967 resultados para Extraction methods
Resumo:
Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.
Resumo:
This special issue represents a further exploration of some issues raised at a symposium entitled “Functional magnetic resonance imaging: From methods to madness” presented during the 15th annual Theoretical and Experimental Neuropsychology (TENNET XV) meeting in Montreal, Canada in June, 2004. The special issue’s theme is methods and learning in functional magnetic resonance imaging (fMRI), and it comprises 6 articles (3 reviews and 3 empirical studies). The first (Amaro and Barker) provides a beginners guide to fMRI and the BOLD effect (perhaps an alternative title might have been “fMRI for dummies”). While fMRI is now commonplace, there are still researchers who have yet to employ it as an experimental method and need some basic questions answered before they venture into new territory. This article should serve them well. A key issue of interest at the symposium was how fMRI could be used to elucidate cerebral mechanisms responsible for new learning. The next 4 articles address this directly, with the first (Little and Thulborn) an overview of data from fMRI studies of category-learning, and the second from the same laboratory (Little, Shin, Siscol, and Thulborn) an empirical investigation of changes in brain activity occurring across different stages of learning. While a role for medial temporal lobe (MTL) structures in episodic memory encoding has been acknowledged for some time, the different experimental tasks and stimuli employed across neuroimaging studies have not surprisingly produced conflicting data in terms of the precise subregion(s) involved. The next paper (Parsons, Haut, Lemieux, Moran, and Leach) addresses this by examining effects of stimulus modality during verbal memory encoding. Typically, BOLD fMRI studies of learning are conducted over short time scales, however, the fourth paper in this series (Olson, Rao, Moore, Wang, Detre, and Aguirre) describes an empirical investigation of learning occurring over a longer than usual period, achieving this by employing a relatively novel technique called perfusion fMRI. This technique shows considerable promise for future studies. The final article in this special issue (de Zubicaray) represents a departure from the more familiar cognitive neuroscience applications of fMRI, instead describing how neuroimaging studies might be conducted to both inform and constrain information processing models of cognition.
Resumo:
Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.
Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64
Resumo:
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Resumo:
Objective: GH secretagogues (GHS) produce exaggerated ACTH and cortisol responses in Cushing`s disease (CD) patients, attributable to their direct action on GH-releasing peptide receptor type la (GHSR-1a). However, there are no studies correlating the ill vivo response to GHS and GHSR-1a mRNA expression in ACTH-dependent Cushing`s syndrome (CS) patients. The aim of this study is to correlate the patterns of ACTH and cortisol response to GH-releasing peptide-6 (GHRP-6) to GHSR-1a expression in ACTH-dependent CS patients Design: Prospective study in a tertiary referral hospital center. Fifteen CD patients and two ectopic ACTH syndrome (EAS) patients were studied. Methods: Tumor fragments were submitted to RNA extraction, and GHSR-1a expression was studied through real-time qPCR and compared with normal tissue samples. The patients were also submitted to desmopressin test and vasopressin receptor type 1B (AVPR1B) mRNA analysis by qPCR. Results: GHSR-1a expression was similar in normal pituitary samples and in corticotrophic tumor samples. GHSR-1a expression was higher in patients (CD and EAS) presenting ill vivo response to GHRP-6. Higher expression of AVPR1B was observed in the EAS patients responsive to desmopressin, as well as in corticotrophic tumors, as compared with normal pituitary samples, but no correlation between AVPR1B expression and response to desmopressin was observed in the CD patients. Conclusions: Our results revealed a higher expression of GHSR-1a in the ACTH-dependent CS patients responsive to GHRP-6, suggesting an association between receptor gene expression and ill vivo response to the secretagogue in both the CD and the EAS patients.
Resumo:
OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.
