999 resultados para GOLD ELECTRODE


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of three feeds incorporated with different probiotics -Lactobacil, Vizylac and Cyfolac as nutrient supplement was evaluated in an ornamental fish, Carassius auratus (Linn.). The basal diet (40% protein) was prepared and the probiotics were incorporated at different levels viz. Lactobacil at 8x10 super(7)/100g and 12x10 super(7)/100g, Vizylac at 8x10 super(7)/100g and 12x10 super(7)/100g and Cyfolac at 12x10 super(7)/100g. Feeding trial was conducted for a period of 4 weeks. At the end of the experiment, bio-growth parameters and proximate composition of the fishes were studied. The growth, survival and protein content were improved in all the probiotic fed fishes compared to control. The maximum growth (0.74 g) and survival (85%) were observed in fishes fed with Lactobacil at 12x10 super(7)/100g. It emphasizes that supplementation of feed with probiotics has a positive impact on the growth, survival and the body composition of goldfish.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant ballasts on grounds of simplicity and cost. To understand how to improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a Pspice model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioural model and Jiles-Atherton equations were used to model the current transformer core. The total loss is in close agreement with measurements from the mini-calorimeter, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation, showing that the output inductor is the primary source of loss, followed by the inverter switches. © 2011 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An attempt was made to feed bioencapsulate Lactobacillus sp. in live fish food organism Tubifex for use in the culture of gold fish Carassius auratus. The C. auratus fries when fed with bioencapsulated Lactobacillus sp. in Tubifex showed significant improvement in total wet weight gain (p<0.007) and FCR (p<0.01) compared to control. The specific growth rale and mean survival were slightly higher, although insignificantly (p>0.05) in bioencapsulated Tubifex fed group. None of the bacteriological parameters of the fish gut between the experimental and control groups differed significantly (p>0.05). Lactobacillus sp. was recorded at a level of log 5.11/g on the 90th day of experimentation. When the experimental C. auratus fries were infected with Pseudomonas fluorescents, the bioencapsulated Tubifex fed group resisted the infection. The survival was significantly higher (p<0.05) in bioencapsulated Tubifex fed group (44%) than in control (22%). The C. auratus fed with bioencapsulated Tubifex showed less (55%) signs of tail/fin rot. Likewise, a significant improvement in total wet weight gain (p<0.009), FCR (p<0.01) and SGR (p<0.04) of C. auratus brooder fed with bioencapsulated Tubifex was seen compared to control group fed with depurated Tubifex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrolysis is the most mature form of hydrogen production. Unfortunately, water electrolysis has not yet achieved the efficiency and the cost levels required for any practical application. In order to enhance the current density, modification of the electrolyte and the electrode morphology are the most popular approaches. Recently there have been numerous reports on how to improve the efficiency of hydrogen production by water splitting [1-3]. On the electrode side, the use of non-platinum high efficiency electrode materials for water splitting will provide a promising future for the hydrogen economy. An ideal electrode for water electrolysis should have good permeability to water and gas. It should also offer good electrical properties with a long life. A porous graphite plate, when coated with titania, for example, is known to provide a simple and economical electrode for water electrolysis [4]. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents experimental optimization of number and geometry of nanotube electrodes in a liquid crystal media from wavefront aberrations for realizing nanophotonic devices. The refractive-index gradient profiles from different nanotube geometries-arrays of one, three, four, and five-were studied along with wavefront aberrations using Zernike polynomials. The optimizations help the device to make application in the areas of voltage reconfigurable microlens arrays, high-resolution displays, wavefront sensors, holograms, and phase modulators. © 2012 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the modeling and characterization of interdigitated rows of carbon nanotube electrodes used to address a liquid crystal media. Finite Element Method modeling of the nanotube arrays was performed to analyze the static electric Fields produced to Find suitable electrode geometry. A device was fabricated based on the simulation results and electro optics characteristics of the device are presented. This Finding has applications in the development of micron and submicron pixels, precise beem steering and nanotube based active back planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-frequency ultrasound is needed for medical imaging with high spatial resolution. A key issue in the development of ultrasound imaging arrays to operate at high frequencies (≥30 MHz) is the need for photolithographic patterning of array electrodes. To achieve this directly on 1-3 piezocomposite, the material requires not only planar, parallel, and smooth surfaces, but also an epoxy composite filler that is resistant to chemicals, heat, and vacuum. This paper reports, first, on the surface finishing of 1-3 piezocomposite materials by lapping and polishing. Excellent surface flatness has been obtained, with an average surface roughness of materials as low as 3 nm and step heights between ceramic/polymer of ∼80 nm. Subsequently, high-frequency array elements were patterned directly on top of these surfaces using a photolithography process. A 30-MHz linear array electrode pattern with 50-μm element pitch has been patterned on the lapped and polished surface of a high-frequency 1-3 piezocomposite. Excellent electrode edge definition and electrical contact to the composite were obtained. The composite has been lapped to a final thickness of ∼55 μm. Good adhesion of electrodes on the piezocomposite has been achieved and electrical impedance measurements have demonstrated their basic functionality. The array was then packaged, and acoustic pulse-echo measurements were performed. These results demonstrate that direct patterning of electrodes by photolithography on 1-3 piezocomposite is feasible for fabrication of high-frequency ultrasound arrays. Furthermore, this method is more conducive to mass production than other reported array fabrication techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on graphene-passivated ferromagnetic electrodes (GPFE) for spin devices. GPFE are shown to act as spin-polarized oxidation-resistant electrodes. The direct coating of nickel with few layer graphene through a readily scalable chemical vapor deposition (CVD) process allows the preservation of an unoxidized nickel surface upon air exposure. Fabrication and measurement of complete reference tunneling spin valve structures demonstrate that the GPFE is maintained as a spin polarizer and also that the presence of the graphene coating leads to a specific sign reversal of the magneto-resistance. Hence, this work highlights a novel oxidation-resistant spin source which further unlocks low cost wet chemistry processes for spintronics devices.