949 resultados para LEAD ZIRCONATE TITANATE
Resumo:
Background: Previous research has focused on the positive consequences of flow, an intrinsically rewarding state of deep absorption. In contrast, the present research links flow to impaired risk awareness and to risky behaviour. We expected flow to enhance self-efficacy beliefs, which in turn were hypothesised to result in low risk awareness and risky behaviour in sports. In addition, we predicted that individuals' level of experience in the activity would moderate the expected effects. Methods: One study with kayakers (Study 1) and two studies with rock climbers (Studies 2 and 3) were conducted. Kayakers completed a survey while still on the river; climbers responded during and upon completion of a climb. Results: In all studies flow was related to risk awareness. Study 2 additionally showed its association with risky behaviour. Studies 2 and 3 revealed that these relationships were mediated by self-efficacy. The mediations were moderated by level of experience (Study 3). Conclusions: The results indicated that inexperienced but not experienced participants respond to self-efficacy beliefs evoked by flow with impaired risk awareness and with risky behaviour. Theoretical implications for flow and risk research as well as practical implications for risk prevention are discussed.
The optimal lead insertion depth for esophageal ECG recordings with respect to atrial signal quality
Resumo:
BACKGROUND Diagnosing supraventricular arrhythmias by conventional long-term ECG can be cumbersome because of poor p-waves. Esophageal long-term electrocardiography (eECG) has an excellent sensitivity for atrial signals and may overcome this limitation. However, the optimal lead insertion depth (OLID) is not known. METHODS We registered eECGs at different lead insertion depths in 27 patients and analyzed 199,716 atrial complexes with respect to signal amplitude and slope. Correlation and regression analyses were used to find a criterion for OLID. RESULTS Atrial signal amplitudes and slopes significantly depend on lead insertion depth. OLID correlates with body height (rSpearman=0.71) and can be estimated by OLID [cm]=0.25*body height[cm]-7cm. At this insertion depth, we recorded the largest esophageal atrial signal amplitudes (1.27±0.86mV), which were much larger compared to conventional surface lead II (0.19±0.10mV, p<0.0001). CONCLUSION The OLID depends on body height and can be calculated by a simple regression formula.
Resumo:
OBJECTIVES The aim of this study was to analyze different anatomic mapping approaches for successful ablation of outflow tract tachycardia with R/S transition in lead V(3). BACKGROUND Idiopathic ventricular tachycardia can originate from different areas in the outflow tract, including the right and left ventricular endocardium, the epicardium, the pulmonary artery, and the aortic sinus of Valsalva. Although electrocardiographic criteria may be helpful in predicting the area of origin, sometimes the focus is complex to determine, especially when QRS transition in precordial leads is in V(3). METHODS We analyzed surface electrocardiograms of 33 successfully ablated patients with outflow tract tachycardia: 20 from the right ventricular outflow tract (RVOT) and 13 from different sites. The R/S transition was determined, and the different anatomic approaches needed for successful catheter ablation were studied. RESULTS Overall, R/S transition in lead V(3) was present in 19 (58%) of all patients. In these patients, mapping was started and successfully completed in the RVOT in 11 of 19 (58%) patients. The remaining eight patients with R/S transition in lead V(3) needed five additional anatomic accesses for successful ablation: from the left ventricular outflow tract (n = 3), aortic sinus of Valsalva (n = 2), coronary sinus (n = 1), the epicardium via pericardial puncture (n = 1), and the trunk of the pulmonary artery (n = 1), respectively. CONCLUSIONS A R/S transition in lead V(3) is common. In patients with outflow tract tachycardia with R/S transition in lead V(3), a stepwise endocardial and epicardial mapping through up to six anatomic approaches can lead to successful radiofrequency catheter ablation.
Resumo:
BACKGROUND Lead exposure is associated with low birth-weight. The objective of this study is to determine whether lead exposure is associated with lower body weight in children, adolescents and adults. METHODS We analyzed data from NHANES 1999-2006 for participants aged ≥3 using multiple logistic and multivariate linear regression. Using age- and sex-standardized BMI Z-scores, overweight and obese children (ages 3-19) were classified by BMI ≥85 th and ≥95 th percentiles, respectively. The adult population (age ≥20) was classified as overweight and obese with BMI measures of 25-29.9 and ≥30, respectively. Blood lead level (BLL) was categorized by weighted quartiles. RESULTS Multivariate linear regressions revealed a lower BMI Z-score in children and adolescents when the highest lead quartile was compared to the lowest lead quartile (β (SE)=-0.33 (0.07), p<0.001), and a decreased BMI in adults (β (SE)=-2.58 (0.25), p<0.001). Multiple logistic analyses in children and adolescents found a negative association between BLL and the percentage of obese and overweight with BLL in the highest quartile compared to the lowest quartile (OR=0.42, 95% CI: 0.30-0.59; and OR=0.67, 95% CI: 0.52-0.88, respectively). Adults in the highest lead quartile were less likely to be obese (OR=0.42, 95% CI: 0.35-0.50) compared to those in the lowest lead quartile. Further analyses with blood lead as restricted cubic splines, confirmed the dose-relationship between blood lead and body weight outcomes. CONCLUSIONS BLLs are associated with lower body mass index and obesity in children, adolescents and adults.
