986 resultados para METAL-INSULATOR-SEMICONDUCTOR DEVICES


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Eletrónica e Computadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work aims to contribute for the elucidation of the role of oxidative stress in the toxicity associated with the exposure of Pichia kudriavzevii to multi-metals (Cd, Pb and Zn). Cells of the non-conventional yeast P. kudriavzevii exposed for 6 h to the action of multi-metals accumulated intracellular reactive oxygen species (ROS), evaluated through the oxidation of the probe 2,7-dichlorodihydrofluorescein diacetate. A progressive loss of membrane integrity (monitored using propidium iodide) was observed in multi-metal-treated cells. The triggering of intracellular ROS accumulation preceded the loss of membrane integrity. These results suggest that the disruption of membrane integrity can be attributed to the oxidative stress. The exposure of yeast cells to single metal showed that, under the concentrations tested, Pb was the metal responsible for the induction of the oxidative stress. Yeast cells coexposed to an antioxidant (ascorbic acid) and multi-metals did not accumulate intracellular ROS, but loss proliferation capacity. Together, the data obtained indicated that intracellular ROS accumulation contributed to metal toxicity, namely for the disruption of membrane integrity of the yeast P. kudriavzevii. It was proposed that Pb toxicity (the metal responsible for the toxic symptoms under the conditions tested) result from the combination of an ionic mechanism and the intracellular ROS accumulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PhD in Sciences Specialty in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se trata de elucidar los procesos de oxidación-reducción electroquímica de compuestos orgánico aromáticos. Interesan los productos de reacción y el manejo de las variables externas para lograr la optimización de los que sean de interés. Estos estudios se realizan en medios homogéneos y además en medios bifásicos. Así se estudian procesos de electrodos con sustancias orgánicas en sistemas bifásicos líquido-líquido. Interesan conocer los mecanismos de fotoelectroquímica de moléculas biomiméticas tales como carotenos y porfirinas, principalmente en lo referente a la producción de fotocorriente. También se estudian procesos relacionados a la preparación y obtención de electrodos modificados por sustancias orgánicas poliméricas y electrodos sensores como los de metal-óxido y polímero orgánico-metal polidisperso. Objetivos generales y específicos: Los estudios electroquímicos con sustancias orgánicas comprenden una amplia gama de posibilidades. En este proyecto se estudian procesos de electrodo de diversas sustancias orgánicas donde se trata de dilucidar los mecanismos de los procesos redox en general. En lo particular se estudia el comportamiento electroquímico y fotoelectroquímico de sustancias biomiméticas como son los compuestos carotenoides y porfirinas. Interesa fundamentalmente la producción de fotocorriente obtenidas a través de la fotoexcitación. Se propone analizar la sensibilización de semiconductores (SnO2) por medio de moléculas biomiméticas. Estas últimas actúan como aceptor primario de energía radiante y transfieren un hueco o un electrón desde el estado excitado a las bandas de energía del semiconductor base. También se estudian procesos relacionados con la preparación y obtención de electrodos modificados por sustancias orgánicas poliméricas. En este laboratorio ya se han obtenido varios tipos de polímeros y en este proyecto se propone someterlos a condiciones extremas de potencial y a medios agresivos a fin de determinar este tipo de propiedades. Una de las aplicaciones inmediatas de estos electrodos es utilizarlos como sensores electroquímicos para diversas sustancias orgánicas. Por otro lado se estudian procesos electroquímicos en interfaces líquido/ líquido, pseudofaces (micelas) además de medios homogéneos. Como reacción modelo se utiliza nitración de naftaleno.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adoption of a sustainable approach to meeting the energy needs of society has recently taken on a more central and urgent place in the minds of many people. There are many reasons for this including ecological, environmental and economic concerns. One particular area where a sustainable approach has become very relevant is in the production of electricity. The contribution of renewable sources to the energy mix supplying the electricity grid is nothing new, but the focus has begun to move away from the more conventional renewable sources such as wind and hydro. The necessity of exploring new and innovative sources of renewable energy is now seen as imperative as the older forms (i.e. hydro) reach the saturation point of their possible exploitation. One such innovative source of energy currently beginning to be utilised in this regard is tidal energy. The purpose of this thesis is to isolate one specific drawback to tidal energy, which could be considered a roadblock to this energy source being a major contributor to the Irish national grid. This drawback presents itself in the inconsistent