946 resultados para Irradiated Isotactic Polypropylene


Relevância:

10.00% 10.00%

Publicador:

Resumo:

One case of transdiafragmatic intercostal hernia after intense coughing fit followed by rib fractures in patient with history of pneumonia is presented. He had a severe coughing fit, developed a right toracoabdominal hematoma and then a tumor that was gradually enlarging. Image exams confirmed the diagnosis. Treatment consisted of surgical repair with the use of a polypropylene prosthetic mesh. It is a rare type of hernia. Only four cases were found in literature. The sooner the disease is diagnosed and treated the better the prognoses will be since it will prevent hernia from strangulation and incarceration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: to evaluate a one year experience with inguinal hernia repair, in patients of > 50years, with respect to the type of inguinal hernia, type of surgery, postoperative complications and recurrence. METHODS: a prospective descriptive study of patients (n=57) > 50 years operated for inguinal hernia during a one year period. Tension-free meshplasty and herniorrhaphy, using 3"x6" polypropylene mesh and 2-0 polypropylene suture, were performed in elective and emergency surgery respectively. Follow-up visits were scheduled at six weeks, three and six months postoperatively. RESULTS: the most representative age group was 61-70 years, and all patients were male. 52 (91.22%) patients had unilateral inguinal hernias, while five (8.77%) had bilateral hernias. In 50 (87.71%) patients, the hernia was uncomplicated, while seven (12.28%) patients presented with some complication such as obstruction or strangulation. Elective surgery was performed in 50 (87.71%) patients while seven (12.28%) patients were operated in emergency. Postoperatively, 50 (87.7%) patients had uneventful recovery, while seven (12.28%) patients developed some complications which were treated conservatively. Mean hospital stay was six days. One recurrence was observed and there was no peri/postoperative death. CONCLUSION: tension-free meshplasty and herniorrhaphy are safe, simple and applicable even in elderly patients after adequate pre-operative assessment and optimization. Although associated with longer hospital stay, the mortality rate is nil and complication as well as recurrence rate is low. Hence, timely repair is necessary in elderly patients even in those with comorbid conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: to compare the effects of low intensity laser therapy on in vitro bacterial growth and in vivo in infected wounds, and to analyze the effectiveness of the AsGa Laser technology in in vivo wound infections. METHODS: in vitro: Staphylococcus aureus were incubated on blood agar plates, half of them being irradiated with 904 nm wavelength laser and dose of 3J/cm2 daily for seven days. In vivo: 32 male Wistar rats were divided into control group (uninfected) and Experimental Group (Infected). Half of the animals had their wounds irradiated. RESULTS: in vitro: there was no statistically significant variation between the experimental groups as for the source plates and the derived ones (p>0.05). In vivo: there was a significant increase in the deposition of type I and III collagen in the wounds of the infected and irradiated animals when assessed on the fourth day of the experiment (p=0.034). CONCLUSION: low-intensity Laser Therapy applied with a wavelength of 904nm and dose 3J/cm2 did not alter the in vitro growth of S. aureus in experimental groups; in vivo, however, it showed significant increase in the deposition of type I and III collagen in the wound of infected and irradiated animals on the fourth day of the experiment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To analyze the performance of two surgical meshes of different compositions during the defect healing process of the abdominal wall of rats. Methods: thirty-three adult Wistar rats were anesthetized and subjected to removal of an area of 1.5 cm x 2 cm of the anterior abdominal wall, except for the skin; 17 animals had the defect corrected by edge-to-edge surgical suture of a mesh made of polypropylene + poliglecaprone (Group U - UltraproTM); 16 animals had the defect corrected with a surgical mesh made of polypropylene + polidioxanone + cellulose (Group P - ProceedTM). Each group was divided into two subgroups, according to the euthanasia moment (seven days or 28 days after the operation). Parameters analyzed were macroscopic (adherence), microscopic (quantification of mature and immature collagen) and tensiometric (maximum tension and maximum rupture strength). Results : there was an increase in collagen type I in the ProceedTM group from seven to 28 days, p = 0.047. Also, there was an increase in the rupture tension on both groups when comparing the two periods. There was a lower rupture tension and tissue deformity with ProceedTM mesh in seven days, becoming equal at day 28. Conclusion : the meshes retain similarities in the final result and more studies with larger numbers