de cures intensives portadors de catèters venosos centrals. 56 pacients s’han aleatoritzats. No hem trobat diferències significatives en quant a morbi-mortalitat en els 2 grups havent evitat 70% de retirada innecessària de catèters en el grup de DTP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Disease management, a system of coordinated health care interventions for populations with chronic diseases in which patient self-care is a key aspect, has been shown to be effective for several conditions. Little is known on the supply of disease management programs in Switzerland. Objectives: To systematically search, record and evaluate data on existing disease management programs in Switzerland. Methods: Programs met our operational definition of disease management if their interventions targeted a chronic disease, included a multidisciplinary team and lasted at least 6 months. To find existing programs, we searched Swiss official websites, Swiss web-pages using Google, medical electronic database (Medline), and checked references from selected documents. We also contacted personally known individuals, those identified as possibly working in the field, individuals working in major Swiss health insurance companies and people recommended by previously contacted persons (snow ball strategy). We developed an extraction grid and collected information pertaining to the following 8 domains: patient population, intervention recipient, intervention content, delivery personnel, method of communication, intensity and complexity, environment and clinical outcomes (measures?). Results: We identified 8 programs fulfilling our operational definition of disease management. Programs targeted patients with diabetes, hypertension, heart failure, obesity, alcohol dependence, psychiatric disorders or breast cancer, and were mainly directed towards patients. The interventions were multifaceted and included education in almost all cases. Half of the programs included regularly scheduled follow-up, by phone in 3 instances. Healthcare professionals involved were physicians, nurses, case managers, social workers, psychologists and dietitians. None fulfilled the 6 criteria established by the Disease Management Association of America. Conclusions: Our study shows that disease management programs, in a country with universal health insurance coverage and little incentive to develop new healthcare strategies, are scarce, although we may have missed existing programs. Nonetheless, those already implemented are very interesting and rather comprehensive. Appropriate evaluation of these programs should be performed in order to build upon them and try to design a generic disease management framework suited to the Swiss healthcare system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe chronic disease management programs active in Switzerland in 2007, using an exploratory survey. METHODS: We searched the internet (Swiss official websites and Swiss web-pages, using Google), a medical electronic database (Medline), reference lists of pertinent articles, and contacted key informants. Programs met our operational definition of chronic disease management if their interventions targeted a chronic disease, included a multidisciplinary team (>/=2 healthcare professionals), lasted at least six months, and had already been implemented and were active in December 2007. We developed an extraction grid and collected data pertaining to eight domains (patient population, intervention recipient, intervention content, delivery personnel, method of communication, intensity and complexity, environment, clinical outcomes). RESULTS: We identified seven programs fulfilling our operational definition of chronic disease management. Programs targeted patients with diabetes, hypertension, heart failure, obesity, psychosis and breast cancer. Interventions were multifaceted; all included education and half considered planned follow-ups. The recipients of the interventions were patients, and healthcare professionals involved were physicians, nurses, social workers, psychologists and case managers of various backgrounds. CONCLUSIONS: In Switzerland, a country with universal healthcare insurance coverage and little incentive to develop new healthcare strategies, chronic disease management programs are scarce. For future developments, appropriate evaluations of existing programs, involvement of all healthcare stakeholders, strong leadership and political will are, at least, desirable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sandfly Phlebotomus perniciosus is the most widespread vector of Leishmania infantum in Spain. Laboratory colonisation represents the most feasible source of information on the biology of these insects, but in conducting any study, the density of individuals in the colony may drop to such an extent that it is sometimes difficult to recover the initial population levels. A new technique was tested for the recovery of sandfly eggs in three different colonies; the recovery rate was studied by comparing the standard method of mass rearing with this new method of colony management. The results demonstrate a mean increase of 18.4% in adult production, a growth in colony productivity that justifies the inclusion of this process in the routine maintenance of any colony of sandflies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: In bladder cancer, conventional white light endoscopic examination of the bladder does not provide adequate information about the presence of "flat" urothelial lesions such as carcinoma in situ. In the present investigation, we examine a new technique for the photodetection of such lesions by the imaging of protoporphyrin IX (PpIX) fluorescence following topical application of 5-aminolevulinic acid (ALA). STUDY DESIGN/MATERIALS AND METHODS: Several hours after bladder instillation of an aqueous solution of ALA in 34 patients, a Krypton ion laser or a filtered Xenon arc-lamp was used to excite PpIX fluorescence. Tissue samples for histological analysis were taken while observing the bladder wall either by means of a video camera, or by direct endoscopic observation. RESULTS: A good correlation was found between the PpIX fluorescence and the histopathological