Resumo:
Minimal perfect hash functions are used for memory efficient storage and fast retrieval of items from static sets. We present an infinite family of efficient and practical algorithms for generating order preserving minimal perfect hash functions. We show that almost all members of the family construct space and time optimal order preserving minimal perfect hash functions, and we identify the one with minimum constants. Members of the family generate a hash function in two steps. First a special kind of function into an r-graph is computed probabilistically. Then this function is refined deterministically to a minimal perfect hash function. We give strong theoretical evidence that the first step uses linear random time. The second step runs in linear deterministic time. The family not only has theoretical importance, but also offers the fastest known method for generating perfect hash functions.
Resumo:
Introduction. Two-dimensional (2-D) echocardiography is an excellent alternative method to perform endomyocardial biopsies (EB) in special situations, mainly when the patient is in a critical state and cannot go to the catheterization laboratory or when there are contraindications to the use of fluoroscopy as in the pregnancy. Objective. This single-center experience analyzed the last 25 years use of an EB technique guided by echocardiography realized at the bedside on critical patients. Methods. From 1985 to 2010, we performed 76 EB guided by 2-D echocardiography on 59 patients, among whom 38 (64.4%) were critically ill with examinations at the bedside; among 10 (16.9%) subjects, the procedure was carried out simultaneously with fluoroscopy for safety`s sake during the learning period. In addition, 8 (13.6%) were unavailable for fluoroscopy, and 3 (5.1%) required a hybrid method due to an intracardiac tumor. Results. The main adverse effects included local pain (n = 4, 5.6%); difficult out successful puncture due to previous biopsies (n = 4, 5.6%); local hematoma without major consequences (n = 3, 4.2%); failed but ultimately successful puncture on the first try due to previous biopsies or (n = 3, 4.2%); obesity and immediate postoperative period with impossibility to pass the bioptome into the right ventricle; however 2 days later the procedure was repeated successfully by echocardiography (n = 1, 1.4%). All myocardial specimens displayed suitable size. There were no undesirable extraction effects on the tricuspid valve tissue. In this series, there was no case of death, hemopericardium, or other major complication as a direct consequence of the biopsy. Conclusion. 2-D echocardiography is a special feature to guide EB is mainly in critically ill patients because it can be performed at the bedside without additional risk or disadvantages of fluoroscopy. The hybrid method associating 2-D echocardiography and fluoroscopy allows the procedure in different situations such as intracardiac tumor cases.
Resumo:
Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.
Resumo:
Background: Despite all benefits offered by mandible distraction, complications and long-term consequences need to be evaluated to define its safety and morbidity. Forty mandible distractions were studied. Panoramic mandible radiographs obtained preoperatively, during distraction, and during the postoperative period were reviewed, with the intention of evaluating development and complications of molar buds and teeth in the distraction area. Methods: The mean patient age was 8.1 years. Twenty-five patients had craniofacial microsomia (one associated with a no. 10 facial cleft), five had temporomandibular joint ankylosis, two had familiar cases of auriculocondylar syndrome, one had a Tessier no. 30 facial cleft, and one had Treacher Collins syndrome. The severity of mandible hypoplasia was Pruzansky grade I in four cases, grade IIA in eight cases, grade 1113 in 16 cases, and grade III in one case. Mean radiographic follow-up was 44.8 months. Results: Molar buds located in the distraction area erupted without any deformity or displacement in 18 sides (45 percent). Fourteen cases presented distalization of a dental bud to a superior position in the mandibular ramus (four migrated back to the original position). Six molar buds presented perforations, four had shape deformities (two caused by dental fracture), and two had dental root injuries followed by root absorption lately. One case developed a dentigerous cyst. Conclusions: Almost half of the patients did not have any molar bud or tooth alterations after mandible distraction, and more than 20 percent presented only bud distalization. Therefore, preventive bud enucleation or tooth extraction should be avoided before mandible distraction.
