Resumo:
Values of repeatability (r) and reproducibility (R) are parameters of an analytical method. They are related to the maximum difference between two results of analysis (permissible range) and can be obtained by interlaboratorial comparisons. They represent great importance for the quality control of the results and decisions about the fitness-for-purpose of the method. Water determination in fuel oil samples were performed by 16 laboratories, using the Karl Fischer reaction, during the period from June 1997 to December 1999. Values of r and R were presented. Discussion is made in terms of the main factors that would be contribution to analytical method variabilities and uncertainties of final results.
Resumo:
The aim of this paper was to compare methods of moisture determination to choose the best one for the determination of this parameter in royal jelly samples. Royal jelly is sensitive to high temperatures becoming dark and loosing volatiles in high temperatures. The methods were: vacuum oven at 60 ºC, 70 ºC, conventional oven at 105 ºC, Karl Fisher, dissecator with sulfuric acid and dryness with infrared light at 105 ºC. Based on the results, the best method was the dissecator with sulfuric acid for moisture determination in royal jelly.
Resumo:
An automatic flow injection procedure for spectrophotometric aluminium determination in purified water and solutions containing high salts concentrations used for hemodyalisis treatment was developed. The method was base on reaction of Al3+ with cianine eriochrome R (ECR) after preconcentration using the AG50W-X8 cationic-exchange resin. Elution was carried out using a 1 % (m/v) calcium chloride solution. The manifold comprised an automatic proporcional injector controlled by a computer equipped with an eletronic interface and software written in QuicBASIC 4.5 with facilities to control the injector and perform data acquisition. Samples with concentration ranging from 4.96 to 19.90 µg L-1 Al were analyzed and recoveries between 88 and 113% were obtained by using the standard addition method. Other profitable analytical characteristics such as a relative standard deviation 1.3 % (n = 10) for a typical sample 14.5 µg L-1 Al, a linear response ranging up to 60.0 µg L-1Al, and a sampling throughput of 10 determinations per hour were achieved. A detection limit of 4.2 µg L-1 Al was estimated as suggested by IUPAC.
Resumo:
In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.
Resumo:
The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.
Resumo:
Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 ± 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 ± 0.3 mg/g of creatinine).
Resumo:
In this work a micro-heater device to be used as an integral part of the flow analysis manifold is described. The usefulness of the device was demonstrated using it in the development of a multicommutated flow analysis procedure for the spectrophotometric determination of manganese in plant digest. The method was based on the manganese oxidation by periodate in phosphoric acid medium to form the permanganate anion. The reaction development is dependent on the temperature and it was observed that at 25 °C a time interval of ca. 15 min was necessary for the reaction to attain equilibrium. Setting the temperature to 70 ºC, this time interval could be decreased to ca. 30 s. This condition was easily attained employing the proposed micro-heater device coupled to the manifold. The procedure was applied to manganese determination in soybean digests and results compared with those obtained by inductively coupled argon plasma optical emission spectrometry (ICP-OES). No significant difference at 90% confidence level was observed. A linear response for sample concentrations ranging from 5.0 to 30.00 mg L-1 Mn2+; a relative standard deviation of 1.3% (n = 6) for a typical sample containing 6.3 mg L-1 Mn2+; a sampling rate of 22 determinations per hour; a low reagent consumption, of 12.0 mg NaIO4 per determination; and a detection limit of 1.2 mg L-1 were achieved.
Resumo:
This work presents zinc determination in certain medicines that contain zinc oxide and zinc undecylenate. The technique consists of a spectrophotometric micro-scale titration, where EDTA is used as titrant, and xylenol orange as an indicator, in a medium adjusted to pH = 6 with acetic acid and sodium acetate. After each added portion of EDTA, the absorbance value is measured at a selected wavelength, in order to detect the end-point of the spectrophotometric titration. The results already obtained are satisfactory and promote student's interest. An additional contribution intends to propose the use of micro-scale techniques.
Resumo:
The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.
Resumo:
The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.
Resumo:
Coffee is one of the beverages most widely consumed in the world and the "cafezinho" is normally prepared from a blend of roasted powder of two species, Coffea arabica and Coffea canephora. Each one exhibits differences in their taste and in the chemical composition, especially in the caffeine percentage. There are several procedures proposed in the literature for caffeine determination in different samples like soft drinks, coffee, medicines, etc but most of them need a sample workup which involves at least one step of purification. This work describes the quantitative analysis of caffeine using ¹H NMR and the identification of the major components in commercial coffee samples using 1D and 2D NMR techniques without any sample pre-treatment.
Resumo:
A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.
Resumo:
In terms of soil fertility, zinc is a micronutrient that is very important in the culture of soy, maize, rice and coffee, because it is a structural and functional component of a great number of enzymes. Therefore, diverse methods have been used to determine zinc in soil. In this work we use colorimetry as a methods of zinc determination in soil using two methodologies of sample digesting, H2SO4/H2O2 and HNO3/H2O2. In order to compare the results, atomic absorption spectrometry (AAS) was used. Results show that colorimetric methods can be used due to good sensitivity and reproducibility, since the zinc calibration curve showed good linearity. Comparing colorimetric methods with AAS we observed that the results were equivalent, as proven by the statistical values of the F and t of Student tests. Furthermore, both methods of soil digesting can be used, leading to a flexible methodology of low-cost for routine zinc analyses in soil.
Resumo:
This article describes a literature review of the influence of advertising and the media on Eating Disorders (ED). Research published in scientific journals in various fields of social sciences such as sychology, psychiatry and communication science has enabled us to conclude that the content displayed in the media, including advertising, are enhancers of disorders and contribute significantly to body issatisfaction in relation to the perceived idea of beauty, it also facilitates the development of weight loss strategies in women and gain of muscle mass in men.
Resumo:
This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.