973 resultados para Implant-retained prostheses
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
ObjectiveThe aim of this clinical report was to reestablish the buccal bone wall after immediate implant placement. The socket defect was corrected with autogenous bone, and a connective tissue graft was removed from the maxillary tuberosity to increase the thickness, height, and width of the buccal bone and gingival tissue followed by immediate provisionalization of the crown during the same operation.Clinical ConsiderationsA 66-year-old patient presented with a hopeless maxillary left central incisor with loss of the buccal bone wall. Atraumatic, flapless extraction was performed, and an immediate implant was placed in the extraction socket followed by preparation of an immediate provisional restoration. Subsequently, immediate reconstruction of the buccal bone plate was performed, using the tuberosity as the donor site, to obtain block bone and connective tissue grafts, as well as particulate bone. Finally, immediate provisionalization of the crown followed by simple sutures was performed. Cone-beam computed tomography and periapical radiographs were taken before and after surgery. After 4 months, the final prosthetic crown was made. After a 2-year follow-up, a satisfactory aesthetic result was achieved with lower treatment time and morbidity.ConclusionThis case demonstrates the effective use of immediate reconstruction of the buccal bone wall for the treatment of a hopeless tooth in the maxillary aesthetic area. This procedure efficiently promoted harmonious gingival and bone architecture, recovered lost anatomical structures with sufficient width and thickness, and maintained the stability of the alveolar bone crest in a single procedure.Clinical SignificanceIf appropriate clinical conditions exist, immediate dentoalveolar restoration may be the most conservative means of reconstructing the buccal bone wall after immediate implant placement followed by immediate provisionalization with predictable healing and lower treatment time.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
ObjectiveTo compare peri-implant tissue healing at implants installed in sites prepared with conventional drills or a sonic device.Material and methodsIn six Beagle dogs, the mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness muco-periosteal flaps were elevated and recipient sites were prepared in both sides of the mandible. In the right side (control), the osteotomies were prepared using conventional drills, while, at the left side (test), a sonic device (Sonosurgery((R))) was used. Two implants were installed in each side of the mandible. After 8weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation.ResultsThe time consumed for the osteotomies at the test was more than double compared to the conventional control sites. No statistically significant differences were found for any of the histological variables evaluated for hard and soft tissue dimensions. Although not statistically significant, slightly higher mineralized bone-to-implant contact was found at the test (65.4%) compared to the control (58.1) sites.ConclusionsSimilar healing characteristics in osseointegration and marginal hard tissue remodeling resulted at implants installed into osteotomies prepared with conventional drills or with the sonic instrument (Sonosurgery((R))).
Resumo:
The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this paper was to evaluate the expression of RANK protein during bone-healing process around machined surface implants. Twenty male Wistar rats, 90 days old, after having had a 2 mm diameter and 6 mm long implant inserted in their right tibias, were evaluated at 7, 14, 21, and 42 days after healing. After obtaining the histological samples, slides were subjected to RANK immunostaining reaction. Results were quantitatively evaluated. Results. Immunolabeling analysis showed expressions of RANK in osteoclast and osteoblast lineage cells. The statistical analysis showed an increase in the expression of RANK in osteoblasts at 7 postoperative days and a gradual decrease during the chronology of the healing process demonstrated by mild cellular activity in the final stage (P < .05). Conclusion. RANK immunolabeling was observed especially in osteoclast and osteoblast cells in primary bone during the initial periods of bone-healing/implant interface.
Resumo:
The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Complete denture fabrication can be a treatment challenge for many dentists, especially when the patient has remaining teeth. So, planning for use of clinical alternatives to improve the treatment prognosis and to enable greater comfort to patient must be considered. This case report describes the use of remaining roots to aid in the stability, support and retention of root-supported overdentures. Thus, immediate prostheses were planned for temporary rehabilitation prior to definitive overdentures. The aim of this study was to demonstrate the planning of root-supported overdentures attached with a ball system for retention associated with immediate dentures between the periods of preparation to fabrication of the definitive overdentures. The proposed treatment met the patient's needs such as being able to carry on normal activities during the sequencing of procedures to be performed over a period of time. The treatment had longevity with patient's knowledge about the necessity of oral hygiene and periodic controls.
Resumo:
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Resumo:
This report describes a protocol for managing the accidental swallowing of dental instruments in implant dentistry, illustrated by a patient who accidentally swallowed a hexagonal wrench. The first step was to refer the patient to the medical emergency hospital service for radiographic and clinical evaluation. The hexagonal wrench was located in the stomach and was immediately removed with an endoscopic procedure. The gastric mucosa was sampled via biopsy and the sample submitted to the urease test, which was positive for Helicobacter pylori. Triple treatment was instituted for gastritis caused by H pylori to avoid exposing the patient to unnecessary risk. Removal of a foreign body by means of an endoscopic procedure constitutes a safe and effective treatment.
Resumo:
Patient perspectives on the treatment options for maxillary defects, which include free tissue transfers or obturator prostheses, may help eliminate current uncertainty as to the best choice of treatment plan. The purpose of this systematic review was to evaluate the quality of life (QoL) of patients with maxillary defects who had undergone restoration with obturator prostheses and/or free tissue transfers. A systematic search of Medline/PubMed and Web of Science databases for articles published before April 2015 was performed by 2 independent reviewers. A manual search of articles published from January 2005 to March 2015 was also conducted. Studies published in English that evaluated the QoL in patients with head and neck cancers were included. The Cohen kappa method was used to calculate inter-reviewer agreement. Ten studies were included. The University of Washington Head and Neck Questionnaire (UW-QOL) was most commonly used to measure QoL. The majority of maxillary defects were Class IIa-b. Two studies reported that the global QoL for patients with obturator prostheses is equivalent to or even better than that of other chronic disease populations. One study revealed no significant difference in QoL when the 2 treatment options were compared. The limited data indicate that the QoL of patients treated with obturator prostheses and that of patients free of tumors is similar. Well-designed clinical studies are necessary to draw definitive conclusions about how obturator prostheses compare with free tissue transfers in terms of affecting patient QoL.