942 resultados para Energy quality
Resumo:
Background: The cerebrospinal fluid (CSF) biomarkers amyloid beta (A beta)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer`s disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer`s Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for A beta, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Molndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure A beta-(1-42), P-tau(181P), and T-tau), and 5 used Mesa Scale Discovery with the A beta triplex (A beta N-42, A beta N-40, and A beta N-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers. (C) 2011 The Alzheimer`s Association. All rights reserved.
Resumo:
Objective To evaluate the effect of the addition of methyltestosterone to estrogen and progestogen therapy on postmenopausal sexual energy and orgasm. Methods Sixty postmenopausal women in a stable relationship with a partner capable of intercourse, and presenting sexual complaints that appeared after menopause, were randomly divided into two groups: EP (n=29) received one tablet of equine estrogens (CEE) 0.625mg plus medroxyprogesterone acetate (MPA) 2.5mg and one capsule of placebo; EP+A (n=31) received one tablet of CEE 0.625mg plus MPA 2.5mg and one capsule of methyltestosterone 2.0mg; The treatment period was 12 months. The effects of treatment on sexual energy were assessed using the Sexual Energy Change Scale. The ability to reach orgasm in sexual relations with the partner was verified through monthly calendars and by calculating the ratio between monthly frequency of orgasms in sexual relations and monthly sexual frequency. Results There was a significant relationship between improvement in level of sexual energy and the addition of methyltestosterone to CEE/MPA treatment (p=0.021). No significant effect on orgasmic capacity was noted after the treatment period. Conclusion Addition of methyltestosterone to CEE/MPA therapy may increase sexual energy, but might not affect the ability to obtain orgasm in sexual relations.
Resumo:
Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Dizziness is frequent in elderly people. Aims: To evaluate the Quality of Life (QoL) in elderly subjects with dizziness, relate it with gender and age. Material and Method: A prospective study comprising 120 elderly patients with dizziness evaluated with Brazilian versions of the Whoqol-bref and the dizziness handicap inventory (DHI). The factor analysis (FA), the Mann Whitney and Kruskal Wallis tests, and the Spearman correlation were applied to study the results. Results: The most compromised domains were the DHI physical domain and the Whoqol-bref physical and environment domains. FA resulted in 3 factors in the DHI and 5 factors in the Whoqol-bref. There was a moderate correlation (-0.596) in the total scores of both instruments. Males had a better QoL in the ""environment perception and introspectivity"" and ""health perception"" factors of the Whoqol-bref test. Females had a better QoL in the ""functionality perception"" factor of the Whoqol-bref test. There were no significant age differences. Conclusions: Elderly patients with dizziness have a worse QoL. Elderly females with dizziness have worse QoL scores in ""environment perception and introspectivity"" and ""health perception"" and better QoL in the ""functionality perception"" factor compared to elderly males.
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.
Resumo:
PURPOSE: To analyze the effects of variations in femtosecond laser energy level on corneal stromal cell death. and inflammatory cell influx following flap creation in a rabbit model. METHODS: Eighteen rabbits were stratified in three different groups according to level of energy applied for flap creation (six animals per group). Three different energy levels were chosen for both the lamellar and side cut; 2.7 mu J (high energy), 1.6 mu J (intermediate energy), and 0.5 mu J (low energy) with a 60 kHz, model II, femtosecond laser (IntraLase). The opposite eye of each rabbit served as a control. At the 24-hour time point after surgery, all rabbits were euthanized and the comeoscleral rims were analyzed for the levels of cell death and inflammatory cell influx with the terminal uridine deoxynucleotidyl transferase dUTP-nick end labeling (TUNEL) assay and immunocytochemistry for monocyte marker CD11b, respectively. RESULTS: The high energy group (31.9 +/- 7.1 [standard error of mean (SEM) 2.9]) had significantly more TUNEL positive cells in the central flap compared to the intermediate (22.2 +/- 1.9 [SEM 0.8], P=.004), low (17.9 +/- 4.0 [SEM 1.6], P <= .001), and control eye (0.06 +/- 0.02 [SEM 0.009], P <= .001) groups. The intermediate and low energy groups also had significantly more TUNEL positive cells than the control groups (P <= .001). The difference between the intermediate and low energy levels was not significant (P=.56). The mean for CD11b-positive cells/400x field at the flap edge was 26.1 +/- 29.3 (SEM 11.9), 5.8 +/- 4.1 (SEM 1.6), 1.6 +/- 4.1 (SEM 1.6), and 0.005 +/- 0.01 (SEM 0.005) for high energy, intermediate energy, low energy, and control groups, respectively. Only the intermediate energy group showed statistically more inflammatory cells than control eyes (P = .015), most likely due to variability between eyes. CONCLUSIONS: Higher energy levels trigger greater cell death when the femtosecond laser is used to create corneal flaps: Greater corneal inflammatory cell infiltration is observed with higher femtosecond laser energy levels. [J Refract Surg. 2009;25:869-874.] doi:10.3928/1081597X-20090917-08
