952 resultados para Echo cancellation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present strategies for chemical shift assignments of large proteins by magic-angle spinning solid-state NMR, using the 21-kDa disulfide-bond-forming enzyme DsbA as prototype. Previous studies have demonstrated that complete de novo assignments are possible for proteins up to approximately 17 kDa, and partial assignments have been performed for several larger proteins. Here we show that combinations of isotopic labeling strategies, high field correlation spectroscopy, and three-dimensional (3D) and four-dimensional (4D) backbone correlation experiments yield highly confident assignments for more than 90% of backbone resonances in DsbA. Samples were prepared as nanocrystalline precipitates by a dialysis procedure, resulting in heterogeneous linewidths below 0.2 ppm. Thus, high magnetic fields, selective decoupling pulse sequences, and sparse isotopic labeling all improved spectral resolution. Assignments by amino acid type were facilitated by particular combinations of pulse sequences and isotopic labeling; for example, transferred echo double resonance experiments enhanced sensitivity for Pro and Gly residues; [2-(13)C]glycerol labeling clarified Val, Ile, and Leu assignments; in-phase anti-phase correlation spectra enabled interpretation of otherwise crowded Glx/Asx side-chain regions; and 3D NCACX experiments on [2-(13)C]glycerol samples provided unique sets of aromatic (Phe, Tyr, and Trp) correlations. Together with high-sensitivity CANCOCA 4D experiments and CANCOCX 3D experiments, unambiguous backbone walks could be performed throughout the majority of the sequence. At 189 residues, DsbA represents the largest monomeric unit for which essentially complete solid-state NMR assignments have so far been achieved. These results will facilitate studies of nanocrystalline DsbA structure and dynamics and will enable analysis of its 41-kDa covalent complex with the membrane protein DsbB, for which we demonstrate a high-resolution two-dimensional (13)C-(13)C spectrum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (Δ = 2.0 mm, P = 0.0003), superior (Δ = 0.7 mm, P = 0.0001) and inferior (Δ = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Expected utility theory (EUT) has been challenged as a descriptive theoryin many contexts. The medical decision analysis context is not an exception.Several researchers have suggested that rank dependent utility theory (RDUT)may accurately describe how people evaluate alternative medical treatments.Recent research in this domain has addressed a relevant feature of RDU models-probability weighting-but to date no direct test of this theoryhas been made. This paper provides a test of the main axiomatic differencebetween EUT and RDUT when health profiles are used as outcomes of riskytreatments. Overall, EU best described the data. However, evidence on theediting and cancellation operation hypothesized in Prospect Theory andCumulative Prospect Theory was apparent in our study. we found that RDUoutperformed EU in the presentation of the risky treatment pairs in whichthe common outcome was not obvious. The influence of framing effects onthe performance of RDU and their importance as a topic for future researchis discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. METHODS: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO2 capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. RESULTS: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. CONCLUSIONS: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proton T1 relaxation times of metabolites in the human brain have not previously been published at 7 T. In this study, T1 values of CH3 and CH2 group of N-acetylaspartate and total creatine as well as nine other brain metabolites were measured in occipital white matter and gray matter at 7 T using an inversion-recovery technique combined with a newly implemented semi-adiabatic spin-echo full-intensity acquired localized spectroscopy sequence (echo time = 12 ms). The mean T1 values of metabolites in occipital white matter and gray matter ranged from 0.9 to 2.2 s. Among them, the T1 of glutathione, scyllo-inositol, taurine, phosphorylethanolamine, and N-acetylaspartylglutamate were determined for the first time in the human brain. Significant differences in T1 between white matter and gray matter were found for water (-28%), total choline (-14%), N-acetylaspartylglutamate (-29%), N-acetylaspartate (+4%), and glutamate (+8%). An increasing trend in T1 was observed when compared with previously reported values of N-acetylaspartate (CH3 ), total creatine (CH3 ), and total choline at 3 T. However, for N-acetylaspartate (CH3 ), total creatine, and total choline, no substantial differences compared to previously reported values at 9.4 T were discernible. The T1 values reported here will be useful for the quantification of metabolites and signal-to-noise optimization in human brain at 7 T. Magn Reson Med 69:931-936, 2013. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Despite major advances in care of premature infants, survivors exhibit mild cognitive deficits in around 40%. Beside severe intraventricular haemorrhages (IVH) and cystic periventricular leucomalacia (PVL), more subtle patterns such as grade I and II IVH, punctuate WM lesions and diffuse PVL might be linked to the cognitive deficits. Grey matter disease is also recognized to contribute to long-term cognitive impairment.¦OBJECTIVE: We intend to use novel MR techniques to study more precisely the different injury patterns. In particular MP2RAGE (magnetization prepared dual rapid echo gradient) produces high-resolution quantitative T1 relaxation maps. This contrast is known to reflect tissue anomalies such as white matter injury in general and dysmyelination in particular. We also used diffusion tensor imaging, a quantitative technique known to reflect white matter maturation and disease.