981 resultados para Drug control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the hypothesis that interceptive movements are controlled on the basis of expectancy of time to target arrival was tested. The study was conducted through assessment of temporal errors and kinematics of interceptive movements to a moving virtual target. Initial target velocity was kept unchanged in part of the trials, and in the others it was decreased 300 ms before the due time of target arrival at the interception position, increasing in 100 ms time to target arrival. Different probabilities of velocity decrease ranging from 25 to 100% were compared. The results revealed that while there were increasing errors between probabilities of 25 and 75% for unchanged target velocity, the opposite relationship was observed for target velocity decrease. Kinematic analysis indicated that movement timing adjustments to target velocity decrease were made online. These results support the conception that visuomotor integration in the interception of moving targets is mediated by an internal forward model whose weights can be flexibly adjusted according to expectancy of time to target arrival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prolonged standing has been associated with the onset of low back pain symptoms in working populations. So far, it is unknown how individuals with chronic low back pain (CLBP) behave during prolonged unconstrained standing (PS). The aim of the present study was to analyze the control of posture by subjects with CLBP during PS in comparison to matched healthy adults. The center of pressure (COP) position of 12 CLBP subjects and 12 matched healthy controls was recorded in prolonged standing (30 min) and quiet stance tasks (60 s) on a force plate. The number and amplitude of COP patterns, the root mean square (RMS), speed, and frequency of COP sway were analyzed. Statistical analyses showed that CLBP subjects produced less Postural changes in the antero-posterior direction with decreased postural sway during the prolonged standing task in comparison to the healthy group. Only CLBP subjects were influenced by the prolonged standing task, as demonstrated by their increased COP RMS, COP speed and COP frequency in the quiet standing trial after the prolonged standing task in comparison to the pre-PS trial. The present study provides additional evidence that individuals with CLBP might have altered sensory-motor function. Their inability to generate responses similar to those of healthy subjects during prolonged standing may contribute to CLBP persistence or an increase risk of recurrent back pain episodes. Moreover, quantification of postural changes during prolonged standing could be useful to identify CLBP subjects prone to postural control deficits. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aging is known to have a degrading influence on many structures and functions of the human sensorimotor system. The present work assessed aging-related changes in postural sway using fractal and complexity measures of the center of pressure (COP) dynamics with the hypothesis that complexity and fractality decreases in the older individuals. Older subjects (68 +/- 4 years) and young adult subjects (28 +/- 7 years) performed a quiet stance task (60 s) and a prolonged standing task (30 min) where subjects were allowed to move freely. Long-range correlations (fractality) of the data were estimated by the detrended fluctuation analysis (DFA); changes in entropy were estimated by the multi-scale entropy (MSE) measure. The DFA results showed that the fractal dimension was lower for the older subjects in comparison to the young adults but the fractal dimensions of both groups were not different from a 1/f noise, for time intervals between 10 and 600 s. The MSE analysis performed with the typically applied adjustment to the criterion distance showed a higher degree of complexity in the older subjects, which is inconsistent with the hypothesis that complexity in the human physiological system decreases with aging. The same MSE analysis performed without adjustment showed no differences between the groups. Taken all results together, the decrease in total postural sway and long-range correlations in older individuals are signs of an adaptation process reflecting the diminishing ability to generate adequate responses on a longer time scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The localization of upper airway obstruction in patients with obstructive sleep apnea (OSA) may optimize treatment. Nasoendoscopy during propofol sedation allows such an evaluation, but the effect of this drug on respiratory patterns and muscle relaxation is unknown. The objective of the present study was to determine through polysomnography whether propofol would change sleep parameters. STUDY DESIGN: Prospective study of subjects submitted to polysomnography under sedation with propofol. SETTING: Tertiary referral center. SUBJECTS AND METHODS: Fifteen non-obese subjects (4 controls/11 OSA patients) were submitted to two diurnal polysomnograms (90-120 minutes of sleep), with and without the use of propofol. The parameters presence of snoring, apnea-hypopnea index (AHI), oxygen desaturation, and sleep architecture were compared. RESULTS: The use of propofol did not induce snoring in the control subjects, whereas 100 percent of the OSA patients snored. AHI and mean oxygen saturation (SaO(2)) did not differ significantly between examinations with and without sedation. However, minimum SaO(2) differed significantly (P < 0.05) with sedation, being lower during propofol sedation. Propofol also significantly changed the sleep architecture, with a significant increase in N3 sleep (P < 0.005) and total abolishment of rapid eye movement sleep (P < 0.0005) during propofol sedation. CONCLUSIONS: These preliminary results allow us to infer that sedation with propofol changes