842 resultados para Electrode position
Resumo:
The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.
Resumo:
Organo-clay complex of ligand-hexadecyltrimethylammonium with montmorillonite was made for the purpose of application as a preconcentration agent in a chemically modified carbon paste electrode for determination of mercury (II) in aqueous solution. It was found out that the adsorption of Hg(II) by organo-clay complex is independent of the pH of the solution. It was also found out that the adsorption of the remaining metals Cd(II), Ps(II), Cu(II), Zn(II), and Ni(II) was dependent on the changes in pH solutions and increased when it varies from 1 to 8. The resultant material was characterized by cyclic and differential pulse anodic voltammetry using a modified graphite paste electrode in different supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, possible interferences and other variables.
Resumo:
There has been much discussion regarding the ideal position of the condyle in the mandibular fossa. Although the centric relation position (CR) is used as a reference, some authors do not believe that it is physiologic. Thus, the aim of this study was to evaluate in a group of asymptomatic individuals the position of the condyle in the mandibular fossa at maximum intercuspation (MI), with a occlusal splint and with a Lucia jig between the teeth. It was analyzed by means of magnetic resonance imaging (MRI), transcranial radiography imaging and analysis of horizontal axis of rotation from casts mounted on an articulator. The results showed that even if patients had mandibular displacement in positions of CR, habitual maximum intercuspation and with the occlusal splint, confirmed by means of the analysis of the horizontal axis of rotation, the images showed no statistically significant differences among condylar positions. It can therefore be concluded that the positions analyzed were similar and that transcranial radiography seems to be a reliable method for analyzing condylar position.
Resumo:
A study on the electrochemical behavior of histamine species in aqueous medium is described. A glassy carbon electrode chemically modified with copper (II) hexacyanoferrate (CuHCFe) film and covered with Nafion® film was employed. The interaction between the analyte and the CuHCFe film can be demonstrated by a decrease in both the cathodic and anodic peak currents at 0.68V (vs. Ag/AgCl), attributed to the film and the appearance of new peak current at 0.47V. Cyclic voltammetric parameters obtained for histamine indicate the formation of stable complex between histamine adsorbed at the electrode surface. The dependence of peak currents on the concentration of the analyte is not linear in the employed work range, indicating the presence of a coupled chemical reaction in the electrodic process. © 2010 by ESG.
Resumo:
Includes bibliography
Resumo:
Studies carried out with glass electrode in anhydrous ethanol and ethanol-water solutions for measuring pH values have shown that this parameter depends on the solution composition, the contact time with the solution, the utilized temperature, and the type of electrolyte used. It was also observed that the glass electrode behavior in an acid medium differs from an alkaline medium. These studies provided correction factors for pH values from 2 to 12, allowing the realization of proper measurements of the hydrogen ionic activity in the ethanol-water and anhydrous ethanol solutions. However, these correction factors could not be applied to the fuel ethanol. Alternatively, a new method was developed for the correction of the pH values, which can be applied in hydrous and anhydrous fuel ethanol samples. Copyright © 2011 by ASTM International.
Resumo:
The hyoid bone contributes to the maintenance of the airway, chewing and swallowing, given to its anatomical and functional relations to the craniocervical complex. Cephalometric analysis has great importance for orthopedics, orthodontics and oral maxillary surgery. For the treatment of patients with special care needs, the cephalometric evaluation of the position of the hyoid bone should also contribute as a complementary element for dental diagnosis and the selection of the adequate treatment. The aim of this paper is to demonstrate the alteration of the hyoid position after carrying out the functional orthopedic maxillary treatment in a 9 year-old patient with Down Syndrome. Initial cephalometric analysis revealed inadequate position of hyoid bone. The association of speech therapy to dynamic functional rehabilitation of jaws showed a positive effect in occlusal relation and facial expression. After treatment, all dimensions obtained from the hyoid triangle were higher than initial ones, except the anterior-posterior value of C3-H, which suggested function improvement of stomatognathic system. Once considered its anatomical and physiological relationship with the others structures of the stomatognathic system, cephalometric analysis of hyoid bone position was helpful to the comprehension of the craniofacial abnormalities related to chromosomal anomaly, and thus is essential to the interdisciplinary dialogue.