¦DESIGN/METHODS: All preterm infants born under 30 weeks of GA were included. Serial 3T MR-imaging using a neonatal head-coil at DOL 3, 10 and at term equivalent age (TEA), using DTI and MP2RAGE sequences was performed. MP2RAGE generates a T1 map and allows calculating the relaxation time T1. Multiple measurements were performed for each exam in 12 defined white and grey matter ROIs.¦RESULTS: 16 patients were recruited: mean GA 27 2/7 w (191,2d SD±10,8), mean BW 999g (SD±265). 39 MRIs were realized (12 early: mean 4,83d±1,75, 13 late: mean 18,77d±8,05 and 14 at TEA: 88,91d±8,96). Measures of relaxation time T1 show a gradual and significant decrease over time (for ROI PLIC mean±SD in ms: 2100.53±102,75, 2116,5±41,55 and 1726,42±51,31 and for ROI central WM: 2302,25±79,02, 2315,02±115,02 and 1992,7±96,37 for early, late and TEA MR respectively). These trends are also observed in grey matter area, especially in thalamus. Measurements of ADC values show similar monotonous decrease over time.¦CONCLUSIONS: From these preliminary results, we conclude that quantitative MR imaging in very preterm infants is feasible. On the successive MP2RAGE and DTI sequences, we observe a gradual decrease over time in the described ROIs, representing the progressive maturation of the WM micro-structure and interestingly the same evolution is observed in the grey matter. We speculate that our study will provide normative values for T1map and ADC and might be a predictive factor for favourable or less favourable outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography examination of the knee in terms of joint space width and amount of contrast material between the cartilage surfaces. Direct knee MR arthrography was performed in 11 patients on a 3-T MR imaging unit using a T1-weighted isotropic gradient echo sequence in a coronal plane with and without axial traction of 15 kg. Joint space widths were measured at the level of the medial and the lateral femorotibial joint with and without traction. The amount of contrast material in the medial and lateral femorotibial joint was assessed independently by two musculoskeletal radiologists in a semiquantitative manner using three grades ('absence of surface visualization, 'partial surface visualization or 'complete surface visualization'). With traction, joint space width increased significantly at the lateral femorotibial compartment (mean = 0.55 mm, p = 0.0105) and at the medial femorotibial compartment (mean = 0.4 mm, p = 0.0124). There was a trend towards an increased amount of contrast material in the femorotibial compartment with axial traction. Direct MR arthrography of the knee with axial traction showed a slight and significant increase of the width of the femorotibial compartment with a trend towards more contrast material between the articular cartilage surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aim of the study was to determine which, and to what extent, haemodynamic parameters contribute to the remodelling of the venous limb of the Brescia-Cimino haemodialysis access. METHODS: The dimensions of the radial artery and the venous limb of the haemodialysis access were measured by an echo-tracking technique. In six ESRD patients undergoing primary arteriovenous fistula (AVF) formation, vessel diameter, wall thickness, blood pressure and blood flow were measured after the operation, and at 1 and 3 months follow-up. The contralateral forearm vessels in their native position served as baseline values for comparison. RESULTS: The diameter of the proximal antecubital vein progressively increased over the study period without reaching significant differences (4430, 5041 and 6620 microm at weeks 1, 4 and 12 respectively), whereas the intima-media thickness remained unchanged. The venous dilatation was associated with a reduction of the mean shear stress that culminated after the operation and progressively returned to normal venous values at 3 months (24.5 vs 10.4 dyne/cm(2), P<0.043). Thus the venous limb of the AVF undergoes eccentric hypertrophy as demonstrated by the increase in wall cross-sectional area (4.42 vs 6.32 mm(2) at week 1 vs week 12, P<0.028). At the time of the operation, the blood pressure in the AVF was 151+/-14/92.4+/-11 mmHg vs 49+/-19/24.5+/-6 mmHg (means+/-SEM) for the radial artery and the venous limb of the vascular access, respectively. One year after the operation the blood pressure in the venous limb had not changed: 42+/-14/25.3+/-7 mmHg (means+/-SEM). Under these conditions, the systolo-diastolic diameter changes observed in the radial artery and the antecubital vein were within a similar range at all time points: 56+/-17 vs 90+/-26 microm (means+/-SEM) at week 12. CONCLUSIONS: The increased circumferential stress resulting from the flow-mediated dilatation rather than the elevation of blood pressure appears to represent the main contributing factor to the eccentric hypertrophy of the venous limb of Brescia-Cimino haemodialysis access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the effects of the cancellation of a sizeable child benefit in Spainon birth timing and neonatal health. In May 2010, the government announced that a2,500-euro universal "baby bonus" would stop being paid to babies born startingJanuary 1, 2011. We use detailed micro data from birth certificates from 2000 to 2011,and find that more than 2,000 families were able to anticipate the date of birth of theirbabies from (early) January 2011 to (late) December 2010 (for a total of about 10,000births a week nationally). This shifting took place in part via an increase as well as ananticipation of pre-programmed c-sections, seemingly mostly in private clinics. We findthat this shifting of birthdates resulted in a significant increase in the number ofborderline low birth weight babies, as well as a peak in neonatal mortality. The resultssuggest that announcement effects are important, and that families and healthprofessionals may face effective trade-offs when deciding on the timing (and method) ofbirth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.