nature in which a tidal device generates energy over the course of a 24 hour period. This inconsistency of supply can result in the cycling of conventional power plants in order to even out the supply, subsequently leading to additional costs. The thesis includes a review of literature relevant to the area of tidal and other marine energy sources with an emphasis on the state of the art devices currently in development or production. The research carried out included tidal data analysis and manipulation into a model of the power generating potential at specific sites. A solution is then proposed to the drawback of inconsistency of supply, which involves the positioning of various tidal generation installations at specifically selected locations around the Irish coast. The temporal shift achieved in the power supply profiles of the individual sites by locating the installations in the correct locations, successfully produced an overall power supply profile with the smoother curve and a consistent base load energy supply. Some limitations to the method employed were also outlined, and suggestions for further improvements to the method were made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O benefício clínico de intervenção coronária percutânea (ICP) para lesões coronárias longas é incerto; além disso, foram levantadas dúvidas questões sobre a sua segurança. OBJETIVO: Avaliar os preditores de eventos cardíacos adversos maiores (ECAM) associados à ICP utilizando Full Metal Jacket (FMJ), definido como a sobreposição de stents farmacológicos (SF) medindo >60 mm de comprimento, para lesões muito longas. MÉTODOS: Foram incluídos 136 pacientes consecutivos com lesões coronárias longas, requerendo FMJ em nosso cadastro de centro único. O desfecho primário incluiu a ocorrência combinada de todas as causas de morte, infarto do miocárdio (IM) e revascularização do vaso alvo (RVA). Variáveis demográficas, clínicas, angiográficas e de procedimento foram avaliadas por meio de análise de regressão de Cox para determinar os preditores independentes de desfecho. RESULTADOS: O comprimento médio do stent por lesão foi de 73,2 ± 12,3 mm e o diâmetro médio do vaso de referência foi de 2,9 ± 0,6 mm. O sucesso angiográfico foi de 96,3%. A ausência de ECAM foi de 94,9% em 30 dias e 85,3% em um ano. No acompanhamento de um ano, a taxa de mortalidade por todas as causas foi de 3,7% (1,5% por mortes cardíacas), a taxa de IM foi de 3,7%, e a incidência de trombose de stent (TS) definitiva ou provável foi de 2,9%. O gênero feminino [risco relativo (RR), 4,40; intervalo de confiança de 95% (IC), 1,81-10,66, p = 0,001) e ICP de artéria coronária não direita (RR, 3,49; p = 0,006; IC 95%, 1,42-8,59) foram preditores independentes de ECAM em um ano. A ausência de eventos adversos em um ano foi maior em pacientes com angina estável submetidos à ICP (RR, 0,33; IC 95% 0,13-0,80, p = 0,014). CONCLUSÕES: A ICP utilizando FMJ com SF para lesões muito longas foi eficaz, mas associada a uma alta taxa de TS em acompanhamento de um ano. No entanto, a taxa de mortalidade cardíaca, IM não relacionado a procedimento, e ECAM foi relativamente baixa. ICP de vaso coronário alvo, apresentação clínica, e gênero feminino são novos fatores clínicos contemporâneos que parecem apresentar efeitos adversos sobre o resultado da ICP utilizando FMJ para lesões longas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain uncertain.Objective:To investigate long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).Methods:We performed search of MEDLINE, EMBASE, the Cochrane library, and ISI Web of Science (until February 2013) for randomized trials comparing more than 12-month efficacy or safety of DES with BMS in patients with STEMI. Pooled estimate was presented with risk ratio (RR) and its 95% confidence interval (CI) using random-effects model.Results:Ten trials with 7,592 participants with STEMI were included. The overall results showed that there was no significant difference in the incidence of all-cause death and definite/probable stent thrombosis between DES and BMS at long-term follow-up. Patients receiving DES implantation appeared to have a lower 1-year incidence of recurrent myocardial infarction than those receiving BMS (RR = 0.75, 95% CI 0.56 to 1.00, p= 0.05). Moreover, the risk of target vessel revascularization (TVR) after receiving DES was consistently lowered during long-term observation (all p< 0.01). In subgroup analysis, the use of everolimus-eluting stents (EES) was associated with reduced risk of stent thrombosis in STEMI patients (RR = 0.37, p=0.02).Conclusions:DES did not increase the risk of stent thrombosis in patients with STEMI compared with BMS. Moreover, the use of DES did lower long-term risk of repeat revascularization and might decrease the occurrence of reinfarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO, Epitaxy, Metal organic vapor phase epitaxy, MOCVD, CVD, Semiconductor, Optoelectronics, X-ray diffraction, Cathodoluminescence, Microelectronics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quenching process, TRIP, J2-plasticity theory, phase transition, distortion

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012