Resumo:
Lead-gold eutectic (LGE) has been recently proposed as an alternative target material for high power spallation sources. In order to compare the corrosive properties of LGE to the better-studied eutectic of lead-bismuth (LBE), an isothermal twin-loop made of SS 316L was built and operated at the Institute of Physics of the University of Latvia. We have measured the concentration of steel alloying elements dissolved in both alloys at the end of two test campaigns via ICP-OES. In case of LGE, a pronounced concentration increase of Fe, Ni, Mn and Cr is found in the liquid metal, which is significantly higher compared to LBE. Similar results were obtained during complementary investigations on material samples exposed to both alloys in this twin-loop at 400 ◦C and 450 ◦C. These findings indicate that in contact with LGE, SS 316L steel suffers from substantial chemical attack. Detailed investigations using structure materials other than SS 316L have to be undertaken before qualifying LGE as a serious alternative to LBE.
Resumo:
Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity.
Resumo:
The shortcomings of conventional discounting, especially in the context of long-run environmental problems, have been extensively discussed in the literature. Recently, hyperbolic discounting, i. e. discounting at declining instead of constant discount rates, has attracted a lot of interest among both scientists and politicians. Although there are compelling arguments for employing hyperbolic discounting, there are also pitfalls, which have to be pointed out. In this paper I show that the problem of time-inconsistency, an inherent characteristics of hyperbolic discounting, leads to a potential clash between economic efficiency and intergenerational equity. As an example, I refer to the weak progress in the controlling of greenhouse gas emissions under the Kyoto protocol. As the problem of time-inconsistency cannot be solved on economic grounds alone, there is a need for an intergenerational moral commitment.
Resumo:
A process evaluation of the Houston Childhood Lead Poisoning Prevention Program, 1992-1995, was conducted. The Program's goal is to reduce lead poisoning prevalence. The study proposed to determine to what extent the Program was implemented as planned by measuring how well Program services were actually: (1) received by the intended target population; (2) delivered to children with elevated blood lead levels; (3) delivered in compliance with the Centers for Disease Control and Prevention and Program guidelines and timetables; and (4) able to reduce lead poisoning prevalence among those rescreened. Utilizing a program monitoring design, the Program's pre-collected computer records were reviewed. The study sample consisted of 820 children whose blood lead levels were above 15 micrograms per deciLiter, representing approximately 2.9% of the 28,406 screened over this period. Three blood lead levels from each participant were examined: the initial elevated result; the confirmatory result; and the next rescreen result, after the elevated confirmatory level. Results showed that the Program screened approximately 18% (28,406 of 161,569) of Houston's children under age 6 years for lead poisoning. Based on Chi-square tests of significance, results also showed that lead-poisoned participants were more likely to be younger than 3 years, male and Hispanic, compared to those not lead poisoned. The age, gender and ethnic differences observed were statistically significant (p =.01, p =.00, p =.00). Four of the six Program services: medical evaluations, rescreening, environmental inspections and confirmation, had satisfactory delivery completion rates of 71%-98%. Delivery timetable compliance rates for three of the six services examined: outreach contacts, home visits and environmental inspections were below 32%. However, dangerously elevated blood lead levels fell and lead poisoning prevalence dropped from 3.3% at initial screening to 1.2% among those rescreened, after intervention. From a public health perspective, reductions in lead poisoning prevalence are very meaningful. Based on these findings, the following are recommendations for future research: (1) integrate Program database files by utilizing a computer database management program; (2) target services at Hispanic male children under age 3 years living in the highest risk neighborhoods; (3) increase resources to: improve tracking and documentation of service delivery and provide more non-medical case management and environmental services; and (4) share the evaluation methodology/findings with the Centers for Disease Control and Prevention administrators; the implications may be relevant to other program managers conducting such assessments. ^