943 resultados para Instrumentation: spectrographs


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the development of novel typing methods based on whole genome sequencing, most laboratories still rely on classical molecular methods for outbreak investigation or surveillance. Reference methods for Clostridium difficile include ribotyping and pulsed-field gel electrophoresis, which are band-comparing methods often difficult to establish and which require reference strain collections. Here, we present the double locus sequence typing (DLST) scheme as a tool to analyse C. difficile isolates. Using a collection of clinical C. difficile isolates recovered during a 1-year period, we evaluated the performance of DLST and compared the results to multilocus sequence typing (MLST), a sequence-based method that has been used to study the structure of bacterial populations and highlight major clones. DLST had a higher discriminatory power compared to MLST (Simpson's index of diversity of 0.979 versus 0.965) and successfully identified all isolates of the study (100 % typeability). Previous studies showed that the discriminatory power of ribotyping was comparable to that of MLST; thus, DLST might be more discriminatory than ribotyping. DLST is easy to establish and provides several advantages, including absence of DNA extraction [polymerase chain reaction (PCR) is performed on colonies], no specific instrumentation, low cost and unambiguous definition of types. Moreover, the implementation of a DLST typing scheme on an Internet database, such as that previously done for Staphylococcus aureus and Pseudomonas aeruginosa ( http://www.dlst.org ), will allow users to easily obtain the DLST type by submitting directly sequencing files and will avoid problems associated with multiple databases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Off-pump coronary bypass grafting may decrease the rate of stroke, due to minimal aortic manipulation. For venous grafts, clampless hemostasis when performing the proximal anastomosis can be achieved using the Heartstring device. We describe a technique using a single device to suture two veins to one aortotomy. This technique requires less space and could be advantageous in very short, small, and calcified aortas. In to our experience, this technique is rapid, simple, easy to reproduce, and cost-saving.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Screening mammography is the only imaging modality with proved decrease in breast cancer mortality. Ultrasound has been proposed as additional tool for screening. Controversies remain about the real value of sonography in this setting. In Caucasian women with dense breast, sonography improves significantly breast cancer detection, but also increases the false positive cases, biopsies and costs. A careful selection of women who may benefit from additional screening with sonography is mandatory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of ascending aortic graft infection by an atypical bacteria, Mycoplasma hominis, with mediastinitis, a dreaded complication after cardiac surgery. A 55-year-old patient underwent ascending aorta replacement for acute type A dissection. He developed sternal instability and purulent discharge, requiring sternal wire removal and debridement. Cultures were initially sterile, but showed M. hominis infection after a significant delay and in specific culture media. The patient was treated with doxycycline and moxifloxacine. Cultures became negative and the sternum was closed on the 28th postoperative day after the first debridement. Recovery was favorable, with no signs of infection. Antibiotics were continued for one year. The patient is still asymptomatic 16 months after antibiotic interruption. Atypical organisms should be considered in the differential diagnosis of acute mediastinitis of unknown etiology after routine microbiological investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes some aspects of multichannel spectrophotometry, principles of photodiode arrays and their applications in Analytical Chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Potentiometric Stripping Analysis (PSA) is described with emphasis on ultramicroelectrode applications with a laboratory developed computer based instrumentation. The technique potentialities as compared with the voltammetric approach are pointed out based on the current literature. Some results of trace metals analysis including zinc, cadmium, lead and copper in vinegar and canned food samples are presented. The mainly advantage found in our laboratory was the technique capability to analyse natural samples with minimum matrix interference and the low level of noise found in our determinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the techniques of construction and several applications of ultramicroelectrodes in electrochemistry and electroanalytical chemistry. Disc shaped UME are produced by embedding metal wires on insulating materials such as glass or epoxy resin. In the field of electrochemistry, UME have been applied in studies of the hydrogen evolution reaction and the electrocrystallization of metals. The negligible values of sensibility for ohmic drop and the enhanced mass transport rate by spherical diffusion are the main advantages of UME in these applications. New important conclusions regarding the phenomena under