diagnosis. On a total of 215 biopsies, 143 in fluorescent and 72 in nonfluorescent areas, all visible tumors on white light cytoscopy appeared in a bright red fluorescence with the photodetection technique. In addition, this method permitted to discover 47 unsuspected carcinomatous lesions on white light observation, among which 40% were carcinoma in situ. CONCLUSION: PpIX fluorescence induced by instillation into the bladder of 5-ALA is an efficient method of mapping the mucosa in bladder carcinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peripheral venous cannulation is the preferred method of inserting central venous silastic catheters in premature infants. The standard techniques are placement of the catheter using a breakaway introducer needle or introduction of the catheter through a cannula. In extremely low birth weight infants (<1000 g) successful cannulation is impeded by the small size of the vessels. After repeated attempts, both procedures can be time-consuming and stressful to the infant. We present a modified insertion technique of the standard 2-French silastic catheter with an increased success rate, thus reducing insertion time, stress to the infant, and costs. The method uses the tip of a 20-gauge cannula as dilator/introducer for the 2-French catheter. This tip is inserted into the vessel with a standard 24-gauge cannula. After successful insertion of the dilator/introducer cannula, the standard 2-French catheter can then be advanced easily.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel numerical approach for the comprehensive, flexible, and accurate simulation of poro-elastic wave propagation in 2D polar coordinates. An important application of this method and its extensions will be the modeling of complex seismic wave phenomena in fluid-filled boreholes, which represents a major, and as of yet largely unresolved, computational problem in exploration geophysics. In view of this, we consider a numerical mesh, which can be arbitrarily heterogeneous, consisting of two or more concentric rings representing the fluid in the center and the surrounding porous medium. The spatial discretization is based on a Chebyshev expansion in the radial direction and a Fourier expansion in the azimuthal direction and a Runge-Kutta integration scheme for the time evolution. A domain decomposition method is used to match the fluid-solid boundary conditions based on the method of characteristics. This multi-domain approach allows for significant reductions of the number of grid points in the azimuthal direction for the inner grid domain and thus for corresponding increases of the time step and enhancements of computational efficiency. The viability and accuracy of the proposed method has been rigorously tested and verified through comparisons with analytical solutions as well as with the results obtained with a corresponding, previously published, and independently bench-marked solution for 2D Cartesian coordinates. Finally, the proposed numerical solution also satisfies the reciprocity theorem, which indicates that the inherent singularity associated with the origin of the polar coordinate system is adequately handled.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a novel numerical approach for the comprehensive, flexible, and accurate simulation of poro-elastic wave propagation in cylindrical coordinates. An important application of this method is the modeling of complex seismic wave phenomena in fluid-filled boreholes, which represents a major, and as of yet largely unresolved, computational problem in exploration geophysics. In view of this, we consider a numerical mesh consisting of three concentric domains representing the borehole fluid in the center, the borehole casing and the surrounding porous formation. The spatial discretization is based on a Chebyshev expansion in the radial direction, Fourier expansions in the other directions, and a Runge-Kutta integration scheme for the time evolution. A domain decomposition method based on the method of characteristics is used to match the boundary conditions at the fluid/porous-solid and porous-solid/porous-solid interfaces. The viability and accuracy of the proposed method has been tested and verified in 2D polar coordinates through comparisons with analytical solutions as well as with the results obtained with a corresponding, previously published, and independently benchmarked solution for 2D Cartesian coordinates. The proposed numerical solution also satisfies the reciprocity theorem, which indicates that the inherent singularity associated with the origin of the polar coordinate system is handled adequately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In arson cases, the collection and detection of traces of ignitable liquids on a suspect's hands can provide information to a forensic investigation. Police forces currently lack a simple, robust, efficient and reliable solution to perform this type of swabbing. In this article, we describe a study undertaken to develop a procedure for the collection of ignitable liquid residues on the hands of arson suspects. Sixteen different collection supports were considered and their applicability for the collection of gasoline traces present on hands and their subsequent analysis in a laboratory was evaluated. Background contamination, consisting of volatiles emanating from the collection supports, and collection efficiencies of the different sampling materials were assessed by passive headspace extraction with an activated charcoal strip (DFLEX device) followed by gas chromatography-mass spectrometry (GC-MS) analysis. After statistical treatment of the results, non-powdered latex gloves were retained as the most suitable method of sampling. On the basis of the obtained results, a prototype sampling kit was designed and tested. This kit is made of a three compartment multilayer bag enclosed in a sealed metal can and containing three pairs of non-powdered latex gloves: one to be worn by the sampler, one consisting of a blank sample and the last one to be worn by the person suspected to have been in contact with ignitable liquids. The design of the kit was developed to be efficient in preventing external and cross-contaminations.