Resumo:
Objective: Assess the occurrence of secondary brow ptosis after upper lid blepharoplasty. Methods: Forty-five individuals (n90 brows) submitted to upper lid blepharoplasty, were assessed by means of a comparative analysis using pre- and post-operatively digital photographs, in the primary position of the eye. The images were processed using ImageJ software, transferred to a computer, to an electronic Microsoft Excel 2002® worksheet. Angular measurements were used, taking the lateral canthal angle of the brow, the most medial point of the brow, the medial canthal angle and the lateral canthal angle of the lid as anatomical reference points. When the outer angles were reduced or the inner angles increased after surgery this was considered a brow ptosis. Individuals who had undergone lid surgery associated with the eyebrow, previous eyebrow surgery and those with eyelid ptosis were excluded. The difference between the pre-operative and post-operative measurements were analyzed statistically using the Student's t-test for paired samples and the angular variation was compared with their corresponding contralateral sample using Wilcoxon's non-parametric test. Results: The measurements obtained after the blepharoplasty show significant variations from those before the surgery, indicating that the correction of redundant tissues in the brow accentuates the tendency of the eyebrow to move down. The alterations are more important in the lateral portion of the eyebrow and they occur bilaterally. Conclusion: The assessment of angular measurements obtained pre- and post-operatively showed that there are secondary changes in the position of the eyebrow as a result of upper eyelid blepharoplasty. © 2012 Informa Healthcare USA, Inc.
Resumo:
Copper Pentacyanonitrosylferrate (NCuNP) nanoparticles were prepared in formamide solvent. The material was characterized by Infrared (FTIR), X-Ray Diffraction (XRD) and Ultraviolet-Visible (UV-Vis) Spectroscopy. The Cyclic Voltammogram (CV) the modified graphite paste electrode with NCuNP exhibits two redox couples with (Eθ,)1 = 0.29 and (E θ,)2 = 0.86 V attribute at Cu(I)/Cu (II) and Fe(II)(CN)5NO/Fe(III)(CN) 5NO processes, respectively (KCl = 1.0 mol L-1; v = 20 mV s-1). The redox couple with (Eθ,)2 presents an electrocatalytic response for sulfite. The modified graphite paste electrode gives a linear response of 7.0 × 10-4 to 3.0 × 10-2 mol L-1 (r = 0.998), for sulfite determination with Detection Limit (DL) of 1.76 × 10-3 mol L-1 and an amperometric sensitivity of 3.38 mA/mol L-1 and relative standard desviations ± 3% (n=3). ©The Electrochemical Society.
Resumo:
Voltammetric analysis of amodiaquine using a hemin biosensor revealed a well-defined peak at 0.14 V (vs. Ag/AgCl), corresponding to the oxidation of amodiaquine at pH 7.0. The electrodic behavior indicated that the oxidation process was irreversible, and that it was controlled by diffusion. In addition to advantages such as high selectivity and sensitivity, the method developed could be used for the analysis of breast milk containing amodiaquine without any need for prior sample treatment, an important consideration in routine analysis laboratories. Measurements of the drug contained in breast milk were used to validate the technique. The detection limit for standard solutions was 3.30 mg L-1, and the quantification limit was 11.0 mg L-1. ©The Electrochemical Society.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Includes bibliography
Resumo:
A mercury film electrode was used to determine direct and simultaneously Pb(II) (at -410 mV) and Cu(II) (at -100 mV) in biodiesel by anodic stripping voltammetry. A linear response was obtained for Pb(II) and Cu(II) in the 2.00 × 10-8-1.00 × 10-7 mol L-1 concentration range and detection limits were 2.91 × 10-9 mol L-1 and 4.69 × 10-9 mol L-1 for Pb(II) and Cu(II), respectively, with recovery around of 100.0%. © 2012 Elsevier Ltd. All rights reserved.
Resumo:
This paper describes the optimisation and the analytical performances of a label-free impedimetric immunosensor for the detection of tumour marker CA125 based on gold nanoparticles modified screen-printed graphite electrode. Experimental conditions of each step for the developed immunosensor were studied and optimised. The immunosensor response varied linearly (r2 = 0.996) with antigen concentration between 0 and 100 U/mL. The estimated detection limit was 6.7 U/mL. The electrochemical immunosensor allowed unambiguous identification of CA125, while no significant non-specific signal was detected in the case of all negative controls. The analytical usefulness of the impedimetric immunosensor was finally demonstrated analysing serum samples. © 2012 Elsevier B.V. All rights reserved.
Resumo:
Erythrocharax altipinnis is described from the Serra do Cachimbo, Pará, Brazil. The new taxon is distinguished from all of the Characidae genera by having the pelvic bones firmly attached through the isquiatic processes; a nearly triangular hiatus in the musculature covering the anterior chamber of the swim bladder between the first and second pleural ribs (pseudotympanum); the pedunculate, notably expanded and distally compressed teeth in both jaws; circumorbital series represented by antorbital and four infraorbital bones with laterosensory canals not enclosed; a single tooth row in the premaxillary with the teeth perfectly aligned and similar in shape and cusp number; the first three branched dorsal-fin rays distinctly elongate in males; a bright red adipose and caudal fins in life; a conspicuous dark midlateral stripe extending from the opercle to the tip of the median caudal-fin rays; and by the absence of a humeral spot. The phylogenetic position of the new taxon is discussed using morphological and molecular datasets, with conflicting results of both approaches discussed. Additionally, a summarized discussion on the current problems in the Characidae taxonomy is presented and the principal biases in the morphological dataset are also discussed. © 2013 Netto-Ferreira et al.