Resumo:
The goal of the current study was to compare the quality of esophageal speech and voice to videofluoroscopic features of the esophagus and pharyngoesophageal (PE) segment. The speech and voice characteristics of 30 laryngectomized patients were rated by 5 speech-language pathologists. Based on these ratings, patients were divided into 3 categories: fluent (n = 9), moderately fluent (n = 10) and nonfluent (n = 11). Videofluoroscopy of the PE region was then performed during both swallowing and voice production. An insufflation test and percutaneous pharyngeal plexus block were required in 9 patients to determine the etiology of poor esophageal voice production. The strongest videofluoroscopic indicators of nonfluent speakers were: (1) small or absent air reservoir and (2) lack of a vibrating PE segment. Fluent speakers presented with shorter PE segments (1.17 mm) compared to moderately fluent speakers (17.1-29.9 mm). Perceptually, fluent speakers presented with a predominantly rough vocal quality. In contrast, moderately fluent speakers presented with a tense quality. In addition, stoma blast noise was reduced in fluent speakers. Videofluoroscopic findings highly correlated with the quality of esophageal speech. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Objective: The purpose of this study was to evaluate the isolated and associated effects of estrogen therapy (estradiol valerate 1 mg/d orally) and physical exercise (moderate aerobic exercise, 3 h/wk) on health-related quality of life (HRQOL) and menopausal symptoms among women who had undergone hysterectomy. Design: A 6-month, randomized, double-blind, placebo-controlled clinical trial with 44 postmenopausal women who had undergone hysterectomy. The interventions were physical exercise and hormone therapy (n = 9), being sedentary and hormone therapy (n = 14), physical exercise and placebo (n = 11), and being sedentary and placebo (n = 10). HRQOL was assessed by a Brazilian standard version of the Medical Outcome Study Short-Forrn Health Survey and symptoms by Kupperman Index at baseline and after 6 months. Results: There was a decrease in symptoms in all groups, but only groups who performed physical exercise showed an increase in quality of life. Analysis of variance showed that changes in physical functioning (P = 0.001) and bodily pain (P = 0.012) scores over the 6-month period differed significantly between women who exercised and women who were sedentary, regardless of hormone therapy. Hormone therapy had no effect, and there was also no significant association between physical exercise and hormone therapy in HRQOL. Conclusions: Physical exercises can reduce menopausal symptoms and enhance HRQOL, independent of whether hormone therapy is taken.
Resumo:
Twenty-nine HCV-infected patients were treated with pegylated interferon alpha. Diagnosis was based on serum HCV RNA-PCR positive results and liver biopsy. All patients had elevated serum levels of alanine aminotransferase at the time of the study, but liver disease was compensated. Patients were evaluated at baseline treatment and after 4 and 12 weeks of antiviral treatment with the Medical Outcomes Study 36-item Short-Form Health Survey. The Mini-International Neuropsychiatric Interview was used to exclude previous or current psychiatric diagnoses. Both patients and psychiatrists were blind to the HCV RNA status, and serum HCV RNA test results only became available after the visit at week 12. After antiviral treatment, 16 patients (55.2%) were classified as nonresponders and 13 (44.8%) were classified as responders. When compared to nonresponders, responders had a greater improvement in the HRQOL scores for the mental health domain (P<.019). Differences in other domains were not significant. The present study confirms that active viral infection is one possible reason for the poor Health-Related Quality of Life in this population.
Resumo:
BACKGROUND: There is scarce literature on assessing surgical results and the impact of upper blepharoplasty on quality of life of patients. OBJECTIVE: To evaluate the impact on quality of life of patients submitted to upper blepharoplasty. METHODS: A prospective study using a standardized questionnaire applied to adult women submitted to upper blepharoplasty and evaluated 90 days later to estimate the surgical impact on quality of life and complications. RESULTS: Forty-one healthy adult females (median age of 53 years) were evaluated from June 2005 to March 2006. The questionnaire showed high internal consistency. The quality of life element with greater impact on the first postoperative week was related to physical appearance perception and that of lesser impact was associated to relationship with relatives and close friends. Hypertrophic scar was the main late complication. Satisfaction levels with the surgery were significantly related with absence of undesirable effects (p<0.01). CONCLUSIONS: The authors suggest a consistent tool to evaluate the impact of this surgical procedure on quality of life of patients. High satisfaction levels with upper blepharoplasty stood out. Keywords: Blepharoplasty; Quality of life; Patient satisfaction