Resumo:
Extraction of intracellular protein from Escherichia coli is traditionally achieved by mechanical disruption. A chemical treatment that destroys the integrity of the bacterial cell wall and could provide an alternative technique is examined in this study. Treatment with a combination of the chelating agent ethylenediaminetetraacetate (EDTA) (greater than 0.3 mM) and the chaotropic agent urea (6 M) is highly effective at releasing protein from uninduced E. coli. The 6 M urea in the presence of 3 mM EDTA can release cytoplasmic protein from both logarithmic-phase and stationary-phase E. coli cells at levels equivalent to mechanical disruption. The concentrations of the two chemical agents were the major variables affecting the maximum levels of protein release. Several minor variables and interactions were also identified. The kinetics of protein release is first order. For 2, 4, and 6 M urea with 3 mM EDTA, the time constant is approximately 2.5 min independent of urea concentration. Kinetics for 3 mM EDTA without urea is considerably slower, with a time constant of 12.3 min. (C) 1997 John Wiley & Sons, Inc.
Resumo:
This study investigated the effect of two anti-pronation taping techniques on vertical navicular height, an indicator of foot pronation, after its application and 20 min of exercise. The taping techniques were: the low dye (LD) and low dye with the addition of calcaneal slings and reverse sixes (LDCR). A repeated measures study was used. It found that LDCR was superior to LD and control immediately after application and exercise. LD was better than control immediately after application but not after exercise. These findings provide practical directions to clinicians regularly using anti-pronation taping techniques.
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
Here, we examine morphological changes in cortical thickness of patients with Alzheimer`s disease (AD) using image analysis algorithms for brain structure segmentation and study automatic classification of AD patients using cortical and volumetric data. Cortical thickness of AD patients (n = 14) was measured using MRI cortical surface-based analysis and compared with healthy subjects (n = 20). Data was analyzed using an automated algorithm for tissue segmentation and classification. A Support Vector Machine (SVM) was applied over the volumetric measurements of subcortical and cortical structures to separate AD patients from controls. The group analysis showed cortical thickness reduction in the superior temporal lobe, parahippocampal gyrus, and enthorhinal cortex in both hemispheres. We also found cortical thinning in the isthmus of cingulate gyrus and middle temporal gyrus at the right hemisphere, as well as a reduction of the cortical mantle in areas previously shown to be associated with AD. We also confirmed that automatic classification algorithms (SVM) could be helpful to distinguish AD patients from healthy controls. Moreover, the same areas implicated in the pathogenesis of AD were the main parameters driving the classification algorithm. While the patient sample used in this study was relatively small, we expect that using a database of regional volumes derived from MRI scans of a large number of subjects will increase the SVM power of AD patient identification.
Resumo:
INTRODUCTION The management of nonpalpable testicular masses is a challenging task, and coexisting infertility can further complicate the treatment decisions. We present our technique for microsurgical organ-sparing resection of incidental nonpalpable testicular nodules combined with microdissection for testicular sperm extraction and tissue cryopreservation in azoospermic patients. TECHNICAL CONSIDERATIONS Five infertile patients with azoospermia presented with nonpalpable hypoechoic testicular masses that were detected by Ultrasonography and underwent organ-sparing surgery. The testis was delivered through an inguinal incision, and the blood circulation was interrupted with a vascular clamp placed on the spermatic cord. Sludged ice was used to prevent warm ischemia, and a temperature probe was used to control the temperature at 12 degrees-15 degrees C. Real-time reflex ultrasonography was used to locate the tumor, and a stereotaxic hook-shaped needle was inserted under ultrasound guidance. The needle was placed adjacent to the tumor to guide the microsurgical resection. The tunica albuginea was incised over the tumor, which was dissected and removed, along with the adjoining parenchymal tissue. Frozen section studies were performed and, if malignancy was confirmed, biopsies of the tumor cavity margins and remaining parenchyma were obtained to ensure the absence of residual tumor. Microdissection was performed for excision of selected enlarged tubules that were processed and cryopreserved. CONCLUSIONS We present a technique for microsurgical organ-sparing resection of testicular tumor and sperm extraction that can be used in selected infertile patients with azoospermia in whom incidental masses have been diagnosed by ultrasonography. This conservative approach should be especially considered for patients with a solitary testis or bilateral tumors. UROLOGY 73: 887-892, 2009. (C) 2009 Elsevier Inc.