965 resultados para Electric Stimulation Therapy.
Resumo:
Many experimental observations have shown that a single domain in a ferroelectric material switches by progressive movement of domain walls, driven by a combination of electric field and stress. The mechanism of the domain switch involves the following steps: initially, the domain has a uniform spontaneous polarization; new domains with the reverse polarization direction nucleate, mainly at the surface, and grow though the crystal thickness; the new domain expands sideways as a new domain continues to form; finally, the domain switch coalesces to complete the polarization reversal. According to this mechanism, the volume fraction of the domain switching is introduced in the constitutive law of the ferroelectric material and used to study the nonlinear constitutive behavior of a ferroelectric body in this paper. The principle of stationary total potential energy is put forward in which the basic unknown quantities are the displacement u(i), electric displacement D-i and volume fraction rho(I) of the domain switching for the variant I. The mechanical field equation and a new domain switching criterion are obtained from the principle of stationary total potential energy. The domain switching criterion proposed in this paper is an expansion and development of the energy criterion established by Hwang et al. [ 1]. Based on the domain switching criterion, a set of linear algebraic equations for determining the volume fraction rho(I) of domain switching is obtained, in which the coefficients of the linear algebraic equations only contain the unknown strain and electric fields. If the volume fraction rho(I) of domain switching for each domain is prescribed, the unknown displacement and electric potential can be obtained based on the conventional finite element procedure. It is assumed that a domain switches if the reduction in potential energy exceeds a critical energy barrier. According to the experimental results, the energy barrier will strengthen when the volume fraction of the domain switching increases. The external mechanical and electric loads are increased step by step. The volume fraction rho(I) of domain switching for each element obtained from the last loading step is used as input to the constitutive equations. Then the strain and electric fields are calculated based on the conventional finite element procedure. The finite element analysis is carried out on the specimens subjected to uniaxial coupling stress and electric field. Numerical results and available experimental data are compared and discussed. The present theoretic prediction agrees reasonably with the experimental results.
Resumo:
An analysis of the time-dependent resistive voltage and power deposition during the breakdown phase of pseudo-spark is presented. The voltage and current were measured by specially designed low-inductance capacitive voltage divider and current measuring resistor. The measured waveforms of voltage and current are digitized and processed by a computer program to remove the inductive component, so as to obtain resistive voltage and power deposition. The influence of pressure, cathode geometry and charging voltage of storage capacitors on the electrical properties in the breakdown phase are investigated. The results suggest that the breakdown phase of pseudo-spark consists of three stages. The first stage is mainly hollow cathode discharge. In the second stage, field-enhanced thermionic emission takes place, resulting in a fast voltage drop and sharp rise of discharge current. The third stage of discharge depends simply on the parameters of the discharge circuit.
Resumo:
In this paper we explore techniques to identify sources of electric current systems and their channels of flow in solar active regions. Measured photospheric vector magnetic fields (VMF) together with high-resolution white-light and H filtergrams provide the data base to derive the current systems in the photosphere and chromosphere. Simple mathematical constructions of fields and currents are also adopted to understand these data. As an example, the techniques are then applied to infer current systems in AR 2372 in early April 1980. The main results are: (i) In unipolar sunspots the current density may reach values of 103 CGSE, and the Lorentz force on it can accelerate the Evershed flow, (ii) Spots exhibiting significant spiral pattrn in the penumbral filaments are the sources of vertical major currents at the photospheric surface, (iii) Magnetic neutral lines where the transverse field was strongly sheared were channels along which strong current system flows, (iv) The inferred current systems produced oppositely-flowing currents in the area of the delta configuration that was the site of flaring in AR 2372.
Resumo:
Cardiovascular diseases are nowadays the first cause of mortality worldwide, causing around the 30% of global deaths each year. The risk of suffering from cardiovascular illnesses is strongly related to some factors such as hypertension, high cholesterol levels, diabetes, obesity The combination of these different risk factors is known as metabolic syndrome and it is considered a pandemic due to the high prevalence worldwide. The pathology of the disorders implies a combined cardiovascular therapy with drugs which have different targets and mechanisms of action, to regulate each factor separately. The simultaneous analysis of these drugs turns interesting but it is a complex task since the determination of multiple substances with different physicochemical properties and physiological behavior is always a challenge for the analytical chemist. The complexity of the biological matrices and the difference in the expected concentrations of some analytes require the development of extremely sensitive and selective determination methods. The aim of this work is to fill the gap existing in this field of the drug analysis, developing analytical methods capable of quantifying the different drugs prescribed in combined cardiovascular therapy simultaneously. Liquid chromatography andem mass spectrometry (LCMS/MS) has been the technique of choice throughout the main part of this work, due to the high sensitivity and selectivity requirements.
Resumo:
Functional Electrical Stimulation (FES) is a technique that consists on applying electrical current pulses to artificially activate motor nerve fibers and produce muscle contractions to achieve functional movements. The main applications of FES are within the rehabilitation field, in which this technique is used to aid recovery or to restore lost motor functions. People that benefit of FES are usually patients with neurological disorders which result in motor dysfunctions; most common patients include stroke and spinal cord injury (SCI). Neuroprosthesis are devices that have their basis in FES technique, and their aim is to bridge interrupted or damaged neural paths between the brain and upper or lower limbs. One of the aims of neuroprosthesis is to artificially generate muscle contractions that produce functional movements, and therefore, assist impaired people by making them able to perform activities of daily living (ADL). FES applies current pulses and stimulates nerve fibers by means of electrodes, which can be either implanted or surface electrodes. Both of them have advantages and disadvantages. Implanted electrodes need open surgery to place them next to the nerve root, so these electrodes carry many disadvantages that are produced by the use of invasive techniques. In return, as the electrodes are attached to the nerve, they make it easier to achieve selective functional movements. On the contrary, surface electrodes are not invasive and are easily attached or detached on the skin. Main disadvantages of surface electrodes are the difficulty of selectively stimulating nerve fibers and uncomfortable feeling perceived by users due to sensory nerves located in the skin. Electrical stimulation surface electrode technology has improved significantly through the years and recently, multi-field electrodes have been suggested. This multi-field or matrix electrode approach brings many advantages to FES; among them it is the possibility of easily applying different stimulation methods and techniques. The main goal of this thesis is therefore, to test two stimulation methods, which are asynchronous and synchronous stimulation, in the upper limb with multi-field electrodes. To this end, a purpose-built wrist torque measuring system and a graphic user interface were developed to measure wrist torque produced with each of the methods and to efficiently carry out the experiments. Then, both methods were tested on 15 healthy subjects and sensitivity results were analyzed for different cases. Results show that there are significant differences between methods regarding sensation in some cases, which can affect effectiveness or success of FES.