of animals must be carried for better assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crotoxin has been detoxified with gamma radiation in order to improve crotalic antiserum production. Nevertheless, present knowledge of the biological characteristics of irradiated crotoxin is insufficient to propose it as an immunizing agent. Crotoxin is known to increase the emotional state of rats and to decrease their exploratory behavior (Moreira EG, Nascimento N, Rosa GJM, Rogero JR and Vassilieff VS (1996) Brazilian Journal of Medical and Biological Research, 29: 629-632). Therefore, we decided 1) to evaluate the effects of crotoxin in the social interaction test, which has been widely used for the evaluation of anxiogenic drugs, and 2) to determine if irradiated crotoxin induces behavioral alterations similar to those of crotoxin in the social interaction, open-field and hole-board tests. Male Wistar rats (180-220 g) were used. Crotoxin (100, 250, and 500 µg/kg) was injected intraperitoneally 2 h before the social interaction test. Similarly, irradiated crotoxin (2000 Gy gamma radiation from a 60Co source) was administered at the doses of 100, 250, and 500 µg/kg for the hole-board test, and at the doses of 1000 and 2500 µg/kg for the open-field and social interaction tests. ANOVA complemented with the Dunnett test was used for statistical analysis (P<0.05). Crotoxin decreased the social interaction time (s) at the doses of 100, 250 and 500 µg/kg (means ± SEM) from 51.6 ± 4.4 to 32.6 ± 3.7, 28.0 ± 3.6 and 31.6 ± 4.4, respectively. Irradiated crotoxin did not induce behavioral alterations. These results indicate that 1) crotoxin may be an anxiogenic compound, and 2) in contrast to crotoxin, irradiated crotoxin was unable to induce behavioral alterations, which makes it a promising compound for the production of crotalic antiserum

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this Master´s Thesis was to conduct a wide scale preliminary survey regarding the package requirements of a cultured dairy package, and to compare the currently used material polystyrene to other suitable packaging materials. Polystyrene has a long history of use in dairy cups, but in recent years its price has increased significantly compared to other common packaging materials. The overall environmental effects of a package and a package material are today a part of designing a sustainable product life cycle. In addition, in certain contexts there has been discussion of the risks posed by styrene polymer for the environment and for humans. These risks are also discussed in this thesis. Polystyrene (PS) is still the most widely used material in dairy cups. In recent years, polypropylene (PP) cups have appeared in increasing numbers on market shelves. This study focuses on the differences of the suitable polymers and examines the suitability of alternative “suitable” polymers with regards to dairy packaging. Aside from focusing on the cup manufacturer, this thesis also examines its subject matter from the viewpoint of the dairy customer, as well as observing the concrete implications of material changes in the overall value chain. It was known in advance that material permeability would be one of the determining factors and that gas transmission testing would be a significant part of the thesis. Mechanical tests were the second part of the testing process, providing information regarding package strength and protectiveness during the package’s life cycle. Production efficiency, along with uninterrupted stable production, was another important factor that was taken into consideration. These two issues are sometimes neglected in similar contexts due to their self-evident nature. In addition, materials used in production may have a surprising significance to the production and efficiency. Consistent high quality is also partly based on material selection. All of the aforementioned factors have been documented and the results have been analyzed by the development team at Coveris Rigid Finland. Coveris is now calculating the total finance effects and capacities should the material changes be implemented in practice. There are many factors in favor of switching to polypropylene at the moment. The overall production costs, as well as the environmental effects of resin production are the primary influences for said switch from the converters’ perspective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genetic damage caused by ionizing radiation and repair capacity of blood lymphocytes from 3 breast cancer patients and 3 healthy donors were investigated using the comet assay. The comets were analyzed by two parameters: comet tail length and visual classification. Blood samples from the donors were irradiated in vitro with a 60Co source at a dose rate of 0.722 Gy/min, with a dose range of 0.2 to 4.0 Gy and analyzed immediately after the procedure and 3 and 24 h later. The basal level of damage and the radioinduced damage were higher in lymphocytes from breast cancer patients than in lymphocytes from healthy donors. The