932 resultados para Doses de Radiação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potassium (K) is the second nutrient that is required in larger amounts by soybean crop. With the use of high doses of that nutrient and increase of no-tillage areas in last years, some changes occurred in ways of this nutrient application, as well as the introduction of cover crops in the system for straw formation. Due those facts, the aim with this work was to study doses and times of potassium application for soybean sowed as succession for cover crops in no-tillage system, in a clayey Distrofic Red Latosol, in cerrado region. The experimental design was a randomized block with treatments arranged in 3x3x5 factorial scheme, with the following factors, cover crops: Pearl millet (Pennisetum glaucum) and Proso millet (Panicum miliaceum) and a control (fallow area), rates of K2O (0, 50 e 100 kg ha(-1)) and K2O application forms (100% in the cover crops; 100% at sowing of soybean; 100% in topdressing in soybean; 50% at sowing cover crops + 50% at soybean sowing; 50% at soybean sowing + 50% in topdressing in the soybean) with four replicates. The Pennisetum glaucum as soybean predecessor crop yields higher dry matter content than the Panicum miliaceum in a short period of time. In clay soil with high content of potassium there was no response to the applied potassium levels. Full doses of potassium maintenance fertilization can be applied in the predecessor cover crop, at sowing or topdressing in soybean crop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The crop demand by nitrogen varies from one crop to other as well as the amount and application time, and this nutrient can be lost by leaching, volatilization and erosion. The objective of this study was to evaluate doses, sources and times of nitrogen application in rice of high lands cropped in no till system. The work was conducted in Selviria, State of Mato Grosso do Sul, Brazil, in a soil originally under Cerrado vegetation. A randomized blocks design, with the treatments disposed in a factorial scheme 5x3x2 was used. The treatments were constituted by five nitrogen doses (0, 50, 100, 150 and 200 kg ha(-1)), three nitrogen sources (urea; ammonium sulfonitrate plus nitrification inhitor and ammonium sulfate) and two application times (at sowing or at flower bud differentiation), with four repetitions. The sources of nitrogen, as well as the application times had similar effects for most of evaluations. The N doses influenced linearly or with quadratic adjustment the plant height, N leaf content and grains yield, in the two growing seasons. The chlorophyll content and the number of ears m(-2) were affected only, in the first year. The highest yield in the growing season of 2007/08 was obtained with the dose of 149 kg ha(-1) of N. In 2008/09 growing season the increase of N doses provided increment in the grains rice yield, until the maximum dose evaluated (200 kg ha(-1) of N).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of cover crops can produce large amounts of biomass, improving the cycling of nutrients, particularly nitrogen, promoting productivity gains and cost savings. Given this, the objective was to evaluate the use of N rates associated to cover crops grown in pre-harvest nutritional status, nitrogen accumulation and corn yield in both years. The experiment was conducted in an Oxisol with maize, no-tillage system. The experimental design was a randomized block, split plot with four replications. The main treatments were: six cropping systems (sun hemp, jack bean, lablab, millet, and velvet bean fallow) in secondary treatments: four doses of nitrogen (0, 60, 120 and 180 kg ha(-1) N). Corn yield was not affected by the type of coverage for pre-season, regardless of the nitrogen applied in the soil. Still, the use of nitrogen fertilizer in the soil promotes gains in grain yield in the first year of cultivation, regardless of the type of coverage in pre-season. In the first year (2006/2007) the species of coverage produced more biomass were velvet bean, jack bean, sun hemp and lablab, while in the second year (2007/08) were the sun hemp, millet, lablab, jack bean and velvet bean, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this work are to analyze the direct solar radiation pressure torque (TPRS) in the rotational motion of spin-stabilized artificial satellites, to numerically implement these solutions and to compare the results with real data of the Brazilian Satellite Data Collection – SCD1 and SCD2, supplied by INPE. The mathematical model for this torque is determined for a cylindrical satellite, and the components of this torque are determined in a fixed system in the satellite. An analytical solution for the spin motion equations is proposed, in which TPRSD does not affect the spin velocity of the satellite. Two approaches are adopted in the numerical implementation of the developed theory: the first one considers the proposed theory and the second introduces a variation in the spin velocity based on its real variation. The results obtained indicate that the solar radiation pressure torque has little influence in the right ascension and declination axis of rotation due to the small dimension of the satellite and altitude in which it is found. To better validate the application of the presented theory, the angular deviation of the spin axis and solar aspect angle were also analyzed. The comparison of the results of the approaches conducted with real data show good precision in the theory, which can be applied in the prediction of the rotational motion of the spin-stabilized artificial satellites, when others external torques are considered besides the direct solar radiation pressure torque