sleep architecture but permits respiratory evaluation, because the main respiratory parameters evaluated in OSA are maintained. These preliminary results support the view that nasoendoscopy under propofol sedation is a promising examination for management of this disease. (C) 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was conducted to investigate the persistence of the effect of ""bandwidth knowledge of results (KR)"" manipulated during the learning phase of performing a manual force-control task. The experiment consisted of two phases, an acquisition phase with the goal of maintaining 60% maximum force in 30 trials, and a second phase with the objective of maintaining 40% of maximum force in 20 further trials. There were four bandwidths of KR: when performance error exceeded 5, 10, or 15% of the target, and a control group (0% bandwidth). Analysis showed that 5, 10, and 15% bandwidth led to better performance than 0% bandwidth KR at the beginning of the second phase and persisted during the extended trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cellulose pulp obtained by chemical pre-treatment of brewer`s spent grain was saccharified by a commercial cellulase preparation and the produced hydrolysate (50 g/l glucose) was fermented to lactic acid by Lactobacillus delbrueckii. The effects of pH control and nutrient supplementation of the hydrolysate on fermentation performance were investigated. Addition of 5g/l yeast extract enhanced the lactic acid volumetric productivity that attained 0.53 g/l h, value 18% higher than that obtained from non-supplemented hydrolysate. Addition of the MRS broth medium components (except the carbon source) was still better, providing a productivity of 0.79 g/l h. In all the cases, the lactic acid yield factor was of 0.7 g/g glucose consumed, but the fermentations stopped after 24 h due to the pH drop from 6.0 to 4.2, resulting in large amounts of residual glucose (38-41 g/l). Fermentation runs pH-controlled at 6.0 gave better results than those where the initial pH was not further controlled. The best result, 35.54 g/l lactic acid (0.99 g/g glucose consumed) was obtained during the pH-controlled fermentation of hydrolysate medium supplemented with MRS components. The volumetric productivity at the end of this fermentation was 0.59 g/l h, with a maximum of 0.82 g/l h during the first 12 h. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multicenter descriptive study was carried out in two steps: an interview with providers involved in the medication processes, and then non-participating observation of their environment and practices. Only one hospital was found to have a bar-coding, dispensing system connected to a computerized prescription system. fit all participating hospitals at least 90% of the drugs were dispensed and distributed as unit doses, but in none of them did pharmacists assess prescriptions. The study findings showed that the processes of drug dispensing and distribution in Brazilian hospitals encounter several problems, mostly associated to work environment conditions and inadequacy in drug ordering and requests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Adverse drug events (ADEs) are harmful and occur with alarming frequency in critically ill patients. Complex pharmacotherapy with multiple medications increases the probability of a drug interaction (DI) and ADEs in patients in intensive care units (ICUs). The objective of the study is to determine the frequency of ADEs among patients in the ICU of a university hospital and the drugs implicated. Also, factors associated with ADEs are investigated. Methods This cross-sectional study investigated 299 medical records of patients hospitalized for 5 or more days in an ICU. ADEs were identified through intensive monitoring adopted in hospital pharmacovigilance and also ADE triggers. Adverse drug reactions (ADR) causality was classified using the Naranjo algorithm. Data were analyzed through descriptive analysis, and through univariate and multiple logistic regression. Results The most frequent ADEs were ADRs type A, of possible causality and moderate severity. The most frequent ADR was drug-induced acute kidney injury. Patients with ADEs related to DIs corresponded to 7% of the sample. The multiple logistic regression showed that length of hospitalization (OR = 1.06) and administration of cardiovascular drugs (OR = 2.2) were associated with the occurrence of ADEs. Conclusion Adverse drug reactions of clinical significance were the most frequent ADEs in the ICU studied, which reduces patient safety. The number of ADEs related to drug interactions was small, suggesting that clinical manifestations of drug interactions that harm patients are not frequent in ICUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate drug interaction software programs and determine their accuracy in identifying drug-drug interactions that may occur in intensive care units. Setting The study was developed in Brazil. Method Drug interaction software programs were identified through a bibliographic search in PUBMED and in LILACS (database related to the health sciences published in Latin American and Caribbean countries). The programs` sensitivity, specificity, and positive and negative predictive values were determined to assess their accuracy in detecting drug-drug interactions. The accuracy of the software programs identified was determined using 100 clinically important interactions and 100 clinically unimportant ones. Stockley`s Drug Interactions 8th edition was employed as the gold standard in the identification of drug-drug interaction. Main outcome Sensitivity, specificity, positive and negative predictive values. Results The programs studied were: Drug Interaction Checker (DIC), Drug-Reax (DR), and Lexi-Interact (LI). DR displayed the highest sensitivity (0.88) and DIC showed the lowest (0.69). A close similarity was observed