radioinduced damage showed that the two groups had a similar response when analyzed immediately after the irradiations. Therefore, while the healthy donors presented a considerable reduction of damage after 3 h, the patients had a higher residual damage even 24 h after exposure. The repair capacity of blood lymphocytes from the patients was slower than that of lymphocytes from healthy donors. The possible influence of age, disease stage and mutations in the BRCA1 and BRCA2 genes are discussed. Both parameters adopted proved to be sensitive and reproducible: the dose-response curves for DNA migration can be used not only for the analysis of cellular response but also for monitoring therapeutic interventions. Lymphocytes from the breast cancer patients presented an initial radiosensitivity similar to that of healthy subjects but a deficient repair mechanism made them more vulnerable to the genotoxic action of ionizing radiation. However, since lymphocytes from only 3 patients and 3 normal subjects were analyzed in the present paper, additional donors will be necessary for a more accurate evaluation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, we examined the relationship between cell phenotype and cell survival of three human non-small cell lung carcinoma cell lines (A549, NCI-H596 and NCI-H520). Cells in exponential growth at various densities were incubated for 24 h at 37ºC in a 5% CO2 humidified atmosphere and then exposed to UV radiation for 1 min (256 nm, 40 W, source-to-target distance 100 cm). After two days the surviving cells were quantified by sulforhodamine ß staining and DNA fragmentation assay. The differences in UV sensitivity at 60 x 10³ cells/cm² among the cell lines were not related to the proliferative state of the cells but to the extent of intercellular contact. In contrast to A549 and NCI-H596, irradiated NCI-H520 cells presented lower DNA fragmentation and an aggregated cell culture phenotype even prior to confluence, suggesting that a contact-effect mechanism provides further protection against UV radiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. This has been employed to attenuate animal toxins. Crotamine is a strongly basic polypeptide (pI 10.3) from Crotalus durissus terrificus venom composed of 42 amino acid residues. It induces skeletal muscle spasms leading to a spastic paralysis of hind limbs in mice. The objective of the present study was to carry out a biochemical study and a toxic activity assay on native and irradiated crotamine. Crotamine was purified from C.d. terrificus venom by Sephadex G-100 gel filtration followed by ion-exchange chromatography, and irradiated at 2 mg/ml in 0.15 M NaCl with 2.0 kGy gamma radiation emitted by a 60Co source. The native and irradiated toxins were evaluated in terms of structure and toxic activity (LD50). Irradiation did not change the protein concentration, the electrophoretic profile or the primary structure of the protein although differences were shown by spectroscopic techniques. Gamma radiation reduced crotamine toxicity by 48.3%, but did not eliminate it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prone position can be used for the planning of adjuvant radiotherapy after conservative breast surgery in order to deliver less irradiation to lung and cardiac tissue. In the present study, we compared the results of three-dimensional conformal radiotherapy planning for five patients irradiated in the supine and prone position. Tumor stage was T1N0M0 in four patients and T1N1M0 in one. All patients had been previously submitted to conservative breast surgery. Breast size was large in three patients and moderate in the other two. Irradiation in the prone position was performed using an immobilization foam pad with a hole cut into it to accommodate the breast so that it would hang down away from the chest wall. Dose-volume histograms showed that mean irradiation doses reaching the ipsilateral lung were 8.3 ± 3.6 Gy with the patient in the supine position and 1.4 ± 1.0 Gy with the patient in the prone position (P = 0.043). The values for the contralateral lung were 1.3 ± 0.7 and 0.3 ± 0.1 Gy (P = 0.043) and the values for cardiac tissue were 4.6 ± 1.6 and 3.0 ± 1.7 Gy (P = 0.079), respectively. Thus, the dose-volume histograms demonstrated that lung tissue irradiation was significantly lower with the patient in the prone position than in the supine position. Large-breasted women appeared to benefit most from irradiation in the prone position. Prone position breast irradiation appears to be a simple and effective alternative to the conventional supine position for patients with large breasts, since they are subjected to lower pulmonary doses which may cause less pulmonary side effects in the future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception) induced by small doses of carrageenin (30 µg). The electronic pressure-meter detected the antinociceptive effect of non-steroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg) or intraplantarly (30-300 µg/paw) prevented the hypersensitive effect of carrageenin (100 µg/paw). The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E2 (PGE2; 10-100 ng) in a dose-dependent manner. The hypernociceptive effect of PGE2 (100 ng) was blocked by dipyrone (160 and 320 µg/paw) but not by intraplantar administration of indomethacin (300 µg/paw). The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin) or directly block the ongoing hypernociception (dipyrone).