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diuron (3-(3,4-Dichlorophenyl)-1,1-dimethylurea) is a substituted urea herbicide widely used on agricultural crops such as soy, cotton and sugar cane. In a previous long-term study this herbicide exerted carcinogenic activity on the urinary bladder and renal pelvis mucosa of Wistar rats and breast of mice. Also, it was shown to be carcinogenic to the mice skin in a initiation-promotion assay. In 1997, the northamerican EPA evaluated Diuron as a “known/likely” carcinogen for humans (USEPA, 2004). In a previous study developed at this laboratory, male Wistar rats treated with Diuron 2500 ppm during 20 weeks presented increased indices of cell proliferation and incidences of simple urothelial hyperplasia (HS) in the urinary bladder. Under scanning electron microscopy (SEM) severe urothelial necrosis and hyperplasia were observed. However, in that study the urinary bladders of animals exposed to lower doses of Diuron were not examined under SEM. Therefore, the possible dose-response influence of Diuron on the urothelium under SEM is not known. The present study aimed to analyze under SEM the urinary bladder of male Wistar rats exposed to 125 ppm, 500 ppm and 2500 ppm doses of Diuron through diet during 20 weeks and to compare to the previous histological findings in the same material. Under SEM, 125 ppm and 2500 ppm groups presented significantly (p<0,05) increased incidences of simple hyperplasia, i.e., 7/10 and 8/10 respectively, compared to control group and the 500 ppm group The sensitivity of SEM was higher since it detected a 45% incidence of hyperplasiaswhile the histological analysis found only 27%. Considering SEM as the gold-standard, histology showed a 44% sensitivity, 86.4% specificity, a positive predictive value of 72,7% and negative predictive value of 65,5% and accuracy of 67,5%. Scanning Electron Microscopy...(Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wide territorial extension of Brazil derails the installation and maintenance of instruments for measuring solar radiation, which makes necessary the development and application of models that are able to estimate reliable and sufficient data for many different activities that use such data. And these, in most cases, are estimated from the Ångström equation. Based on this model, this project aimed to estimate the global solar radiation at Presidente Prudente-SP, Brazil, using daily data from 1999 to 2007. The solar radiation data have been extracted from the paper tapes of actinograph bi-metallic (Robitsch) daily records at the meteorological station in the Faculty of Science and Technology, UNESP. These tapes were scanned, resulting in digital images with x and y coordinates pairs (x = time; y = solar radiation, cal/min.cm²). The daily global solar radiation is the area under the curve of the image. This value has been calculated by computer algorithms. After the acquisition and calculation of the values needed to develop the Ångström equation have been determined the constants a and b, using linear regression between the values of Rg/R0 (solar radiation/solar radiation on a horizontal surface at the top of atmosphere), as ordered, and n/N (number of hours of sunshine/day length in hours) as abscissa. The slope of the line will be the constant b and the linear coefficient, the constant a. The estimated results were compared to the observed using the Kolmogorov-Smirnov test, realizing that the models can be accepted. So, the equation to aim the solar global radiation is: Rg = R0 (0,2662+0,3592 n/N)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A proposta desse trabalho surgiu da possibilidade de unir metodologias eficientes para estabelecer valores mais precisos de densitometria óssea. A densidade óssea é um parâmetro biofísico de grande importância experimental e clínica, que permite avaliar o processo de mineralização óssea. O objetivo deste trabalho foi determinar a densidade óssea e o coeficiente de atenuação de massa da radiação gama com o radioisótopo 241Am com fotopico de 59,6 keV em rádios de cães SRD (Sem Raça Definida). Conclui-se a que a densidade média das amostras foi de 1,91 g/cm³ com um desvio padrão de 0,0599. Para o coeficiente de atenuação de massa, o valor médio foi de 0,241 cm2/g, com desvio padrão de 0,0151. Para ambos os parâmetros o coeficiente de variação foi pequeno implicando em uma baixa dispersão. Isso também demonstra que os métodos aplicados foram eficientes e de fácil aplicabilidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente, as pesquisas acadêmicas e industriais não estão voltadas apenas para a descoberta de novos fármacos, mas também para novas maneiras de administração de