study were drawn from the experimental results. The applications in electroanalytical chemistry involved the determination of contaminants such as heavy metals and nitrites in natural waters and food products. The use of UME requires little sample manipulation and, in general, no need for oxygen removal or the addition of supporting electrolytes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent technology has provided us with new information about the internal structures and properties of biomolecules. This has lead to the design of applications based on underlying biological processes. Applications proposed for biomolecules are, for example, the future computers and different types of sensors. One potential biomolecule to be incorporated in the applications is bacteriorhodopsin. Bacteriorhodopsin is a light-sensitive biomolecule, which works in a similar way as the light sensitive cells of the human eye. Bacteriorhodopsin reacts to light by undergoing a complicated series of chemical and thermal transitions. During these transitions, a proton translocation occurs inside the molecule. It is possible to measure the photovoltage caused by the proton translocations when a vast number of molecules is immobilized in a thin film. Also the changes in the light absorption of the film can be measured. This work aimed to develop the electronics needed for the voltage measurements of the bacteriorhodopsin-based optoelectronic sensors. The development of the electronics aimed to get more accurate information about the structure and functionality of these sensors. The sensors used in this work contain a thick film of bacteriorhodopsin immobilized in polyvinylalcohol. This film is placed between two transparent electrodes. The result of this work is an instrumentation amplifier which can be placed in a small space very close to the sensor. By using this amplifier, the original photovoltage can be measured in more detail. The response measured using this amplifier revealed two different components, which could not be distinguished earlier. Another result of this work is the model for the photoelectric response in dry polymer films.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A didactic description of the frequency-domain fluorometry is presented. Its fundamental aspects, the instrumentation and what one can expect from the technique are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualment, s’evidencia una dificultat en el seguiment estricte de les infeccions de transmissió sexual (ITS). A nivell mundial, aquestes causen un problema de Salut Pública (SP) en termes de morbiditat i mortalitat per complicacions i seqüeles que es poden originar si no es diagnostiquen i no es tracten adequadament. Entre les ITS més comunes trobem la provocada pel Virus del Papil·loma Humà (VPH), la principal causant del càncer de cèrvix, entre altres complicacions La família de VPH compta amb més de 150 tipus virals. El coneixement de la situació epidemiològica de la infecció per VPH es veu dificultada per varis aspectes: el caràcter asimptomàtic; l’estigma social; les dificultats diagnòstiques; la falta de homogeneïtat dels sistemes de vigilància amb la infradeclaració de casos. Ens trobem en una inversemblança constant. Les intervencions des de SP, ja sigui a nivell nacional com regional, sónpròpiament enfocades a la prevenció de la malaltia. Paral·lelament, la incidència de les ITS continua amb una tendència ascendent, cosa que provoca una inquietant preocupació. Partint de la problemàtica exposada, el present estudi pretén identificar elsconeixements que tenen els professionals d’infermeria de l’atenció primària en relació a la infecció de transmissió sexual pel virus del papil·loma humà i quina és la seva percepció i actitud sobre l’atenció a l’usuari. Es tractarà d’un estudi multicèntric amb disseny descriptiu transversal. La instrumentació es farà mitjançant una enquesta totalment anònima sobre una mostra aproximada de 115 professionals d’infermeria que durant l’any 2013 que treballen a les àrees bàsiques de salut (ABS) de l’Institut Català de la Salut (ICS) del Gironès. Aquest estudi vol fer visible la necessitat d’incrementar la formació dels professionals d’infermeria en relació a la infecció VPH i el requeriment d’un consell addicional que promogui la salut encaminat a empoderar a la comunitat mitjançant educació per a la salut

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Under the chromatographic point of view, the physico-chemical properties of a supercritical fluid are intermediate to those of the gases and liquids. Many times they approach the best features of each one, as for example, the solubilization power of liquids and low viscosity of gases. The thermodynamic definitions and main physico-chemical features of a supercritical fluid will be presented in this article. The use of supercritical fluids in analytical chemistry has been extremely modest in Brazil, even considering the enormous potential of their applications, and their use in several techniques, such as chromatography (SFC) and supercritical fluid extration (SFE). This article series is intended to discuss the historical evolution, instrumentation features and potential and limitations of the supercritical fluid use in analytical chemistry. A special focus will be centered on chromatography and extration techniques using supercritical fluids.