797 resultados para Electrokinetic measurement
Resumo:
This paper investigates the extent to which clients were able to influence performance measurement appraisals during the downturn in commercial property markets that began in the UK during the second half of 2007. The sharp change in market sentiment produced speculation that different client categories were attempting to influence their appraisers in different ways. In particular, it was recognised that the requirement for open-ended funds to meet redemptions gave them strong incentives to ensure that their asset values were marked down to market. Using data supplied by Investment Property Databank, we demonstrate that, indeed, unlisted open ended funds experienced sharper drops in capital values than other fund types in the second half of 2007, after the market turning point. These differences are statistically significant and cannot simply be explained by differences in portfolio composition. Client influence on appraisal forms one possible explanation of the results observed: the different pressures on fund managers resulting in different appraisal outcomes.
Resumo:
A research has been conducted over methodological issues concerning the Theory of Planned Behaviour (TPB) by determining an appropriate measurement (direct and indirect) of constructs and selection of a plausible scaling techniques (unipolar and bipolar) of constructs: attitude, subjective norm, perceived behavioural control and intention that are important in explaining farm level tree planting in Pakistan. Unipolar scoring of beliefs showed higher correlation among the constructs of TPB than bipolar scaling technique. Both direct and indirect methods yielded significant results in explaining intention to perform farm forestry except the belief based measure of perceived behavioural control, which were analysed as statistically non-significant. A need to examine more carefully the scoring of perceived behavioural control (PBC) has been expressed
Resumo:
The Geostationary Earth Radiation Budget Intercomparison of Longwave and Shortwave radiation (GERBILS) was an observational field experiment over North Africa during June 2007. The campaign involved 10 flights by the FAAM BAe-146 research aircraft over southwestern parts of the Sahara Desert and coastal stretches of the Atlantic Ocean. Objectives of the GERBILS campaign included characterisation of mineral dust geographic distribution and physical and optical properties, assessment of the impact upon radiation, validation of satellite remote sensing retrievals, and validation of numerical weather prediction model forecasts of aerosol optical depths (AODs) and size distributions. We provide the motivation behind GERBILS and the experimental design and report the progress made in each of the objectives. We show that mineral dust in the region is relatively non-absorbing (mean single scattering albedo at 550 nm of 0.97) owing to the relatively small fraction of iron oxides present (1–3%), and that detailed spectral radiances are most accurately modelled using irregularly shaped particles. Satellite retrievals over bright desert surfaces are challenging owing to the lack of spectral contrast between the dust and the underlying surface. However, new techniques have been developed which are shown to be in relatively good agreement with AERONET estimates of AOD and with each other. This encouraging result enables relatively robust validation of numerical models which treat the production, transport, and deposition of mineral dust. The dust models themselves are able to represent large-scale synoptically driven dust events to a reasonable degree, but some deficiencies remain both in the Sahara and over the Sahelian region, where cold pool outflow from convective cells associated with the intertropical convergence zone can lead to significant dust production.
Resumo:
The ozone-ethene reaction has been investigated at low pressure in a flow-tube interfaced to a u.v. photoelectron spectrometer. Photoelectron spectra recorded as a function of reaction time have been used to estimate partial pressures of the reagents and products, using photoionization cross-sections for selected photoelectron bands of the reagents and products, which have been measured separately. Product yields compare favourably with results of other studies, and the production of oxygen and acetaldehyde have been measured as a function of time for the first time. A reaction scheme developed for the ozone-ethene reaction has been used to simulate the reagents and products as a function of time. The results obtained are in good agreement with the experimental measurements. For each of the observed products, the simulations allow the main reaction (or reactions) for production of that product to be established. The product yields have been used in a global model to estimate their global annual emissions in the atmosphere. Of particular interest are the calculated global annual emissions of formaldehyde (0.96 ± 0.10 Tg) and formic acid, (0.05 ± 0.01 Tg) which are estimated as 0.04% and 0.7% of the total annual emission respectively.
Resumo:
In a study using UV photoelectron spectroscopy (PES) of the atmospherically relevant reaction CH3SCH3 + Cl2 → CH3SCH2Cl + HCl bands associated with a reaction intermediate have been observed. These have been assigned to ionization of the covalently bound molecule (CH3)2SCl2 on the basis of the intensity of the observed bands as a function of reaction time, molecular orbital calculations of vertical ionization energies and evidence from infrared spectroscopy. A method has also been developed, with the flow-tube/PE spectrometer combination used, to measure photoionization cross-sections of the reagents and products at the photon energy utilized and this has allowed the photoionization cross-section of the intermediate to be estimated. This work augments an earlier study in which the rate constant of the reaction between CH3SCH3 (DMS) and Cl2 has been measured at room temperature.
Resumo:
The ability to undertake repeat measurements of flow-mediated dilatation (FMD) within a short time of a previous measurement would be useful to improve accuracy or to repeat a failed initial procedure. Although standard methods report that a minimum of 10 min is required between measurements, there is no published data to support this. Thirty healthy volunteers had five FMD measurements performed within a 2-h period, separated by various time intervals (5, 15 and 30 min). In 19 volunteers, FMD was also performed as soon as the vessel had returned to its baseline diameter. There was no significant difference between any of the FMD measurements or parameters across the visits indicating that repeat measurements may be taken after a minimum of 5 min or as soon as the vessel has returned to its baseline diameter, which in some subjects may be less than 5 min.
Resumo:
The application of automatic segmentation methods in lesion detection is desirable. However, such methods are restricted by intensity similarities between lesioned and healthy brain tissue. Using multi-spectral magnetic resonance imaging (MRI) modalities may overcome this problem but it is not always practicable. In this article, a lesion detection approach requiring a single MRI modality is presented, which is an improved method based on a recent publication. This new method assumes that a low similarity should be found in the regions of lesions when the likeness between an intensity based fuzzy segmentation and a location based tissue probabilities is measured. The usage of a normalized similarity measurement enables the current method to fine-tune the threshold for lesion detection, thus maximizing the possibility of reaching high detection accuracy. Importantly, an extra cleaning step is included in the current approach which removes enlarged ventricles from detected lesions. The performance investigation using simulated lesions demonstrated that not only the majority of lesions were well detected but also normal tissues were identified effectively. Tests on images acquired in stroke patients further confirmed the strength of the method in lesion detection. When compared with the previous version, the current approach showed a higher sensitivity in detecting small lesions and had less false positives around the ventricle and the edge of the brain