medicamentos pretendendo obter melhores ações farmacológicas alem de reduzir efeitos colaterais. Partindo deste pressuposto, estudos demonstram que inúmeras moléculas podem ser incorporadas a polímeros híbridos orgânico-inorgânico preparados pelo processo sol-gel, assim pretende-se estudar a possibilidade de sua aplicação no desenvolvimento de um dispositivo de liberação controlada de fármacos na forma de implantes subcutâneos. As matrizes hibridas para serem implantadas devem, necessariamente, ser estéreis. Para isto este trabalho analisa a interação entre o processo de esterilização e uma provável alteração estrutural nestes polímeros. A esterilização por calor úmido em autoclave e a esterilização por radiação gama foram escolhidas para analisar a correlação entre alteração estrutural do hibrido e o processo de eliminação de microorganismos. Outro aspecto que levamos em consideração foi a melhora das características mecânicas das matrizes poliméricas confeccionadas com poli óxido etileno de peso molecular 1900 (POE 1900) e poli óxido propileno de peso molecular 400 (POP 400). Para serem implantadas estas matrizes devem estar uniformes, e não podem trincar ou quebrar antes ou após a implantação. Considerando estes fatores foi adicionado as amostras um agente plastificante, o álcool polivinílico (PVA), na tentativa de melhorar estas características

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is a branch of medical physics related to the treatment of malignant neoplasm, being an important instrument in the fight against cancer, when combined with the effort of a multidisciplinary team, composed of, physicians, physicists, nurses and technicians. Every year more than 3.5 million new cases of cancer are recorded in the world, being the prostate cancer responsible for approximately 25% of this amount (INCA and IARC, 2008). In this type of cancer, radiotherapy is a method indicated for treatement. The technological advance in this area over years has allowed a greater accuracy in the tumor location, more conformation of the radiation beam around the tumor, reducing the dose in healthy tissues and a consequent dose increase on treatment (Bedford et al., 1999). A radiotherapy planning, in which the physicist develops an important role, is composed of several steps, including choosing the best configuration of treatment beams. This choice has a close relationship with success of therapy and is critical to achieve the best distribution of dose inside the tumor and expose the least as possible the healthy tissue to radiation. In this work, two options for setting up camps in the first phase in a treatment of prostate cancer were simulated in computer planning: 4 fields orthogonal or “Box” with gantry angles in 00, 1800, 2700 e 90° and 4 fields angled or “X” (1350, 450, 3150 e 2250). The percentage of the rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5% respectively (Greco et al., 2003). The femoral toxicity have limited dose by 70% of the total dose prescribed in a prostate treatment (Bedford et al., 1999). The planning of 27 patients with prostate adenocarcinoma submitted to 3D conformal radiotherapy were accompanied. As a result, it was assessed that the best TCP (tumor control probability)... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of pesticides in Brazil has intensified over the years. And since 2009 it was ranked as the largest market for pesticides worldwide. The consequential diffuse contamination of the environment is therefore due to the increasing number of chemicals of different classes, origins and modes of action. Little is known about the action of pesticides on human health in situations of co-exposure. Possible toxic effects are not restricted to agricultural and industrial workers, but also the general population that may be exposed continuously to its residues in food and water. Although these pesticides are mostly present in the environment at low doses, it must be considered that possible cumulative or synergistic effects may occur when there are concurrent or sustained exposure for two or more of these agents, which can lead to late manifestation of subclinical damages, sometimes irreversible. Thus, the specific objective of this study was to assess the effect of carcinogenesis promotion of a mixture of pesticides at low doses and analyze the phenomena of cell proliferation and apoptosis in rat liver. A total of 50 male Lewis rats was separated into 5 groups for 8 weeks in a medium term hepatocarcinogenesis model. The three different classes of pesticides (dieldrin, dicofol, endosulfan, dichlorvos and permethrin), whose residues were detected by ANVISA during the period from 2001 to 2005 in tomatoes cultures, were added to the feed of rats initiated to hepatocarcinogenesis with diethylnitrosamine (DEN- 200mg/kg ip). We used two different mixtures, one with no toxic effects at doses (MEX1) referring to the NOEL (no-observed-effect level) and another at doses LOEL / LEL / LOAEL (Lowest-observed-effect level / Lowest-effect level / Lowest -observed-adverse-effect level), to the installation of adverse effects (MEX2), derived from chronic studies. All animals ...(Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)