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to establish the extent of in vitro radioresponse of lymphocytes among 62 healthy adults of both genders and to estimate the distribution of baseline micronuclei and radiosensitivity among individuals of the study population using the cytochalasin block micronucleus test. A younger study group consisted of 10 males (mean age, 22.4 years; range, 21-27) and 12 females (mean age, 24.8 years; range, 20-29), whereas an older study group consisted of 18 males (mean age, 35.1 years; range, 30-44) and 22 females (mean age, 38.5 years; range, 30-48). For evaluation of radiosensitivity blood samples were irradiated in vitro using 60Co g-ray source. The radiation dose employed was 2 Gy, the dose rate 0.45 Gy/min. The study revealed a significant gender effect on baseline micronuclei favoring females (Z = 3.25, P < 0.001), while yields of radiation-induced micronuclei did not differ significantly (Z = 0.56, P < 0.56) between genders. The distribution of baseline micronuclei among the individuals tested followed Poisson distribution in both study groups and in both genders, whereas the distribution of radiosensitivity among individuals of the older study group did not fulfill Poisson expectations (Kolmogorov-Smirnof test, P < 0.01). In contrast to a nonsignificant difference in radiosensitivity between males and females of the same age group (Z = 1.97, P < 0.56), a statistically significant difference in radiosensitivity between younger and older group for both genders was found (Z = 3.03, P < 0.03). Since the individuals tested were healthy, the observed variability in radiation response is considered to be an early effect of ageing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structure and optical properties of thin films based on C60 materials are studied. Reproducible vacuum method of thin fullerene films production with Cd impurity on Si, glass and mica surfaces is developed. Surface morphology of the films are investigated by AFM and SEM methods. The ab initio quantum - chemical calculations of the geometry, total energy and excited energy states of complex fullerene- cadmium telluride supramolecules are performed. Photoluminescence spectra of composite thin films based on C60 before and after X-ray irradiation were measured. The intensity of additional peaks is defined as the charge composition due to the type of substrate. These results are interpreted as an appearance of the dipole-allowed transitions in the fullerene excited singlet states spectrum cause of an interference with cadmium telluride. X-ray irradiated films were investigated, and additional peaks in photoluminescence spectra were detected. These peaks appear as a result of molecular complexes formation from C60CdTe mixture and dimerization of the films. Density functional B3LYP quantum-chemical calculations for C60CdTe, molecular complexes, (C60)2 and C120O dimers were performed to elucidate some experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the day-night differences in intestinal oxidative-injury and the inflammatory response following total body (TB) or abdominopelvic (AP) irradiation, and the influence of melatonin administration on tissue injury induced by radiation. Rats (male Wistar, weighing 220-280 g) in the irradiated groups were exposed to a dose of 8 Gy to the TB or AP region in the morning (resting period - 1 h after light onset) or evening (activity span - 13 h after light onset). Vehicle or melatonin was administered immediately before, immediately after and 24 h after irradiation (10, 2.0 and 10 mg/kg, ip, respectively) to the irradiated rats. AP (P < 0.05) and TB (P < 0.05) irradiation applied in the morning caused a significant increase in thiobarbituric acid reactive substance (TBARS) levels. Melatonin treatment in the morning (P < 0.05) or evening (P < 0.05) decreased TBARS levels after TB irradiation. After AP irradiation, melatonin treatment only in the morning caused a significant decrease in TBARS levels (P < 0.05). Although we have confirmed the development of inflammation after radiotherapy by histological findings, neither AP nor TB irradiation caused any marked changes in myeloperoxidase activity in the morning or evening. Our results indicate that oxidative damage is more prominent in rats receiving TB and AP irradiation in the morning and melatonin appears to have beneficial effects on oxidative damage irrespective of the time of administration. Increased neutrophil accumulation indicates that melatonin administration exerts a protective effect on AP irradiation-induced tissue oxidative injury, especially in the morning.