915 resultados para Loading capacities
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To evaluate the influence of different insertion torques on healing of implants loaded immediately or left unloaded.Material and methods: In six Labrador dogs, all mandibular premolars and molars were extracted. After 4 months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. The distal sites were prepared conventionally while the mesial sites were underprepared by 0.3 mm. As a consequence, different final insertion torques of about 30 Ncm at the distal and >70 Ncm at the mesial sites were recorded. Healing abutments were applied to the left and transmucosal abutments to the right side. Flaps were sutured, crown preparation of the upper right second and third premolars was performed, and impressions were taken. Within 24 h, crowns were cemented both to implants and teeth in the right side of the mouth. After 4 months, the animals were sacrificed and ground sections obtained for histological evaluation.Results: A higher buccal bony crestal resorption and a more apical position of the coronal level of osseointegration were found at the loaded compared with the unloaded sites. MBIC% and percentages of peri-implant mineralized tissue (MB%) were higher at the loaded compared with the unloaded sites. Moreover, a higher MBIC% was found at the lower compared with the higher final insertion torque.Conclusions: Immediate loading does not seem to have a negative effect on osseointegration. High torque values for the immediate loading procedures were not necessary. Probably, low torque values, were sufficient to obtain primary stability and hence may provide better osseointegration than high torque value.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this paper is to present the application of a three-phase harmonic propagation analysis time-domain tool, using the Norton model to approach the modeling of non-linear loads, making the harmonics currents flow more appropriate to the operation analysis and to the influence of mitigation elements analysis. This software makes it possible to obtain results closer to the real distribution network, considering voltages unbalances, currents imbalances and the application of mitigation elements for harmonic distortions. In this scenario, a real case study with network data and equipments connected to the network will be presented, as well as the modeling of non-linear loads based on real data obtained from some PCCs (Points of Common Coupling) of interests for a distribution company.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
Resumo:
The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.
Resumo:
The aim of this study was to measure changes in buccal alveolar crestal bone levels after immediate placement and loading of dental implants with Morse taper prosthetic abutments after tooth extraction. This study followed the STROBE guidelines regarding prospective cohort studies. The sample comprised 12 patients with a mean age of 45 years, in whom a central or upper lateral incisor was indicated for extraction. Prior to extraction, computed tomography (CT) analysis was carried out to assess the presence of the buccal bone crest. CT scans were performed at 24 h and at 6 months after immediate implant placement and immediate loading. The distance from the most apical point of the implant platform to the buccal bone crest was assessed at the two time points. The buccal bone crest height was evaluated at three points in the mesio-distal direction: (1) the centre point of the alveolus, (2) 1 mm mesial to the centre point, and (3) 1 mm distal to the centre point. The values obtained were subjected to statistical analysis, comparing the distances from the bone crest to the implant platform for the two time points. After 6 months there was a statistically significant, non-uniform reduction in height at the level of the crest of the buccal bone in the cervical direction. It is concluded that the buccal bone crest of the immediate implants that replaced the maxillary incisors underwent apical resorption when subjected to immediate loading.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Previous research has demonstrated that dehydration increases the threshold temperature for panting and decreases the thermal preference of lizards. Conversely, it is unknown whether thermoregulatory responses such as shuttling and gaping are similarly influenced. Shuttling, as an active behavioural response, is considered one of the most effective thermoregulatory behaviours, whereas gaping has been proposed to be involved in preventing brain over-heating in lizards. In this study we examined the effect of salt loading, a proxy for increased plasma osmolality, on shuttling and gaping in Pogona vitticeps. Then, we determined the upper and lower escape ambient temperatures (UETa and LETa), the percentage of time spent gaping, the metabolic rate ((V) over dot(O2)), the evaporative water loss (EWL) during gaping and non-gaping intervals and the evaporative effectiveness (EWL/(V) over dot(O2)) of gaping. All experiments were performed under isotonic (154 mmol l(-1)) and hypertonic saline injections (625, 1250 or 2500 mmol l(-1)). Only the highest concentration of hypertonic saline altered the UETa and LETa, but this effect appeared to be the result of diminishing the animal's propensity to move, instead of any direct reduction in thermoregulatory set-points. Nevertheless, the percentage of time spent gaping was proportionally reduced according to the saline concentration; (V) over dot(O2) was also decreased after salt loading. Thermographic images revealed lower head than body surface temperatures during gaping; however this difference was inhibited after salt loading. Our data suggest that EWL/(V) over dot(O2) is raised during gaping, possibly contributing to an increase in heat transfer away from the lizard, and playing a role in head or brain cooling.
Resumo:
ObjectiveTo compare the sequential healing at immediately loaded implants installed in a healed alveolar bony ridge or immediately after tooth extraction.Material and methodsIn the mandible of 12 dogs, the second premolars were extracted. After 3months, the mesial roots of the third premolars were endodontically treated and the distal roots extracted. Implants were placed immediately into the extraction sockets (test) and in the second premolar region (control). Crowns were applied at the second and third maxillary premolars, and healing abutments of appropriate length were applied at both implants placed in the mandible and adapted to allow occlusal contacts with the crowns in the maxilla. The time of surgery and time of sacrifices were planned in such a way to obtain biopsies representing the healing after 1 and 2weeks and 1 and 3months. Ground sections were prepared for histological analyses.ResultsAt the control sites, a resorption of the buccal bone of 1mm was found after 1week and remained stable thereafter. At the test sites, the resorption was 0.4mm at 1-week period and further loss was observed after 1month. The height of the peri-implant soft tissue was 3.8mm both at test and control sites. Higher values of mineralized bone-to-implant contact and bone density were seen at the controls compared with the test sites. The differences, however, were not statistically significant.ConclusionsDifferent patterns of sequential early healing were found at implants installed in healed alveolar bone or in alveolar sockets immediately after tooth extractions. However, three months after implant installation, no statistically significant differences were found for the hard- and soft-tissue dimensions.