among the programs regarding specificity (0.88-0.92) and positive predictive values (0.88-0.89). The DIC had the lowest negative predictive value (0.75) and DR the highest (0.91). Conclusion The DR and LI programs displayed appropriate sensitivity and specificity for identifying drug-drug interactions of interest in intensive care units. Drug interaction software programs help pharmacists and health care teams in the prevention and recognition of drug-drug interactions and optimize safety and quality of care delivered in intensive care units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SETTING: Thirty-six priority cities in Sao Paulo State, Brazil, with a high incidence of tuberculosis (TB) cases, deaths and treatment default. OBJECTIVE: To identify the perspectives of city TB control coordinators regarding the most important components of adherence strategies adopted by health care teams to ensure patient adherence in 36 priority cities in the State of Sao Paulo, Brazil. DESIGN: Qualitative research with semi-structured interviews conducted with the coordinators of the National TB Control Programme involved in the management of TB treatment services in the public sector. RESULTS: The main issues thought to influence adherence to directly observed treatment (DOT) by coordinators include incentives and benefits delivered to patients, patient-health care worker bonding and comprehensive care, the encouragement given by others to follow treatment (family, neighbours and health professionals), and help provided by health professionals for patients to recover their self-esteem. CONCLUSION: The main aspects mentioned by city TB control coordinators regarding patient adherence to treatment and to DOT in Sao Paulo are improvements in communications, relationships based on trust, a humane approach and including the patients in the decision-making process concerning their health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medication administration errors (MAE) are the most frequent kind of medication errors. Errors with antimicrobial drugs (AD) are relevant because they may interfere inpatient safety and in the development of microbial resistance. The aim of this study is to analyze the AD errors detected in a Brazilian multicentric study of MAE. It was a devcriptive and explorotory study carried out in clinical units in five Brazilian teaching hospitals. The hospitals were investigated during 30 days. MAE were detected by observation technique. MAE were classified in categories: wrong route(WR), wrong patient(WP), wrong dose(WD) wrong time (WT) and unordered drug (UD). AD with MA E were classified by Anatomical-Therapeutical-Chemical Classification System. AD with narrow therapeutic index (NTI) wet-e identified A descriptive statistical analysis was performed using SPSS version 11.5 software. A total of 1500 errors were observed, 277 (18.5%) of them were error with AD. The hopes of AD error were: WT87.7%, QD 6.9%, WR 1.5%, UD 3.2% and WP 0.7%. The number of AD found was 36. The mostly ATC class were fluoroquinolones 13.9%, combinations of penicillin 13.9%, macrolides 8.3% and third-generation cephalosporines 5.6%. The parenteral drug dosage form was associated with 55.6% of AD. 16.7% of AD were NTI. 47.4% of WD and 21.8% WT were with NTI drugs. This study shows that these errors should be considered potential areas for improvement in the medication process and patient safety plus there is requirement to develop rational drug use of AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a compact embedded fuzzy system for three-phase induction-motor scalar speed control. The control strategy consists in keeping constant the voltage-frequency ratio of the induction-motor supply source. A fuzzy-control system is built on a digital signal processor, which uses speed error and speed-error variation to change both the fundamental voltage amplitude and frequency of a sinusoidal pulsewidth modulation inverter. An alternative optimized method for embedded fuzzy-system design is also proposed. The controller performance, in relation to reference and load-torque variations, is evaluated by experimental results. A comparative analysis with conventional proportional-integral controller is also achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We proposed a connection admission control (CAC) to monitor the traffic in a multi-rate WDM optical network. The CAC searches for the shortest path connecting source and destination nodes, assigns wavelengths with enough bandwidth to serve the requests, supervises the traffic in the most required nodes, and if needed activates a reserved wavelength to release bandwidth according to traffic demand. We used a scale-free network topology, which includes highly connected nodes ( hubs), to enhance the monitoring procedure. Numerical results obtained from computational simulations show improved network performance evaluated in terms of blocking probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two different fuzzy approaches to voltage control in electric power distribution systems are introduced in this paper. The real-time controller in each case would act on power transformers equipped with under-load tap changers. Learning systems are employed to turn the voltage-control relays into adaptive devices. The scope of this study has been limited to the power distribution substation, and the voltage measurements and control actions are carried out on the secondary bus. The capacity of fuzzy systems to handle approximate data, together with their unique ability to interpret qualitative information, make it possible to design voltage-control strategies that satisfy the requirements of the Brazilian regulatory bodies and the real concerns of the electric power distribution companies. Fuzzy control systems based on these two strategies have been implemented and the test results were highly satisfactory.